TECO Emotron V33 — Drives for Demanding Loads

Our Emotron V33 range is built around dynamic industrial duties such as cranes, crushers, mills and mixers. Direct torque control is intended to respond quickly to changing loads, with controlled starting and braking functions to suit the application.

Torque, speed and load control

The source describes torque boost for initial peak loads and vector braking for controlled stops. The catalogue separates closed-loop and open-loop performance; encoder-based operation requires the appropriate feedback hardware and configuration. Its accuracy and response illustrations are supplier claims under their stated conditions, not measured performance for an arbitrary machine.

Use the actual motor, inertia, speed range, overload cycle and stopping requirements when selecting a drive. Crane functions and brake-control parameters are not a complete lifting safety system. Continuous variable-speed operation, jog, torque control and mechanical brake control have distinct conditions in the manual. No curve points or unprinted torque/speed limits have been inferred.

The website names the V33 family; the manual uses JNVX, and individual sheets commonly use VFX. F33/JNFX/FDU sections in the shared catalogue remain separately labelled. V33's motor-current setting[224] is 25–150% of I_NOM; that parameter range is neither a general continuous-overload guarantee nor an F33 specification.

Configuration records

The collected website export contains 156 row associations across tables13 and 38, 78 rows each, with 156 PDF memberships to 78 distinct technical PDFs. Repeated links are consolidated by source hash while retaining every table/row relationship. Similar-looking PDFs remain distinct where their bytes or specifications differ.

The shared28-page catalogue and 208-page V33 manual retain their own rating and dimension schedules. The 525 V manual table includes the literal model label JNVX690-650; it has not been silently changed to another code. Similarly, a model appearing in a690 V table is not assumed to have a missing575 V rating.

Ratings, enclosures and installation

The shared F33/V33 2.0 catalogue has a 0.55–3000 kW, 230–690 V cover headline. Its individual schedules and on-request ranges differ by family and voltage. A headline or requested larger size does not establish a model's current, dimensions or availability. The manual identifies48, 52 and 69 supply families with their own operating ranges; a motor-voltage parameter range is not the drive's input-voltage rating.

The catalogue's normal-duty columns are 120% for one minute every ten minutes and heavy-duty columns 150% for one minute every ten minutes, at the stated40°C reference ambient. Maximum-current entries have an additional limited-time/drive-temperature qualification. Preserve kW at 400/525/690 V separately from hp at 460/575 V. Select by actual motor current and overload duty, rather than combining similarly named rows.

The range page describes robust IP54 steel construction. The family documents also show larger IP20 modules and IP54 cabinet arrangements. Dimensions, weight and cooling airflow are frame-, enclosure- and voltage-specific. A shared frame number does not make two voltage classes dimensionally equivalent. Parenthesised heights and blank mounting values remain as printed; original drawings define geometry.

The catalogue's normal operating environment is 0–40°C, non-condensing and protected from conductive dust and corrosive cooling air. Higher-temperature derating differs by model group. Altitude guidance distinguishes480 V drives up to 4, 000m from 690 V drives up to 2, 000m, with current derating above 1, 000m and coating requirements at the stated elevations. The source does not explicitly establish the same limits for 525 V models. No combined temperature/altitude rating is calculated.

Interfaces, accessories and braking

The removable control panel supports parameter transfer and copying. Configure engineering units, motor data, command sources, protection and automatic restart for the actual process. Display illustrations, symbolic defaults and communication-register ranges remain references; they are not live settings or a motor performance envelope.

The shared catalogue supports three option boards plus one communication option. Safe Stop on B/C/D consumes one of those option positions. Options include I/O, encoder, PTC/PT100, fieldbus/serial interfaces and an external control panel. Model and software compatibility, occupied slots and factory-fit requirements remain part of selection. Coated boards and liquid cooling are separately described options; the heat exchanger is not included in the liquid-cooling option.

The catalogue describes Category C3 filtering as standard under its stated80m motor-cable condition. C2 and extended filters have separate frame, voltage and environment limits. Follow the complete EMC installation and cable/filter guide. The shared catalogue explicitly limits its sine-wave filter to F33; it is not a V33 option merely because the catalogue is shared.

A brake chopper is an optional factory-fitted item and the catalogue says it cannot be retrofitted; its resistor is external. Vector braking, a brake chopper/resistor and a mechanical holding brake are different functions. DC-link connections and overshoot clamps have their own prerequisites. Do not assume braking or Safe Stop replaces the machine's required safety/holding arrangement.

Commissioning, maintenance and source limits

Use qualified personnel and the complete manual for protective earthing, RCD selection, supply/motor connections, fuses, cables, cooling, commissioning and maintenance. Safe Stop is not electrical isolation. The manual distinguishes its normal discharge wait from a malfunction condition requiring DC-link verification or a longer wait; these have not been collapsed into one universal delay. Isolate before motor insulation testing and follow the prescribed procedure.

The detailed reference sections retain parameter sets, motor/process control, I/O, logic, timers, alarms, diagnostics, maintenance, options, wiring annotations and model-specific technical tables. Graphs and wiring geometry remain in the originals. Historical UL840, DNV, CE and safety-standard statements are preserved as source claims, not a current certificate or machine acceptance.

Several datasheets repeat VFX48-2K5-54 in a component-name field despite a different model in the title. They also label input power factor as percent while printing0.95, and pair a vibration value in g with oz. Some high-voltage sheets state400–690 V input but0–480 V output. These fields remain source-specific and flagged; we do not silently correct the model, scale, units or voltage.

Both manuals contain a derating example that states a68 A motor but selects a drive with a calculated32.4 A capability. That example is inconsistent and must not be used as approved selection guidance. Other menu indices, cross-references, merged cells and undefined boundaries retain their original values and local audit notes. We have not inferred missing defaults or corrected part numbers by pattern.

Confirm your configuration

Tell us the motor nameplate data, supply, duty cycle, driven load, speed and stopping requirements, site conditions and control-system interfaces. We can then confirm the correct model, enclosure, options and approved drawings.

Catalogue — Technical Catalogue AC Drives cover — page 1

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 1

TECO V33/F33 2.0; cover range0.55–3000kW,230–690V.

Context: Cover range not a per-model rating or source edition date. Small product photograph details are outside this text rendition.

Catalogue — V33 2.0 overview — page 2

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 2

TECO V33 2.0 / High dynamics for demanding applications

UL 840

GOST R

Main features

• Robust and certified IP54 metal construction as standard offers cost- efficient installation close to the application. • All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements are fulfilled with 80 m motor cable. • Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load changes. • Soft starts minimize start currents and full motor overload capacity is available from standstill.

• UL (UL 840) and marine (DNV) approved standard drive. • Integrated vector braking ensures quick and controlled stops, increasing productivity and safety. • Speed controlled fans assures less noise, a more even drive temperature and higher drive efficiency.

• Module fuses included as standard for sizes above 300 A at 480 V and above 210 A at 690 V.

• Detachable multilingual control panel included as standard. Following languages are supported in the control panel: English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech and Turkish.

• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min. • Removable control panel with own memory means it is easy to transfer or copy settings. • Liquid cooled version available for sizes above 90 A.

The TECO V33, 2.0 AC drive optimizes your process and prevents damage and downtime. The combination of direct torque control, accurate speed control and efficient vector braking makes it the ideal solution for all dynamic applications, such as cranes, crushers, mills, mixers and centrifuges.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: UL 840, DNV, CE/GOST marks and EN-IEC 62061:2005 SIL2 / EN-ISO 13849-1:2006 are source claims only. No current approval, certification scope or engineered safety-system acceptance is asserted.

Context: Overview says above 90 A; detailed option includes E–K/F69–K69. Preserve both without resolving boundary eligibility for a 90 A model. Heat exchanger explicitly excluded; parallel-module dividing unit retained.

Context: StandardIP54 claim and frameI IP20 module photograph caption describe different presentation/configuration contexts. Do not turn the pictured IP20 module into a contradiction resolved by changing all ratings.

Catalogue — V33 typical power: 400/460 V — page 3

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 3

Sizes 900 kW - 2000 kW available on request

TECO V33, 2.0 Typical motor power at mains voltage 400 and 460 V

Note: calculate available 230 V motor power by multiplying the 400 V power value (kW) from table above with 0.575 or use motor rated current for drive selection. Example: JNVX48-046, 22 kW x 0.575 = 12.6 kW at 230 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: 400/460 V V33 table prints VJNVX48-046, whereas the example footnote uses JNVX48-046. Keep both literal identifiers; no silent model correction.

Context: Small-model V33 maximum-output-current values differ from F33 values. Separate families and source rows retained; do not deduplicate by equal normal/heavy-duty power.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Context: These footnotes print 40 apostrophe-C in the text layer/typography rather than consistently using a degree symbol. Preserve literal prose; reviewed header context identifies the source ambient-temperature condition.

Table conditions: V33 only; mains 400/460 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. V33 400/460 V source headings, 120% normal/150% heavy for 1 minute each 10 minutes, 40°C rating footnote and limited maximum current, with reviewer merged-frame/unit instructions.

V33 typical motor power at 400/460 V — PDF page 3

Model Maximum output current A * Normal duty power 400 V kW Normal duty power 460 V hp Normal duty rated current A Heavy duty power 400 V kW Heavy duty power 460 V hp Heavy duty rated current A Frame size
JNVX48-003 3.8 0.75 1 2.5 0.55 1 2.0 B
JNVX48-004 6.0 1.5 2 4.0 1.1 1.5 3.2 B
JNVX48-006 9.0 2.2 3 6.0 1.5 2 4.8 B
JNVX48-008 11.3 3 3 7.5 2.2 3 6.0 B
JNVX48-010 14.3 4 5 9.5 3 3 7.6 B
JNVX48-013 19.5 5.5 7.5 13.0 4 5 10.4 B
JNVX48-018 27.0 7.5 10 18.0 5.5 7.5 14.4 B
JNVX48-026 39 11 15 26 7.5 10 21 C
JNVX48-031 46 15 20 31 11 15 25 C
JNVX48-037 55 18.5 25 37 15 20 29.6 C
VJNVX48-046 69 22 30 46 18.5 25 37 C
JNVX48-061 92 30 40 61 22 30 49 D
JNVX48-074 111 37 50 74 30 40 59 D
JNVX48-090 108 45 60 90 37 50 72 E
JNVX48-109 131 55 75 109 45 60 87 E
JNVX48-146 175 75 100 146 55 75 117 E
JNVX48-175 210 90 125 175 75 100 140 E
JNVX48-210 252 110 150 210 90 125 168 F
JNVX48-228 300 110 200 228 90 150 182 F
JNVX48-250 300 132 200 250 110 150 200 F
JNVX48-300 360 160 250 300 132 200 240 G
JNVX48-375 450 200 300 375 160 250 300 G
JNVX48-430 516 220 350 430 200 250 344 H
JNVX48-500 600 250 400 500 220 350 400 H
JNVX48-600 720 315 500 600 250 400 480 I
JNVX48-650 780 355 550 650 315 400 520 I
JNVX48-750 900 400 600 750 355 500 600 I
JNVX48-860 1032 450 700 860 400 550 688 J
JNVX48-1000 1200 500 800 1000 450 650 800 J
JNVX48-1200 1440 630 1000 1200 500 800 960 K
JNVX48-1500 1800 800 1250 1500 630 1000 1200 K

Catalogue — V33 typical power: 525 V — page 4

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 4

Sizes 710 kW - 2200 kW available on request

TECO V33, 2.0 Typical motor power at mains voltage 525 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Small-model V33 maximum-output-current values differ from F33 values. Separate families and source rows retained; do not deduplicate by equal normal/heavy-duty power.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Table conditions: V33 only; mains 525 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. V33 525 V source headings and duty/40°C conditions with reviewer merged-frame/unit instructions.

V33 typical motor power at 525 V — PDF page 4

Model Maximum output current A * Normal duty power 525 V kW Normal duty rated current A Heavy duty power 525 V kW Heavy duty rated current A Frame size
JNVX52-003 3.8 1.1 2.5 1.1 2.0 B
JNVX52-004 6.0 2.2 4.0 1.5 3.2 B
JNVX52-006 9.0 3 6.0 2.2 4.8 B
JNVX52-008 11.3 4 7.5 3 6.0 B
JNVX52-010 14.3 5.5 9.5 4 7.6 B
JNVX52-013 19.5 7.5 13.0 5.5 10.4 B
JNVX52-018 27.0 11 18.0 7.5 14.4 B
JNVX52-026 39 15 26 11 21 C
JNVX52-031 46 18.5 31 15 25 C
JNVX52-037 55 22 37 18.5 29.6 C
JNVX52-046 69 30 46 22 37 C
JNVX52-061 92 37 61 30 49 D
JNVX52-074 111 45 74 37 59 D
JNVX69-090 108 55 90 45 72 F69
JNVX69-109 131 75 109 55 87 F69
JNVX69-146 175 90 146 75 117 F69
JNVX69-175 210 110 175 90 140 F69
JNVX69-210 252 132 210 110 168 H69
JNVX69-250 300 160 250 132 200 H69
JNVX69-300 360 200 300 160 240 H69
JNVX69-375 450 250 375 200 300 H69
JNVX69-430 516 300 430 250 344 I69
JNVX69-500 600 315 500 300 400 I69
JNVX69-600 720 400 600 315 480 J69
JNVX69-650 780 450 650 355 520 J69
JNVX69-750 900 500 750 400 600 K69
JNVX69-860 1032 560 860 450 688 K69
JNVX69-1000 1200 630 1000 500 800 K69

Catalogue — V33 typical power: 575/690 V — page 5

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 5

Sizes 1100 kW - 3000 kW available on request

TECO V33, 2.0 Typical motor power at mains voltage 575 and 690 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Table conditions: V33 only; mains 575/690 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. V33 575/690 V source headings and duty/40°C conditions with reviewer merged-frame/unit instructions.

V33 typical motor power at 575/690 V — PDF page 5

Model Maximum output current A * Normal duty power 575 V hp Normal duty power 690 V kW Normal duty rated current A Heavy duty power 575 V hp Heavy duty power 690 V kW Heavy duty rated current A Frame size
JNVX69-090 108 75 90 90 60 75 72 F69
JNVX69-109 131 100 110 109 75 90 87 F69
JNVX69-146 175 125 132 146 100 110 117 F69
JNVX69-175 210 150 160 175 125 132 140 F69
JNVX69-210 252 200 200 210 150 160 168 H69
JNVX69-250 300 250 250 250 200 200 200 H69
JNVX69-300 360 300 315 300 250 250 240 H69
JNVX69-375 450 350 355 375 300 315 300 H69
JNVX69-430 516 400 450 430 350 315 344 I69
JNVX69-500 600 500 500 500 400 355 400 I69
JNVX69-600 720 600 600 600 500 450 480 J69
JNVX69-650 780 650 630 650 550 500 520 J69
JNVX69-750 900 750 710 750 600 600 600 K69
JNVX69-860 1032 850 800 860 700 650 688 K69
JNVX69-900 1080 900 900 900 750 710 720 K69
JNVX69-1000 1200 1000 1000 1000 850 800 800 K69

Catalogue — V33 application challenges and solutions — page 6

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 6

The answer to a range of challenges Cranes

Crushers

Mixers

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Table conditions: Application-specific supplier challenge/solution/benefit claims. No independent quantified performance or safety validation.

V33 / Cranes — PDF page 6

Challenge TECO V33 solution Value
Starting with a heavy load is difficult and risky. Can lead to hoist load dips or jerks causing swinging load in travel motions Direct torque control, motor pre- magnetization and precise brake control gives instant yet soft start with heavy load. Shortened cycle times and increased safety. Less stress on equipment reduced maintenance costs and down time
Unsynchronized travel motions of a rail- mounted crane casus noisy operation and stress on wheels. Speed and position of wheels are fully synchronized. Crane rides parallel to the rail. Less maintenance and downtime. Less noise improves working conditions.
Crane is driven slowly when returning empty or with a light load. Valuable time is lost. Speed can be increased by operating the motor in the field weakening area. Reduced cycle times and optimized operation
Hoisting and grabbing cannot be controlled independently. Stress on ropes and longer cycle times. Hoisting and grabbing can be operated simultaneously. Grab can be opened/closed while being hoisted. Reduced cycle times. Hoisting while closing grab puts less stress on ropes. Reducing maintenance and downtime.
Braking with heavy load is difficult and risky. Can lead to jerks causing swinging load. Direct torque control and brake chopper smoothly reduce speed to zero before mechanical brake is activated. Increased safety. Less stress on equipment reduces maintenance and downtime
Operator starts braking earlier than necessary to stop the crane at end position. Increases cycle times and can lead to jerky movements. System automatically stops crane at end position. Operator can safely drive at full speed. Reduced cycle times and increased safety.

V33 / Crushers — PDF page 6

Challenge TECO V33 solution Value
High start currents require larger fuses and cables, or in mobile units larger generators. Causes stress on equipment and higher energy costs. Speed control reduces start current. Same fuses can be used as those required for the normal motor current, or a smaller generator. Lower investment and energy costs, extended equipment lifetime.
Abrupt load change or torque peak when starting heavily loaded crusher. Causes mechanical stress and false trips. Direct torque control adjusts the torque to handle load changes and overcome initial peak loads. Reliable operation without interruptions. Reduced mechanical stress and less downtime
Material that could cause damage gets into the crusher. Load curve protection function quickly detects deviation. Warning is sent or safety stop activated. Early warning allows preventive action before damage or breakdown.
Motor runs at same speed despite varying demand. Motor speed is continuously adapted to the amount and size of rock. Speed of feeder is adapted to load variations. Increased efficiency. Reduced maintenance cost.

V33 / Mixers — PDF page 6

Challenge TECO V33 solution Value
High start currents require larger fuses and cables, Causes stress on equipment and higher energy costs. Speed control reduces start current. Same fuses can be used as those required for the normal motor current, Lower investment and energy costs, extended equipment lifetime.
Difficult to determine when mixing process is ready Built-in shaft power monitor determines when viscosity is right. Optimized operation and higher product quality.
Motor runs at same speed despite varying demand. Speed is continuously adapted to viscosity level. Reduced mixing time and improved product quality. Reduced maintenance costs.
Process inefficiency due to e.g. a damaged or broken blade. Energy wasted, mechanical stress and risk of process failure Load curve protection function quickly detects deviation from normal load. Warning is sent or safety stop activated. Preventive action before damage or breakdown. No energy is lost and downtime is reduced.

Catalogue — F33 2.0 overview — page 7

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 7

TECO F33, 2.0 / Secure the flow and save energy

Main features

• Robust and certified IP54 metal construction as standard offers cost-efficient installation close to the application. • All drive sizes are delivered with built-in Category C3 EMC-filter as standard. C3 requirements are fulfilled with 80 m motor cable. • Soft starts minimize start currents and linear stops prevent water hammer. • One TECO F33 can control up to seven units without external control systems. • Energy saving function pauses the motor when it is not required to run to maintain pressure. • Efficiency is increased by setting the pump to run at full speed at certain intervals to rinse out sludge. • Speed controlled fans assures less noise, a more even drive temperature and higher efficiency. • Module fuses included as standard for sizes above 300 A at 480 V and above 210 A at 690 V. • Detachable multilingual control panel included as standard. Following languages are supported in the control panel: English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech and Turkish. • Operation parameters can be set in your process units, for example m3/min. and bar. • Removable control panel with own memory means it is easy to transfer or copy settings. • UL (UL 840) and marine (DNV) approved standard drive. • Liquid cooled version available for sizes above 90 A.

The TECO F33, 2.0 AC drive is specially developed for regulating flow and pressure. It continuously adapts motor speed to the level required, minimizing energy consumption and wear. A unique monitoring functionality protects your process from damage and unplanned downtime. Typical applications are pumps, fans, compressors and blowers.

UL 840

GOST R

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: UL 840, DNV, CE/GOST marks and EN-IEC 62061:2005 SIL2 / EN-ISO 13849-1:2006 are source claims only. No current approval, certification scope or engineered safety-system acceptance is asserted.

Context: Overview says above 90 A; detailed option includes E–K/F69–K69. Preserve both without resolving boundary eligibility for a 90 A model. Heat exchanger explicitly excluded; parallel-module dividing unit retained.

Context: StandardIP54 claim and frameI IP20 module photograph caption describe different presentation/configuration contexts. Do not turn the pictured IP20 module into a contradiction resolved by changing all ratings.

Catalogue — F33 typical power: 400/460 V — page 8

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 8

Sizes 900 - 2000 kW available on request

TECO F33, 2.0 Typical motor power at mains voltage 400 and 460 V

Note: calculate available 230 V motor power by multiplying the 400 V power value (kW) from table above with 0.575 or use motor rated current for drive selection. Example: JNFX48-046, 22 kW x 0.575 = 12.6 kW at 230 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Small-model V33 maximum-output-current values differ from F33 values. Separate families and source rows retained; do not deduplicate by equal normal/heavy-duty power.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Table conditions: F33 only; mains 400/460 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. F33 400/460 V source headings and duty/40°C conditions with reviewer merged-frame/unit instructions.

F33 typical motor power at 400/460 V — PDF page 8

Model Maximum output current A * Normal duty power 400 V kW Normal duty power 460 V hp Normal duty rated current A Heavy duty power 400 V kW Heavy duty power 460 V hp Heavy duty rated current A Frame size
JNFX48-003 3.0 0.75 1 2.5 0.55 1 2.0 B
JNFX48-004 4.8 1.5 2 4.0 1.1 1.5 3.2 B
JNFX48-006 7.2 2.2 3 6.0 1.5 2 4.8 B
JNFX48-008 9.0 3 3 7.5 2.2 3 6.0 B
JNFX48-010 11.4 4 5 9.5 3 3 7.6 B
JNFX48-013 15.6 5.5 7.5 13.0 4 5 10.4 B
JNFX48-018 21.6 7.5 10 18.0 5.5 7.5 14.4 B
JNFX48-026 31 11 15 26 7.5 10 21 C
JNFX48-031 37 15 20 31 11 15 25 C
JNFX48-037 44 18.5 25 37 15 20 29.6 C
JNFX48-046 55 22 30 46 18.5 25 37 C
JNFX48-061 73 30 40 61 22 30 49 D
JNFX48-074 89 37 50 74 30 40 59 D
JNFX48-090 108 45 60 90 37 50 72 E
JNFX48-109 131 55 75 109 45 60 87 E
JNFX48-146 175 75 100 146 55 75 117 E
JNFX48-175 210 90 125 175 75 100 140 E
JNFX48-210 252 110 150 210 90 125 168 F
JNFX48-228 300 110 200 228 90 150 182 F
JNFX48-250 300 132 200 250 110 150 200 F
JNFX48-300 360 160 250 300 132 200 240 G
JNFX48-375 450 200 300 375 160 250 300 G
JNFX48-430 516 220 350 430 200 250 344 H
JNFX48-500 600 250 400 500 220 350 400 H
JNFX48-600 720 315 500 600 250 400 480 I
JNFX48-650 780 355 550 650 315 400 520 I
JNFX48-750 900 400 600 750 355 500 600 I
JNFX48-860 1032 450 700 860 400 550 688 J
JNFX48-1000 1200 500 800 1000 450 650 800 J
JNFX48-1200 1440 630 1000 1200 500 800 960 K
JNFX48-1500 1800 800 1250 1500 630 1000 1200 K

Catalogue — F33 typical power: 525 V — page 9

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 9

Sizes 710 - 2200 kW available on request

TECO F33, 2.0 Typical motor power at mains voltage 525 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Small-model V33 maximum-output-current values differ from F33 values. Separate families and source rows retained; do not deduplicate by equal normal/heavy-duty power.

Context: F33 525 V table includes JNFX52-019 in frame C in addition to JNFX52-018 in frame B. Retain both; do not infer a matching V33 row.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Table conditions: F33 only; mains 525 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. F33 525 V source headings and duty/40°C conditions with reviewer merged-frame/unit instructions.

F33 typical motor power at 525 V — PDF page 9

Model Maximum output current A * Normal duty power 525 V kW Normal duty rated current A Heavy duty power 525 V kW Heavy duty rated current A Frame size
JNFX52-003 3.0 1.1 2.5 1.1 2.0 B
JNFX52-004 4.8 2.2 4.0 1.5 3.2 B
JNFX52-006 7.2 3 6.0 2.2 4.8 B
JNFX52-008 9.0 4 7.5 3 6.0 B
JNFX52-010 11.4 5.5 9.5 4 7.6 B
JNFX52-013 15.6 7.5 13.0 5.5 10.4 B
JNFX52-018 21.6 11 18.0 7.5 14.4 B
JNFX52-019 22 11 18 7.5 14.4 C
JNFX52-026 31 15 26 11 21 C
JNFX52-031 37 18.5 31 15 25 C
JNFX52-037 44 22 37 18.5 29.6 C
JNFX52-046 55 30 46 22 37 C
JNFX52-061 73 37 61 30 49 D
JNFX52-074 89 45 74 37 59 D
JNFX69-090 108 55 90 45 72 F69
JNFX69-109 131 75 109 55 87 F69
JNFX69-146 175 90 146 75 117 F69
JNFX69-175 210 110 175 90 140 F69
JNFX69-210 252 132 210 110 168 H69
JNFX69-250 300 160 250 132 200 H69
JNFX69-300 360 200 300 160 240 H69
JNFX69-375 450 250 375 200 300 H69
JNFX69-430 516 300 430 250 344 I69
JNFX69-500 600 315 500 300 400 I69
JNFX69-600 720 400 600 315 480 J69
JNFX69-650 780 450 650 355 520 J69
JNFX69-750 900 500 750 400 600 K69
JNFX69-860 1032 560 860 450 688 K69
JNFX69-1000 1200 630 1000 500 800 K69

Catalogue — F33 typical power: 575/690 V — page 10

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 10

Sizes 1100 - 3000 kW available on request

TECO F33 2.0 Typical motor power at mains voltage 575 and 690 V

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Normal 120% / heavy 150% duty is 1 minute every 10 minutes; maximum current has a limited-time/temperature condition; ratings are at 40 C. Preserve 400/525/690 V kW versus 460/575 V hp. On-request ranges do not supply specific extra models.

Context: These footnotes print 40 apostrophe-C in the text layer/typography rather than consistently using a degree symbol. Preserve literal prose; reviewed header context identifies the source ambient-temperature condition.

Table conditions: F33 only; mains 575/690 V. Normal duty 120% for 1 minute every 10 minutes; heavy duty 150% for 1 minute every 10 minutes. Maximum current is limited by time/drive temperature; rated data at 40 C ambient. Frame labels are printed merged source cells mapped to each model, not inferred. Power units vary by voltage and must not be interchanged.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. F33 575/690 V source headings and duty/40°C conditions with reviewer merged-frame/unit instructions.

