- Location: Christchurch, New Zealand
- Industry: Timber and joinery
- Application: Dust Extraction Fan
Project: F510 37 kW drive replaces a soft starter on a dust extraction fan, Christchurch
A Christchurch joinery faced challenges after moving to a new factory. Their existing dust extraction unit was not performing adequately in the new environment. This impacted the health and safety of the staff due to insufficient dust extraction rates.
The primary challenge was the limitation of the existing dust extraction unit, which operated on a soft starter limiting the fan speed to 50Hz. This was insufficient for the new premises, necessitating a solution to enhance extraction rates.
Solution:
Installing a TECO F510 Variable Speed Drive (VSD)
The TECO F510 VSD allowed the customer to safely increase the fan speed to 60Hz, effectively meeting the required extraction rates.
Compact and Durable Design: The TECO F510 37kW features an IP55 design, enabling installation directly on the wall of their building without the need for additional costs or space for an electrical cabinet.
Benefits to the Joinery:
- Improved Extraction Rates: The new setup improved dust extraction without needing
- mechanical modifications to the existing fan.
- Cost-Effective Solution: The TECO F510 VSD allowed the customer to meet their new extraction requirements without changing the fan or mechanical installation.
Results:
The installation of the TECO F510 VSD led to significantly improved dust extraction rates, enhancing the health and safety of the staff at the joinery. This solution provided a cost-effective and efficient way to address their challenges in the new premises.
For more information on how TECO can help improve your operations, please Click here
Common questions:
Can a soft starter change fan speed? No. A soft starter controls the start and the stop, then runs the motor at full supply frequency. To run a fan faster or slower than that, you need a variable speed drive.
Can a 50 Hz motor run at 60 Hz on a drive? Yes, within the mechanical limits of the motor and the driven equipment, and provided the motor has enough power margin for the load at the higher speed.
Why choose an IP55 drive for a fan? It can be installed next to the equipment in dusty or damp areas without a separate enclosure, which saves cabinet cost and floor space.