Invicta EBK Flameproof Base-Mounted Vibrators

Our EBK series provides electric rotary vibration with adjustable out-of-balance weights 0–100% at both ends. We list IM1081 base mounting, totally enclosed IC410 construction, an integral cast top-mounted terminal box and a Hammertone Silver finish. The range supports DOL starting and S1 continuous duty, with VVVF operation subject to the selected unit's speed and temperature-protection conditions.

Select the gas group and temperature class

The website and Issue G brochure describe Ex db, gas zones 1 and 2, −20°C to +40°C, and voltages up to 690 V. Frame sizes EBK20–40 are described for gas groups IIA and IIB; EBK45–75 for IIA only. These are source claims whose current certificate and selected-model applicability must be confirmed with us.

The brochure describes fixed-speed EBK as T3. For variable-speed applications it requires 160°C thermistors connected into the control circuit; T4 applications require 120°C thermistors specified and connected. The website compresses these conditions into different wording. Confirm the temperature class, sensors and control arrangement for your duty; a thermistor setting is not the motor's ambient rating.

The separate EBKH offering is described for −20°C to +55°C. This does not raise standard EBK's 40°C limit. No separate EBKH model schedule is attached, so we do not create EBKH variants from the EBK table.

Construction and protection scope

The website lists IP66, Class F insulation and Class B temperature rise at 40°C ambient. Brochure page 47 distinguishes IP66 main enclosure from IP65 terminal box. We retain that distinction rather than claiming IP66 for every part of the assembly.

The brochure certification summary cites CML16ATEX1113X–1121X, II 2 G c / Ex db IIA and IIB (some models IIA only), and T3 (200°C) or T4 (135°C) with an unexplained double-asterisk. It also lists PESO references P363731/1-8 and P357033/1. These references do not replace the selected unit's current certificate and special conditions.

Ratings and mounting

The four speed schedules below contain 42 EBK entries. Each retains mechanical force, working moment, 50/60 Hz weight, input/output power, operating/starting current and corresponding dimension row. The printed temperature-class choices require selection, not an assumption that a supplied unit carries both ratings. Provide your environment, motor duty, power supply, required force, mounting position and temperature class so we can confirm the configuration.

2-pole — 2,880/3,456 rpm — 50/60 Hz

Issue G pages 16–17. ● = 50 Hz only; ◇ = 60 Hz only. Specify the required temperature class at order. Current columns retain their voltage/frequency conditions; working moment is printed Kg.cm. ×2. Dimensional letters refer to the original figure; N is a cable-entry thread and thermistor entry is shown separately. Model prefixes on continuation rows follow the source spread.

Ratings and model designations — PDF page 16

Frame/model designation (frequency-only symbol retained) Temperature Class (source label) Centrifugal Force Kg (source label) Centrifugal Force Newtons Working Moment Kg.cm. (x2) / 50Hz Working Moment Kg.cm. (x2) / 60Hz Weight Kg / 50Hz Weight Kg / 60Hz Watts Input Watts Output Full Load Current / 400V / 50Hz (current unit not printed)
EBK 20 -5/2 T3 or T4 500 4905 10.8 7.5 22 22 450 340 0.78
EBK 25 -8/2 T3 or T4 800 7848 17.2 12.0 39 38 665 500 1.17
EBK 25 -10/2 T3 or T4 1000 9810 21.6 15.0 40 39 665 500 1.17
EBK 25 -13/2 T3 or T4 1300 12753 28.0 19.5 41 40 665 500 1.17
EBK 30 -16/2 T3 or T4 1600 15696 34.5 24.0 61 60 1410 1100 2.1
EBK 30 -20/2 T3 or T4 2000 19620 43.2 30.0 63 62 1410 1100 2.1
EBK 40 -30/2 T3 or T4 3000 29430 64.7 44.9 100 99 1875 1500 2.9