F33 typical motor power at 575/690 V — PDF page 10

Model Maximum output current A * Normal duty power 575 V hp Normal duty power 690 V kW Normal duty rated current A Heavy duty power 575 V hp Heavy duty power 690 V kW Heavy duty rated current A Frame size
JNFX69-090 108 75 90 90 60 75 72 F69
JNFX69-109 131 100 110 109 75 90 87 F69
JNFX69-146 175 125 132 146 100 110 117 F69
JNFX69-175 210 150 160 175 125 132 140 F69
JNFX69-210 252 200 200 210 150 160 168 H69
JNFX69-250 300 250 250 250 200 200 200 H69
JNFX69-300 360 300 315 300 250 250 240 H69
JNFX69-375 450 350 355 375 300 315 300 H69
JNFX69-430 516 400 450 430 350 315 344 I69
JNFX69-500 600 500 500 500 400 355 400 I69
JNFX69-600 720 600 600 600 500 450 480 J69
JNFX69-650 780 650 630 650 550 500 520 J69
JNFX69-750 900 750 710 750 600 600 600 K69
JNFX69-860 1032 850 800 860 700 650 688 K69
JNFX69-900 1080 900 900 900 750 710 720 K69
JNFX69-1000 1200 1000 1000 1000 850 800 800 K69

Catalogue — F33 application challenges and solutions — page 11

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 11

The answer to a range of challenges Common to Pumps / Fans / Compressors & Blowers

Pumps

Fans

Compressors

Blowers

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Table conditions: Application-specific supplier challenge/solution/benefit claims. No independent quantified performance or safety validation.

F33 / Common pumps/fans/compressors/blowers — PDF page 11

Challenge TECO F33 solution Value
High start currents require larger fuses and cables. Causing stress on equipment and higher energy costs Speed control reduces start current. Same fuses can be used as those required for the normal motor current. Lower investment and energy costs. Extended equipment lifetime
Motor runs at same speed despite varying demands in pressure and flow or when no air is compressed PID function continuously adapts speed to required level. Sleep function can be activated when the motor dose not need to run. Optimized energy consumption and increased efficiency. Reduced maintenance costs. Quicker set-up.
Process inefficiency due to e.g. A blocked pipe, a valve not fully opened or a worn impeller. A blocked filter, a damper not fully opened or a broken belt. The compressor idling Load curve protection function quickly detects deviation from normal load. Warning is sent or safety stop activated. Optimized operation. Preventive action before damage. No energy is lost and downtime is reduced.

F33 / Pumps — PDF page 11

Challenge TECO F33 solution Value
Sludge buildup on impeller when pump operates at low speed or on prolonged standby. Reduces pump efficiency Automatic pump rinsing: Pump can be set to run at full speed for a period of time before returning to normal operation. Higher process efficiency and reduced maintenance costs.
Prolonged Dry-running, cavitation and over heating damage the pump causing downtime Load curve protection function detects deviation. Sends warning or activates safety stop Preventive action before damage. Extended equipment lifetime and reduced downtime
Water hammer damages the pump when stopped. Mechanical stress on pipes, valves, gaskets and seals. Smooth linear stops protect the equipment. Eliminates need for costly motorized valves. Reduced maintenance costs and less downtime. Extended equipment lifetime. Lower installation costs.

F33 / Fans — PDF page 11

Challenge TECO F33 solution Value
Draught causes turned off fan t o rotate the wrong way. Starting causes high current peaks and mechanical stress. Dan result in blown fuses and breakdown. Spin start ensures that the motor is picked up at its present speed and direction, gradually slowed to zero speed and then started in the right direction. Reduced cycle times, extended equipment lifetime and less downtime.
Regulating pressure/flow with dampers causes high energy consumption and equipment wear. Automatic regulation of pressure/flow with motor speed gives a more exact control. Optimized energy consumption and minimized impact on equipment.

F33 / Compressors — PDF page 11

Challenge TECO F33 solution Value
Compressor is damaged when cooling agent enters the compressor screw. Overload situation is quickly detected and safety can be activated to avoid breakdown. Extended equipment lifetime, reduced maintenance costs and downtime
Pressure is higher than needed causing leaks, stress on the equipment and excessive air use. Load curve protection function detects deviation. Warning is sent or safety stop activated. Preventive action before damage or breakdown. No energy is lost and downtime is reduced.

F33 / Blowers — PDF page 11

Challenge TECO F33 solution Value
Difficult to compensate for pressure fluctuations. Energy wasted and risk of production stop. PID function continuously adapts pressure to the level required Reliable operation and no energy wasted. Always keeps the required pressure.

Catalogue — General specifications and enclosure dimensions — page 12

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 12

Cooling airflow table applies if mounted in cabinet. Models300–1500 consist of2,3,4 or6paralleled power modules(PEBB-s) in standard enclosure.

Context: Parenthesised heights retained without inferred meaning. Two dimension tables kept separate by source frame family; no invented individual models from ranges. Source wording FDU in switching-frequency line retained.

Table conditions: Mains footnotes TN/IT supply;* parameter-selected nominal voltage. Preserve voltage-specific tolerance and source FDU label.

Table conditions: Source upper table;dashes are printed absence markers, not zeros. IP20/IP54 weight order retained; cabinet airflow model split026–031/037–046 retained.

Table conditions: Source lower table; same model-range numbers in upper table do not establish same size/voltage variant. No inferred dimensions for dashes.

General specifications — PDF page 12

Parameter/source family Source value
Mains JNVX/JNFX48* 230–480V** +10%/-15%(-10% at230V)
Mains JNVX/JNFX52* 440–525V** +10%/-15%
Mains JNVX/JNFX69* 500–690V** +10%/-15%
Mains frequency 45–65Hz
Input total power factor 0.95
Output voltage 0–Mains supply voltage
Output frequency 0–400Hz
Output switching frequency 3kHz(FDU adjustable1.5–6kHz)
Efficiency at nominal load models003–018 97%
Efficiency at nominal load models026–1500 98%

Dimensions upper table framesB–K — PDF page 12

Models Frame size IP20 H x W x D mm IP54 H x W x D mm Weight IP20/IP54 kg Airflow m³/hour
003 to018 B – 350(416) x203 x200 –/12.5 75
026 to046 C – 440(512) x178 x292 –/24 026–031=120,037–046=170
061 to074 D - 545(590) x220 x295 -/32 175
90 to109 E – 950 x285 x314 –/56 510
146 to175 E – 950 x285 x314 –/60 510
210 to250 F – 950 x345 x314 –/74 800
300 to375 G(2xE) 1036 x500 x390 2250 x600 x600 140/350 1020
430 to500 H(2xF) 1036 x500 x450 2250 x600 x600 170/380 1600
600 to750 I(3xF) 1036 x730 x450 2250 x900 x600 248/506 2400
860 to1000 J(2xH) 1036 x1100 x450 2250 x1200 x600 340/697 3200
1200 to1500 K(2xI) 1036 x1560 x450 2250 x1800 x600 496/987 4800

Dimensions lower table framesF69–K69 — PDF page 12

Models Frame size IP20 H x W x D mm IP54 H x W x D mm Weight IP20/IP54 kg Airflow m³/hour
90 to175 F69 – 1090 x345 x314 –/77 800
210 to375 H69(2xF69) 1176 x500 x450 2250 x600 x600 176/399 1600
430 to500 I69(3xF69) 1176 x730 x450 2250 x900 x600 257/563 2400
600 to650 J69(2xH69) 1176 x1100 x450 2250 x1200 x600 352/773 3200
750 to1000 K69(2xI69) 1176 x1560 x450 2250 x1800 x600 514/1100 4800

Catalogue — Environmental limits derating and V33 speed — page 13

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 13

Most TECO AC drives designed for maximum40°C ambient; higher temperatures conditional on table derating.

V33 speed static graph labels: n actual/ref,±0,01% of nnom,t. Dynamic illustration: torque/speed,5%,80ms and(5 x0,08s)/2=0,2%s. These are illustration labels, not a digitized response curve.

Context: Derating model groups remain literal source groups, including** wildcard. No combined altitude/temperature derating calculated. Source classes are supplier statements, not independently verified conformity.

Table conditions: Voltage-family altitude boundaries and size-specific vibration condition retained as printed; no inferred applicability to525V models.

Table conditions: Storage only; separate fromnormaloperation.

Table conditions: Two-modelgroup merged source cells preserved within eachrow. Dashes not substituted with rated temperatures.

Table conditions: Source performance claims, not tested values. Chart geometry remains in PDF.

Environmental normal operation — PDF page 13

Parameter Normal operation
Nominal ambient temperature 0°C–40°C
Atmospheric pressure 86–106kPa
Relative humidity,non-condensing 0–90%
Contamination IEC60721-3-3 No electrically conductive dust; cooling air clean and free from corrosive materials. Chemical gases3C2(coated boards3C3);solid particles3S2.
Vibrations IEC60068-2-6 sinusoidal:10<f<57Hz,0.075mm;57<f<150Hz,1g. SizesB,C,D:IEC60721-3-3 3M4(2–9Hz,3.0mm;9–20Hz,acc.1g(10m/s²)).
Altitude 0–1000m.480V AC drives:1%/100m rated-current derating up to4000m.690V AC drives:1%/100m rated-current derating up to2000m. Coated boards required2000–4000m.

Storage conditions — PDF page 13

Parameter Storage condition
Temperature -20 to+60°C
Atmospheric pressure 86–106kPa
Relative humidity,non-condensing 0–90%

Table1 ambient derating400–690V types — PDF page 13

Source model group IP20 max temperature IP20 possible derating IP54 max temperature IP54 possible derating
JNVX-JNFX**-003 to JNVX-JNFX**-074 – – 40°C -2.5%/°C to max+10°C(50°C)
JNVX-JNFX48-090 to JNVX-JNFX48-250;JNVX-JNFX69-090 to JNVX-JNFX69-175 – – 40°C -2.5%/°C to max+5°C(45°C)
JNVX-JNFX48-300 to JNVX-JNFX48-1500;JNVX-JNFX69-210 to JNVX-JNFX69-1000 40°C -2.5%/°C to max+5°C(45°C) 40°C -2.5%/°C to max+5°C(45°C)

V33 2.0 speed control performance — PDF page 13

Metric Mode Source value
Static accuracy(linearity) Closed loop 0.01% of nnom
Static accuracy(linearity) Open loop 0.1% of nnom
Dynamic accuracy(impact drop) Closed loop 0.2%sec(100% load step)
Dynamic accuracy(impact drop) Open loop 0.4%sec(100% load step)

Catalogue — Control performance and basic I/O — page 14

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 14

Source limitation: Source comparator and fraction typography unresolved; no inferred numeric interpretation.

V33 torque illustration labels:actual/ref,±3% ofTnom,t;dynamic Tref/Tact,10%,90%,1ms. Geometry not reconstructed.

Source cross-reference says User interface data on page15 for connection/default settings; physicalPDF16 printed15 instead contains fuse/cable table. Preserve reference mismatch.

Context: Digital-input impedance comparator before second3.3VDC is malformed in source. Readable firstcondition<3.3VDC:4.7kΩ and second3.3VDC:3.6kΩ preserved; second comparator left unresolved. Do not infer equality boundary.

Context: Analogue input nonlinearity glyphs read11/2 LSB; fraction spacing unclear. Retained as printed, not converted to decimal. Output impedance has stray subscript n after10Ω; retained in note.

Table conditions: Source open-loop wording retained even where unitcontext differs; no engineering correction.

Table conditions: Four differential analogue inputs. Preserve printed fraction form; no decimal interpretation.

Table conditions: Malformed second impedance comparator retained as unresolved, not guessed.

Table conditions: Two analogue outputs; switched range, not software setting ofanalogueinputs. Source stray n retained.

Table conditions: Source merged label split into voltage andshort-circuit fields by two distinct valueblocks; shared100mA budgetretained.

Table conditions: Literal source current/maximum voltage statement; no switching category inferred.

Table conditions: Source+10VD label retained; no silent spelling correction. Digital-output shared-current condition preserved.

V33 torque and F33 V/Hz performance — PDF page 14

Family/metric Mode/condition Source value
V33 torque static(linearity) Closed loop <3% ofTnom
V33 torque static(linearity) Open loop <3% for speeds10–100% ofrated and<10% atzero speed(% ofnnom)
V33 torque dynamic Closed & open loop 100% torque step rise time1ms
F33 V/Hz speed accuracy Slip frequency Approx.1% ofnnom
F33 V/Hz torque accuracy 20–100% speed Approx.5% ofTnom

Analogue inputs differential4channels — PDF page 14

Parameter Source value
Voltage/current 0–±10V/0–20mA via software setting
Max input voltage +30V
Input impedance 20kΩ(voltage),250Ω(current)
Resolution 11bits+sign
Hardware accuracy 0.5% type+1 1/2 LSB fsd
Non-linearity 11/2 LSB(as printed,fraction typography unclear)

Digital inputs8channels — PDF page 14

Parameter Source value
Input voltage High>9VDC,Low<4VDC
Max input voltage +30VDC
Input impedance <3.3VDC:4.7kΩ / second condition[operator unclear]3.3VDC:3.6kΩ
Signal delay ≤8ms

Analogue outputs2channels — PDF page 14

Parameter Source value
Output voltage/current 0–10V/0–20mA via switch
Max output voltage +15V @5mA continuous
Short-circuit current(∞) +15mA(voltage),+140mA(current)
Output impedance 10Ω(voltage),stray source subscript n
Resolution 10bit
Maximum load impedance forcurrent 500Ω
Hardware accuracy 1.9% type fsd(voltage),2.4% type fsd(current)
Offset 3LSB
Non-linearity 2LSB

Digital outputs2channels — PDF page 14

Parameter Source value
Output voltage High>20VDC @50mA,>23VDC open / Low<1VDC @50mA
Short-circuit current(∞) 100mA max(together with+24VDC)

Relay contacts3pcs — PDF page 14

Parameter Source value
Contacts 0.1–2A/Umax250VAC or42VDC

Reference voltages — PDF page 14

Source label/context Source value
+10VD +10VDC @10mA,short-circuit current+30mA max
-10VDC -10VDC @10mA
+24VDC +24VDC,short-circuit current+100mA max(together withDigitalOutputs)

Catalogue — Photo gallery and model/frame captions — page 15

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 15

Photo gallery

VFX/FDU48/52: Model 003 - 018 (B) VFX/FDU48/52: Model 026 - 046 (C) VFX/FDU48/52: Model 061 - 074 (D)

JNVX/JNFX48: Model 090 – 175(E) JNVX/JNFX48:Model 210 – 250 (F) JNVX/JNFX: Model600 – 750 (I) IP20 (module) JNVX/JNFX 69: Model 090 – 175 (F69)

VFX/FDU48: Model 300 - 500 (G and H) VFX/FDU48: Model 600 - 750 (I) VFX/FDU69: Model 210 - 375 (H69) VFX/FDU69: Model 430 - 500 (I69)

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Gallery and crane-option sections use VFX/FDU alongside JNVX/JNFX. Retain printed naming and frame associations without inventing a universal alias or claiming crane options for F33.

Context: StandardIP54 claim and frameI IP20 module photograph caption describe different presentation/configuration contexts. Do not turn the pictured IP20 module into a contradiction resolved by changing all ratings.

Catalogue — Fuses cable dimensions and glands IEC ratings — page 16

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 16

Use mains fuses typegL/gG conformingIEC269 or circuit breaker with similar characteristics. Checkequipment before installing glands; source says onlymetricglands will beused in due time.

Source defines Max.fuse as maximum fuse value still protecting ACdrive and upholding warranty. Fuse and cablecrosssection depend on application and must be determined in accordance with local regulations.

Power-terminal dimensions in models300–1500 can differ depending on customer specification.

Context: Printed model prefixes JNVX/JNFX and JVX/JNFX retained as printed; VFX/FDU cable cell wording preserved. No substituted model IDs. Source table is not a current installation design or warranty verification.

Table conditions: Expand only visible merged cells. Shared mains/motor gland cell duplicated into bothcolumns. Preserve printed prefixes,48/69 cable distinction and all dashes; no unprinted69cable for1200/1500. Application/local-regulation/customer-terminal qualifications remain essential.

Fuse cable and gland table — PDF page 16

Printed model Nominal input current A Maximum fuse A Maximum mains/motor cable cross-section supported mm² Mains gland/clamping mm Motor gland/clamping mm
JNVX/JNFX48-003 2.2 4 0.5–10 M32 opening M20+reducer(6–12) M32 opening M20+reducer(6–12)
JNVX/JNFX48-004 3.5 4 0.5–10 M32 opening M20+reducer(6–12) M32 opening M20+reducer(6–12)
JVX/JNFX48-006 5.2 6 0.5–10 M32 opening M20+reducer(6–12) M32 opening M20+reducer(6–12)
JVX/JNFX48-008 6.9 8 0.5–10 M32(12–20) M32 opening M25+reducer(10–14)
JNVX/JNFX48-010 8.7 10 0.5–10 M32(12–20) M32 opening M25+reducer(10–14)
JNVX/JNFX48-013 11.3 16 0.5–10 M32(16–25) M32(13–18)
JNVX/JNFX48-018 15.6 20 0.5–10 M32(16–25) M32(13–18)
JNVX/JNFX**-026 22 25 2.5–16 M32(15–21) M32(13–18)
JNVX/JNFX**-031 26 35 2.5–16 M32(15–21) M32(13–18)
JNVX/JNFX**-037 31 35 2.5–16 M40(19–28) M40(18–25)
JNVX/JNFX**-046 38 50 2.5–16 M40(19–28) M40(18–25)
JNVX/JNFX**-061 52 63 1–35 stranded wire;1–50 solid wire M50(27–35) M40(19–28)
JNVX/JNFX**-074 64 80 1–35 stranded wire;1–50 solid wire M50(27–35) M40(19–28)
JNVX/JNFX**-090 78 100 16–95 JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening
JNVX/JNFX**-109 94 100 16–95 JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening
JNVX/JNFX**-146 126 160 35–150 JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening
JNVX/JNFX**-175 152 160 35–150 JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening JNVXJNFX48:Ø17–42 cable flexible lead through orM50 opening;JNVXJNFX69:Ø23–55 cable flexible lead through M63 opening
JNVX/JNFX**-210 182 200 VFX/FDU48:35–240;VFX/FDU69:35–150 Ø23–55 cable flexible lead through orM63 opening Ø23–55 cable flexible lead through orM63 opening
JNVX/JNFX**-228 197 250 VFX/FDU48:35–240;VFX/FDU69:35–150 Ø23–55 cable flexible lead through orM63 opening Ø23–55 cable flexible lead through orM63 opening
JNVX/JNFX**-250 216 250 VFX/FDU48:35–240;VFX/FDU69:35–150 Ø23–55 cable flexible lead through orM63 opening Ø23–55 cable flexible lead through orM63 opening
JNVX/JNFX**-300 260 300 JNVX/JNFX48:(2x)35–240;JNVX/JNFX69:(2x)35–150 - -
JNVX/JNFX**-375 324 355 JNVX/JNFX48:(2x)35–240;JNVX/JNFX69:(2x)35–150 - -
JNVX/JNFX**-430 372 400 JNVX/JNFX48:(2x)35–240;JNVX/JNFX69:(3x)35–150 - -
JNVX/JNFX**-500 432 500 JNVX/JNFX48:(2x)35–240;JNVX/JNFX69:(3x)35–150 - -
JNVX/JNFX**-600 520 630 JNVX/JNFX48:(3x)35–240;JNVX/JNFX69:(4x)35–150 - -
JNVX/JNFX**-650 562 630 JNVX/JNFX48:(3x)35–240;JNVX/JNFX69:(4x)35–150 - -
JNVX/JNFX**-750 648 710 JNVX/JNFX48:(3x)35–240;JNVX/JNFX69:(6x)35–150
JNVX/JNFX**-860 744 800 JNVX/JNFX48:(4x)35–240;JNVX/JNFX69:(6x)35–150 - -
JNVX/JNFX**-900 795 900 JNVX/JNFX48:(4x)35–240;JNVX/JNFX69:(6x)35–150 - -
JNVX/JNFX**-1000 864 1000 JNVX/JNFX48:(4x)35–240;JNVX/JNFX69:(6x)35–150 - -
JNVX/JNFX**-1200 1037 1250 JNVX/JNFX48:(6x)35–240 - -
JNVX/JNFX**-1500 1296 1500 JNVX/JNFX48:(6x)35–240 - -

Catalogue — NEMA fuses and cable sizes — page 17

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 17

Fuses and cable dimensions according NEMA ratings

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Merged cell spanning 146/175 contains AWG 1–AWG 3/0 and AWG 4/0–300 kcmil on separate lines without a physical row divider. Preserve shared cell context; do not infer which line belongs uniquely to one model.

Context: New NEMA UL Class J / part / AWG data must coexist with prior IEC metric data, not overwrite it. Printed rows are catalogue guidance, not verified site cable/fuse sizing.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. NEMA scope only; do not replace prior IEC fuse/cable tables. No AWG-to-metric conversion inferred.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. NEMA table source scope and AWG values combined with reviewer no-conversion/no-IEC-substitution rule.

NEMA fuses and cable sizes / table 1 — PDF page 17

Model Input current Arms Mains fuse UL Class J TD A Mains fuse Ferraz-Shawmut type Cable cross-section range: mains and motor
JNVX/JNFX48-003 2.2 6 AJT6 AWG 20 - AWG 6
JNVX/JNFX48-004 3.5 6 AJT6 None
JNVX/JNFX48-006 5.2 6 AJT6 None
JNVX/JNFX48-008 6.9 10 AJT10 None
JNVX/JNFX48-010 8.7 10 AJT10 None
JNVX/JNFX48-013 11.3 15 AJT15 None
JNVX/JNFX48-018 16 20 AJT20 AWG 12 – AWG 4
JNVX/JNFX48-026 22 25 AJT25 None
JNVX/JNFX48-031 26 30 AJT30 None
JNVX/JNFX48-037 31 35 AJT35 None
JNVX/JNFX48-046 38 45 AJT45 None
JNVX/JNFX48-061 52 60 AJT60 AWG 12 - AWG 4
JNVX/JNFX48-074 65 80 AJT80 AWG 10- AWG 0
JNVX/JNFX48-090 78 100 AJT100 AWG 4 – AWG 3/0
JNVX/JNFX48-109 94 110 AJT110 None
JNVX/JNFX48-146 126 150 AJT150 AWG 1 – AWG 3/0 AWG 4/0 – 300 kcmil
JNVX/JNFX48-175 152 175 AJT175 None
JNVX/JNFX48-210 182 200 AJT200 AWG 3/0 – 400 kcmil
JNVX/JNFX48-228 197 250 AJT250 None
JNVX/JNFX48-250 216 250 AJT250 None
JNVX/JNFX48-300 260 300 AJT300 2 x AWG 4/0 – 2 x 300 kcmil
JNVX/JNFX48-375 324 350 AJT350 None
JNVX/JNFX48-430 372 400 AJT400 2 x AWG 3/0 – 2 x 400 kcmil
JNVX/JNFX48-500 432 500 AJT500 None
JNVX/JNFX48-600 520 600 AJT600 3 x AWG 4/0 – 3 x 300 kcmil
JNVX/JNFX48-650 562 600 AJT600 None
JNVX/JNFX48-750 648 700 A4BQ700 None
JNVX/JNFX48-860 744 800 A4BQ800 4 x AWG 4/0 – 4 x 300 kcmil
JNVX/JNFX48-1000 864 1000 A4BQ1000 None
JNVX/JNFX48-1200 1037 1200 A4BQ1200 6 x AWG 4/0 – 6 x 300 kcmil
JNVX/JNFX48-1500 1296 1500 A4BQ1500 None

Catalogue — User interface terminals and default functions — page 18

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 18

4 -20 mA 0 -10 V

Comm.options

Fieldbus option or PC

X1

+10 VD AnIn 1 AnIn 2

AnIn 3 AnIn 4

-10 VDC Common

DigIn 1:RunL DigIn 2:RunR

DigIn3 +24 VDC Common DigIn 4 DigIn 5 DigIn 6 DigIn 7

DigIn8:Reset*

RFI- filter

Optional**

Relay 3

Relay 1

Relay 2

Optional

Common AnOut 1 AnOut 2 DigOut 1 DigOut 2

Other options

Option boards

X2

X3

Trip

Ready

Motor

User interface data * = Default selection ** = Optional terminals X1: 78 - 79 for connection of Motor-PTC on sizes B, C and D.

All inputs and outputs are programmable.

Illustrated power-terminal labels: L1, L2, L3, PE; U, V, W; optional DC+, R, DC-. The drawing also labels optional X1 terminals 78 and 79. These are source labels only; wiring topology remains in the original diagram.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: All I/O is programmable. Keep X1/X2/X3 identities, default relay functions and N/C/N/O semantics. Motor-PTC 78–79 is optional only for B/C/D in this page; no wiring path reconstructed from artwork.

Context: Diagram text says +10 VD whereas terminal 1 table specifies +10 VDC. Both source statements retained; no new power-supply specification inferred.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. X1 terminals 1–22, X2 relays 31–43 and X3 relay51–52 retained. Functions are defaults and all I/O is programmable. Diagram topology is not reconstructed.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Printed X1/default I/O and X2/X3 relay groups combined with reviewer topology boundary. X2 source groups are 31/32/33 and 41/42/43; shorthand 31–43 must not imply terminals 34–40. X1 78/79 are optional Motor-PTC on sizes B/C/D, not normal table rows.

User interface terminals and default functions / table 1 — PDF page 18

Terminal number Name Default function
1 +10 V +10 VDC Supply voltage
2 AnIn1 Speed reference
3 AnIn2 Not used
4 AnIn3 Not used
5 AnIn4 Not used
6 -10 V -10VDC Supply voltage
7 Common Signal ground
8 DigIn 1 RunL
9 DigIn 2 RunR
10 DigIn 3 Not used
11 +24 V +24VDC Supply voltage
12 Common Signal ground
13 AnOut 1 Min speed to max speed
14 AnOut 2 0 to max torque
15 Common Signal ground
16 DigIn 4 Not used
17 DigIn 5 Not used
18 DigIn 6 Not used
19 DigIn 7 Not used
20 DigOut 1 Ready
21 DigOut 2 Brake/No trip
22 DigIn 8 Reset
31 N/C 1 Relay 1 output=Trip Active when the AC drive is in a TRIP condition. N/C is opened when the relay is active (valid for all relays) N/O is closed when the relay is active (valid for all relays)
32 COM 1 None
33 N/O 1 None
41 N/C 2 Relay 2 Output=Ready Active when the AC drive is ready to start
42 COM 2 None
43 N/O 2 None
51 COM 3 Relay 3 Output=Not used
52 N/O 3 None

Catalogue — Standard option boards — page 19

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 19

Standard options for TECO F33/V33 2.0

Support for 3 option boards plus 1 communication option.

I/O board 3 extra relay outputs (230 VAC/5 A NO/NC). 3 extra 24 V /3.2 kO (AC or DC) differential digital inputs, all programmable. Inputs providing 50 Vac,dc isolation between channels. Maximum 3 I/O boards can be built -in per AC drive. Part no. 01-3876-01

Encoder board Differential encoder input suitable for 5 V (TTL) or 24 V (HTL) incremental encoders, range 5-16384 pulses/ revolution. Inputs min 9 kO. Max frequency = 100 kHz. For single ended or differential type of encoders (A/B, A’/B’). Selectable encoder supply voltage output 5 VDC or 24 VDC. Part no. 01-3876-03

PTC/PT100 board 1 PTC isolated input conforming DIN 44081/44082. Max 6 PTC thermistors can be connected in series to PTC input. Also including 3 PT100 inputs, 2/3/4-wire, conforming EN 60751. Part no. 01-3876-08

CRIO board (VFX) Crane option board to control hoist or travel motions. Inputs for joystick control: supporting 4-step, motor potentiometer or analog reference joystick types. Inputs for slow down and end limits switches (2+2). All 12 digital inputs 24 V/5 kΩ (8 - 24V) DC. 2 relay outputs 250 V/2AAC, for mechanical brake and load deviation protection. Load dependent field weakening operation of hoists also supported. Part no. 01-3876-07

Crane interface (VFX) Isolated I/O interface for control signals between (existing) crane controls and crane option board (CRIO). • Available for 230 V/27 kΩ (120 - 250V) AC or 24 V /2.7 kQ (15 - 36 V) DC input signals. • LED indications for all inputs and outputs. • For DIN-rail mounting. • HxWxD = 125 x 150 x 50 mm Part no. 590059 (230 VAC) 590060 (24 VDC)

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Gallery and crane-option sections use VFX/FDU alongside JNVX/JNFX. Retain printed naming and frame associations without inventing a universal alias or claiming crane options for F33.

