TECO 3 Phase Electric Motors

Enquire About Your Motor

Image

Model

kW

Poles

Phases

IP Rating

TECO MAXeV4 IE4 Super Premium Efficiency
TECO MAXeV4 IE4 Super Premium Efficiency

0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 22, 30, 37, 45, 55, 75, 90, 110, 132, 150, 160, 185

2, 4, 6

3 Phase

66

TECO MAXe3 MINING Premium Efficiency
TECO MAXe3 MINING Premium Efficiency

0.18, 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 22, 30, 37, 45, 55, 75, 90, 110, 132, 150, 185

2, 4, 6, 8

3 Phase

66

TECO Te3 Cast Iron 3 Phase
TECO Te3 Cast Iron 3 Phase

0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 10, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90, 110, 132, 160, 200, 250, 315, 355, 400, 450, 500

2, 4, 6, 8

3 Phase

55

TE3-SEVERE-DUTY-THREE-PHASE-FOOT-MOUNT-1-1
TECO Te3 Severe Duty Cast Iron 3 Phase

0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 10, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90, 110, 132, 160, 200, 250, 315, 355, 400, 450, 500

2, 4, 6, 8

3 Phase

66

TECO AFJE MAXe3 Mining
TECO AFJE MAXe3 Mining

110, 150, 185, 220, 250, 260, 300, 315, 375, 450

4, 6, 8

3 Phase

66

TECO AFJN MAXe3 Mining
TECO AFJN MAXe3 Mining

—

—

—

66

How to choose a 3 phase electric motor

A three-phase motor is selected in four steps, and the order matters. Start with the load and the duty: the kW the driven machine needs at its speed, the duty type (S1 continuous for pumps, fans and conveyors), the starts per hour and the load inertia. Repeated starts heat the rotor faster than it cools, and that sets the permitted starts on a given frame.

The frame size follows from the kW and the pole number through IEC 60072-1, which fixes shaft height, shaft diameter and foot or flange dimensions, so a TECO MAXeV4 drops onto the base and coupling of the IE2 or IE3 motor it replaces. Then the IP rating: IP66 on the TECO Te3 Severe Duty, TECO MAXe3 Mining and TECO MAXeV4 for washdown, coal dust and outdoor duty. Last, the efficiency class: IE3 on the Te3 and MAXe3 Mining, IE4 on the MAXeV4 from 0.75 to 315 kW.

Check the insulation and ambient together: Class F with Class B rise on the Te3, rated to 50°C ambient; Class H on the MAXe3 Mining, with full output to 60°C ambient with a 1.2 service factor at 40°C. If a variable speed drive is going on the motor, our stock motors are rated 1,600 V peak and 6,500 V/µs on Class F and 2,200 V and 8,500 V/µs on Class H. Send us the nameplate of the motor being replaced, or the load data, and we can confirm the frame.

3 phase motor FAQs

How do I choose a three-phase motor?

Load kW and speed first, then duty and starts per hour, then the IEC 60072-1 frame that follows from kW and poles, then IP rating and efficiency class. For a replacement, the nameplate of the old motor gives the frame; TECO MAXeV4 motors match IE2 and IE3 frame and shaft dimensions.

What is the frame size of a three-phase motor?

The IEC frame number fixes the shaft height and mounting dimensions: a frame 160 motor has a 160 mm shaft centre height from the base of the feet. kW and pole number set the frame under IEC 60072-1, and TECO MAXeV4 motors cover frames 80 to 355L.

Can a three-phase motor run on single phase?

Yes, up to 2.2 kW through a variable speed drive with single-phase input and three-phase output: the TECO E510s, TECO L510s and TECO E710 take 200 to 240 V single phase input. Above that, or without a drive, specify a single-phase motor from the TECO single-phase range, available up to 7.5 kW.

Are three-phase motors more efficient?

In the sizes where both exist, a three-phase motor reaches higher efficiency classes: TECO Te3 and MAXe3 Mining motors are IE3, and the TECO MAXeV4 is IE4 Super Premium Efficiency to IEC 60034-30-1 across 0.75 to 315 kW. Single-phase motors are not rated in these classes in the same way and are traditionally not very efficient.

Can any three-phase motor be used with a VSD?

Any standard induction motor whose insulation withstands the drive’s voltage pulses. TECO low voltage stock motors are rated 1,600 V peak and 6,500 V/µs on Class F and 2,200 V and 8,500 V/µs on Class H. On larger motors we recommend fitting a shaft earthing brush at the drive end and an insulated bearing or housing at the non-drive end.

What IP rating does my motor need?

IP55 covers indoor plant rooms and most general factory applications; IP66 covers washdown, coal and mineral dust, and arduous outdoor duty. TECO Te3 is IP55 (IP56 and IP66 on request); TECO Te3 Severe Duty, MAXe3 Mining and MAXeV4 are all IP66 as standard, and the MAXe3 Mining drains condensate through porous plugs.

Book a Consultation
Have questions or need assistance? Reach out to us through the contact form, and we’ll be happy to assist you.
This field is for validation purposes and should be left unchanged.
Drop files here or
Max. file size: 400 MB.