Electrical continuation and dimensions — PDF page 17

Model — facing-page source row Full Load Current / 460V / 60Hz (current unit not printed) Starting Current / 400V / 50Hz (current unit not printed) Starting Current / 460V / 60Hz (current unit not printed) Fig. Dimension A / mm as table heading Dimension B / mm as table heading Dimension C / mm as table heading Dimension D / mm as table heading Dimension E / mm as table heading Dimension F / mm as table heading Dimension G / mm as table heading Dimension H / mm as table heading Dimension J / mm as table heading Dimension K / mm as table heading Dimension L / mm as table heading Dimension M / mm as table heading Cable entry N / thread designation as printed
EBK 20 -5/2 0.69 5.6 4.9 A 330 150 171 110 140 185 87 16 4 x 14 186 179 74 M20x1.5p-6H
EBK 25 -8/2 1.05 10.2 8.9 A 363 190 225 150 185 258 120 40 4 x 17 252 249 52 M25x1.5p-6H
EBK 25 -10/2 1.05 10.2 8.9 A 363 190 225 150 185 258 120 40 4 x 17 252 249 52 M25x1.5p-6H
EBK 25 -13/2 1.05 10.2 8.9 A 363 190 225 150 185 258 120 40 4 x 17 252 249 52 M25x1.5p-6H
EBK 30 -16/2 1.8 23 20 A 459 200 250 160 210 294 140 40 4 x 17 295 287 94 M25x1.5p-6H
EBK 30 -20/2 1.8 23 20 A 459 200 250 160 210 294 140 40 4 x 17 295 287 94 M25x1.5p-6H
EBK 40 -30/2 2.5 35 31 A 542 220 320 170 270 358 170 60 4 x 26 326 349 122 M25x1.5p-6H

4-pole — 1,440/1,728 rpm — 50/60 Hz

Issue G pages 18–19. ● = 50 Hz only; ◇ = 60 Hz only. Specify the required temperature class at order. Current columns retain their voltage/frequency conditions; working moment is printed Kg.cm. ×2. Dimensional letters refer to the original figure; N is a cable-entry thread and thermistor entry is shown separately. Model prefixes on continuation rows follow the source spread.

Ratings and model designations — PDF page 18

Frame/model designation (frequency-only symbol retained) Temperature Class (source label) Centrifugal Force Kg (source label) Centrifugal Force Newtons Working Moment Kg.cm. (x2) / 50Hz Working Moment Kg.cm. (x2) / 60Hz Weight Kg / 50Hz Weight Kg / 60Hz Watts Input Watts Output Full Load Current / 400V / 50Hz (current unit not printed)
EBK 20 -5/4 T3 or T4 500 4905 43.1 29.9 26.5 25.5 450 250 0.97
EBK 25 -7.5/4 T3 or T4 750 7357 64.7 44.9 46 45 675 500 1.32
EBK 25 -11/4 T3 or T4 1100 10790 94.9 65.9 47 46 675 500 1.32
EBK 25 -14/4 T3 or T4 1400 13735 121 84.0 50 48 675 500 1.32
EBK 30 -18/4 T3 or T4 1800 17658 155 107 76 73 1335 1150 2.50
EBK 30 -25/4 T3 or T4 2500 24525 216 150 79 75 1335 1150 2.50
EBK 40 -35/4 T3 or T4 3500 34335 302 209 115 110 2150 1800 3.70
EBK 45 -45/4 T3 or T4 4500 44145 388 269 165 159 3050 2685 5.30
EBK 50 -55/4 T3 or T4 5500 53955 474 329 190 183 3740 3350 6.40
EBK 50 -75/4 T3 or T4 7500 73575 647 449 230 221 5280 4800 8.60
EBK 60 -95/4 T3 or T4 9500 93195 820 569 340 330 8410 7750 12.90

Electrical continuation and dimensions — PDF page 19

Model — facing-page source row Full Load Current / 460V / 60Hz (current unit not printed) Starting Current / 400V / 50Hz (current unit not printed) Starting Current / 460V / 60Hz (current unit not printed) Fig. Dimension A / mm as table heading Dimension B / mm as table heading Dimension C / mm as table heading Dimension D / mm as table heading Dimension E / mm as table heading Dimension F / mm as table heading Dimension G / mm as table heading Dimension H / mm as table heading Dimension J / mm as table heading Dimension K / mm as table heading Dimension L / mm as table heading Dimension M / mm as table heading Cable entry N / thread designation as printed
EBK 20 -5/4 0.88 3.6 3.1 A 330 150 171 110 140 185 87 16 4 x 14 186 179 74 M20x1.5p-6H
EBK 25 -7.5/4 1.22 8.7 7.6 A 413 190 225 150 185 258 120 40 4 x 17 252 249 82 M25x1.5p-6H
EBK 25 -11/4 1.22 8.7 7.6 A 413 190 225 150 185 258 120 40 4 x 17 252 249 82 M25x1.5p-6H
EBK 25 -14/4 1.22 8.7 7.6 A 413 190 225 150 185 258 120 40 4 x 17 252 249 82 M25x1.5p-6H
EBK 30 -18/4 2.2 24.0 21 A 459 200 250 160 210 294 140 40 4 x 17 295 287 94 M25x1.5p-6H
EBK 30 -25/4 2.2 24.0 21 A 459 200 250 160 210 294 140 40 4 x 17 295 287 94 M25x1.5p-6H
EBK 40 -35/4 3.3 32.0 28 A 542 220 320 170 270 358 170 60 4 x 26 326 349 122 M25x1.5p-6H
EBK 45 -45/4 4.8 57.0 50 A 670 298 357 248 305 378 175 60 4 x 26 355 364 152 M25x1.5p-6H
EBK 50 -55/4 5.7 74.0 64 A 714 298 357 248 305 430 203 60 6 x 26 402 418 152 M25x1.5p-6H
EBK 50 -75/4 7.6 88.0 77 A 714 298 357 248 305 430 203 60 6 x 26 402 418 152 M25x1.5p-6H
EBK 60 -95/4 11.3 190 165 A 820 295 454 235 394 490 233 70 6 x 26 480 478 191 M32x1.5p-6H