Context: I/O and encoder prose prints kO, and crane interface 24 V line prints kQ, while other lines use an omega symbol. Preserve source spellings and log ambiguity rather than silently rewriting resistance units.

Context: Source supports 3 option boards plus 1 communication option. Safe stop on B/C/D consumes 1 of 3 positions. Maximum 3 I/O boards does not override that occupied-slot condition.

Catalogue — Communication and coating options — page 20

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 20

Fieldbus - Profibus Fieldbus option module for Profibus DP or DP V1 communication. Use 9-pin D-sub connector. Baud rates: 9.6 kbits/s - 12 Mbits/s supported. Typical drive response time = 10 ms (not including any fieldbus delays). Part no. 01-3876-05

Fieldbus - DeviceNet Fieldbus option module for DeviceNet communication. Baud rates: 125 - 500 kbits/s supported. Typical drive response time = 10 ms (not including any fieldbus delays). Part no. 01-3876-06

Ethernet - Modbus/TCP Industrial Ethernet option module for Modbus/TCP protocol. RJ45 type connector. Baud rates: 10 or 100 Mbits/s supported. Typical drive response time = 10 ms (not including any fieldbus delays). Part no. 01-3876-09

RS232/RS485 isolated Isolated RS232/RS485 serial communication board. For Modbus/ RTU communication protocol. Baud rates: 2400 - 38400 bits/s supported. Typical drive response time = 10 ms (not including any fieldbus delays). Part no. 01-3876-04

Coated boards All drive boards are also available as coated, recommended e.g. for sewer pump applications (chlorine gases) or installations with occasional high humidity (if machine room installation or tropical climate). IEC60721-3-3 gases class 3C3, solid particles class 3S2.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: 10 ms response excludes fieldbus delay; baud rates, old protocol/software and part numbers are catalogue statements, not current availability/software compatibility verification.

Catalogue — Panels, cable glands and software — page 21

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 21

Control panel kit, incl. blank panel External control panel IP54 suitable for mounting on a cabinet door. This option is to be used in combination with a AC drive module ordered with a built-in control panel. Part no. 01-3957-01

Control panel kit, incl. control panel External control panel IP54 suitable for mounting on a panel door. This option is to be used in combination with a AC drive module ordered with a blank control panel. Part no. 01-3957-00

Handheld Control Panel 2.0 Handheld Control Panel - HCP 2.0 is a complete control panel , easy to connect to the AC drive, for temporary use during e.g. commissioning and service. The HCP has full functionality. It is possible to set parameters, view actual values and fault logger. It is also possible to copy parameter data from one AC drive to the HCP and then load this data to other AC drives. Part no. 01-5039-00 Complete with cable.

EmoSoftCom Connect a PC with a standard RS232 cable under the control panel on the front. EmoSoftCom PC software makes it possible to perform signal recordings and save/load parameter backup data, for example during service & maintenance. .

Glands for frame sizes B, C and D Gland kits are available for size B, C and size D. Metal EMC glands are used for motor and brake resistor cables.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: 10 ms response excludes fieldbus delay; baud rates, old protocol/software and part numbers are catalogue statements, not current availability/software compatibility verification.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions.

Panels, cable glands and software / table 1 — PDF page 21

Part number Current and gland range Frame size
01-4601-21 3 - 6A (M16 - M20) B
01-4601-22 8 - 10A (M16 - M25) None
01-4601-23 13 - 18A (M16 - M32) None
01-4399-01 26 - 31A (M12 - M32) C
01-4399-00 37 - 46A (M12 - M40) None
01-4833-00 61 - 74A (M20 - M50) D

Catalogue — Factory-mounted options — page 22

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 22

Factory mounted options for TECO F33/V33, 2.0 Brake chopper All Teco V33/F33 drives can be fitted with an optional built-in brake chopper. Brake choppers are rated for continues braking at drive rated load. This option cannot be after mounted. The brake resistor must be mounted outside the AC drive (see page 23 for Brake resistor option).

DC+/DC- connection DC+/DC- terminals for external connection of the Teco V33/F33 drive DC link. This option is required if using the Overshoot clamp.

Standby power supply Built-in standby power supply board. To be connected to external 24 V AC/ DC supply voltage. If the main power is switched off, the control board, control panel and the connected options, for example fieldbus communication, will continue to operate. Part no: 01-3954-00

Safe stop Extra built-in inputs and outputs for emergency stop circuit conforming with the norms EN-IEC 62061:2005 SIL2 and EN-ISO 13849-1:2006. Safe stop for size B, C and D (uses 1 of the 3 option positions) Safe stop for size E and up

Blank control panel Blank panel instead of control panel (to maintain IP54). Indication LED’s for Power, Run and Trip available.

PTC Factory mounted, isolated motor PTC input conforming to DIN44081/ 44082, available with size B, C and D. Use PTC/PT100 option board if additional inputs are needed.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: UL 840, DNV, CE/GOST marks and EN-IEC 62061:2005 SIL2 / EN-ISO 13849-1:2006 are source claims only. No current approval, certification scope or engineered safety-system acceptance is asserted.

Context: Source supports 3 option boards plus 1 communication option. Safe stop on B/C/D consumes 1 of 3 positions. Maximum 3 I/O boards does not override that occupied-slot condition.

Context: Brake chopper cannot be after-mounted and brake resistor is external. Overshoot clamp needs DC+/DC− connection; B to F(69) order condition retained. Do not present as universal retrofit availability.

Context: Brake text refers to page 23, but resistors are printed 25 / PDF 26. Choke/sine text refers to filter guide page 24, but the guide is printed 26 / PDF 27. Preserve original references and provide actual provenance.

Catalogue — EMC filters — page 23

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 23

EMC filter class C2 EMC filter according to EN61800- 3:2004 class C2 - 1st environment restricted distribution. For sizes B, C and D. Integrated inside the drive module. Note: EMC filter acc. to class C3 - 2nd environment included as standard in all drive units.

Extended options for TECO F33/V33 2.0

Extended EMC filter 90-650A EMC filter according to EN61800-3:2004 class C2 - 1st environment, restricted distribution. From frame size E. Rated voltage=480 V, 50/60 Hz. Max. 40 °C ambient temperature.

1=Screw terminal (protected) 2=Busbar terminals

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: JNVX/JNFX48-300 filter type is printed 3F480300.230 without the hyphen used in nearby types. Retain exact source code, no guessed replacement.

Context: IP20 superscript 1 and IP00 superscript 2 were parsed as IP201/IP002. Reviewed values explicitly separate footnote 1/2; raw originals and 12 before/after records retained. Footnote 1 = screw terminal (protected); 2 = busbar.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. External EMC filter: 480 V 50/60 Hz, maximum40 C, frame E upward, C2 first-environment restricted distribution. Superscripts1/2 are footnote markers, not IP201/IP002 classifications.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source external filter conditions 480 V/50–60 Hz/40°C/frame E upward/C2 restricted distribution with reviewer superscript interpretation; 1/2 are footnotes, not enclosure class digits.

EMC filters / table 1 — PDF page 23

Drive model Filter type Dimensions HxWxD mm Weight kg Enclosure with footnote marker
JNVX/JNFX48-090 3F480-100.230 325x150x107 7.1 IP20 [footnote 1]
JNVX/JNFX48-109 3F480-125.230 345x175x127 10 IP20 [footnote 1]
JNVX/JNFX48-146 3F480-150.230 375x175x135 10 IP20 [footnote 1]
JNVX/JNFX48-175 3F480-180.230 490x170x158 13.5 IP00 [footnote 2]
JNVX/JNFX48-210 3F480-220.230 490x170x158 13.5 IP00 [footnote 2]
JNVX/JNFX48-250 3F480-250.230 490x230x158 18.2 IP00 [footnote 2]
JNVX/JNFX48-300 3F480300.230 490x230x158 18.2 IP00 [footnote 2]
JNVX/JNFX48-375 3F480-400.230 580x230x158 22 IP00 [footnote 2]
JNVX/JNFX48-430 3F480-500.230 630x345x158 37.5 IP00 [footnote 2]
JNVX/JNFX48-500 3F480-500.230 630x345x158 37.5 IP00 [footnote 2]
JNVX/JNFX48-600 3F480-600.230 660x375x187 42 IP00 [footnote 2]
JNVX/JNFX48-650 3F480-700.230 865x345x157 42 IP00 [footnote 2]

Catalogue — Output chokes and overshoot clamp — page 24

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 24

Output choke (dU/dt) Output chokes (supplied separately) are recommended above app. 100 m cable length for all single drives. Consult your supplier in case of paralleled drives. Due to the switching of output voltage, high capacitive peak currents will run through the parasitic capacitances between the phases and to earth. Screened cables have more parasitic capacitances. Output chokes should be installed as close as possible to the drive output. Output chokes also limits voltage peaks at motor winding. Rated voltage = 800 V, IP00 units. Suitable for up to IP23 cabinet installation. Max. 40°C ambient temperature. Parallel connection of output coils possible if higher current rating required (e.g. one filter per PEBB). For further advice when to use output options see filter selection guide, page 24

Overshoot clamp Together with the output choke, the overshoot clamp restricts the voltage and the dV/dt on the motor winding. For rated voltages 380 - 690 V. H x W x D = 250 x 145 x 95 mm Part no. 052163 (size B–F) 052220 (size G–K) NOTE: AC drive, frame sizes B up to F(69), must be ordered including the option DC+/DC--connections.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Brake chopper cannot be after-mounted and brake resistor is external. Overshoot clamp needs DC+/DC− connection; B to F(69) order condition retained. Do not present as universal retrofit availability.

Context: Brake text refers to page 23, but resistors are printed 25 / PDF 26. Choke/sine text refers to filter guide page 24, but the guide is printed 26 / PDF 27. Preserve original references and provide actual provenance.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. Output choke nominal 800 V, IP00 unit, suitable up to IP23 cabinet installation, maximum40 C. Consult supplier for parallel drives.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source output choke 800 V/IP00/up to IP23 cabinet/40°C and parallel-drive referral, combined with extraction rules.

Output chokes and overshoot clamp / table 1 — PDF page 24

Nominal current IN A/phase Inductance L mH Weight kg Dimensions HxWxD mm Part number
2.8 1.5 0.6 60x78x95 473160 00
4.4 1 0.6 60x78x95 473161 00
6.6 0.65 0.6 60x78x95 473162 00
11 0.4 1 65x96x105 473163 00
14.3 0.3 1 65x96x105 473164 00
18.2 0.25 1.2 74x96x105 473165 00
26.4 0.175 1.2 74x96x105 473166 00
32 0.15 1.7 84x125x140 473167 00
65 0.1 4 105x155x205 473168 00
90 0.1 8.4 120x90x235 473169 00
146 0.05 10.2 140x190x260 473170 00
175 0.05 13.4 160x210x180 473171 00
275 0.032 18.4 170x230x200 473172 00
320 0.025 18.9 170x230x200 473173 00
410 0.021 22.6 180x240x210 473174 00

Catalogue — Sine-wave and common-mode filters — page 25

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 25

Sine wave filter Only for use with F33 drives. Rated voltage= 400 V ±25 %, 50/60 Hz (690 V on request). Max. 40 °C ambient temperature. IP20= with enclosure and screw terminals. IP00=no enclosure and busbar connections. Voltage drop approximately 25 V at rated current, 50 Hz. Overload: 110 % for 5 min, 150 % for 2 min or 200 % for 30 s. For further information see filter selection guide, page 24

Common mode filter Common mode filters are mainly used to reduce common mode currents in motors (typically used with motors >size 280). Common mode filters can prevent damage of motor bearings. All three motor phases are to be routed through common mode filter rings. These filter can also be used to reduce EMC emissions in supply cables. Part no. 052213 (size G - K69 require one Common mode filter per PEBB).

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Brake text refers to page 23, but resistors are printed 25 / PDF 26. Choke/sine text refers to filter guide page 24, but the guide is printed 26 / PDF 27. Preserve original references and provide actual provenance.

Context: Sine-wave filters are expressly for F33 only, even though the brochure is shared with V33. Retain 400 V ±25%, 50/60 Hz, 690 V on request, 40 C maximum, overload conditions and voltage-drop statement.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. Sine-wave filters FOR F33 ONLY: 400 V ±25%,50/60 Hz;690 V on request;max40 C;110%5min/150%2min/200%30s. IP20 enclosure/screw terminals versus IP00 no enclosure/busbar.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source sine-wave filter is F33-only: 400 V ±25%, 50/60 Hz, 690 V on request, 40°C and three overload durations; enclosure distinctions retained. No extension to V33 or common-mode filter inferred.

Sine-wave and common-mode filters / table 1 — PDF page 25

Filter type suffix (prefix 3AFS400-) Protection class Power kW Nominal current IN A/phase Power loss W Weight kg Dimensions HxWxD mm
002.5 IP20 0.75 2.5 75 5 190x165x160
004 IP20 1.5 4 90 5 190x165x160
007 IP20 2.2 7 125 7 250x162x162
010 IP20 4 10 165 9 250x162x162
013 IP20 5.5 13 190 12 250x162x162
016 IP20 7.5 16 220 13 300x210x180
025 IP20 11 25 250 18 300x250x210
035 IP20 15 35 275 25 300x270x235
010 IP00 4 10 165 9 195x200x115
013 IP00 5.5 13 190 12 225x200x115
016 IP00 7.5 16 220 13 225x240x135
025 IP00 11 25 250 18 270x250x160
035 IP00 15 35 275 25 270x250x160
050 IP00 22 50 320 45 280x300x250
063 IP00 30 63 550 49 270x300x370
080 IP00 37 80 380 65 324x360x320
100 IP00 45 100 530 65 324x360x320
125 IP00 55 125 650 85 335x390x320
150 IP00 75 150 580 119 440x480x340
180 IP00 90 180 760 131 440x480x340
250 IP00 132 250 600 135 420x420x390
300 IP00 160 300 1000 140 420x420x390
400 IP00 200 400 1100 320 440x500x400
500 IP00 250 500 1250 335 470x500x400

Catalogue — Brake resistors and liquid cooling — page 26

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 26

Brake resistors

VPR= Compact – IP54 with 0.75 m shielded cable.

BEGT= Steel grid resistor – IP20 or IP23 with thermo contact.

For dynamic braking by connection to the drive brake chopper output (optional).

__R: resistance in ohm, example 26R=26 ohm R: resistance in ohm, example 6R5=6.5 ohm

Drive modules in frame sizes E - K and F69 – K69 are available in a liquid cooled versions. These units are designed for connection to a liquid cooling system, normally a heat exchanger of liquid – liquid or liquid - air type. Heat exchanger is not part of the liquid cooling option. Drive units with parallel power modules (frame size G – K69) are delivered with a dividing unit for connection of the cooling system. The drive units are equipped with rubber hoses with leak-proof quick couplings.

Liquid cooling

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Overview says above 90 A; detailed option includes E–K/F69–K69. Preserve both without resolving boundary eligibility for a 90 A model. Heat exchanger explicitly excluded; parallel-module dividing unit retained.

Context: Brake text refers to page 23, but resistors are printed 25 / PDF 26. Choke/sine text refers to filter guide page 24, but the guide is printed 26 / PDF 27. Preserve original references and provide actual provenance.

Context: The first five VPR/DEGT rows do not supply 60% duty power values. Empty cells remain empty, never zero or interpolated. Dash in second dimensions column remains distinct.

Context: Single BEGT 47#120-R IP23 cell prints 301x483x736 versus IP20 1321x483x736 and the 2x version 2x(1481x483x736). Exact printed value retained; no inferred repair.

Context: Source # = 2 IP20 / # = 4 IP23 and __R/R ohmic placeholders with examples retained. Do not generate unprinted orderable resistance variants.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. First five VPR/DEGT rows use IP54 dimensions; following BEGT rows use IP20/IP23 columns. Duty columns are percentages, resistance placeholders require ohmic value; do not infer blank60% powers.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source first five VPR/DEGT IP54 rows versus BEGT IP20/IP23 dimensions with reviewer blank-duty/placeholder rules; no power inferred from blank 60% cells.

Brake resistors and liquid cooling / table 1 — PDF page 26

Type Power kW at 100% duty Power kW at 60% duty Power kW at 40% duty Power kW at 25% duty Power kW at 6% duty Dimensions HxWxD mm: IP54 for VPR/DEGT, IP20 for BEGT Dimensions HxWxD mm: dash for VPR/DEGT, IP23 for BEGT
VPR 200-__R 0.2 0.47 0.74 3.6 200x60x31 –
VPR 300-__R 0.3 0.705 1.11 5.4 250x60x31 –
VPR 400-__R 0.4 0.94 1.48 7.2 301x60x31 –
VPR 500-__R 0.5 1.175 1.85 9.0 370x60x31 –
DEGT1VPR1000S_R-S 1 2.0 3.7 13.0 542x98x170 –
BEGT 13#05-__R 2.5 3.25 4.25 6.25 21.0 301x483x326 500x483x326
BEGT 13#08-__R 4.0 5.2 6.8 10.0 34.0 301x483x326 500x483x326
BEGT 13#10-_R_ 5.0 6.5 8.5 12.5 42.5 301x483x326 500x483x326
BEGT 14#15-_R_ 7.5 9.8 12.7 18.7 64.0 301x483x426 500x483x426
BEGT 15#20-_R_ 10.0 13.0 17.0 25.0 85.0 301x483x526 500x483x526
BEGT 17#30-_R_ 15.0 19.5 25.5 37.5 127.0 301x483x740 500x483x740
BEGT 25#40-_R_ 20.0 26.0 34.0 50.0 170.0 601x484x526 800x484x526
BEGT 27#60-_R_ 30.0 39.0 51.0 75.0 255.0 601x484x736 800x484x736
BEGT 37#90-_R_ 40.0 52.0 68.0 100.0 340.0 1021x484x736 1181x484x736
BEGT 47#120-_R_ 50.0 65.0 85.0 125.0 425.0 1321x483x736 301x483x736
2xBEGT 27#60-_R_ 60.0 78.0 102.0 150.0 510.0 2x(601x484x736) 2x(800x484x736)
2xBEGT 37#78-_R_ 70.0 91.0 119.0 175.0 600.0 2x(1021x484x736) 2x(1181x484x736)
2xBEGT 37#90-_R_ 80.0 104.0 136.0 200.0 680.0 2x(1021x484x736) 2x(1181x484x736)
2xBEGT 47#120-_R_ 100.0 130.0 170.0 250.0 850.0 2x(1321x483x736) 2x(1481x483x736)

Catalogue — Filter selection guide — page 27

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 27

Filter selection guide

Recommendations with the different supply voltages up to and including 480 V

X = advised solution for this setup

Recommendations with the different supply voltages from 500 V - 690 V

Remarks

Cable lengths should always be as short as possible. The table is based on correct EMC wiring with shielded cable and proper EMC installation. For powers below 7.5 kW and long motor cables please contact Teco. Voltage drop over the complete system must be less than 10% of the main supply. Sine wave filters are only for use with Teco F33 range of drives. * Conducted interference limits on unshielded motor - lines according to EN61800-3, table 16. ** No marks in a row, means that there is no need to take precautions.

Context: No printed edition/date established; retain exact source hash and P034/P037 document associations.

Context: Brake text refers to page 23, but resistors are printed 25 / PDF 26. Choke/sine text refers to filter guide page 24, but the guide is printed 26 / PDF 27. Preserve original references and provide actual provenance.

Context: Sine-wave filters are expressly for F33 only, even though the brochure is shared with V33. Retain 400 V ±25%, 50/60 Hz, 690 V on request, 40 C maximum, overload conditions and voltage-drop statement.

Context: Keep ≤480 V and 500–690 V matrices separate. X is an advised solution; qualitative blank cells are not zero effect. The ** no-precaution statement is limited to the source row/conditions. Correct EMC installation, shielded cables, short cables, total drop <10%, below 7.5 kW long-cable referral and F33-only sine restriction remain attached.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. Qualitative effect matrix; empty cells are not inferred to mean ineffective. X means advised solution; ** no marks means no precautions in the stated source situation only. Correct EMC wiring,shielded cable,proper installation,total voltage drop<10%,F33-only sine filter restriction and below7.5kW/long-cable supplier referral remain attached.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source qualitative matrix and surrounding selection remarks with reviewer empty-cell rule. X/no-mark statements belong to the recommendation matrices and stated conditions, not automatic equivalence of every blank effect cell.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. Supply up to and including480 V. X means advised solution; ** no marks means no precautions in the stated source situation only. Correct EMC wiring,shielded cable,proper installation,total voltage drop<10%,F33-only sine filter restriction and below7.5kW/long-cable supplier referral remain attached.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source ≤480 V recommendation matrix and printed installation/voltage-drop/F33-only/referral conditions with reviewer preservation rules.

Table conditions: Exact catalogue table, model/option and units as printed. Source blanks and dashes remain distinct; null marks a merged-cell placeholder, with separate source parent-cell context. Catalogue selection data is not a substitute for verified installation instructions. Supply500–690 V. X means advised solution; ** no marks means no precautions in the stated source situation only. Correct EMC wiring,shielded cable,proper installation,total voltage drop<10%,F33-only sine filter restriction and below7.5kW/long-cable supplier referral remain attached.

Scope clarification: Reviewer-authored table context; not a literal supplier quotation. Source 500–690 V recommendation matrix and printed installation/voltage-drop/F33-only/referral conditions with reviewer preservation rules.

Filter selection guide / table 1 — PDF page 27

Phenomenon Common-mode filter Output choke Output choke and overshoot clamp Sine-wave filter All-pole sine-wave filter
Common mode currents Effective Limited effect Limited effect Effective Very effective
Bearing currents Effective Very effective
Voltage spikes U-V-W Limited effect Very effective Very effective Very effective
Voltage spikes U-PE Limited effect Effective Limited effect Very effective
dU/dt Effective Effective Very effective Very effective
Minimize motor audible noise Limited effect Limited effect Effective Effective
EMC conducted emission Limited effective Limited effect Limited effect Effective Very effective

Filter selection guide / table 2 — PDF page 27

Situation Cable-length qualification Common-mode filter Output choke Output choke and overshoot clamp Sine-wave filter All-pole sine-wave filter
Not rated, delicate or difficult positioned motors None X X
Motor in frame size >280 None X
IEC 60034-17 motor None X
IEC 60034-25 Curve A motor Cable lengths 0-100m**
None Cable lengths 100-200m X
None Cable lengths 200-500m X
Dynamic use with frequently raised DC voltage (braking) None X
Unshielded cables * None X

Filter selection guide / table 3 — PDF page 27

Situation Cable-length qualification Common-mode filter Output choke Output choke and overshoot clamp Sine-wave filter All-pole sine-wave filter
Not rated, delicate or difficult positioned motors None X X
Motor in frame size >280 None X
3 kV isolation windings ** None
IEC 60034-25 Curve B motor Cable lengths 0-100m**
None Cable lengths 100-200m X
None Cable lengths 200-500m X
Dynamic use with frequently raised DC voltage (braking) None X
Unshielded cables * None X

Catalogue — TECO back cover — page 28

TECO-F33-V33-CATALOGUE.pdf · P034, P037 · source page 28

TECO;www.teco.com.au.

Context: Website source reference only; no contact freshness or edition inferred.

Manual — TECO V33 AC drive — page 1

Manual reference: physical PDF page 1. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

TECO

V33

AC drive

Instruction manual

English

Software version 4.3X

Cover illustration is not a source of numerical product ratings.

Manual — V33 edition and document frontmatter — page 2

Manual reference: physical PDF page 2. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

V33 INSTRUCTION MANUAL - ENGLISH Software version 4.3X Document number: Edition: r3 Date of release: 30-01-2011 © Copyright the manufacturer of V33 2005 - 2011 The manufacturer retains the right to change specifications and illustrations in the text, without prior notification. The contents of this document may not be copied without the explicit permission of the manufacturer.

Manual — Blank page — page 3

Manual reference: physical PDF page 3. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually blank page.

Manual — Safety, earthing, RCD and mains ranges — page 4

Manual reference: physical PDF page 4. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Safety Instructions Instruction manual Read this instruction manual before using the AC drive (Frequency converter). The following symbols can appear in this manual. Always read these first before continuing: NOTE: Additional information as an aid to avoid problems. CAUTION! Failure to follow these instructions can result ! in malfunction or damage to the AC drive. WARNING! Failure to follow these instructions can result in serious injury to the user in addition to serious damage to the AC drive. HOT SURFACE! Failure to follow these instructions can result in injury to the user. Handling the AC drive Installation, commissioning, demounting, taking measurements, etc, of or on the AC drive may only be carried out by personnel technically qualified for the task. The installation must be carried out in accordance with local standards. Opening the AC drive WARNING! Always switch off the mains voltage before opening the AC drive and wait at least 7minutes to allow the buffer capacitors to discharge. Always take adequate precautions before opening the AC drive. Although the connections for the control sig- nals and the switches are isolated from the main volt- age, do not touch the control board when the AC drive is switched on. Precautions to be taken with a connected motor If work must be carried out on a connected motor or on the driven machine, the mains voltage must always be disconnected from the AC drive first. Wait at least 7 minutes before starting work.

Earthing The AC drive must always be earthed via the mains safety earth connection. Earth leakage current CAUTION! This AC drive has an earth leakage current ! which does exceed 3.5 mA AC. Therefore the minimum size of the protective earth conductor must comply with the local safety regulations for high leakage current equipment which means that according the standard IEC61800-5-1 the protective earth connection must be assured by one of following conditions: 1. Use a protective conductor with a cable cross- section of at least 10 mm2 for copper (Cu) or 16 mm2 for aluminium (Al). 2. Use an additional PE wire, with the same cable cross-section as the used original PE and mains supply wiring. Residual current device (RCD) compatibility This product cause a DC current in the protective conductor. Where a residual current device (RCD) is used for protection in case of direct or indirect contact, only a Type B RCD is allowed on the supply side of this product. Use RCD of 300 mA minimum. EMC Regulations In order to comply with the EMC Directive, it is abso- lutely necessary to follow the installation instructions. All installation descriptions in this manual follow the EMC Directive. Mains voltage selection The AC drive may be ordered for use with the mains voltage range listed below. JNVX48: 230-480 V JNVX52: 440-525 V JNVX69: 500-690 V Voltage tests (Megger) Do not carry out voltage tests (Megger) on the motor, before all the motor cables have been disconnected from the AC drive.

Manual — Condensation, restart and residual voltage — page 5

Manual reference: physical PDF page 5. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Condensation If the AC drive is moved from a cold (storage) room to a room where it will be installed, condensation can occur. This can result in sensitive components becoming damp. Do not connect the mains voltage until all visible dampness has evaporated. Incorrect connection The AC drive is not protected against incorrect connec- tion of the mains voltage, and in particular against con- nection of the mains voltage to the motor outlets U, V and W. The AC drive can be damaged in this way. Power factor capacitors for improving cosϕ Remove all capacitors from the motor and the motor outlet. Precautions during Autoreset When the automatic reset is active, the motor will restart automatically provided that the cause of the trip has been removed. If necessary take the appropriate precautions. Transport To avoid damage, keep the AC drive in its original packaging during transport. This packaging is specially designed to absorb shocks during transport. IT Mains supply The AC drives can be modified for an IT mains supply, (non-earthed neutral), please contact your supplier for details. Heat warning HOT SURFACE! Be aware of specific parts on the AC drive having high temperature. DC-link residual voltage WARNING! After switching off the mains supply, dangerous voltage can still be present in the AC drive. When opening the AC drive for installing and/or commissioning activities wait at least 7 minutes. In case of malfunction a qualified technician should check the DC-link or wait for one hour before dismantling the AC drive for repair.

Manual — Contents part1 — page 6

Manual reference: physical PDF page 6. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Contents Safety Instructions ......................................... 1 Contents.......................................................... 3 1. Introduction..................................................... 5 1.1 Delivery and unpacking ............................................ 5 1.2 Using of the instruction manual............................... 5 1.3 Type code number..................................................... 5 1.4 Standards .................................................................. 6 1.4.1 Product standard for EMC ........................................ 6 1.5 Dismantling and scrapping....................................... 7 1.5.1 Disposal of old electrical and electronic equipment .. 7 1.6 Glossary ..................................................................... 8 1.6.1 Abbreviations and symbols....................................... 8 1.6.2 Definitions.................................................................. 8 2. Mounting......................................................... 9 2.1 Lifting instructions..................................................... 9 2.2 Stand-alone units.................................................... 10 2.2.1 Cooling ..................................................................... 10 2.2.2 Mounting schemes.................................................. 10 2.3 Cabinet mounting.................................................... 13 2.3.1 Cooling ..................................................................... 13 2.3.2 Recommended free space in front of cabinet ...... 13 2.3.3 Mounting schemes.................................................. 14 3. Installation................................................... 15 3.1 Before installation................................................... 15 3.2 Cable connections for model 0003 to 0074 ........ 15 3.2.1 Mains cables ........................................................... 15 3.2.2 Motor cables............................................................ 16 3.3 Connection of motor and mains cables for model 0090 and up............................................................ 18 3.3.1 Connection of mains and motor cables on IP20 mod- ules........................................................................... 19 3.4 Cable specifications................................................ 20 3.5 Stripping lengths ..................................................... 20 3.5.1 Dimension of cables and fuses.............................. 21 3.5.2 Tightening torque for mains and motor cables..... 21 3.6 Thermal protection on the motor........................... 21 3.7 Motors in parallel .................................................... 21 4. Control Connections.................................... 23 4.1 Control board........................................................... 23 4.2 Terminal connections ............................................. 24 4.3 Inputs configuration with the switches..................................................... 24 4.4 Connection example ............................................... 25 4.5 Connecting the Control Signals.............................. 26 4.5.1 Cables ...................................................................... 26 4.5.2 Types of control signals .......................................... 27 4.5.3 Screening................................................................. 27 4.5.4 Single-ended or double-ended connection? ......... 27 4.5.5 Current signals ((0)4-20 mA).................................. 28 4.5.6 Twisted cables......................................................... 28

4.6 Connecting options ................................................. 28 5. Getting Started............................................. 29 5.1 Connect the mains and motor cables ................... 29 5.1.1 Mains cables ........................................................... 29 5.1.2 Motor cables............................................................ 29 5.2 Using the function keys .......................................... 29 5.3 Remote control........................................................ 30 5.3.1 Connect control cables........................................... 30 5.3.2 Switch on the mains ............................................... 30 5.3.3 Set the Motor Data.................................................. 30 5.3.4 Run the AC drive...................................................... 30 5.4 Local control............................................................ 31 5.4.1 Switch on the mains ............................................... 31 5.4.2 Select manual control............................................. 31 5.4.3 Set the Motor Data.................................................. 31 5.4.4 Enter a Reference Value......................................... 31 5.4.5 Run the AC drive...................................................... 31 6. Applications.................................................. 33 6.1 Application overview ............................................... 33 6.1.1 Cranes...................................................................... 33 6.1.2 Crushers................................................................... 33 7. Main Features .............................................. 35 7.1 Parameter sets........................................................ 35 7.1.1 One motor and one parameter set ........................ 36 7.1.2 One motor and two parameter sets....................... 36 7.1.3 Two motors and two parameter sets..................... 36 7.1.4 Autoreset at trip ...................................................... 36 7.1.5 Reference priority.................................................... 36 7.1.6 Preset references.................................................... 37 7.2 Remote control functions....................................... 37 7.3 Performing an Identification Run........................... 40 7.4 Using the Control Panel Memory............................ 40 7.5 Load Monitor and Process Protection [400]......... 41 7.5.1 Load Monitor [410]................................................. 41 8. EMC and Machine Directive........................ 43 8.1 EMC standards........................................................ 43 8.2 Stop categories and emergency stop .................... 43 9. Operation via the Control Panel.................. 45 9.1 General .................................................................... 45 9.2 The control panel .................................................... 45 9.2.1 The display............................................................... 45 9.2.2 Indications on the display....................................... 46 9.2.3 LED indicators ......................................................... 46 9.2.4 Control keys............................................................. 47 9.2.5 The Toggle and Loc/Rem Key ................................ 47 9.2.6 Function keys .......................................................... 48 9.3 The menu structure ................................................ 48 9.3.1 The main menu ....................................................... 49 9.4 Programming during operation .............................. 49 9.5 Editing values in a menu ........................................ 49

Manual — Contents part2 — page 7

Manual reference: physical PDF page 7. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

9.6 Copy current parameter to all sets ........................ 50 9.7 Programming example............................................ 50 10. Serial communication ................................. 51 10.1 Modbus RTU ............................................................ 51 10.2 Parameter sets........................................................ 51 10.3 Motor data............................................................... 52 10.4 Start and stop commands...................................... 52 10.5 Reference signal ..................................................... 52 10.5.1 Process value .......................................................... 52 10.6 Description of the EInt formats.............................. 53 11. Functional Description................................ 55 11.1 Preferred View [100]............................................... 55 11.1.1 1st Line [110].......................................................... 55 11.1.2 2nd Line [120] ........................................................ 56 11.2 Main Setup [200].................................................... 56 11.2.1 Operation [210]....................................................... 56 11.2.2 Remote Signal Level/Edge [21A]........................... 60 11.2.3 Mains supply voltage [21B].................................... 61 11.2.4 Motor Data [220] .................................................... 61 11.2.5 Motor Protection [230]........................................... 65 11.2.6 Parameter Set Handling [240]............................... 68 11.2.7 Trip Autoreset/Trip Conditions [250]..................... 71 11.2.8 Serial Communication [260].................................. 78 11.3 Process and Application Parameters [300] .......... 81 11.3.1 Set/View Reference Value [310] ........................... 81 11.3.2 Process Settings [320] ........................................... 82 11.3.3 Start/Stop settings [330] ....................................... 86 11.3.4 Mechanical brake control....................................... 90 11.3.5 Speed [340]............................................................. 93 11.3.6 Torques [350].......................................................... 96 11.3.7 Preset References [360] ........................................ 98 11.3.8 PI Speed Control [370] ........................................... 99 11.3.9 PID Process Control [380].................................... 100 11.3.10 Pump/Fan Control [390] ...................................... 104 11.3.11 Crane Option [3A0] ............................................... 110 11.4 Load Monitor and Process Protection [400]....... 113 11.4.1 Load Monitor [410]............................................... 113 11.4.2 Process Protection [420]...................................... 118 11.5 I/Os and Virtual Connections [500]..................... 119 11.5.1 Analogue Inputs [510].......................................... 119 11.5.2 Digital Inputs [520]............................................... 126 11.5.3 Analogue Outputs [530] ....................................... 128 11.5.4 Digital Outputs [540] ............................................ 132 11.5.5 Relays [550] .......................................................... 134 11.5.6 Virtual Connections [560]..................................... 135 11.6 Logical Functions and Timers [600] .................... 136 11.6.1 Comparators [610] ............................................... 136 11.6.2 Logic Output Y [620]............................................. 147 11.6.3 Logic Output Z [630]............................................. 149 11.6.4 Timer1 [640] ......................................................... 150 11.6.5 Timer2 [650] ......................................................... 152 11.7 View Operation/Status [700] ............................... 153 11.7.1 Operation [710]..................................................... 153 11.7.2 Status [720] .......................................................... 156 11.7.3 Stored values [730] .............................................. 159

11.8 View Trip Log [800] ............................................... 160 11.8.1 Trip Message log [810]......................................... 160 11.8.2 Trip Messages [820] - [890] ................................ 161 11.8.3 Reset Trip Log [8A0] ............................................. 162 11.9 System Data [900]................................................ 162 11.9.1 VSD Data [920] ..................................................... 162 12. Troubleshooting, Diagnoses and Mainte- nance 165 12.1 Trips, warnings and limits..................................... 165 12.2 Trip conditions, causes and remedial action ...... 166 12.2.1 Technically qualified personnel............................ 166 12.2.2 Opening the AC drive ............................................ 166 12.2.3 Precautions to take with a connected motor...... 166 12.2.4 Autoreset Trip........................................................ 166 12.3 Maintenance ......................................................... 170 13. Options........................................................ 171 13.1 Options for the control panel................................ 171 13.2 Handheld Control Panel 2.0 .................................................. 171 13.3 EmoSoftCom.......................................................... 171 13.4 Brake chopper....................................................... 172 13.5 I/O Board ............................................................... 173 13.6 Encoder.................................................................. 173 13.7 PTC/PT100............................................................ 173 13.8 Crane option board ............................................... 173 13.9 Serial communication and fieldbus..................... 174 13.10 Standby supply board option................................ 174 13.11 Safe Stop option.................................................... 175 13.12 Output chokes....................................................... 177 13.13 Liquid cooling ........................................................ 177 14. Technical Data ........................................... 179 14.1 Electrical specifications related to model ........... 179 14.2 General electrical specifications.......................... 183 14.3 Operation at higher temperatures ....................... 184 14.4 Dimensions and Weights...................................... 185 14.5 Environmental conditions..................................... 186 14.6 Fuses, cable cross-sections and glands.............. 187 14.6.1 According IEC ratings............................................ 187 14.6.2 Fuses and cable dimensions according to NEMA rat- ings......................................................................... 189 14.7 Control signals....................................................... 192 15. Menu List.................................................... 193 Index ........................................................... 201

Manual — Introduction and type code — page 8

Manual reference: physical PDF page 8. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Introduction The AC drive V33 is intended for controlling the speed and torque of standard three phase asynchronous elec- trical motors. The AC drive (Frequency converter) is equipped with direct torque control which uses built-in digital signal processor - DSP, giving the AC drive the capability of high dynamic performance even at very low speeds without using feedback signals from the motor. Therefore the inverter is designed for use in high dynamic applications where low speed high torque and high-speed accuracy are demanded. In “simpler” appli- cation such as fans or pumps, the V33 direct torque control offers other great advantages such as insensi- tivity to mains disturbances or load shocks. NOTE: Read this instruction manual carefully before starting installation, connection or working with the AC drive. Users This instruction manual is intended for: • installation engineers • maintenance engineers • operators • service engineers Motors The AC drive is suitable for use with standard 3-phase asynchronous motors. Under certain conditions it is possible to use other types of motors. Contact your sup- plier for details. 1.1 Delivery and unpacking Check for any visible signs of damage. Inform your sup- plier immediately of any damage found. Do not install the AC drive if damage is found. The AC drives are delivered with a template for position- ing the fixing holes on a flat surface. Check that all items are present and that the type number is correct. 1.2 Using of the instruction manual Within this instruction manual the abbreviation “AC drive” is used to indicate the complete variable speed drive as a single unit. Check that the software version number on the first page of this manual matches the software version in the AC drive. See chapter 11.9 page 166

With help of the index and the table of contents it is easy to track individual functions and to find out how to use and set them. The Quick Setup Card can be put in a cabinet door, so that it is always easy to access in case of an emer- gency. 1.3 Type code number Fig. 1 gives an example of the type code numbering used on all AC drives. With this code number the exact type of the drive can be determined. This identification will be required for type specific information when mounting and installing. The code number is located on the product label, on the front of the unit. JNVX48-0175-0054 C E – – – A – N N N N A N – Position number: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Fig. 1 Type code number

Type code positions 1 to 10 — PDF page 8

Source row Position 0003–0074 Position 0090–1500 Configuration Value
1 1 1 AC drive type F33 V33
2 2 2 Supply voltage 48=400 V mains 52=525 V mains 69=690 V mains
3 3 3 Rated current (A) continuous -003=2.5 A - -1K5=1500 A
4 4 4 Protection class 20=IP20 54=IP54
5 5 5 Control panel –=Blank panel C=Standard panel
6 6 6 EMC option E=Standard EMC (Category C3) F=Extended EMC (Category C2) I=IT-Net
7 7 7 Brake chopper option –=No chopper B=Chopper built in D=DC+/- interface
8 8 8 Stand-by power supply option –=No SBS S=SBS included
9 - 9 Safe stop option (Only valid for 090-1500) –=No safe stop T=Safe stop incl.
10 9 10 Brand label ⟦blank source cell⟧

Manual — Type code continuation and EMC — page 9

Manual reference: physical PDF page 9. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

1.4 Standards The AC drives described in this instruction manual com- ply with the standards listed in Table 1. For the declara- tions of conformity and manufacturer’s certificate, contact your supplier for more information. 1.4.1Product standard for EMC Product standard EN(IEC)61800-3, second edition of 2004 defines the: First Environment (Extended EMC) as environment that includes domestic premises. It also includes establish- ments directly connected without intermediate trans- formers to a low voltage power supply network that supplies buildings used for domestic purposes. Category C2: Power Drive System (PDS) of rated voltage<1.000 V, which is neither a plug in device nor a movable device and, when used in the first environ- ment, is intended to be installed and commissioned only by a professional. Second environment (Standard EMC) includes all other establishments. Category C3: PDS of rated voltage <1.000 V, intended for use in the second environment and not intended for use in the first environment. Category C4: PDS or rated voltage equal or above 1.000 V, or rated current equal to or above 400 A, or intended for use in complex systems in the second envi- ronment. The AC drive complies with the product standard EN(IEC) 61800-3:2004 (Any kind of metal screened cable may be used). The standard AC drive is designed to meet the requirements according to category C3. By using the optional “Extended EMC” filter the AC drive fulfils requirements according to category C2, WARNING! In a domestic environment this product may cause radio interference, in which case it may be necessary to take adequate additional measures. WARNING! The standard AC drive, complying with category C3, is not intended to be used on a low-voltage public network which supplies domestic premises; radio interference is expected if used in such a network. Contact your supplier if you need additional measures.

Type code continuation — PDF page 9

Source row Position 0003–0074 Position 0090–1500 Configuration Value
1 10 - Painted AC drive (Only valid for 003-074) A=Standard paint B=White paint RAL9010
2 11 11 Coated boards, option - =Standard boards V=Coated boards
3 12 12 Option position 1 N=No option C=Crane I/O E=Encoder P=PTC/PT100 I=Extended I/O S=Safe Stop (only 003-074)
4 13 13 Option position 2 N=No option C=Crane I/O E=Encoder P=PTC/PT100 I=Extended I/O S=Safe Stop (only 003-074)
5 14 14 Option position 3 N=No option C=Crane I/O E=Encoder P=PTC/PT100 I=Extended I/O S=Safe Stop (only 003-074)
6 15 15 Option position, communication N=No option D=DeviceNet P=Profibus S=RS232/485 M=Modbus/TCP
7 16 16 Software type A=Standard
8 17 - Motor PTC. (Only valid for 003-074) N=No option P=PTC
9 18 - Gland kit. (Only valid for 003-074) –=Glands not included G=Gland kit included

Manual — Standards and disposal — page 10

Manual reference: physical PDF page 10. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 1 Standards 1.5 Dismantling and scrapping The enclosures of the drives are made from recyclable material as aluminium, iron and plastic. Each drive con- tains a number of components demanding special treatment, for example electrolytic capacitors. The cir- cuit boards contain small amounts of tin and lead. Any local or national regulations in force for the disposal and recycling of these materials must be complied with.

1.5.1Disposal of old electrical and electronic equipment This information is applicable in the European Union and other European countries with separate collection systems. This symbol on the product or on its packaging indi- cates that this product shall be taken to the applicable collection point for the recycling of electrical and elec- tronic equipment. By ensuring this product is disposed of cor- rectly, you will help prevent potentially negative conse- quences for the environment and human health, which could otherwise be caused by inappropriate waste han- dling of this product. The recycling of materials will help to conserve natural resources. For more detailed infor- mation about recycling this product, please contact the local distributor of the product.

Table1 Standards — PDF page 10

Source row Market Standard Description
1 European EMC Directive 2004/108/EEC
2 European Low Voltage Directive 2006/95/EC
3 European WEEE Directive 2002/96/EC
4 All EN 60204-1 Safety of machinery - Electrical equipment of machines Part 1: General requirements.
5 All EN(IEC)61800-3:2004 Adjustable speed electrical power drive systems Part 3: EMC requirements and specific test methods. EMC Directive: Declaration of Conformity and CE marking
6 All EN(IEC)61800-5-1 Ed. 2.0 Adjustable speed electrical power drive systems Part 5-1. Safety requirements - Electrical, thermal and energy. Low Voltage Directive: Declaration of Conformity and CE marking
7 All IEC 60721-3-3 Classification of environmental conditions. Air quality chemical vapours, unit in operation. Chemical gases 3C2, Solid particles 3S2. Optional with coated boards Unit in operation. Chemical gases Class 3C3, Solid particles 3S2.
8 All UL508C UL Safety standard for Power Conversion Equipment
9 USA ≥90 A only UL 840 UL Safety standard for Power Conversion Equipment power conversion equipment. Insulation coordination including clearances and creepage distances for electrical equipment.
10 Russian GOST R For all sizes

Manual — Glossary and definitions — page 11

Manual reference: physical PDF page 11. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

1.6 Glossary 1.6.1Abbreviations and symbols In this manual the following abbreviations are used: Table 2 Abbreviations

1.6.2Definitions In this manual the following definitions for current, torque and frequency are used: Table 3 Definitions

Table3 Definitions — PDF page 11

Source row Name Description Quantity
1 IIN Nominal input current of AC drive ARMS
2 INOM Nominal output current of AC drive ARMS
3 IMOT Nominal motor current ARMS
4 PNOM Nominal power of AC drive kW
5 PMOT Motor power kW
6 TNOM Nominal torque of motor Nm
7 TMOT Motor torque Nm
8 fOUT Output frequency of AC drive Hz
9 fMOT Nominal frequency of motor Hz
10 nMOT Nominal speed of motor rpm
11 ICL Maximum output current ARMS
12 Speed Actual motor speed rpm
13 Torque Actual motor torque Nm
14 Sync speed Synchronous speed of the motor rpm

Table2 Abbreviations — PDF page 11

Source row Abbreviation or symbol Description
1 DSP Digital signals processor
2 AC drive Frequency converter
3 PEBB Power Electronic Building Block
4 IGBT Insulated Gate Bipolar Transistor
5 CP Control panel, the programming and presen- tation unit on the AC drive
6 EInt Communication format
7 UInt Communication format (Unsigned integer)
8 Int Communication format (Integer)
9 Long Communication format
10 [padlock symbol] The function cannot be changed in run mode

Manual — Mounting and lifting — page 12

Manual reference: physical PDF page 12. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Source limitation for this page: Figure2 final g in Load56to74kg partly clipped; no unseen continuation inferred.

  1. Mounting This chapter describes how to mount the AC drive. Before mounting it is recommended that the installa- tion is planned out first. • Be sure that the AC drive suits the mounting loca- tion. • The mounting site must support the weight of the AC drive. • Will the AC drive continuously withstand vibrations and/or shocks? • Consider using a vibration damper. • Check ambient conditions, ratings, required cooling air flow, compatibility of the motor, etc. • Know how the AC drive will be lifted and trans- ported. 2.1 Lifting instructions Note: To prevent personal risks and any damage to the unit during lifting, it is advised that the lifting methods described below are used. Recommended for AC drive models -0090 to -0250 Fig. 2 Lifting AC drive model -0090 to -0250

Recommended for AC drive models -0300 to -1500 Fig. 3 Remove the roof unit and use the lifting eyes to lift single unit 600mm and 900mm. Single cabinet drives can be lifted/transported safely using the eyebolts supplied and lifting cables/chains as in illustration Fig. 3 above. Depending on the cable/chain angle A (in Fig. 3), following loads are permitted: Regarding lifting instructions for other cabinet sizes, please contact your supplier.

Visible load annotation: Load: 56 to 74 kg (final g partly clipped by source frame). Model0090 to0250. Lifting geometry remains in original figure.

Lifting eyes; A°. Roof removal and single600mm/900mm units are specified in caption/prose. Original lifting geometry retained.

Permitted lifting load — PDF page 12

Source row Cable/chain angle A Permitted load
1 45 ° 4 800 N
2 60 ° 6 400 N
3 90 ° 13 600N

Manual — Cooling clearances and B frame — page 13

Manual reference: physical PDF page 13. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

2.2 Stand-alone units The AC drive must be mounted in a vertical position against a flat surface. Use the template (delivered together with the AC drive) to mark out the position of the fixing holes. Fig. 4 AC drive mounting model 0003 to 1500 2.2.1 Cooling Fig. 4 shows the minimum free space required around the AC drive for the models 0003 to 1500 in order to guarantee adequate cooling. Because the fans blow the air from the bottom to the top it is advisable not to position an air inlet immediately above an air outlet. The following minimum separation between two AC drives, or a AC drive and a non-dissipating wall must be maintained. Valid if free space on opposite side. Table 4 Mounting and cooling NOTE: When a 0300 to 1500 model is placed between two walls, a minimum distance at each side of 200 mm must be maintained.

2.2.2 Mounting schemes Fig. 5 JNVX48/52: Model 0003 to 0018 (B) Fig. 6 Cable interface for mains, motor and communica- tion,JNVX48/52: Model 0003 to 0018 (B) Fig. 7 JNVX48/52: Model 0003 to 0018 (B), with optional gland plate

Diagram labels a (top), b (bottom), c (left), d (right). Values are in Table4; no dimensions derived from drawing scale.

Printed dimension labels: 128.5; 37; 10; 416; 396; 202.6; Ø13 (2x); Ø7 (4x). Source figure provides arrows; no unit inferred beyond explicit source text.

Glands M20; Gland M16; Gland M25; Glands M32. Figure6 caption supplies JNVX48/52 model0003–0018 B applicability.

Optional gland plate illustrated for JNVX48/52 model0003–0018 B. No additional dimension labels.

V33-V33 side-by-side (mm), only with free space on opposite side. Diagram4 identifies a/b/c/d; two-wall exception remains separate.

V33-wall, wall-one side (mm), only with free space opposite. 0300–1500 between two walls requires 200mm each side per note.

Table4 Mounting and cooling — PDF page 13

Source row Clearance label 0003–0018 0026–0074 0090–0250 0300–1500 cabinet
1 a 200 200 200 100
2 b 200 200 200 0
3 c 0 0 0 0
4 d 0 0 0 0

Table4 Wall on one side — PDF page 13

Source row Clearance label 0003–0018 0026–0074 0090–0250 0300–1500 cabinet
1 a 100 100 100 100
2 b 100 100 100 0
3 c 0 0 0 0
4 d 0 0 0 0

Manual — C/D frame and glands — page 14

Manual reference: physical PDF page 14. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 8 JNVX48/52: Model 0026 to 0046 (C) Fig. 9 Cable interface for mains, motor and communication, JNVX48/52: Model 0026 to 0046 (C)

Fig. 10 JNVX48/52: Model 0061 to 0074 (D) Fig. 11 Cable interface for mains, motor and communication, JNVX48/52: Model 0061 to 0074 (D). NOTE: Glands for size B, C and D are available as option kit.

Printed dimension labels: 128,5; 24,8; 10; Ø13 (2x); 512; 492; Ø7 (4x); 178; 232,1. Comma decimal retained; enlarged depth label reads232,1.

Gland M25 (026–031) / M32 (037–046); Glands M32 (026–031) / M40 (037–046); Glands M20.

Printed dimension labels: 30; 160; 10; Ø13 (2x); 570; 590; Ø7 (4x); 220.

Glands M20 (both indicated groups); Glands M50; Glands M40.

Manual — E/F/F69 frame dimensions — page 15

Manual reference: physical PDF page 15. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 12 JNVX48: Model 0090 to 0175 (E) including cable interface for mains, motor and communication

Fig. 13 JNVX48: Model 0210 to 0250 (F) JNVX69: Model 0090 to 0175 (F69) including cable interface for mains, motor and communication

Cable glands M20; Cable flexible leadthrough Ø17–42 /M50; Cable flexible leadthrough Ø11–32 /M40. Printed dimensions:22.5;240;120;10;Ø9(6x);Ø16(3);284.5;275;30;925;952.5;922.5;314. Preserve source arrows, no assumed unit.

Cable glands M20; Cable flexible leadthrough Ø23–55 /M63; Cable flexible leadthrough Ø17–42 /M50. Printed dimensions:22.5;300;150;10;Ø9(x6);344.5;335;30;A;B;C;314. A/B/C mm values supplied only by adjacent frame table.

Figure13 applicable models only; A/B/C shown in original drawing. Units explicitly mm in table.

Figure13 F and F69 dimensions — PDF page 15

Source row Frame JNVX model A (mm) B (mm) C (mm)
1 F 0210 - 0250 925 950 920
2 F69 0090 - 0175 1065 1090 1060

Manual — Cabinet airflow and front clearance — page 16

Manual reference: physical PDF page 16. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

2.3 Cabinet mounting 2.3.1 Cooling If the variable speed drive is installed in a cabinet, the rate of airflow supplied by the cooling fans must be tak- en into consideration. Table 5 Flow rates cooling fans NOTE: For the models 0860 to 1500 the mentioned amount of air flow should be divided equally over the two cabinets.

2.3.2 Recommended free space in front of cabinet All cabinet mounted AC drives are designed in modules, so called PEBBs. These PEBBs can be folded out to be replaced. To be able to remove a PEBB in the future, we recommend 1.30 meter free space in front of the cabi- net, see Fig. 14. Fig. 14 Recommended free space in front of the cabinet mounted AC drive

Printed front-clearance label1300; nearby prose explicitly recommends1.30meter. Tiny internal component markings remain raw diagram context and are not adopted as product ratings.

Shared flow cells repeated for listed frames only. Models0860–1500 split airflow equally between two cabinets; do not double total.