6-pole — 960/1,152 rpm — 50/60 Hz

Issue G pages 20–21. ● = 50 Hz only; ◇ = 60 Hz only. Specify the required temperature class at order. Current columns retain their voltage/frequency conditions; working moment is printed Kg.cm. ×2. Dimensional letters refer to the original figure; N is a cable-entry thread and thermistor entry is shown separately. Model prefixes on continuation rows follow the source spread.

Ratings and model designations — PDF page 20

Frame/model designation (frequency-only symbol retained) Temperature Class (source label) Centrifugal Force Kg (source label) Centrifugal Force Newtons Working Moment Kg.cm. (x2) / 50Hz Working Moment Kg.cm. (x2) / 60Hz Weight Kg / 50Hz Weight Kg / 60Hz Watts Input Watts Output Full Load Current / 400V / 50Hz (current unit not printed)
EBK 25 -4/6 T3 or T4 400 3924 77.6 53.8 46 43 747 510 1.61
EBK 25 -8/6 T3 or T4 800 7848 155 107.6 51 48 747 510 1.61
EBK 25 -11/6 T3 or T4 1100 10790 213 148 59 56 747 510 1.61
EBK 30 -14/6 T3 or T4 1400 13734 271 188 90 85 1165 900 3.0
EBK 30 -18/6 T3 or T4 1800 17658 349 242 95 90 1165 900 3.0
EBK 40 -27/6 T3 or T4 2700 26487 524 364 130 122 2290 1800 5.0
EBK 45 -42/6 T3 or T4 4200 41200 815 566 195 182 2690 2310 6.3
EBK 50 -60/6 T3 or T4 6000 58860 1164 808 250 231 4530 4000 8.8
EBK 50 -75/6 T3 or T4 7500 73575 1455 1010 275 256 4530 4000 8.8
EBK 60 -105/6 T3 or T4 10500 103000 2037 1414 449 426 6630 6200 11.2
EBK 75 -150/6 T3 or T4 15000 147150 2910 2020 490 460 10820 10000 18.0

Electrical continuation and dimensions — PDF page 21

Model — facing-page source row Full Load Current / 460V / 60Hz (current unit not printed) Starting Current / 400V / 50Hz (current unit not printed) Starting Current / 460V / 60Hz (current unit not printed) Fig. Dimension A / mm as table heading Dimension B / mm as table heading Dimension C / mm as table heading Dimension D / mm as table heading Dimension E / mm as table heading Dimension F / mm as table heading Dimension G / mm as table heading Dimension H / mm as table heading Dimension J / mm as table heading Dimension K / mm as table heading Dimension L / mm as table heading Dimension M / mm as table heading Cable entry N / thread designation as printed
EBK 25 -4/6 1.46 7.0 6.1 A 413 190 225 150 185 258 120 40 4 x 17 252 249 82 M25x1.5p-6H
EBK 25 -8/6 1.46 7.0 6.1 A 493 190 225 150 185 258 120 40 4 x 17 252 249 122 M25x1.5p-6H
EBK 25 -11/6 1.46 7.0 6.1 A 493 190 225 150 185 258 120 40 4 x 17 252 249 122 M25x1.5p-6H
EBK 30 -14/6 2.7 15.0 13.0 A 539 200 250 160 210 294 140 40 4 x 17 295 287 134 M25x1.5p-6H
EBK 30 -18/6 2.7 15.0 13.0 A 539 200 250 160 210 294 140 40 4 x 17 295 287 134 M25x1.5p-6H
EBK 40 -27/6 4.6 25.0 22.0 A 542 220 320 170 270 358 170 60 4 x 26 326 349 122 M25x1.5p-6H
EBK 45 -42/6 5.8 44.0 38.0 A 670 298 357 248 305 378 175 60 4 x 26 355 364 152 M25x1.5p-6H
EBK 50 -60/6 7.9 61.0 53.0 A 714 298 357 248 305 430 203 60 6 x 26 402 418 152 M25x1.5p-6H
EBK 50 -75/6 7.9 61.0 53.0 A 810 298 357 248 305 430 203 60 6 x 26 402 418 202 M25x1.5p-6H
EBK 60 -105/6 10.0 108 94 A 820 295 454 235 394 490 233 70 6 x 26 480 478 191 M32x1.5p-6H
EBK 75 -150/6 16.0 230 200 A 906 295 454 235 394 490 233 70 6 x 31 480 478 235 M32x1.5p-6H