Table5 Cooling fan flow rates — PDF page 16

Source row Frame JNVX model Flow rate (m³/hour)
1 B 0003 - 0018 75
2 C 0026 – 0031 120
3 C 0037 - 0046 170
4 D 0061 - 0074 170
5 E 0090 - 0175 510
6 F 0210 - 0250 800
7 F69 0090 - 0175 800
8 G 0300 - 0375 1020
9 H 0430 - 0500 1600
10 H69 0210 - 0375 1600
11 I 0600 - 0750 2400
12 I69 0430 - 0500 2400
13 J 0860 - 1000 3200
14 J69 0600 - 0650 3200
15 K 1200 - 1500 4800
16 K69 0750 - 1000 4800

Manual — Cabinet dimensions G–K69 — page 17

Manual reference: physical PDF page 17. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

2.3.3 Mounting schemes Fig. 15 JNVX48: Model 0300 to 0500 (G and H) JNVX69: Model 0210 to 0375 (H69) Fig. 16 JNVX48: Model 0600 to 0750 (I) JNVX69: Model 0430 to 0500 (I69)

Fig. 17 JNVX48: Model 0860 to 1000 (J) JNVX69: Model 0600 to 0650 (J69) Fig. 18 JNVX48: Model 1200 to 1500 (K) JNVX69: Model 0750 to 1000 (K69)

JNVX48 model0300–0500 G/H; JNVX69 model0210–0375 H69. Printed labels150,2250,2000,100,600 (width),600 (depth). Drawing scale not used.

JNVX48 model0600–0750 I; JNVX69 model0430–0500 I69. Printed labels150,2250,2000,100,900 (width),600 (depth).

JNVX48 model0860–1000 J; JNVX69 model0600–0650 J69. Printed labels150,2250,2000,100,1200 (width),600 (depth).

JNVX48 model1200–1500 K; JNVX69 model0750–1000 K69. Printed labels150,2250,2000,100,1800 (width),600 (depth).

Manual — Installation and mains cables — page 18

Manual reference: physical PDF page 18. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Installation The description of installation in this chapter complies with the EMC standards and the Machine Directive. Select cable type and screening according to the EMC requirements valid for the environment where the AC drive is installed. 3.1 Before installation Read the following checklist and prepare for your application before installation. • Local or remote control. • Long motor cables (>100m), refer to section Long motor cables page 18. • Motors in parallel, refer to menu [213] page 65. • Functions used. • Suitable AC drive size in proportion to the motor/application. If the AC drive is temporarily stored before being con- nected, please check the technical data for environ- mental conditions. If the AC drive is moved from a cold storage room to the room where it is to be installed, condensation can form on it. Allow the AC drive to become fully acclimatised and wait until any visible condensation has evaporated before connecting the mains voltage. 3.2 Cable connections for model 0003 to 0074 3.2.1 Mains cables Dimension the mains and motor cables according to local regulations. The cable must be able to carry the AC drive load current. Recommendations for selecting mains cables • To fulfil EMC purposes it is not necessary to use screened mains cables. • Use heat-resistant cables, +60°C or higher. • Dimension the cables and fuses in accordance with local regulations and the nominal current of the motor. See table 49, page 191. • The litz ground connection see fig. 23, is only neces- sary if the mounting plate is painted. All the AC drives have an unpainted back side and are there- fore suitable for mounting on an unpainted mount- ing plate.

Connect the mains cables according to fig. 19 or 20. The AC drive has as standard a built-in RFI mains filter that complies with category C3 which suits the Second Environment standard. Fig. 19 Mains and motor connections, model 0003-0018 Fig. 20 Mains and motor connections, 0026-0046

Visible terminal labels L1,L2,L3; DC−,DC+,R; motor earth symbol,U,V,W. PE; Screen connection of motor cables. Diagram remains authority for physical connection geometry.

Visible terminal labels L1,L2,L3; DC−,DC+,R; U,V,W. PE; Screen connection of motor cables. No wire route inferred.

Manual — Terminal connections and motor cables — page 19

Manual reference: physical PDF page 19. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 21 Mains and motor connection, model 0061 - 0074 Table 6 Mains and motor connections NOTE: The Brake and DC-link Terminals are only fitted if the DC+/DC- option or Brake Chopper Option is built-in. WARNING! The Brake Resistor must be connected between terminals DC+ and R. WARNING! In order to work safely, the mains earth must be connected to PE and the motor earth to .

3.2.2 Motor cables To comply with the EMC emission standards the AC drive is provided with a RFI mains filter. The motor cables must also be screened and connected on both sides. In this way a so-called “Faraday cage” is created around the AC drive, motor cables and motor. The RFI currents are now fed back to their source (the IGBTs) so the system stays within the emission levels. Recommendations for selecting motor cables • Use screened cables according to specification in table 7. Use symmetrical shielded cable; three phase conductors and a concentric or otherwise symmetrically constructed PE conductor, and a shield. • When the conductivity of the cable PE conductor is <50% of the conductivity of the phase conductor, a separate PE conductor is required. • Use heat-resistant cables, +60°C or higher. • Dimension the cables and fuses in accordance with the nominal output current of the motor. See table 49, page 191. • Keep the motor cable between AC drive and motor as short as possible. • The screening must be connected with a large con- tact surface of preferable 360° and always at both ends, to the motor housing and the AC drive hous- ing. When painted mounting plates are used, do not be afraid to scrape away the paint to obtain as large contact surface as possible at all mounting points for items such as saddles and the bare cable screening. Relying just on the connection made by the screw thread is not sufficient. NOTE: It is important that the motor housing has the same earth potential as the other parts of the machine. • The litz ground connection, see fig. 23, is only nec- essary if the mounting plate is painted. All the AC drives have an unpainted back side and are there- fore suitable for mounting on an unpainted mount- ing plate. Connect the motor cables according to U - U, V - V and W - W, see Fig. 19, Fig. 20 and Fig. 21 . NOTE: The terminals DC-, DC+ and R are options.

Visible terminal labels L1,L2,L3,PE,DC−,DC+,R,motor earth,U,V,W; PE; Screen connection of motor cables. Original geometry retained.

Pairs separated by actual aligned text. Earth symbol rendered descriptively; brake/DC optional. Separate warning DC+ and R remains authoritative.

Table6 Mains and motor connections — PDF page 19

Source row Terminal Meaning
1 L1,L2,L3 Mains supply, 3 -phase
2 PE Safety earth (protected earth)
3 [motor earth symbol] Motor earth
4 U, V, W Motor output, 3-phase
5 DC-,DC+,R Brake resistor, DC-link connections (optional)

Manual — Shielding and cabinet examples — page 20

Manual reference: physical PDF page 20. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Switches between the motor and the AC drive If the motor cables are to be interrupted by mainte- nance switches, output coils, etc., it is necessary that the screening is continued by using metal housing, metal mounting plates, etc. as shown in the Fig. 23. Fig. 22 Screen connection of cables. Pay special attention to the following points: • If paint must be removed, steps must be taken to prevent subsequent corrosion. Repaint after making connections! • The fastening of the whole AC drive housing must be electrically connected with the mounting plate over an area which is as large as possible. For this pur- pose the removal of paint is necessary. An alterna- tive method is to connect the AC drive housing to the mounting plate with as short a length of litz wire as possible. • Try to avoid interruptions in the screening wherever possible. • If the AC drive is mounted in a standard cabinet, the internal wiring must comply with the EMC standard. Fig. 23 shows an example of a AC drive built into a cabinet.

Fig. 23 AC drive in a cabinet on a mounting plate Fig. 24 shows an example when there is no metal mounting plate used (e.g. if IP54 AC drives are used). It is important to keep the “circuit” closed, by using metal housing and cable glands. Fig. 24 AC drive as stand alone

Screen connection of signal cables; PE and earth symbol; Motor cable shield connection.

AC drive built into cabinet; RFI-Filter(option); Mains; Motor; Litz; Metal EMC cable glands; Output coil(option); Screened cables; Unpainted mounting plate; Metal connector housing; Metal coupling nut; Mains(L1,L2,L3,PE); Brake resistor(option). Terminal labels L1,L2,L3,PE,DC−,DC+,R,earth,U,V,W. Connector labels L1,L2,L3,PE; R R; U V W earth. Drawing reference06-F39; circuit topology remains original.

AC drive; RFI-Filter; Mains; Metal EMC cable glands; Screened cables; Metal housing; Brake resistor(option); Output coils(option); Metal connector housing; Metal cable gland; Motor. Terminal labels L1,L2,L3,PE,DC−,DC+,R,earth,U,V,W. Reference06-F41; topology remains original.

Manual — Cable placement and 0090+ connections — page 21

Manual reference: physical PDF page 21. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Connect motor cables 1. Remove the cable interface plate from the AC drive housing. 2. Put the cables through the glands. 3. Strip the cable according to Table 8. 4. Connect the stripped cables to the respective motor terminal. 5. Put the cable interface plate in place and secure with the fixing screws. 6. Tighten the EMC gland with good electrical contact to the motor and brake chopper cable screens. Placing of motor cables Keep the motor cables as far away from other cables as possible, especially from control signals. The minimum distance between motor cables and control cables is 300 mm. Avoid placing the motor cables in parallel with other cables. The power cables should cross other cables at an angle of 90°. Long motor cables If the connection to the motor is longer than 100 m (40 m for models 0003-0018), it is possible that capacitive current peaks will cause tripping at overcurrent. Using output coils can prevent this. Contact the supplier for appropriate coils. Switching in motor cables Switching in the motor connections is not advisable. In the event that it cannot be avoided (e.g. emergency or maintenance switches) only switch if the current is zero. If this is not done, the AC drive can trip as a result of current peaks.

3.3 Connection of motor and mains cables for model 0090 and up AC drive JNVX48-0090 and up, JNVX69-0090 and up To simplify the connection of thick motor and mains cables to the AC drive, the cable interface plate can be removed. Fig. 25 Connecting motor and mains cables 1. Remove the cable interface plate from the AC drive housing. 2. Put the cables through the glands. 3. Strip the cable according to Table 8. 4. Connect the stripped cables to the respective mains/motor terminal. 5. Fix the clamps on appropriate place and tighten the cable in the clamp with good electrical contact to the cable screen. 6. Put the cable interface plate in place and secure with the fixing screws.

Clamps for screening; Cable interface; Motor cable; DC+,DC−,R(optional); Mains cable. Applies to source JNVX48-0090 and up, JNVX69-0090 and up; original assembly geometry retained.

Manual — Large model and IP20 connections — page 22

Manual reference: physical PDF page 22. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

AC drive model 0048-0300 & 0069-0210 and up Fig. 26 Connect motor cables and mains cables to the terminals and earth/ground to the bus bar. AC drive models 48-0300 & 0069-0210 and up are supplied with power clamps for mains and motors, for connection of PE and earth there is a bus bar. For all type of wires to be connected the stripping length should be 32 mm.

3.3.1 Connection of mains and motor cables on IP20 modules The IP 20 modules are delivered complete with factory mounted cables for mains and motor. The length of the cables are app. 1100 mm. The cables are marked L1, L2, L3 for mains connection and U, V, W for motor con- nection. For detailed information about use of the IP20 mod- ules, please contact your supplier. Fig. 27 IP20 module size G, with qty 2 x 3 mains cables and qty 2 x 3 motor cables.

Motor connection U,V,W; Mains Connection L1,L2,L3; Ground/earth connection bus bar. Source power clamps and32mm stripping procedure retained separately. Microscopic internal labels raw only.

PEBB1(Master); PEBB2; Mains cables L1,L2,L3; Motor cables U,V,W. Caption qty2x3 mains and qty2x3motor cables.

Manual — Cable specifications and stripping — page 23

Manual reference: physical PDF page 23. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 28 IP20 module size H/H69 with qty 3 x 3 Mains cables and qty 3 x 3 motor cables.

3.4 Cable specifications Table 7 Cable specifications 3.5 Stripping lengths Fig. 29 indicates the recommended stripping lengths for motor and mains cables. Table 8 Stripping lengths for mains and motor cables Mains cable Motor cable Fig. 29 Stripping lengths for cables

PEBB1(Master); PEBB2; PEBB3; Mains cables L1,L2,L3; Motor cables U,V,W. Caption qty3x3mains and qty3x3motor cables.

Mains a,b; Motor a,b,c; source reference06-F45-cables only. Numeric stripping lengths supplied by Table8, not diagram scale.

Complete Mains/Motor/Control rows; automatic extraction merged motor and control. Literal source shielding requirements.

Table8 Stripping lengths — PDF page 23

Source row Model Mains a (mm) Mains b (mm) Motor a (mm) Motor b (mm) Motor c (mm)
1 0003-0018 90 10 90 10 20
2 0026–0046 150 14 150 14 20
3 0061–0074 110 17 110 17 34
4 0090-0175 160 16 160 16 41
5 JNVX48- 0210–0250 JNVX69-0090- 0175 170 24 170 24 46

Table7 Cable specifications — PDF page 23

Source row Cable Cable specification
1 Mains Power cable suitable for fixed installation for the voltage used.
2 Motor Symmetrical three conductor cable with concentric protection (PE) wire or a four conductor cable with compact low-impedance concentric shield for the voltage used.
3 Control Control cable with low-impedance shield, screened.

Manual — Terminal torque and motor conditions — page 24

Manual reference: physical PDF page 24. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

3.5.1 Dimension of cables and fuses Please refer to the chapter Technical data, section 14.7, page 191. 3.5.2 Tightening torque for mains and motor cables Table 9 Model JNVX48/52 0003 to 0046 Table 10 Model JNVX48/52 0061 to 0074 Table 11 Model JNVX48 0090 to 0109 Table 12 Model JNVX48 0146 to 0175 Table 13 Model JNVX48 0210 to 0250 and JNVX69 0090 to 0175

3.6 Thermal protection on the motor Standard motors are normally fitted with an internal fan. The cooling capacity of this built-in fan is depend- ent on the frequency of the motor. At low frequency, the cooling capacity will be insufficient for nominal loads. Please contact the motor supplier for the cooling char- acteristics of the motor at lower frequency. WARNING! Depending on the cooling characteristics of the motor, the application, the speed and the load, it may be necessary to use forced cooling on the motor. Motor thermistors offer better thermal protection for the motor. Depending on the type of motor thermistor fitted, the optional PTC input may be used. The motor thermistor gives a thermal protection independent of the speed of the motor, thus of the speed of the motor fan. See the functions, Motor I2t type [231] and Motor I2t current [232]. 3.7 Motors in parallel It is possible to have motors in parallel as long as the total current does not exceed the nominal value of the AC drive. The following has to be taken into account when setting the motor data: NOTE: The shafts of the motors in parallel must be physically connected to obtain correct torque and speed control.

Table9 JNVX48/52 0003–0046 — PDF page 24

Source row Quantity Brake chopper Mains/motor
1 Tightening torque, Nm 1.2-1.4 1.2-1.4

Table10 JNVX48/52 0061–0074 — PDF page 24

Source row Quantity All cables 60 A All cables 73 A
1 Tightening torque, Nm 2.8 5.0

Table11 JNVX48 0090–0109 — PDF page 24

Source row Quantity Brake chopper Mains/motor
1 Block, mm2 95 95
2 Cable diameter, mm2 16-95 16-95
3 Tightening torque, Nm 14 14

Table12 JNVX48 0146–0175 — PDF page 24

Source row Quantity Brake chopper Mains/motor column1 Mains/motor column2
1 Block, mm2 95 150 150
2 Cable diameter, mm2 16-95 35-95 120-150
3 Tightening torque, Nm 14 14 24

Motors in parallel settings — PDF page 24

Source row Menu Condition
1 Menu [221] Motor Voltage: The motors in parallel must have the same motor voltage.
2 Menu [222] Motor Frequency: The motors in parallel must have the same motor frequency.
3 Menu [223] Motor Power: Add the motor power values for the motors in parallel.
4 Menu [224] Motor Current: Add the current for the motors in parallel.
5 Menu [225] Motor Speed: Set the average speed for the motors in parallel.
6 Menu [227] Motor Cos PHI: Set the average Cos PHI value for the motors in parallel.

Table13 JNVX48 0210–0250 and JNVX69 0090–0175 — PDF page 24

Source row Quantity Brake chopper column1 Brake chopper column2 Mains/motor column1 Mains/motor column2
1 Block, mm2 150 150 240 240
2 Cable diameter, mm2 35-95 120-150 35-70 95-240
3 Tightening torque, Nm 14 24 14 24

Manual — Installation — page 25

Manual reference: physical PDF page 25. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Control board layout — page 26

Manual reference: physical PDF page 26. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Control Connections 4.1 Control board Fig. 30 shows the layout of the control board which is where the parts most important to the user are located. Although the control board is galvanically isolated from the mains, for safety reasons do not make changes while the mains supply is on! Fig. 30 Control board layout

WARNING! Always switch off the mains voltage and wait at least 7 minutes to allow the DC capacitors to discharge before connecting the control signals or changing position of any switches. If the option External supply is used, switch of the mains to the option. This is done to prevent damage on the control board.

X5 option1; X6 option2; X7 option3; X4 C Communication; X8 Control Panel. SwitchesS1,S2,S3,S4 labeled I/U, pictured at I. X1 bottom terminals:1 +10V;2 AI1;3 AI2;4 AI3;5 AI4;6 −10V;7 earth/common symbol;8 DI1;9 DI2;10 DI3;11 +24V. Upper:12 earth/common;13 AO1;14 AO2;15 earth/common;16 DI4;17 DI5;18 DI6;19 DI7;20 DO1;21 DO2;22 DI8. X2 RO1:31 NC;32 C;33 NO. RO2:41 NC;42 C;43 NO. X3 RO3:51 NO;52 C. Relay3 pin meanings conflict with PDF27 table14; preserve both and do not resolve wiring from this transcription.

Manual — Control defaults and analog switches — page 27

Manual reference: physical PDF page 27. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

4.2 Terminal connections The terminal strip for connecting the control signals is accessible after opening the front panel. The table describes the default functions for the sig- nals. The inputs and outputs are programmable for other functions as described in chapter 11. page 63. For signal specifications refer to chapter 14. page 183. NOTE: The maximum total combined current for outputs 11, 20 and 21 is 100mA. NOTE: It is possible to use external 24V if connection to Common (15). Table 14 Control signals

Table 14 Control signals NOTE: N/C is opened when the relay is active and N/O is closed when the relay is active. 4.3 Inputs configuration with the switches The switches S1 to S4 are used to set the input configu- ration for the 4 analogue inputs AnIn1, AnIn2, AnIn3 and AnIn4 as described in table 15. See Fig. 30 for the location of the switches. Table 15 Switch settings NOTE: Scaling and offset of AnIn1 - AnIn4 can be configured using the software. See menus [512], [515], [518] and [51B] in section 11.5, page 123. NOTE: the 2 analogue outputs AnOut 1 and AnOut 2 can be configured using the software. See menu [530] section 11.5.3, page 132

Default functions only; outputs/digital input/digital output/analog input/analog output categories preserved by terminal names. Max combined outputs11,20,21 is100mA; external24V needsCommon15; all source qualifications retained.

Table14 Relay outputs — PDF page 27

Source row Terminal Name Function default
1 31 N/C 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition.
2 32 COM 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition.
3 33 N/O 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition.
4 41 N/C 2 Relay 2 output Run, active when the AC drive is started.
5 42 COM 2 Relay 2 output Run, active when the AC drive is started.
6 43 N/O 2 Relay 2 output Run, active when the AC drive is started.
7 51 COM 3 Relay 3 output Off
8 52 N/O 3 Relay 3 output Off

Table15 Analog input switches — PDF page 27

Source row Input Signal type Switch picture
1 AnIn1 Voltage S1: U (voltage position)
2 AnIn1 Current (default) S1: I (current position, default)
3 AnIn2 Voltage S2: U (voltage position)
4 AnIn2 Current (default) S2: I (current position, default)
5 AnIn3 Voltage S3: U (voltage position)
6 AnIn3 Current (default) S3: I (current position, default)
7 AnIn4 Voltage S4: U (voltage position)
8 AnIn4 Current (default) S4: I (current position, default)

Table14 Control signals — PDF page 27

Source row Terminal Name Function default
1 1 +10 V +10 VDC supply voltage
2 6 -10 V -10 VDC supply voltage
3 7 Common Signal ground
4 11 +24 V +24 VDC supply voltage
5 12 Common Signal ground
6 15 Common Signal ground
7 8 DigIn 1 RunL (reverse)
8 9 DigIn 2 RunR (forward)
9 10 DigIn 3 Off
10 16 DigIn 4 Off
11 17 DigIn 5 Off
12 18 DigIn 6 Off
13 19 DigIn 7 Off
14 22 DigIn 8 RESET
15 20 DigOut 1 Ready
16 21 DigOut 2 Brake
17 2 AnIn 1 Process Ref
18 3 AnIn 2 Off
19 4 AnIn 3 Off
20 5 AnIn 4 Off
21 13 AnOut 1 Min speed to max speed
22 14 AnOut 2 0 to max torque

Manual — Connection example — page 28

Manual reference: physical PDF page 28. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

4.4 Connection example Fig. 31 gives an overall view of a AC drive connection example. Fig. 31 Connection example

Mains terminals L1,L2,L3,PE; RFI-filter; motor U,V,W,earth. Optional DC+,R,DC−. Alternative for potentiometer control terminals1–7;0–10V /4–20mA. Main control labels:1 +10VDC;2 AnIn1:Reference;3 AnIn2;4 AnIn3;5 AnIn4;6 −10VDC;7 Common;8 DigIn1:RunL;9 DigIn2:RunR;10 DigIn3;11 +24VDC;15 Common;16 DigIn4;17 DigIn5;18 DigIn6;19 DigIn7;22 DigIn8:Reset. Outputs:Common12;AnOut1 13;AnOut2 14;DigOut1 20;DigOut2 21. Relay1:31,32,33;Relay2:41,42,43;Relay3:51,52. Comm.options /Fieldbus option orPC; Other options /Option board. Default setting. The switchS1 is set toU. ReferenceNG_06-F27. Keypad photograph and schematic connection geometry are original-only; tiny hidden native21 adjacent14 not adopted.

Manual — Control signal cable connection models — page 29

Manual reference: physical PDF page 29. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

4.5 Connecting the Control Signals 4.5.1Cables The standard control signal connections are suitable for stranded flexible wire up to 1.5 mm2 and for solid wire up to 2.5 mm2. Fig. 33 Connecting the control signals, 0026 to 0046

Fig. 35 Connecting the control signals, 0090 to 0250

Figure32 models0003–0018; Figure33 models0026–0046. Both label Control signals. Internal component markings are diagram context, not additional drive ratings; installation geometry remains original.

Figure34 models0061–0074; Figure35 models0090–0250. Both label Control signals. No hidden component markings or wire route inferred.

Manual — Cable screening and wire specifications — page 30

Manual reference: physical PDF page 30. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

NOTE: The screening of control signal cables is necessary to comply with the immunity levels given in the EMC Directive (it reduces the noise level). NOTE: Control cables must be separated from motor and mains cables. 4.5.2 Types of control signals Always make a distinction between the different types of signals. Because the different types of signals can adversely affect each other, use a separate cable for each type. This is often more practical because, for example, the cable from a pressure sensor may be con- nected directly to the AC drive. We can distinguish between the following types of con- trol signals: Analogue inputs Voltage or current signals, (0-10 V, 0/4-20 mA) nor- mally used as control signals for speed, torque and PID feedback signals. Analogue outputs Voltage or current signals, (0-10 V, 0/4-20 mA) which change slowly or only occasionally in value. In general, these are control or measurement signals. Digital Voltage or current signals (0-10 V, 0-24 V, 0/4-20 mA) which can have only two values (high or low) and only o ccasionally change in value. Data Usually voltage signals (0-5 V, 0-10 V) which change rapidly and at a high frequency, generally data signals such as RS232, RS485, Profibus, etc. Relay Relay contacts (0-250 VAC) can switch highly inductive loads (auxiliary relay, lamp, valve, brake, etc.). Example: The relay output from a AC drive which controls an auxiliary relay can, at the moment of switching, form a source of interference (emission) for a measurement signal from, for example, a pressure sensor. Therefore

it is advised to separate wiring and screening to reduce disturbances. 4.5.3 Screening For all signal cables the best results are obtained if the screening is connected to both ends: the AC drive side and the at the source (e.g. PLC, or computer). See Fig. 36. It is strongly recommended that the signal cables be allowed to cross mains and motor cables at a 90° angle. Do not let the signal cable go in parallel with the mains and motor cable. 4.5.4 Single-ended or double-ended connection? In principle, the same measures applied to motor cables must be applied to all control signal cables, in accordance with the EMC-Directives. For all signal cables as mentioned in section 4.5.2 the best results are obtained if the screening is connected to both ends. See Fig. 36. NOTE: Each installation must be examined carefully before applying the proper EMC measurements. Fig. 36 Electro Magnetic (EM) screening of control signal cables.

Control board; Pressure sensor (example); External control (e.g. in metal housing); Control consol. Screening geometry remains in original drawing.

Control cable specifications — PDF page 30

Source row Signal type Maximum wire size Tightening torque Cable type
1 Analogue Rigid cable: 0.14-2.5 mm2 Flexible cable: 0.14-1.5 mm2 Cable with ferrule: 0.25-1.5 mm2 0.5 Nm Screened
2 Digital Rigid cable: 0.14-2.5 mm2 Flexible cable: 0.14-1.5 mm2 Cable with ferrule: 0.25-1.5 mm2 0.5 Nm Screened
3 Data Rigid cable: 0.14-2.5 mm2 Flexible cable: 0.14-1.5 mm2 Cable with ferrule: 0.25-1.5 mm2 0.5 Nm Screened
4 Relay Rigid cable: 0.14-2.5 mm2 Flexible cable: 0.14-1.5 mm2 Cable with ferrule: 0.25-1.5 mm2 0.5 Nm Not screened

Manual — Signal type and cable screening conditions — page 31

Manual reference: physical PDF page 31. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

4.5.5 Current signals ((0)4-20 mA) A current signal like (0)4-20 mA is less sensitive to disturbances than a 0-10 V signal, because it is con- nected to an input which has a lower impedance (250 Ω) than a voltage signal (20 kΩ). It is therefore strongly advised to use current control signals if the cables are longer than a few metres. 4.5.6 Twisted cables Analogue and digital signals are less sensitive to inter- ference if the cables carrying them are “twisted”. This is certainly to be recommended if screening cannot be used. By twisting the wires the exposed areas are mini- mised. This means that in the current circuit for any possible High Frequency (HF) interference fields, no voltage can be induced. For a PLC it is therefore impor- tant that the return wire remains in proximity to the sig- nal wire. It is important that the pair of wires is fully twisted over 360°. 4.6 Connecting options The option cards are connected by the optional connec- tors X4 or X5 on the control board see Fig. 30, page 23 and mounted above the control board. The inputs and outputs of the option cards are connected in the same way as other control signals.

Manual — Getting started and menu keys — page 32

Manual reference: physical PDF page 32. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Getting Started This chapter is a step by step guide that will show you the quickest way to get the motor shaft turning. We will show you two examples, remote control and local con- trol. We assume that the AC drive is mounted on a wall or in a cabinet as in the chapter 2. page 9. First there is general information of how to connect mains, motor and control cables. The next section describes how to use the function keys on the control panel. The subsequent examples covering remote con- trol and local control describe how to program/set the motor data and run the AC drive and motor. 5.1 Connect the mains and motor cables Dimension the mains and motor cables according to local regulations. The cable must be able to carry the AC drive load current. 5.1.1 Mains cables 1. Connect the mains cables as in Fig. 37. The AC drive has, as standard, a built-in RFI mains filter that com- plies with category C3 which suits the Second Envi- ronment standard. 5.1.2 Motor cables 2. Connect the motor cables as in Fig. 37. To comply with the EMC Directive you have to use screened cables and the motor cable screen has to be con- nected on both sides: to the housing of the motor and the housing of the AC drive. Fig. 37 Connection of mains and motor cables

Table 16 Mains and motor connection WARNING! In order to work safely the mains earth must be connected to PE and the motor earth to . 5.2 Using the function keys Fig. 38 Example of menu navigation when entering motor voltage

AC drive; RFI-Filter; Mains; L1,L2,L3,PE; DC−,DC+,R; motor earth,U,V,W. Metal EMC cable glands; Screened cables; Metal housing; Brake resistor (option); Output coils (option); Metal connector housing; Metal cable gland; Motor. Source reference06-F41. Circuit topology not inferred.

NEXT moves100→200→300; PREV moves back at same level. ENTER from200 to210; NEXT to220; ENTER to221. ESC goes up; +/− and ENTER used for edits. Read actual procedure separately.

ENTER: step to lower menu level or confirm changed setting. ESC: step to higher menu level or ignore changed setting. NEXT: step to next menu on same level. PREV: step to previous menu on same level. + increase value or change selection. − decrease value or change selection.

Literal physically aligned terminal pairs; motor earth graphic separate from mains PE. No circuit geometry inferred.

Table16 Mains and motor connections — PDF page 32

Source row Terminal Meaning
1 L1,L2,L3 Mains supply, 3 -phase
2 PE Safety earth
3 [motor earth symbol] Motor earth
4 U, V, W Motor output, 3-phase

Manual — Remote startup and motor data — page 33

Manual reference: physical PDF page 33. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

5.3 Remote control In this example external signals are used to control the AC drive/motor. A standard 4-pole motor for 400 V, an external start button and a reference value will also be used. 5.3.1 Connect control cables Here you will make up the minimum wiring for starting. In this example the motor/AC drive will run with right rotation. To comply with the EMC standard, use screened control cables with plaited flexible wire up to 1.5 mm2 or solid wire up to 2.5 mm2. 3. Connect a reference value between terminals 7 (Common) and 2 (AnIn 1) as in Fig. 39. 4. Connect an external start button between terminal 11 (+24 VDC) and 9 (DigIn2, RUNR) as in Fig. 39. Fig. 39 Wiring 5.3.2 Switch on the mains Close the door to the AC drive. Once the mains is switched on, the internal fan in the AC drive will run for 5 seconds. 5.3.3 Set the Motor Data Enter correct motor data for the connected motor. The motor data is used in the calculation of complete oper- ational data in the AC drive. Change settings using the keys on the control panel. For

further information about the control panel and menu structure, see the chapter 9. page 53. Menu [100], Preferred View is displayed when started. 5.3.4 Run the AC drive Now the installation is finished, and you can press the external start button to start the motor. When the motor is running the main connections are OK.

X1 terminals1–22; X2 relay terminals31,32,33 and41,42,43; X3 terminals51,52. Reference4–20mA; +;0V; Start. Explicit prose connects reference7(Common)/2(AnIn1), start11(+24VDC)/9(DigIn2,RUNR). All other connection geometry original-only.

  1. NEXT displays200 Main Setup. 2. ENTER then NEXT displays220 Motor Data. 3. ENTER displays221; set motor voltage. 4. Change with + and −, confirm ENTER. 5. Set frequency222. 6. Power223. 7. Current224. 8. Speed225. 9. Power factor (cos j)227. 10. Select supply voltage21B. 11. Motor ID229: choose Short, ENTER, then RunR. Drive measures parameters; motor beeps, shaft does not rotate; after about one minute Test Run OK! appears; STOP/RESET to continue. 12. AnIn1 reference default4–20mA; for0–10V change S1 and512 AnIn1Set-up to0–10V. 13. Switch off supply. 14. Connect digital/analog inputs/outputs as Figure39. 15. Ready! 16. Switch on supply.

Manual — Local startup key sequence — page 34

Manual reference: physical PDF page 34. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

5.4 Local control Manual control via the control panel can be used to carry out a test run. Use a 400 V motor and the control panel. 5.4.1 Switch on the mains Close the door to the AC drive. Once the mains is switched on, the AC drive is started and the internal fan will run for 5 seconds. 5.4.2 Select manual control Menu [100], Preferred View is displayed when started. 5.4.3 Set the Motor Data Enter correct motor data for the connected motor. 5.4.4 Enter a Reference Value Enter a reference value. 5.4.5 Run the AC drive If the motor is running the main connections are OK.

  1. NEXT→200 Main Setup. 2. ENTER→210 Operation. 3. ENTER→211 Language. 4. NEXT→214 Reference Control. 5. Keyboard via +, confirm ENTER. 6. NEXT→215 Run/Stop Control. 7. Keyboard via +, confirm ENTER. 8. ESC then NEXT→220 Motor Data.

  2. ENTER→221. 10. Change +/−, confirm ENTER. 11. NEXT→222. 12. Repeat steps9 and10 until all motor data entered. 13. ESC twice then PREV→100 Preferred View.

  3. NEXT until300 Process. 15. ENTER→310 Set/View reference. 16. +/− to enter example300rpm; source selects low value to check rotation direction without damaging application.

Press RunR key on control panel to run motor forward.

Manual — Getting Started — page 35

Manual reference: physical PDF page 35. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Crane and crusher application examples — page 36

Manual reference: physical PDF page 36. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Applications This chapter contains tables giving an overview of many different applications/duties in which it is suitable to use the AC drives. Further on you will find application examples of the most common applications and solu- tions. 6.1 Application overview 6.1.1Cranes 6.1.2Crushers

Crane application examples — PDF page 36

Source row Challenge V33 solution Menu
1 Starting with heavy load is difficult and risky. Can lead to jerks causing swinging load. Direct torque control, fast motor pre- magnetization and precise brake control gives instant yet soft start with heavy load. 331–338, 339, 351
2 Jerky movements can cause load to be dropped, jeopardizing safety of people and goods. Deviation control immediately detects load change. Signals to parallel safety system to activate mechanical brakes. 3AB, 3AC
3 Crane is driven slowly when returning empty or with light load. Valuable time is lost. Speed can be increased by field weakening. 343, 3AA, 3AD, 713
4 Braking with heavy load is difficult and risky. Can lead to jerks causing swinging load. Direct torque control and vector brake gradually reduce speed to zero before mechanical brake is activated. 213, 33E,33F, 33G
5 Operator starts braking long before end position to avoid jerks. Valuable time is lost. System automatically stops crane at end position. Operator can safely drive at full speed. 3A2–3AA

Crusher application examples — PDF page 36

Source row Challenge V33 solution Menu
1 High start currents require larger fuses and cables, or for mobile crushers larger diesel generators. Direct torque control reduces start current. Same fuses as those for the motor, or smaller generator. 331-338, 351
2 Difficult to start with heavy load. Possible to boost torque at start to overcome initial torque peak. 351–353
3 Material that could cause damage gets into the crusher. Load Curve Protection quickly detects deviation. Warning is sent or safety stop activated. 411–41C9
4 Process inefficiency due to e.g. broken feeder or worn jaw. Wasted energy, mechanical stress, and risk of process failure. Load Curve Protection quickly detects deviation from normal load. Warning is sent or safety stop activated. 411–41B, 41C1–41C9

Manual — Applications — page 37

Manual reference: physical PDF page 37. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Parameter sets and preset selection — page 38

Manual reference: physical PDF page 38. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Main Features This chapter contains descriptions of the main features of the AC drive. 7.1 Parameter sets Parameter sets are used if an application requires dif- ferent settings for different modes. For example, a machine can be used for producing different products and thus requires two or more maximum speeds and acceleration/deceleration times. With the four parame- ter sets different control options can be configured with respect to quickly changing the behaviour of the AC drive. It is possible to adapt the AC drive online to altered machine behaviour. This is based on the fact that at any desired moment any one of the four param- eter sets can be activated during Run or Stop, via the digital inputs or the control panel and menu [241]. Each parameter set can be selected externally via a dig- ital input. Parameter sets can be changed during opera- tion and stored in the control panel. NOTE: The only data not included in the parameter set is Motor data 1-4, (entered separately), language, communication settings, selected set, local remote, and keyboard locked. Define parameter sets When using parameter sets you first decide how to select different parameter sets. The parameter sets can be selected via the control panel, via digital inputs or via serial communication. All digital inputs and vir- tual inputs can be configured to select parameter set. The function of the digital inputs is defined in the menu [520]. Fig. 40 shows the way the parameter sets are activated via any digital input configured to Set Ctrl 1 or Set Ctrl 2. Fig. 40 Selecting the parameter sets

Select and copy parameter set The parameter set selection is done in menu [241], Select Set. First select the main set in menu [241], nor- mally A. Adjust all settings for the application. Usually most parameters are common and therefore it saves a lot of work by copying set A>B in menu [242]. When parameter set A is copied to set B you only change the parameters in the set that need to be changed. Repeat for C and D if used. With menu [242], Copy Set, it is easy to copy the com- plete contents of a single parameter set to another parameter set. If, for example, the parameter sets are selected via digital inputs, DigIn 3 is set to Set Ctrl 1 in menu [523] and DigIn 4 is set to Set Ctrl 2 in menu [524], they are activated as in Table 17. Activate the parameter changes via digital input by set- ting menu [241], Select Set to DigIn. Table 17 Parameter set NOTE: The selection via the digital inputs is immediately activated. The new parameter settings will be activated on-line, also during Run. NOTE: The default parameter set is parameter set A. Examples Different parameter sets can be used to easily change the setup of a AC drive to adapt quickly to different application requirements. For example when • a process needs optimized settings in different stages of the process, to - increase the process quality - increase control accuracy - lower maintenance costs - increase operator safety With these settings a large number of options are avail- able. Some ideas are given here: Multi frequency selection Within a single parameter set the 7 preset references can be selected via the digital inputs. In combination with the parameter sets, 28 preset references can be selected using all 4 digital inputs: DigIn1, 2 and 3 for selecting preset reference within one parameter set

Parameter SetA: Run/Stop; Torques; Controllers; Limits/Prot.; Max Alarm. SetB,SetC,SetD shown. 11 +24V;10 SetCtrl1;16 SetCtrl2. Reference NG06-F03_1. Graphic connections remain original.

Table17 Parameter set selection — PDF page 38

Source row Parameter set Set Ctrl1 Set Ctrl2
1 A 0 0
2 B 1 0
3 C 0 1
4 D 1 1

Manual — Motor switching and autoreset — page 39

Manual reference: physical PDF page 39. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

and DigIn 4 and DigIn 5 for selecting the parameter sets. Bottling machine with 3 different products Use 3 parameter sets for 3 different Jog reference speeds when the machine needs to be set up. The 4th parameter set can be used for “normal” remote control when the machine is running at full production. Product changing on winding machines If a machine has to change between 2 or 3 different products e.g. winding machine with different gauges of thread, it is important that acceleration, deceleration times, Max Speed and Max Torque are adapted. For each thread size a different parameter set can be used. Manual - automatic control If in an application something is filled up manually and then the level is automatically controlled using PID reg- ulation, this is solved using one parameter set for the manual control and one for the automatic control. 7.1.1 One motor and one parameter set This is the most common application for pumps and fans. Once default motor M1 and parameter set A have been selected: 1. Enter the settings for motor data. 2. Enter the settings for other parameters e.g. inputs and outputs 7.1.2 One motor and two parameter sets This application is useful if you for example have a machine running at two different speeds for different products. Once default motor M1 is selected: 1. Select parameter set A in menu [241]. 2. Enter motor data in menu [220]. 3. Enter the settings for other parameters e.g. inputs and outputs. 4. If there are only minor differences between the set- tings in the parameter sets, you can copy parameter set A to parameter set B, menu [242]. 5. Enter the settings for parameters e.g. inputs and outputs. Note: Do not change motor data in parameter set B.

7.1.3 Two motors and two parameter sets This is useful if you have a machine with two motors that can not run at the same time, such as a cable winding machine that lifts up the reel with one motor and then turns the wheel with the other motor. One motor must stop before changing to an other motor. 1. Select parameter set A in menu [241]. 2. Select motor M1 in menu [212]. 3. Enter motor data and settings for other parameters e.g. inputs and outputs. 4. Select parameter set B in menu [241]. 5. Select M2 in menu [212]. 6. Enter motor data and settings for other parameters e.g. inputs and outputs. 7.1.4 Autoreset at trip For several non-critical application-related failure conditions, it is possible to automatically generate a reset command to overcome the fault condition. The selection can be made in menu [250]. In this menu the maximum number of automatically generated restarts allowed can be set, see menu [251], after this the AC drive will stay in fault condition because external assist- ance is required. Example The motor is protected by an internal protection for ther- mal overload. When this protection is activated, the AC drive should wait until the motor is cooled down enough before resuming normal operation. When this problem occurs three times in a short period of time, external assistance is required. The following settings should be applied: • Insert maximum number of restarts; set menu [251] to 3. • Activate Motor I2t to be automatically reset; set menu [25A] to 300 s. • Set relay 1, menu [551] to AutoRst Trip; a signal will be available when the maximum number of restarts is reached and the AC drive stays in fault condition. • The reset input must be constantly activated. 7.1.5 Reference priority The active speed reference signal can be programmed from several sources and functions. The table below

Manual — Reference priority and remote controls — page 40

Manual reference: physical PDF page 40. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

shows the priority of the different functions with regards to the speed reference. Table 18 Reference priority 7.1.6 Preset references The AC drive is able to select fixed speeds via the con- trol of digital inputs. This can be used for situations where the required motor speed needs to be adapted to fixed values, according to certain process conditions. Up to 7 preset references can be set for each parame- ter set, which can be selected via all digital inputs that are set to Preset Ctrl1, Preset Ctrl2 or Preset Ctrl3. The amount digital inputs used that are set to Preset Ctrl determines the number of Preset References available; using 1 input gives 2 speeds, using 2 inputs gives 4 speeds and using 3 inputs gives 8 speeds. Example The use of four fixed speeds, at 50 / 100 / 300 / 800 rpm, requires the following settings: • Set DigIn 5 as first selection input; set [525] to Pre- set Ctrl1. • Set DigIn 6 as second selection input; set [526] to Preset Ctrl2. • Set menu [341], Min Speed to 50 rpm. • Set menu [362], Preset Ref 1 to 100 rpm. • Set menu [363], Preset Ref 2 to 300 rpm. • Set menu [364], Preset Ref 3 to 800 rpm. With these settings, the AC drive switched on and a RUN command given, the speed will be: • 50 rpm, when both DigIn 5 and DigIn 6 are low. • 100 rpm, when DigIn 5 is high and DigIn 6 is low. • 300 rpm, when DigIn 5 is low and DigIn 6 is high. • 800 rpm, when both DigIn 5 and DigIn 6 are high.

7.2 Remote control functions Operation of the Run/Stop/Enable/Reset functions As default, all the run/stop/reset related commands are programmed for remote operation via the inputs on the terminal strip (terminals 1-22) on the control board. With the function Run/Stp Ctrl [215] and Reset Control [216], this can be selected for keyboard or serial com- munication control. NOTE: The examples in this paragraph do not cover all possibilities. Only the most relevant combinations are given. The starting point is always the default setting (factory) of the AC drive. Default settings of the Run/Stop/ Enable/Reset functions The default settings are shown in Fig. 41. In this exam- ple the AC drive is started and stopped with DigIn 2 and a reset after trip can be given with DigIn 8. Fig. 41 Default setting Run/Reset commands The inputs are default set for level-control. The rotation is determined by the setting of the digital inputs.

RunR;Reset;+24V; X1 terminals1–22. Figure caption identifies default Run/Reset commands; no wiring mapping derived from diagram alone.

Table18 Reference priority — PDF page 40

Source row Jog mode Preset reference Motor pot Ref signal
1 On/Off On/Off On/Off Option cards
2 On On/Off On/Off Jog Ref
3 Off On On/Off Preset Ref
4 Off Off On Motor pot commands

Manual — Enable stop reset and restart behaviour — page 41

Manual reference: physical PDF page 41. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Enable and Stop functions Both functions can be used separately or simultane- ously. The choice of which function is to be used depends on the application and the control mode of the inputs (Level/Edge [21A]). NOTE: In Edge mode, at least one digital input must be programmed to “stop”, because the Run commands are otherwise only able to start the AC drive. Enable Input must be active (HI) to allow any Run signal. If the input is made LOW, the output of the AC drive is immediately disabled and the motor will coast. CAUTION! ! If the Enable function is not programmed to a digital input, it is considered to be active internally. Stop If the input is low then the AC drive will stop according to the selected stop mode set in menu [33B] Stop Mode. Fig. 42 shows the function of the Enable and the Stop input and the Stop Mode=Decel [33B]. To run the input must be high. NOTE: Stop Mode=Coast [33B] will give the same behaviour as the Enable input. Fig. 42 Functionality of the Stop and Enable input

Reset and Autoreset operation If the AC drive is in Stop Mode due to a trip condition, the AC drive can be remotely reset by a pulse (“low” to “high” transition) on the Reset input, default on DigIn 8. Depending on the selected control method, a restart takes place as follows: Level-control If the Run inputs remain in their position the AC drive will start immediately after the Reset command is given. Edge-control After the Reset command is given a new Run command must be applied to start the AC drive again. Autoreset is enabled if the Reset input is continuously active. The Autoreset functions are programmed in menu Autoreset [250]. NOTE: If the control commands are programmed for Keyboard control or Com, Autoreset is not possible.

STOP(STOP=DECEL); OUTPUT SPEED;t; ENABLE; OUTPUT SPEED;t; (or if Spinstart selected);06-F104_NG. Timing waveforms and curve shape remain original-only.

Manual — Level and edge run controls — page 42

Manual reference: physical PDF page 42. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Run Inputs Level-controlled. The inputs are set as default for level-control. This means that an input is activated by making the input continuously “High”. This method is commonly used if, for example, PLCs are used to operate the AC drive. CAUTION! ! Level-controlled inputs DO NOT comply with the Machine Directive, if the inputs are directly used to start and stop the machine. The examples given in this and the following para- graphs follow the input selection shown in Fig. 43. Fig. 43 Example of wiring for Run/Stop/Enable/Reset inputs The Enable input must be continuously active in order to accept any run-right or run-left command. If both RunR and RunL inputs are active, then the AC drive stops according to the selected Stop Mode. Fig. 44 gives an example of a possible sequence. Fig. 44 Input and output status for level-control

Run Inputs Edge-controlled Menu [21A] Start signal Level/Edge must be set to Edge to activate edge control. This means that an input is activated by a “low” to “high” transition or vice versa. NOTE: Edge-controlled inputs comply with the Machine Directive (see chapter EMC and Machine Directive), if the inputs are directly used for starting and stopping the machine. See Fig. 43. The Enable and Stop input must be active continuously in order to accept any run-right or run-left command. The last edge (RunR or RunL) is valid. Fig. 45 gives an example of a possible sequence. Fig. 45 Input and output status for edge-control

Stop;RunL;RunR;Enable;Reset;+24V; X1 terminals1–22. Wiring geometry remains in original.

INPUTS:ENABLE,STOP,RUNR,RUNL. OUTPUT STATUS:Right rotation;Left rotation;Standstill. Source06-F103new_1. Waveforms original-only.

INPUTS:ENABLE,STOP,RUNR,RUNL. OUTPUT STATUS:Right rotation;Left rotation;Standstill. Source06-F94new_1. Waveforms original-only.

Manual — Motor identification and panel memory — page 43

Manual reference: physical PDF page 43. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

7.3 Performing an Identification Run To get the optimum performance out of your AC drive/ motor combination, the AC drive must measure the electrical parameters (resistance of stator winding, etc.) of the connected motor. See menu [229], Motor ID-Run. It is recommended that the extended ID run be used before the motor is installed in the application. If this is not possible, the short ID run should be used. WARNING! During the extended ID RUN, the motor shaft will rotate. Take safety measures to avoid unforeseen dangerous situations. 7.4 Using the Control Panel Memory Data can be copied from the AC drive to the memory in the control panel and vice versa. To copy all data (including parameter set A-D and motor data) from the AC drive to the control panel, select Copy to CP[244], Copy to CP. To copy data from the control panel to the AC drive, enter the menu [245], Load from CP and select what you want to copy. The memory in the control panel is useful in applica- tions with VSDs without a control panel and in applica- tions where several AC drives have the same setup. It can also be used for temporary storage of settings. Use a control panel to upload the settings from one AC drive and then move the control panel to another AC drive and download the settings. NOTE: Load from and copy to the AC drive is only possible when the AC drive is in stop mode.

Fig. 46 Copy and load parameters between AC drive and control panel

Copy: AC drive to Control Panel; Load: Control Panel to AC drive. Original diagram/photo retained; no hidden display values inferred.

Manual — Load monitor and load curves — page 44

Manual reference: physical PDF page 44. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

7.5 Load Monitor and Process Protection [400] 7.5.1 Load Monitor [410] The monitor functions enable the AC drive to be used as a load monitor. Load monitors are used to protect machines and processes against mechanical overload and underload, such as a conveyer belt or screw con- veyer jamming, belt failure on a fan or a pump dry run- ning. The load is measured in the AC drive by the calculated motor shaft torque. There is an overload alarm (Max Alarm and Max Pre-Alarm) and an under- load alarm (Min Alarm and Min Pre-Alarm). The Basic Monitor type uses fixed levels for overload and underload (pre-)alarms over the whole speed range. This function can be used in constant load appli- cations where the torque is not dependent on the speed, e.g. conveyor belt, displacement pump, screw pump, etc. For applications with a torque that is dependent on the speed, the Load Curve monitor type is preferred. By measuring the actual load curve of the process, characteristically over the range of minimum speed to maximum speed, an accurate protection at any speed can be established. The max and min alarm can be set for a trip condition. The pre-alarms act as a warning condition. All the alarms can be monitored on the digital or relay outputs. The autoset function automatically sets the 4 alarm lev- els whilst running: maximum alarm, maximum pre- alarm, minimum alarm and minimum pre-alarm. Fig. 47 gives an example of the monitor functions for constant torque applications

Manual — Load monitor timing chart — page 45

Manual reference: physical PDF page 45. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Four phases: Ramp-up; Stationary underload example; Stationary overload example; Ramp-down. All phases411 Alarm Select=Max or Max0Min (literal source). Ramp phases413 Ramp Alarm=On; stationary phases413=On or Off. Torque[%];t[s]. Margins4161 MaxAlarmMar15%,4171 MaxPreAlMar10%,4181 MinPreAlMar10%,4191 MinAlarmMar15%;41B100% Default:T_NOM or Autoset:T_MOMENTARY. Output labels Max Alarm,Max PreAlarm,Min Alarm,Min PreAlarm. Ramp-up4162 MaxAlarmDel0.1s,4172 MaxPreAlDel0.1s,414 Start Delay0.2s. Stationary underload4182 MinPreAlDel0.1s and4192 MinAlarmDel0.1s. Stationary overload4162 MaxAlarmDel0.1s and4172 MaxPreAlDel0.1s. Ramp-down4182 MinPreAlDel0.1s and4192 MinAlarmDel0.1s. Start delay note: Must be elapsed before first (pre)alarm. Duration labels t and t′; note Must be <t (or t′) otherwise no (pre)alarm. Reference06-F96. Rotated chart read in enlarged landscape orientation. Output waveforms and arrow associations remain original; no inferred ordering or dynamic behaviour beyond written source.

Manual — Historical EMC and stop categories — page 46

Manual reference: physical PDF page 46. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. EMC and Machine Directive 8.1 EMC standards The AC drive complies with the following standards: EN(IEC)61800-3:2004 Adjustable speed electronic power drive systems, part 3, EMC product standards: Standard: category C3, for systems of rated supply voltage< 1000 VAC, intended for use in the second environment. Optional: Category C2, for systems of rated supply voltage <1.000 V, which is neither a plug in device nor a movable device and, when used in the first environ- ment, is intended to be installed and commissioned only by experienced person with the necessary skills in installing and/or commissioning AC drives including their EMC aspects. 8.2 Stop categories and emergency stop The following information is important if emergency stop circuits are used or needed in the installation where a AC drive is used. EN 60204-1 defines 3 stop categories: Category 0: Uncontrolled STOP: Stopping by switching off the supply voltage. A mechan- ical stop must be activated. This STOP may not be implemented with the help of a AC drive or its input/ output signals. Category 1: Controlled STOP: Stopping until the motor has come to rest, after which the mains supply is switched off. This STOP may not be implemented with the help of a AC drive or its input/ output signals.

Category 2: Controlled STOP: Stopping while the supply voltage is still present. This STOP can be implemented with each of the AC drives STOP command. WARNING! EN 60204-1 specifies that every machine must be provided with a category 0 stop. If the application prevents this from being implemented, this must be explicitly stated. Furthermore, every machine must be provided with an Emergency Stop function. This emergency stop must ensure that the voltage at the machine contacts, which could be dangerous, is removed as quickly as possible, without resulting in any other danger. In such an Emergency Stop situation, a category 0 or 1 stop may be used. The choice will be decided on the basis of the possible risks to the machine. NOTE: With option Safe Stop, a “Safe Torque Off (STO)” stop according EN-IEC 62061:2005 SIL 2 & EN-ISO 13849-1:2006, can be achieved. See chapter 13.10 page 179

Manual — EMC and Machine Directive — page 47

Manual reference: physical PDF page 47. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Control panel display and status codes — page 48

Manual reference: physical PDF page 48. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

This chapter describes how to use the control panel. The AC drive can be delivered with a control panel or a blank panel. 9.1 General The control panel displays the status of the AC drive and is used to set all the parameters. It is also possible to control the motor directly from the control panel. The control panel can be built-in or located externally via serial communication. The AC drive can be ordered without the control panel. Instead of the control panel there will be a blank panel. NOTE: The AC drive can run without the control panel being connected. However the settings must be such that all control signals are set for external use. 9.2 The control panel Fig. 48 Control panel 9.2.1The display The display is back lit and consists of 2 rows, each with space for 16 characters. The display is divided into six areas.

The different areas in the display are described below: Fig. 49 The display Area A: Shows the actual menu number (3 or 4 digits). Area B Shows if the menu is in the toggle loop or the AC drive is set for Local operation. Area C: Shows the heading of the active menu. Area D: Shows the status of the AC drive (3 digits). The following status indications are possi- ble: Acc : Acceleration Dec : Deceleration I2t : Active I2t protection Run : Motor runs Trp : Tripped Stp : Motor is stopped VL : Operating at Voltage limit SL : Operating at Speed limit CL : Operating at Current limit TL : Operating at Torque limit OT : Operating at Temperature Limit LV : Operating at Low Voltage Sby : Operating from Standby power supply SST : Operating Safe Stop, is flashing when activated LCL : Operating with low cooling liquid level Area E: Shows active parameter set and if it is a motor parameter. Area F: Shows the setting or selection in the active menu.This area is empty at the 1st level and 2nd level menu. This area also shows warn- ings and alarm messages. In some situa- tions this area could indicate +++ or - - - please see further information in chapter 9.2.2 page 46

  1. Operation via the Control Panel

LC Display;LEDs;Control Keys;Toggle Key;Function Keys. Visible panel keys reset,prev,next,esc,−,+,enter;TECO branding. Panel photo not product ratings.