8-pole — 720/864 rpm — 50/60 Hz

Issue G pages 22–23. ● = 50 Hz only; ◇ = 60 Hz only. Specify the required temperature class at order. Current columns retain their voltage/frequency conditions; working moment is printed Kg.cm. ×2. Dimensional letters refer to the original figure; N is a cable-entry thread and thermistor entry is shown separately. Model prefixes on continuation rows follow the source spread.

Ratings and model designations — PDF page 22

Frame/model designation (frequency-only symbol retained) Temperature Class (source label) Centrifugal Force Kg (source label) Centrifugal Force Newtons Working Moment Kg.cm. (x2) / 50Hz Working Moment Kg.cm. (x2) / 60Hz Weight Kg / 50Hz Weight Kg / 60Hz Watts Input Watts Output Full Load Current / 400V / 50Hz (current unit not printed)
EBK 30 -7.5/8 T3 or T4 750 7357 259 180 90 85 730 500 2.3
EBK 30 -10/8 T3 or T4 1000 9810 345 239 95 90 730 500 2.3
EBK 40 -15/8 ● T3 or T4 1500 14715 517 - 130 - 1530 1100 3.6
EBK 40 -17/8 ◇ T3 or T4 1700 16677 - 406 - 122 1530 1100 -
EBK 45 -24/8 T3 or T4 2430 23838 838 581 200 185 2465 2000 6.1
EBK 50 -35/8 ● T3 or T4 3500 34335 1207 - 295 - 3780 3300 8.6
EBK 50 -45/8 T3 or T4 4500 44145 1552 1077 317 303 3780 3300 8.6
EBK 50 -55/8 ● T3 or T4 5500 53955 1897 - 343 - 3780 3300 8.6
EBK 50 -57/8 ◇ T3 or T4 5700 55917 - 1362 - 327 3780 3300 -
EBK 60 -65/8 ● T3 or T4 6500 63765 2242 - 425 - 5645 4900 13.3
EBK 60 -70/8 ◇ T3 or T4 7000 68670 - 1673 - 404 5645 4900 -
EBK 60 -90/8 T3 or T4 9000 88290 3105 2155 475 450 5645 4900 13.3
EBK 75 -150/8 T3 or T4 15000 147150 5174 3592 640 580 8940 7750 20.1

Electrical continuation and dimensions — PDF page 23

Model — facing-page source row Full Load Current / 460V / 60Hz (current unit not printed) Starting Current / 400V / 50Hz (current unit not printed) Starting Current / 460V / 60Hz (current unit not printed) Fig. Dimension A / mm as table heading Dimension B / mm as table heading Dimension C / mm as table heading Dimension D / mm as table heading Dimension E / mm as table heading Dimension F / mm as table heading Dimension G / mm as table heading Dimension H / mm as table heading Dimension J / mm as table heading Dimension K / mm as table heading Dimension L / mm as table heading Dimension M / mm as table heading Cable entry N / thread designation as printed
EBK 30 -7.5/8 2.2 10 9 A 539 200 250 160 210 294 140 40 4 x 17 295 287 134 M25x1.5p-6H
EBK 30 -10/8 2.2 10 9 A 539 200 250 160 210 294 140 40 4 x 17 295 287 134 M25x1.5p-6H
EBK 40 -15/8 ● - 13 - A 542 220 320 170 270 358 170 60 4 x 26 326 349 122 M25x1.5p-6H
EBK 40 -17/8 ◇ 3.3 - 12 A 542 220 320 170 270 358 170 60 4 x 26 326 349 122 M25x1.5p-6H
EBK 45 -24/8 6.47 23 24 A 670 298 357 248 305 378 175 60 4 x 26 355 364 152 M25x1.5p-6H
EBK 50 -35/8 ● - 55 - A 714 298 357 248 305 430 203 60 6 x 26 402 418 152 M25x1.5p-6H
EBK 50 -45/8 7.8 55 48 A 810 298 357 248 305 430 203 60 6 x 26 402 418 202 M25x1.5p-6H
EBK 50 -55/8 ● - 55 - A 810 298 357 248 305 430 203 60 6 x 26 402 418 202 M25x1.5p-6H
EBK 50 -57/8 ◇ 7.8 - 48 A 810 298 357 248 305 430 203 60 6 x 26 402 418 202 M25x1.5p-6H
EBK 60 -65/8 ● - 98 - A 820 295 454 235 394 490 233 70 6 x 26 480 478 191 M32x1.5p-6H
EBK 60 -70/8 ◇ 12.1 - 85 A 820 295 454 235 394 490 233 70 6 x 26 480 478 191 M32x1.5p-6H
EBK 60 -90/8 12.1 98 85 A 907 295 454 235 394 490 233 70 6 x 26 480 478 235 M32x1.5p-6H
EBK 75 -150/8 18.1 123 107 A 1127 295 454 235 394 490 233 70 6 x 31 480 478 345 M32x1.5p-6H