LCD example221 T Motor Volt /Stp A M1:400V. AreasA actual menu number;B toggle/local;C active heading;D status;E parameter set/motor;F setting. Values are display examples only.

Manual — Menu examples and LED indications — page 49

Manual reference: physical PDF page 49. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 50 Example 1st level menu Fig. 51 Example 2nd level menu Fig. 52 Example 3d level menu Fig. 53 Example 4th level menu 9.2.2 Indications on the display The display can indicate +++ or - - - if a parameter is out of range. In the AC drive there are parameters which are dependent on other parameters. For example, if the speed reference is 500 and the maximum speed value is set to a value below 500, this will be indicated with +++ on the display. If the minimum speed value is set over 500, - - - is displayed. 9.2.3 LED indicators The symbols on the control panel have the following functions: Fig. 54 LED indications Table 19 LED indication

Table 19 LED indication NOTE: If the control panel is built in, the back light of the display has the same function as the Power LED in Table 19 (Blank panel LEDs).

300 Process Appl /StpA.

220 Motor Data /StpA.

221 Motor Volt /Stp A M1:400V.

4161 Max Alarm /Stp A 0.1s. Literal example retained; differs from chart4161 margin and4162 delay; not adopted as parameter specification.

Run Green;Trip Red;Power Green.

Table19 LED indications part1 — PDF page 49

Source row Symbol ON FLASHING OFF
1 POWER (green) Power on ---------------- Power off
2 TRIP (red) AC drive tripped Warning/Limit No trip

Table19 LED indications continued — PDF page 49

Source row Symbol ON FLASHING OFF
1 RUN (green) Motor shaft rotates Motor speed increase/ decrease Motor stopped

Manual — Control keys and toggle loop — page 50

Manual reference: physical PDF page 50. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

9.2.4 Control keys The control keys are used to give the Run, Stop or Reset commands directly. As default these keys are disabled, set for remote control. Activate the control keys by selecting Keyboard in the menus Ref Control [214] and Reset Ctrl [216]. If the Enable function is programmed on one of the dig- ital inputs, this input must be active to allow Run/Stop commands from the control panel. Table 20 Control keys NOTE: It is not possible to simultaneously activate the Run/Stop commands from the keyboard and remotely from the terminal strip (terminals 1-22). 9.2.5 The Toggle and Loc/Rem Key This key has two functions: Toggle and switching between Loc/Rem function. Press one second to use the toggle func- tion Press and hold the toggle key for more than five sec- onds to switch between Local and Remote function, depending on the settings in [2171] and [2172]. When editing values, the toggle key can be used to change the sign of the value, see section 9.5, page 49. Toggle function Using the toggle function makes it possible to easily step through selected menus in a loop. The toggle loop can contain a maximum of ten menus. As default the toggle loop contains the menus needed for Quick Setup. You can use the toggle loop to create a quick- menu for the parameters that are most importance to your specific application. NOTE: Do not keep the Toggle key pressed for more than five seconds without pressing either the +, - or Esc key, as this may activate the Loc/Rem function of this key instead. See menu [217]. Add a menu to the toggle loop 1. Go to the menu you want to add to the loop. 2. Press the Toggle key and keep it pressed while pressing the + key.

Delete a menu from the toggle loop 1. Go to the menu you want to delete using the toggle key. 2. Press the Toggle key and keep it pressed while pressing the - key. Delete all menus from the toggle loop 1. Press the Toggle key and keep it pressed while pressing the Esc key. 2. Confirm with Enter. The menu Preferred view [100] is displayed. Default toggle loop Fig. 55 shows the default toggle loop. This loop con- tains the necessary menus that need to be set before starting. Press Toggle to enter menu [211] then use the Next key to enter the sub menus [212] to [21A] and enter the parameters. When you press the Toggle key again, menu [221] is displayed. Fig. 55 Default toggle loop Indication of menus in toggle loop Menus included in the toggle loop are indicated with a in area B in the display.

LOC/REM toggle key.

Main loop visible labels100,211,221,331,341,511. Submenu examples212,213,222,228; NEXT;LOC/REM; Sub menus. Blank boxes not assigned values.

T symbol denotes menu included in toggle loop.

Key illustration: RUN L:

Key illustration: STOP/RESET:

Key illustration: RUN R:

Visible key labels and functions; associated graphic symbols retained separately; remote/local control restrictions remain in prose.

Adjacent source context — repeated to preserve continuation:

Table20 Control keys — PDF page 50

Source row Key Function
1 RUN L: gives a start with left rotation
2 STOP/RESET: stops the motor or resets the AC drive after a trip
3 RUN R: gives a start with right rotation

Manual — Local remote and function keys — page 51

Manual reference: physical PDF page 51. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Loc/Rem function The Loc/Rem function of this key is disabled as default. Enable the function in menu [2171] and/or [2172]. With the function Loc/Rem you can change between local and remote control of the AC drive from the con- trol panel. The function Loc/Rem can also be changed via the DigIn, see menu Digital inputs [520] Change control mode 1. Press the Loc/Rem key for five seconds, until Local? or Remote? is displayed. 2. Confirm with Enter. 3. Cancel with Esc. Local mode Local mode is used for temporary operation. When switched to LOCAL operation, the AC drive is controlled via the defined Local operation mode, i.e. [2171] and [2172]. The actual status of the AC drive will not change, e.g. Run/Stop conditions and the actual speed will remain exactly the same. When the AC drive is set to Local operation, the display will show L in area B in the display. The AC drive will be started and stopped using the keys on the control panel. The reference signal can be con- trolled using the + and - keys on the keyboard, when in the menu [310] according to the selection in Keyboard Reference menu [369]. Remote mode When the AC drive is switched to REMOTE operation, the AC drive will be controlled according to selected control methods in the menu’s Reference Control [214], Run/Stop Control [215] and Reset Control [216]. The actual operation status of the AC drive will reflect the status and settings of the programmed control selections, e.g. Start/Stop status and settings of the programmed control selections, acceleration or decel- eration speed according to the selected reference value in the menu Acceleration Time [331] / Deceleration Time [332]. To monitor the actual Local or Remote status of the AC drive control, a “Loc/Rem” function is available on the Digital Outputs or Relays. When the AC drive is set to Local, the signal on the DigOut or Relay will be active high, in Remote the signal will be inactive low. See menu Digital Outputs [540] and Relays [550].

9.2.6 Function keys The function keys operate the menus and are also used for programming and read-outs of all the menu set- tings. Table 21 Function keys Fig. 56 Menu structure 9.3 The menu structure The menu structure consists of 4 levels: This structure is consequently independent of the number of menus per level. For instance, a menu can have one selectable menu (Set/View Reference Value [310]), or it can have 17 selectable menus (menu Speeds [340]). NOTE: If there are more than 10 menus within one level, the numbering continues in alphabetic order.

Key illustration: ENTER key:

Key illustration: ESCAPE key:

Key illustration: PREVIOUS key:

Key illustration: NEXT key:

Key illustration: - key:

Key illustration: + key:

Visible key labels and functions; associated graphic symbols retained separately; remote/local control restrictions remain in prose.

Adjacent source context — repeated to preserve continuation:

Menu hierarchy levels — PDF page 51

Source row Level Meaning
1 Main Menu 1st level The first character in the menu number.
2 2nd level The second character in the menu number.
3 3rd level The third character in the menu number.
4 4th level The fourth character in the menu number.

Table21 Function keys — PDF page 51

Source row Key Function
1 ENTER key: - step to a lower menu level - confirm a changed setting
2 ESCAPE key: - step to a higher menu level - ignore a changed setting, without confirming
3 PREVIOUS key: - step to a previous menu within the same level - go to more significant digit in edit mode
4 NEXT key: - step to a next menu within the same level - go to less significant digit in edit mode
5 - key: - decrease a value - change a selection
6 + key: - increase a value - change a selection

Manual — Menu hierarchy and editing — page 52

Manual reference: physical PDF page 52. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 57 Menu structure 9.3.1The main menu This section gives you a short description of the func- tions in the Main Menu. 100 Preferred View Displayed at power-up. It displays the actual process value as default. Programmable for many other read- outs. 200 Main Setup Main settings to get the AC drive operable. The motor data settings are the most important. Also option utility and settings. 300 Process and Application Parameters Settings more relevant to the application such as Refer- ence Speed, torque limitations, PID control settings, etc. 400 Shaft Power Monitor and Process Protection The monitor function enables the AC drive to be used as a load monitor to protect machines and processes against mechanical overload and underload.

500 Inputs/Outputs and Virtual Connections All settings for inputs and outputs are entered here. 600 Logical Functions and Timers All settings for conditional signals are entered here. 700 View Operation and Status Viewing all the operational data like frequency, load, power, current, etc. 800 View Trip Log Viewing the last 10 trips in the trip memory. 900 Service Information and AC drive Data Electronic type label for viewing the software version and AC drive type. 9.4 Programming during operation Most of the parameters can be changed during opera- tion without stopping the AC drive. Parameters that can not be changed are marked with a lock symbol in the display. NOTE: If you try to change a function during operation that only can be changed when the motor is stopped, the message “Stop First” is displayed. 9.5 Editing values in a menu Most values in the second row in a menu can be changed in two different ways. Enumerated values like the baud rate can only be changed with alternative 1. Alternative 1 When you press the + or - keys to change a value, the cursor is flashing to the left in the display and the value is increased or decreased when you press the appropri- ate key. If you keep the + or - keys pressed, the value will increase or decrease continuously. When you keep the key pressed the change speed will increase. The Toggle key is used to change the sign of the entered value. The sign of the value will also change when zero is passed. Press Enter to confirm the value.

Main menus100,200,300,400,500,600,700,800,900. Second-level examples410,420; third-level411,412,413,414,415,416,417; fourth-level4161,4162. PREV,NEXT,ENTER,ESC arrows; referenceNG_06-F28. Source hierarchy only.

2621 Baudrate /Stp38400. Example display; distinct from control-panel RS232 fixed9600 specification.

331 Acc Time /Stp A 2.00s; Flashing.

Manual — Editing and parameter copy example — page 53

Manual reference: physical PDF page 53. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Alternative 2 Press the + or - key to enter edit mode. Then press the Prev or Next key to move the cursor to the right most position of the value that should be changed. The cur- sor will make the selected character flashes. Move the cursor using the Prev or Next keys. When you press the + or - keys, the character at the cursor position will increase or decrease. This alternative is suitable when you want to make large changes, i.e. from 2 s to 400 s. To change the sign of the value, press the toggle key. This makes it possible to enter negative values. Example: When you press Next the 4 will flash. Press Enter to save the setting and Esc to leave the edit mode. 9.6 Copy current parameter to all sets When a parameter is displayed, press the Enter key for 5 seconds. Now the text To all sets? is displayed. Press Enter to copy the setting for current parameter to all sets. 9.7 Programming example This example shows how to program a change of the Acc. Time set from 2.0 s to 4.0 s. The flashing cursor indicates that a change has taken place but is not saved yet. If at this moment, the power fails, the change will not be saved. Use the ESC, Prev, Next or the Toggle keys to proceed and to go to other menus.

Fig. 58 Programming example

331 Acc Time /Stp A 4.00s; Flashing. Example edit only.

100 0rpm /Stp A0.0A after power-up. NEXT→200 MAIN SETUP; NEXT→300 Process; ENTER→310 Set/View Ref; NEXT twice→330 Run/Stop; ENTER→331 Acc Time2.00s. Hold + to desired value; flashing display illustrated2.00s. ENTER saves changed value, final331 Acc Time4.00s. Stp A display examples, not product default claims.

Manual — Serial communications and parameter addresses — page 54

Manual reference: physical PDF page 54. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Serial communication The AC drive provides possibility for different types of serial communication. • Modbus RTU via RS232/485 • Fieldbuses as Profibus DP and DeviceNet • Industrial Ethernet as Modbus/TCP 10.1 Modbus RTU The AC drive has an asynchronous serial communica- tion interface behind the control panel. It is also possi- ble to use the isolated RS232/485 option board (if installed). The protocol used for data exchange is based on the Modbus RTU protocol, originally developed by Modicon. The physical connection is RS232. The AC drive acts as a slave with address 1 in a master-slave configuration. The communication is half-duplex. It has a standard non return zero (NRZ) format. The baud rate is fixed to 9600 (Control panel RS232 port). The character frame format (always 11 bits) has: • one start bit • eight data bits • two stop bits • no parity It is possible to temporarily connect a personal compu- ter with for example the software EmoSoftCom (pro- gramming and monitoring software) to the RS232 connector on the control panel. This can be useful when copying parameters between AC drives etc. For permanent connection of a personal computer you have to use one of the communication option boards. NOTE: This RS232 port is not isolated. WARNING! Correct and safe use of a RS232 connection depends on the ground pins of both ports being the same potential. Problems can occur when connecting two ports of e.g. machinery and computers where both ground pins are not the same potential. This may cause hazardous ground loops that can destroy the RS232 ports. The control panel RS232 connection is not galvanically isolated. The RS232/485 option board is galvanically isolated. Note that the control panel RS232 connection can safely be used in combination with commercial available isolated USB to RS232 converters.

Fig. 59 RS232 connector behind the control panel 10.2 Parameter sets Communication information for the different parameter sets. The different parameter sets in the AC drive have the following DeviceNet instance numbers and Profibus slot/index numbers: Parameter set A contains parameters 43001 to 43556. The parameter sets B, C and D contains the same type of information. For example parameter 43123 in parameter set A contain the same type of information as 44123 in parameter set B. A DeviceNet instance number can easily be converted into a Profibus slot/index number according to descrip- tion in section section 11.8.2, page 165.

RS232 behind control panel. Original connector photograph retained; no pin assignment inferred.

Parameter set addresses — PDF page 54

Source row Parameter set Modbus/DeviceNet instance Profibus slot/index
1 A 43001–43556 168/160 to 170/205
2 B 44001–44529 172/140 to 174/185
3 C 45001–45529 176/120 to 178/165
4 D 46001–46529 180/100 to 182/145

Manual — Motor addresses and communications commands — page 55

Manual reference: physical PDF page 55. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

10.3 Motor data Communication information for the different motors. M1 contains parameters 43041 to 43048. The M2, M3, and M4 contains the same type of information. For example parameter 43043 in motor M1 contain the same type of information as 44043 in M2. A DeviceNet instance number can easily be converted into a Profibus slot/index number according to descrip- tion in section section 11.8.2, page 165. 10.4 Start and stop commands Set start and stop commands via serial communica- tion. Note! Bipolar reference mode is activated if both RunR and RunL is active.

10.5 Reference signal When menu Reference Control [214] is set to “Com” the following parameter data should be used: Communication information 10.5.1 Process value It is also possible to send the Process value feedback signalover a bus (e.g. from a process or temperature sensor) for use with PID Process controller [380]. Set menu Process Source [321] to F(Bus). Use following parameter data for the process value: Communication information Example: (See the Fielbus manual for detalied information) We would like to control the AC drive over a bus system using the first two bytes of the Basic Control Message by setting menu [2661] FB Signal 1 to 49972. Further, we also want to transmit a 16 bit signed reference and a 16 bit process value. This is done by setting menu [2662] FB Signal 2 to 42905 and menu [2663] FB Sig- nal 3 to 42906. NOTE! It is possible to view the transmitted process value in control panel menu Operation [710]. The presented value is depending on settings in menus Process Min [324] and Process Max [325].

Motor data addresses — PDF page 55

Source row Motor Modbus/DeviceNet instance Profibus slot/index
1 M1 43041–43048 168/200 to 168/207
2 M2 44041–44048 172/180 to 174/187
3 M3 45041–45048 176/160 to 176/167
4 M4 46041–46048 180/140 to 180/147

Reference signal representation — PDF page 55

Source row Property Value
1 Default 0
2 Range -32768 to 32767
3 Corresponding to -100% to 100% ref

Reference signal address — PDF page 55

Source row Property Value
1 Modbus /DeviceNet Instance number 42905
2 Profibus slot /Index 168/64
3 Fieldbus format Int
4 Modbus format Int

Start and stop command addresses — PDF page 55

Source row Modbus/DeviceNet instance Function
1 42901 Reset
2 42902 Run, active together with either RunR or RunL to perform start.
3 42903 RunR
4 42904 RunL

Process value address — PDF page 55

Source row Property Value
1 Modbus /DeviceNet Instance number 42906
2 Profibus slot /Index 168/65
3 Fieldbus format Int
4 Modbus format Int

Manual — EInt formats and bit examples — page 56

Manual reference: physical PDF page 56. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

10.6 Description of the EInt formats A parameter with Eint format can be represented in two different formats (F). Either as a 15 bit unsigned integer format (F= 0) or a Floating point format (F=1). The most significant bit (B15) indicates the format used. See detailed description below. All parameters written to a register may be rounded to the number of significant digits used in the internal sys- tem. The matrix below describes the contents of the 16-bit word for the two different EInt formats: If the format bit (B15) is 0, then all bits may be treated as a standard unsigned integer (UInt) If the format bit is 1, then is the number interpreted as this: Value = M * 10^E, where M=m10..m0 represents a two- complement signed mantissa and E= e3..e0 repre- sents a two- complement signed exponent. NOTE: Parameters with EInt format may return values both as 15 bit unsigned int (F=0) or in Floating point (F=1). Example, resolution If you write the value 1004 to a register and this regis- ter has 3 significant digits, it will be stored as 1000. In the Floating point format (F=1), one 16-bit word is used to represent large (or very small numbers) with 3 significant digits. If data is read or written as a fixed point (i.e. no deci- mals) number between 0-32767, the 15 bit Unsigned integer format (F=0) may be used. Detailed description of Floating point format e3-e0 4-bit signed exponent. Gives a value range: -8..+7 (binary 1000 .. 0111) m10-m0 11-bit signed mantissa.Gives a value range: -1024..+1023 (binary 10000000000..01111111111)

A signed number should be represented as a two omplement binary number, like below: The value represented by the Floating point format is m·10e. To convert a value from the Floating point format to a floating point value, use the formula above. To convert a floating point value to the Floating point format, see the C-code example below. Example, Floating point format The number 1.23 would be represented by this in Float- ing point format, The value is then 123x10-2 = 1.23 Example 15bit unsigned int format The value 72.0 can be represented as the fixed point number 72. It is within the range 0-32767, which means that the 15-bit fixed point format may be used. The value will then be represented as: Where bit 15 indicates that we are using the fixed point format (F=0).

Columns B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0. Floating row: F=1,e3,e2,e1,e0,m10,m9,m8,m7,m6,m5,m4,m3,m2,m1,m0. Integer row: F=0,B14,B13,B12,B11,B10,B9,B8,B7,B6,B5,B4,B3,B2,B1,B0.

Value /Binary: −8/1000;−7/1001; ..;−2/1110;−1/1111;0/0000;1/0001;2/0010; ..;6/0110;7/0111. Ellipses are literal omissions in source, not generated rows.

F EEEE MMMMMMMMMMM =1 1110 00001111011. F=1 floating point; E=−2; M=123.

Columns B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0. Values0 0 0 0 0 0 0 0 0 1 0 0 1 0 0 0. F=0 fixed-point integer example72.

Manual — EInt supplier programming example — page 57

Manual reference: physical PDF page 57. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Programming example:

typedef struct

{

int m:11; // mantissa, -1024..1023

int e: 4; // exponent -8..7

unsigned int f: 1; // format, 1->special emoint format

} eint16;

//---------------------------------------------------------------------------

unsigned short int float_to_eint16(float value)

eint16 etmp;

int dec=0;

while (floor(value) != value && dec<16)

dec++; value*=10;

}

if (value>=0 && value<=32767 && dec==0)

(short int )&etmp=(short int)value;

else if (value>=-1000 && value<0 && dec==0)

etmp.e=0;

etmp.f=1;

etmp.m=(short int)value;

else

etmp.m=0;

etmp.e=-dec;

if (value>=0)

etmp.m=1; // Set sign

etmp.m=-1; // Set sign

value=fabs(value);

while (value>1000)

etmp.e++; // increase exponent

value=value/10;

value+=0.5; // round

etmp.m=etmp.m*value; // make signed

return ((unsigned short int )&etmp);

float eint16_to_float(unsigned short int value)

float f;

eint16 evalue;

evalue=(eint16 )&value;

if (evalue.f)

if (evalue.e>=0)

f=(int)evalue.m*pow10(evalue.e);

f=(int)evalue.m/pow10(abs(evalue.e));

f=value;

return f;

Manual — Menu reading conventions and first display line — page 58

Manual reference: physical PDF page 58. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

This chapter describes the menus and parameters in the software. You will find a short description of each function and information about default values, ranges, etc. There are also tables containing communication information. You will find the Modbus, DeviceNet and Fieldbus address for each parameter as well as the enumeration for the data. Description of table layout Resolution of settings The resolution for all range settings described in this chapter is 3 significant digits. Exceptions are speed val- ues which are presented with 4 significant digits. Table 22 shows the resolutions for 3 significant digits. Table 22 11.1 Preferred View [100] This menu is displayed at every power-up. During operation, the menu [100] will automatically be dis- played when the keyboard is not operated for 5 min- utes. The automatic return function will be switched off when the Toggle and Stop key is pressed simultane- ously. As default it displays the actual speed and torque.

Menu [100], Preferred View displays the settings made in menu [110], 1st line, and [120], 2nd line. See Fig. 60. Fig. 60 Display functions 11.1.1 1st Line [110] Sets the content of the upper row in the menu [100] Preferred View.” * The “Motor temp” is only visible if you have the option PTC/PT100 card installed and a PT100 input is selected in menu[ 236].

  1. Functional Description

NOTE: Functions marked with the [padlock symbol] cannot be changed during Run Mode.

100 0rpm /Stp A0.0Nm. Display illustration, not rated operating condition.

100 (1st line) /Stp A (2nd Line). Menu100 displays110first line and120second line.

110 1st Line Stp A Process Val

Table layout illustration: Menu no.;Menu name;Status;Selected value;Default: [blank];Selection or range;Integer value of selection;Description. This is a layout key, not an actual parameter.

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

110 First Line metadata — PDF page 58

Source row Property Source value
1 Default: Process Val
2 Dependent on menu ⟦blank source cell⟧

110 First Line selections — PDF page 58

Source row Selection Integer code Description
1 Process Val 0 Process value
2 Speed 1 Speed
3 Torque 2 Torque
4 Process Ref 3 Process reference
5 Shaft Power 4 Shaft power
6 El Power 5 Electrical power
7 Current 6 Current
8 Output volt 7 Output voltage
9 Frequency 8 Frequency
10 DC Voltage 9 DC voltage
11 Heatsink Tmp 10 Heatsink temperature
12 Motor Temp * 11 Motor temperature
13 AC drive Sta- tus 12 AC drive status
14 Run Time 13 Run Time
15 Energy 14 Energy
16 Mains Time 15 Mains time

Table22 Three-digit resolution — PDF page 58

Source row 3 Digit Resolution
1 0.01-9.99 0.01
2 10.0-99.9 0.1
3 100-999 1
4 1000-9990 10
5 10000-99900 100

Manual — Second display line and language — page 59

Manual reference: physical PDF page 59. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information 11.1.2 2nd Line [120] Sets the content of the lower row in the menu [100] Preferred View. Same selection as in menu [110].

11.2 Main Setup [200] The Main Setup menu contains the most important set- tings to get the AC drive operational and set up for the application. It includes different sub menus concerning the control of the unit, motor data and protection, utili- ties and automatic resetting of faults. This menu will instantaneously be adapted to build in options and show the required settings. 11.2.1 Operation [210] Selections concerning the used motor, AC drive mode, control signals and serial communication are described in this submenu and is used to set the AC drive up for the application. Language [211] Select the language used on the LC Display. Once the language is set, this selection will not be affected by the Load Default command. Communication information

120 2nd Line Stp A Torque

211 Language Stp A English

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

110 First Line communication continuation from PDF58 — PDF page 59

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43001
2 Profibus slot/index 168/160
3 Fieldbus format UInt
4 Modbus format UInt

120 Second Line metadata — PDF page 59

Source row Property Source value
1 Default: Torque

211 Language metadata — PDF page 59

Source row Property Source value
1 Default: English

211 Language selections — PDF page 59

Source row Selection Integer code Description
1 English 0 English selected
2 Svenska 1 Swedish selected
3 Nederlands 2 Dutch selected
4 Deutsch 3 German selected
5 Français 4 French selected
6 Español 5 Spanish selected
7 Руccкий 6 Russian selected
8 Italiano 7 Italian selected
9 Česky 8 Czech selected
10 Turkish 9 Turkish selected

211 Language communication — PDF page 59

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43011
2 Profibus slot/index 168/170
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Motor selection and drive mode — page 60

Manual reference: physical PDF page 60. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Select Motor [212] This menu is used if you have more than one motor in your application. Select the motor to define. It is possi- ble to define up to four different motors, M1 to M4, in the AC drive. Communication information Drive Mode [213] This menu is used to set the control mode for the motor. Settings for the reference signals and read-outs is made in menu Process source, [321]. • Speed Mode offers an accurate control of the motor speed independently of the load. The Speed mode also increases the accuracy of the different ana- logue output signals that are related to the motor speed. Speed mode can also be used if several motors of same type and size are connected in par- allel. Requires all motors to be mechanically con- nected to the load. • Torque Mode can be selected for applications where the motor shaft torque needs to be controlled inde- pendently of the speed. • V/Hz Mode (output speed [712] in rpm) is used when several motors in parallel of different type or size are connected or if parallel motors are not mechanically connected to the load.

Communication information

213 Drive Mode Stp A Speed

212 Select Motor Stp A M1

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

213 Drive Mode continuation selections — PDF page 60

Source row Selection Integer code Description
1 Torque 1 The AC drive is torque controlled. Reference given=torque reference without ramp. Speed and torque limit can be set. Using “direct torque control” as motor control method. NOTE: No ramps active in the AC drive. Care must be taken.
2 V/Hz 2 All control loops are related to frequency control. NOTE: All the functions and menu read-outs with regard to speed and rpm (e.g. Max Speed = 1500 rpm, Min Speed=0 rpm, etc.) remain speed and rpm, although they represent the output frequency.

212 Select Motor metadata — PDF page 60

Source row Property Source value
1 Default: M1

212 Select Motor selections — PDF page 60

Source row Selection Integer code Description
1 M1 0 Motor Data is connected to selected motor.
2 M2 1 Motor Data is connected to selected motor.
3 M3 2 Motor Data is connected to selected motor.
4 M4 3 Motor Data is connected to selected motor.

212 Select Motor communication — PDF page 60

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43012
2 Profibus slot/index 168/171
3 Fieldbus format UInt
4 Modbus format UInt

213 Drive Mode communication — PDF page 60

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43013
2 Profibus slot/index 168/172
3 Fieldbus format UInt
4 Modbus format UInt

213 Drive Mode metadata — PDF page 60

Source row Property Source value
1 Default: Speed

213 Drive Mode selections — PDF page 60

Source row Selection Integer code Description
1 Speed 0 The AC drive is speed controlled. Reference given=speed reference with ramp. Speed and torque limits can be set. Using “direct torque control” as motor control method.