Fixing and maintenance reference

The linked P3085 Issue B fixing-bolt guide describes rigid support, static deflection no more than 0.2 mm at maximum centrifugal force, clean metal-to-metal mating surfaces flat within 0.2 mm, and 50 mm clearance. Confirm the mounting system and fasteners for the selected vibrator before applying its table. It specifies grade 8.8 bolts, grade 8 self-locking nuts and hardened plain washers under both head and nut. Tighten the nut with a calibrated torque wrench; do not reuse bolts or nuts. The torque values apply to dry black bolts under the guide's stated residual-oil condition. Plated or lubricated fasteners need the supplier's advice. Asterisks indicate the torque-multiplier requirement. The alternative half-turn method requires the specified high-strength nut/bolt/washer arrangement and full original procedure, not an ordinary nut substituted into that method. At least two threads must protrude. Retorque after four hours, seven days and one month, then regularly; stop and inspect immediately if abnormal noise occurs. The complete drawings and procedure remain in the linked guide.

Mounting structure limits — PDF page 4

Source row Source label/context Source value
1 Static deflection at maximum centrifugal force Not exceeding0.2mm
2 Clearance to surrounding structure At least50mm
3 Running diagram label 0.2mm MAX

Mating-surface requirements and diagram labels — PDF page 5

Source row Source label/context Source value
1 Mounting surface flatness Within0.2mm
2 Diagram maximum gap labels 0.2mm MAX
3 Bolt-head mounting diagram 0.2mm MAX OUT OF PARALLEL
4 Bearing housing flanges ENSURE CLEARANCE UNDER BEARING HOUSING FLANGES
5 Vibrator foot NUT & WASHER FLAT AGAINST VIBRATOR FOOT

Dry black bolt tightening torque — PDF page 6

Source row Bolt size Torque Nm; Setscrews/Bolts Graade8.8
1 M8 27
2 M10 56
3 M12 96
4 M16 242
5 M20 473
6 M24 818
7 M30 1634*
8 M36 2854*

Half-turn figure component labels — PDF page 7

Source row Reference Source label
1 PSN/661 High Strength nut
2 PSN/612 Hardened washer under bolt head and nut
3 PSN/780 High strength bolt

Running checks — PDF page 7

Source row Time or trigger Source action
1 After first4hours operation Re-torque bolts
2 After seven days Re-torque bolts
3 After one month Re-torque bolts
4 After initial period Continue bolt-tightness checks as regular maintenance
5 Abnormal noise between checks Immediately switch machine off and check bolt tightness

Selection checks and source differences

The feature list cites BS4999 / AS1359, while the page introduction cites BS4999 / IEC60034. These source references are not treated as a new combined certification.

The product page says IP66, but the brochure distinguishes IP66 enclosure and IP65 terminal box. Confirm the supplied assembly and glands.

The brochure ties 160°C thermistor connection to variable-speed T3 duty and 120°C thermistors to T4; the website wording is less explicit. Both contexts are retained.

The certificate temperature row carries ** with no explanatory footnote visible on that page. The selected certificate must resolve conditions; no meaning is invented.

The attached fixing-bolt document is not a dedicated EBK flameproof installation/repair manual. Flamepath, gland, sensor and inverter requirements cannot be completed from BLz or ULBK manuals by analogy.

Product documents

Our company certificates and conditions of sale remain separate from the selected product’s ratings and approvals.

Talk to our team about your application, supply, motor rating and configuration.