Manual — Reference and run stop control — page 61

Manual reference: physical PDF page 61. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Reference control [214] To control the speed of the motor, the AC drive needs a reference signal. This reference signal can be con- trolled by a remote source from the installation, the key- board of the AC drive, or by serial or fieldbus communication. Select the required reference control for the application in this menu. NOTE: If the reference is switched from Remote to Keyboard, the last remote reference value will be the default value for the control panel. Communication information

Run/Stop Control [215] This function is used to select the source for run and stop commands. Start/stop via analogue signals can be achieved by combining a few functions. This is described in the Chapter 7.2 page 37. Communication information

215 Run/Stp Ctrl Stp A Remote

214 Ref Control Stp A Remote

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

215 Run Stop Control metadata — PDF page 61

Source row Property Source value
1 Default: Remote

215 Run Stop Control selections — PDF page 61

Source row Selection Integer code Description
1 Remote 0 The start/stop signal comes from the digital inputs of the terminal strip (terminals 1-22). For settings, see menu group [330] and [520].
2 Keyboard 1 Start and stop is set on the Control Panel.
3 Com 2 The start/stop is set via the serial communication (RS 485, Fieldbus.) See Fieldbus or RS232/485 option manual for details.
4 Option 3 The start/stop is set via an option.

214 Reference Control selections — PDF page 61

Source row Selection Integer code Description
1 Remote 0 The reference signal comes from the analogue inputs of the terminal strip (terminals 1-22).
2 Keyboard 1 Reference is set with the + and - keys on the Control Panel. Can only be done in menu Set/View reference [310].
3 Com 2 The reference is set via the serial communication (RS 485, Fieldbus.) See section section 10.5 for further information.
4 Option 3 The reference is set via an option. Only available if the option can control the reference value.

215 Run Stop communication — PDF page 61

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43015
2 Profibus slot/index 168/174
3 Fieldbus format UInt
4 Modbus format UInt

214 Reference communication — PDF page 61

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43014
2 Profibus slot/index 168/173
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Reset and local controls — page 62

Manual reference: physical PDF page 62. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Reset Control [216] When the AC drive is stopped due to a failure, a reset command is required to make it possible to restart the AC drive. Use this function to select the source of the reset signal. Communication information

Local/Remote key function [217] The Toggle key on the keyboard, see section 9.2.5, page 54, has two functions and is activated in this menu. As default the key is just set to operate as a Tog- gle key that moves you easily through the menus in the toggle loop. The second function of the key allows you to easily swap between Local and normal operation (set up via [214] and [215]) of the AC drive. Local mode can also be activated via a digital input. If both [2171] and [2172] is set to Standard, the function is disabled. Communication information Communication information

216 Reset Ctrl Stp A Remote

2171 LocRefCtrl Stp A Standard

2172 LocRunCtrl Stp A Standard

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

216 Reset Control metadata — PDF page 62

Source row Property Source value
1 Default: Remote

216 Reset Control selections — PDF page 62

Source row Selection Integer code Description
1 Remote 0 The command comes from the inputs of the terminal strip (terminals 1-22).
2 Keyboard 1 The command comes from the command keys of the Control Panel.
3 Com 2 The command comes from the serial communication (RS 485, Fieldbus).
4 Remote + Keyb 3 The command comes from the inputs of the terminal strip (terminals 1-22) or the keyboard.
5 Com + Keyb 4 The command comes from the serial communication (RS485, Fieldbus) or the keyboard.
6 Rem+Keyb +Com 5 The command comes from the inputs of the terminal strip (terminals 1-22), the keyboard or the serial communication (RS485, Fieldbus).
7 Option 6 The command comes from an option. Only available if the option can control the reset command.

2171 Local Reference Control metadata — PDF page 62

Source row Property Source value
1 Default: Standard

2171 Local Reference Control selections — PDF page 62

Source row Selection Integer code Description
1 Standard 0 Local reference control set via [214]
2 Remote 1 Local reference control via remote
3 Keyboard 2 Local reference control via keyboard
4 Com 3 Local reference control via communication

2171 communication — PDF page 62

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43009
2 Profibus slot/index 168/168
3 Fieldbus format UInt
4 Modbus format UInt

2172 Local Run Control selections — PDF page 62

Source row Selection Integer code Description
1 Standard 0 Local Run/Stop control set via [215]
2 Remote 1 Local Run/Stop control via remote
3 Keyboard 2 Local Run/Stop control via keyboard
4 Com 3 Local Run/Stop control via communication

216 communication — PDF page 62

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43016
2 Profibus slot/index 168/175
3 Fieldbus format UInt
4 Modbus format UInt

2172 communication — PDF page 62

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43010
2 Profibus slot/index 168/169
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Keyboard lock rotation and edge control — page 63

Manual reference: physical PDF page 63. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Lock Code [218] To prevent the keyboard being used or to change the setup of the AC drive and/or process control, the key- board can be locked with a password. This menu, Lock Code [218], is used to lock and unlock the keyboard. Enter the password “291” to lock/unlock the keyboard operation. If the keyboard is not locked (default) the selection “Lock Code?” will appear. If the keyboard is already locked, the selection “Unlock Code?” will appear. When the keyboard is locked, parameters can be viewed but not changed. The reference value can be changed and the AC drive can be started, stopped and reversed if these functions are set to be controlled from the keyboard. Rotation [219] Overall limitation of motor rotation direction This function limits the overall rotation, either to left or right or both directions. This limit is prior to all other selections, e.g.: if the rotation is limited to right, a Run- Left command will be ignored. To define left and right rotation we assume that the motor is connected U-U, V- V and W-W. Speed Direction and Rotation The speed direction can be controlled by: • RunR/RunL commands on the control panel. • RunR/RunL commands on the terminal strip (terminals 1-22). • Via the serial interface options. • The parameter sets. Fig. 61 Rotation

In this menu you set the general rotation for the motor. Communication information 11.2.2 Remote Signal Level/Edge [21A] In this menu you select the way to control the inputs for RunR, RunL and Reset that are operated via the digital inputs on the terminal strip. The inputs are default set for level-control, and will be active as long as the input is made and kept high. When edge-control is selected, the input will be activated by the low to high transition of the input. See Chapter 7.2 page 37 for more informa- tion. Communication information CAUTION! ! Level controlled inputs DO NOT comply with the Machine Directive if the inputs are directly used to start and stop the machine.

Right;Left arrows beside motor. Prose defines motor connected U-U,V-V,W-W; directional geometry remains original, no viewpoint inference.

219 Rotation Stp A R+L

218 Lock Code Stp A 0

21A Level/Edge Stp A Level

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

219 Rotation metadata — PDF page 63

Source row Property Source value
1 Default: R + L

219 Rotation selections — PDF page 63

Source row Selection Integer code Description
1 R 1 Speed direction is limited to right rotation. The input and key RunL are disabled.
2 L 2 Speed direction is limited to left rotation. The input and key RunR are disabled.
3 R+L 3 Both speed directions allowed.

219 communication — PDF page 63

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43019
2 Profibus slot/index 168/178
3 Fieldbus format UInt
4 Modbus format UInt

218 Lock Code metadata — PDF page 63

Source row Property Source value
1 Default: 0
2 Range: 0–9999

21A Level Edge metadata — PDF page 63

Source row Property Source value
1 Default: Level

21A Level Edge selections — PDF page 63

Source row Selection Integer code Description
1 Level 0 The inputs are activated or deactivated by a continuous high or low signal. Is commonly used if, for example, a PLC is used to operate the AC drive.
2 Edge 1 The inputs are activated by a transition; for Run and Reset from “low” to “high” and for Stop from "high" to "low".

21A communication — PDF page 63

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43020
2 Profibus slot/index 168/179
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Supply voltage and motor setup — page 64

Manual reference: physical PDF page 64. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

The default settings are for a standard 4-pole motor according to the nominal power of the AC drive.

No numerical current or speed default is established by this context.

NOTE: Edge controlled inputs can comply with the Machine Directive (see the Chapter 8. page 51) if the inputs are directly used to start and stop the machine. 11.2.3 Mains supply voltage [21B] WARNING! This menu must be set according to the AC drive product lable and the supply voltage used. Wrong setting might damage the AC drive or brake resistor. In this menu the nominal mains supply voltage con- nected to the AC drive can be selected. The setting will be valid for all parameter sets. The default setting, Not defined, is never selectable and is only visible until a new value is selected. Once the supply voltage is set, this selection will not be affected by the Load Default command [243]. Brake chopper activation level is adjusted using the set- ting of [21B]. NOTE: The setting is affected by the Load from CP command [245] and if loading parameter file via EmoSoftCom. Communication information

11.2.4 Motor Data [220] In this menu you enter the motor data to adapt the AC drive to the connected motor. This will increase the con- trol accuracy as well as different read-outs and ana- logue output signals. Motor M1 is selected as default and motor data entered will be valid for motor M1. If you have more than one motor you need to select the correct motor in menu [212] before entering motor data. NOTE 1: The parameters for motor data cannot be changed during run mode. NOTE 3: Parameter set cannot be changed during run if the sets is set for different motors. NOTE 4: Motor Data in the different sets M1 to M4 can be revert to default setting in menu [243], Default>Set. WARNING! Enter the correct motor data to prevent dangerous situations and assure correct control. Motor Voltage [221] Set the nominal motor voltage. NOTE: The Motor Volts value will always be stored as a 3 digit value with a resolution of 1 V. Communication information

21B Supply Volts Stp A Not defined

221 Motor Volts Stp A M1: 400V; [padlock symbol: cannot change during Run Mode]

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

21B Mains Supply Voltage metadata — PDF page 64

Source row Property Source value
1 Default: Not defined

21B Mains Supply Voltage selections — PDF page 64

Source row Selection Integer code Description
1 Not Defined 0 Inverter default value used. Only valid if this parameter is never set.
2 220-240 V 1 Only valid for JNVX48
3 380-415 V 3 Only valid for JNVX48/52
4 440-480 V 4 Only valid for JNVX48/52
5 500-525 V 5 Only valid for JNVX52/69
6 550-600 V 6 Only valid for JNVX69
7 660-690 V 7 Only valid for JNVX69

221 Motor Voltage metadata — PDF page 64

Source row Property Source value
1 Default: 400 V for JNVX 48 500 V for JNVX 52 690 V for JNVX 69
2 Range: 100-700 V
3 Resolution 1 V

21B communication — PDF page 64

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43381
2 Profibus slot/index 170/30
3 Fieldbus format UInt
4 Modbus format UInt

221 communication — PDF page 64

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43041
2 Profibus slot/index 168/200
3 Fieldbus format Long, 1=0.1 V
4 Modbus format EInt

Manual — Motor data parameters [222]–[225] — page 65

Manual reference: physical PDF page 65. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

[222] Set the nominal motor frequency.

[223] Set the nominal motor power. If paralell motors, set the value as sum of motors power.

[223] NOTE: The Motor Power value will always be stored as a 3 digit value in W up to 999 W and in kW for all higher powers.

[223] P_NOM is the nominal AC drive power.

[224] Set the nominal motor current. If paralell motors, set the value as sum of motors current.

[224] NOTE: The default settings are for a standard 4-pole motor according to the nominal power of the AC drive.

[224] WARNING! Do not connect motors with less than 25% of the nominal power of the AC drive. This may disrupt the control of the motor.

[225] Set the nominal asynchronous motor speed.

[225] WARNING! Do NOT enter a synchronous (no-load) motor speed.

[225] NOTE: Maximum speed [343] is not automatically changed when the motor speed is changed.

[225] NOTE: Entering a wrong, too low value can cause a dangerous situation for the driven application due to high speeds.

Two-column layout: read each column separately; sorted native text interleaves unrelated parameters.

LCD examples are source illustrations, not a measurement or model-specific factory rating.

Subscripts flattened as P_NOM, I_MOT, I_NOM and n_MOT. No numerical values inferred for symbols.

Motor Speed [225] Modbus format continues on PDF66. Its value is recorded separately with PDF66 provenance.

Defaults refer to Note 2 on printed page 61 / physical page 64; read that note with this table.

Motor data parameter; not an output-frequency performance envelope.

Source printed communication table for this menu only.

Symbolic nominal power retained; P_NOM is nominal AC drive power. Source prints subscript NOM and adjacent VSD.

Symbolic default; do not substitute a current from another model.

Nominal asynchronous motor speed parameter; all source warnings retained.

Final Modbus format row is on PDF66; not inferred from the Fieldbus format.

Motor Frequency [222] — PDF page 65

Source row Printed label Source value
1 Default 50 Hz
2 Range 24-300 Hz
3 Resolution 1 Hz
4 LCD illustration 222 Motor Freq; Stp A M1: 50Hz

[222] communication information — PDF page 65

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43042
2 Profibus slot/index 168/201
3 Fieldbus format Long, 1=1 Hz
4 Modbus format EInt

Motor Power [223] — PDF page 65

Source row Printed label Source value
1 Default P_NOM VSD
2 Range 1W-120% x P_NOM
3 Resolution 3 significant digits
4 LCD illustration 223 Motor Power; Stp A M1: (P_NOM)kW

[223] communication information — PDF page 65

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43043
2 Profibus slot/index 168/202
3 Fieldbus format Long, 1=1 W
4 Modbus format EInt

Motor Current [224] — PDF page 65

Source row Printed label Source value
1 Default I_MOT (see Note 2 page 61)
2 Range 25 - 150% x I_NOM
3 LCD illustration 224 Motor Curr; Stp A M1: (I_MOT)A

[224] communication information — PDF page 65

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43044
2 Profibus slot/index 168/203
3 Fieldbus format Long, 1=0.1 A
4 Modbus format EInt

Motor Speed [225] — PDF page 65

Source row Printed label Source value
1 Default n_MOT (see Note 2 page 61)
2 Range 50 - 18000 rpm
3 Resolution 1 rpm, 4 sign digits
4 LCD illustration 225 Motor Speed; Stp A M1: (n_MOT)rpm

[225] communication information — PDF page 65

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43045
2 Profibus slot/index 168/204
3 Fieldbus format UInt; 1=1 rpm

Manual — Motor poles power factor and ventilation — page 66

Manual reference: physical PDF page 66. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

The top-left continuation row belongs to the preceding source context.

Motor Poles [226] When the nominal speed of the motor is ≤500 rpm, the additional menu for entering the number of poles, [226], appears automatically. In this menu the actual pole number can be set which will increase the control accuracy of the AC drive. Communication information Motor Cos ϕ [227] Set the nominal Motor cosphi (power factor). Communication information

Motor ventilation [228] Parameter for setting the type of motor ventilation. Affects the characteristics of the I2t motor protection by lowering the actual overload current at lower speeds. Communication information When the motor has no cooling fan, None is selected and the current level is limited to 55% of rated motor current. With a motor with a shaft mounted fan, Self is selected and the current for overload is limited to 87% from 20% of synchronous speed. At lower speed, the overload cur- rent allowed will be smaller. When the motor has an external cooling fan, Forced is selected and the overload current allowed starts at 90% from rated motor current at zero speed, up to nominal motor current at 70% of synchronous speed. Fig. 62 shows the characteristics with respect for Nomi- nal Current and Speed in relation to the motor ventila- tion type selected. Fig. 62 I2t curves

Vertical xI_nom for I²t labels1.00,0.90,0.87,0.55; horizontal xSync Speed0.20,0.70,2.00. Curves labeled Forced,Self,None. Original geometry authoritative; only explicit source prose determines stated relationships.

228 Motor Vent Stp A M1: Self; [padlock symbol: cannot change during Run Mode]

226 Motor Poles Stp A M1: 4; [padlock symbol: cannot change during Run Mode]

227 Motor Cosϕ Stp A M1:CosφNOM; [padlock symbol: cannot change during Run Mode]

Only the top-left continuation row is transcribed; other menus and figure on PDF66 remain pending.

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

[225] communication continuation from PDF65 — PDF page 66

Source row Printed label Source value
1 Modbus format UInt

228 Motor Ventilation metadata — PDF page 66

Source row Property Source value
1 Default: Self

228 Motor Ventilation selections — PDF page 66

Source row Selection Integer code Description
1 None 0 Limited I2t overload curve.
2 Self 1 Normal I2t overload curve. Means that the motor stands lower current at low speed.
3 Forced 2 Expanded I2t overload curve. Means that the motor stands almost the whole current also at lower speed.

226 Motor Poles metadata — PDF page 66

Source row Property Source value
1 Default: 4
2 Range: 2-144

226 communication — PDF page 66

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43046
2 Profibus slot/index 168/205
3 Fieldbus format Long, 1=1 pole
4 Modbus format EInt

228 communication — PDF page 66

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43048
2 Profibus slot/index 168/207
3 Fieldbus format UInt
4 Modbus format UInt

227 Motor Cosphi metadata — PDF page 66

Source row Property Source value
1 Default: CosφNOM (see Note 2 page 61)
2 Range: 0.50 - 1.00

227 communication — PDF page 66

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43047
2 Profibus slot/index 168/206
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

Manual — Motor identification and encoder parameters [229], [22B]–[22D] — page 67

Manual reference: physical PDF page 67. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

[229] This function is used when the AC drive is put into operation for the first time. To achieve an optimal control performance, fine tuning of the motor parameters using a motor ID run is needed. During the test run the display shows “Test Run” flashing.

[229] To activate the Motor ID run, select either “Short” or “Extended” and press Enter. Then press RunL or RunR on the control panel to start the ID run. If menu [219] Rotation is set to L the RunR key is inactive and vice versa. The ID run can be aborted by giving a Stop command via the control panel or Enable input. The parameter will automatically return to OFF when the test is completed. The message “Test Run OK!” is displayed. Before the AC drive can be operated normally again, press the STOP/RESET key on the control panel.

[229] During the Short ID run the motor shaft does not rotate. The AC drive measures the rotor and stator resistance.

[229] During the Extended ID run the motor is powered on and rotates. The AC drive measures the rotor and stator resistance as well as the induction and the inertia for the motor.

[229] WARNING! During the extended ID RUN, the motor will rotate. Take safety measures to avoid unforeseen dangerous situations.

[229] NOTE: To run the AC drive it is not mandatory for the ID RUN to be executed, but without it the performance will not be optimal.

[229] NOTE: If the ID Run is aborted or not completed the message “Interrupted!” will be displayed. The previous data do not need to be changed in this case. Check that the motor data are correct.

[22B] Only visible if the Encoder option board is installed. This parameter enables or disables the encoder feedback from the motor to the AC drive.

[22C] Only visible if the Encoder option board is installed. This parameter describes the number of pulses per rotation for your encoder, i.e. it is encoder specific. For more information please see the encoder manual.

[22D] Only visible if the Encoder option board is installed. This parameter shows the measured motor speed. To check if the encoder is correctly installed, set Encoder Feedback [22B] to Off, run the AC drive at any speed and compare with the value in this menu. The value in this menu [22D] should be about the same as the motor speed [712]. If you get the wrong sign for the value, swap encoder input A and B.

Two-column layout, with independent parameter sections and communication tables.

Encoder sections explicitly require the Encoder option board; no inference that this option is supplied with all V33 drives.

LCD examples retained as illustrations. Encoder Speed [22D] communication table continues on PDF68, recorded separately.

Resolution for [22D] is literally a descriptive phrase in the source, not a numerical resolution.

Retain the complete operating conditions, abort procedure and rotation warning.

Source menu choices; load disconnection instruction and motor-rotation warning retained.

Source printed communication table for this menu only.

Only visible if Encoder option board installed.

Encoder option board condition applies.

Encoder-specific pulses per rotation; see encoder manual. Option board required.

Monitoring parameter with option-board requirement; no numeric resolution inferred.

Motor Identification Run [229] — PDF page 67

Source row Printed label Source value
1 Default Off, see Note
2 LCD illustration 229 Motor ID-Run; Stp A M1: Off

[229] choices — PDF page 67

Source row Choice Code Source description
1 Off 0 Not active
2 Short 1 Parameters are measured with injected DC current. No rotation of the shaft will occur.
3 Extended 2 Additional measurements, not possible to perform with DC current, are done directly after a short ID run. The shaft will rotate and must be disconnected from the load.

[229] communication information — PDF page 67

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43049
2 Profibus slot/index 168/208
3 Fieldbus format UInt
4 Modbus format UInt

Encoder Feedback [22B] — PDF page 67

Source row Printed label Source value
1 Default Off
2 LCD illustration 22B Encoder; Stp A M1: Off

[22B] choices — PDF page 67

Source row Choice Code Source description
1 Off 0 Encoder feedback disabled
2 On 1 Encoder feedback enabled

[22B] communication information — PDF page 67

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43051
2 Profibus slot/index 168/210
3 Fieldbus format UInt
4 Modbus format UInt

Encoder Pulses [22C] — PDF page 67

Source row Printed label Source value
1 Default 1024
2 Range 5–16384
3 LCD illustration 22C Enc Pulses; Stp A M1: 1024

[22C] communication information — PDF page 67

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 43052
2 Profibus slot/index 168/211
3 Fieldbus format Long, 1=1 pulse
4 Modbus format EInt

Encoder Speed [22D] — PDF page 67

Source row Printed label Source value
1 Unit rpm
2 Resolution speed measured via the encoder
3 LCD illustration 22D Enc Speed; Stp A M1: XXrpm

Manual — Encoder pulses and I2t protection — page 68

Manual reference: physical PDF page 68. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

The Sine Filt note below the top-left communication table is not assigned to [22D].

Communication information NOTE: Switching frequency is fixed when “Sine Filt” is selected. This means that it is not possible to control the switching frequency based on temperature. Encoder Pulse counter [22F] Only visible if the Encoder option is installed. Added menu/parameter for accumulated QEP (Quadrature Encoder Pulse) encoder pulses. Can be preset to any value within bus format used (Int = 2 byte, Long = 4 byte). Communication information Note! For a 1024 pulse encoder [22F] will count 1024 * 4= 4096 pulses per turn.

11.2.5 Motor Protection [230] This function protects the motor against overload based on the standard IEC 60947-4-2. Motor I2t Type [231] The motor protection function makes it possible to pro- tect the motor from overload as published in the stand- ard IEC 60947-4-2. It does this using Motor I2t Current, [232] as a reference. The Motor I2t Time [233] is used to define the time behaviour of the function. The cur- rent set in [232] can be delivered infinite in time. If for instance in [233] a time of 1000 s is chosen the upper curve of Fig. 63 is valid. The value on the x-axis is the multiple of the current chosen in [232]. The time [233] is the time that an overloaded motor is switched off or is reduced in power at 1.2 times the current set in [232]. Communication information NOTE: When Mot I2t Type=Limit, the AC drive can control the speed < MinSpeed to reduce the motor current.

231 Mot I2t Type Stp A M1: Trip

22F Enc Puls Ctr Stp A 0

Only the top-left communication table is transcribed. The Sine Filt note below is not assigned to [22D]; other menus, warnings and tables remain pending.

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

[22D] communication continuation from PDF67 — PDF page 68

Source row Printed label Source value
1 Modbus Instance no/DeviceNet no 42911
2 Profibus slot/index 168/70
3 Fieldbus format Int
4 Modbus format Int

231 Motor I2t Type metadata — PDF page 68

Source row Property Source value
1 Default: Trip

231 Motor I2t Type selections — PDF page 68

Source row Selection Integer code Description
1 Off 0 I2t motor protection is not active.
2 Trip 1 When the I2t time is exceeded, the AC drive will trip on “Motor I2t”.
3 Limit 2 This mode helps to keep the inverter run- ning when the Motor I2t function is just before tripping the AC drive. The trip is replaced by current limiting with a maxi- mum current level set by the value out of the menu [232]. In this way, if the reduced current can drive the load, the AC drive continues running.

22F Encoder Pulse Counter metadata — PDF page 68

Source row Property Source value
1 Default: 0
2 Resolutione 1

22F communication — PDF page 68

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42912
2 Profibus slot/index 168/71
3 Fieldbus format Long, 1=1 quad encoder pulse
4 Modbus format Int

231 communication — PDF page 68

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43061
2 Profibus slot/index 168/220
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Motor I2t current time and characteristic — page 69

Manual reference: physical PDF page 69. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Motor I2t Current [232] Sets the current limit for the motor I2t protection. Communication information NOTE: When the selection Limit is set in menu [231], the value must be above the no-load current of the motor. Fig. 63 I2t function Fig. 63 shows how the function integrates the square of the motor current according to the Mot I2t Curr [232] and the Mot I2t Time [233]. When the selection Trip is set in menu [231] the AC drive trips if this limit is exceeded. When the selection Limit is set in menu [231] the AC drive reduces the torque if the integrated value is 95%

Motor I2t Time [233] Sets the time of the I2t function. After this time the limit for the I2t is reached if operating with 120% of the I2t current value. Valid when start from 0 rpm. NOTE: Not the time constant of the motor. Communication information or closer to the limit, so that the limit cannot be exceeded. NOTE: If it is not possible to reduce the current, the AC drive will trip after exceeding 110% of the limit.

Axes t[s] with10,100,1000,10000,100000; Actual output current/I²t-current with1,1.1,1.2,1.3,1.4,1.5,1.6,1.7,1.8,1.9,2. Curves labeled60s(120%),120s(120%),240s(120%),480s(120%),1000s(120%). Thick example line at1.2 and1000s is explained on nextpage70. No interpolated curve values; original chart retained. Hidden native extra i/I²t-current fragment is not a second visible axis.

232 Mot I2t Curr Stp A 100%

233 Mot I2t Time Stp A M1: 60s

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

232 Motor I2t Current metadata — PDF page 69

Source row Property Source value
1 Default: 100% of IMOT
2 Range: 0–150% of IMOT

233 Motor I2t Time metadata — PDF page 69

Source row Property Source value
1 Default: 60 s
2 Range: 60–1200 s

232 communication — PDF page 69

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43062
2 Profibus slot/index 168/221
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

233 communication — PDF page 69

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43063
2 Profibus slot/index 168/222
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — PTC PT100 and insulation class settings — page 70

Manual reference: physical PDF page 70. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example In Fig. 63 the thick grey line shows the following exam- ple. • Menu [232] Mot I2t Curr is set to 100%. 1.2 x 100% = 120% • Menu [233] Mot I2t Time is set to 1000 s. This means that the AC drive will trip or reduce after 1000 s if the current is 1.2 times of 100% nominal motor current. Thermal Protection [234] Only visible if the PTC/PT100 option board is installed. Set the PTC input for thermal protection of the motor. The motor thermistors (PTC) must comply with DIN 44081/44082. Please refer to the manual for the PTC/ PT100 option board. Menu [234] PTC contains functions to enable or disa- ble the PTC input. Here you can select and activate PTC and/or PT100. Communication information NOTE: PTC option and PT100 selections can only be selected in menu [234] if the option board is mounted. NOTE: If you select the PTC option, the PT100 inputs are ignored. Motor Class [235] Only visible if the PTC/PT100 option board is installed. Set the class of motor used. The trip levels for the

PT100 sensor will automatically be set according to the setting in this menu. Communication information NOTE: This menu is only valid for PT 100.

235 Mot Class Stp A F 140°C

234 Thermal Prot Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

235 Motor Class metadata — PDF page 70

Source row Property Source value
1 Default: F 140°C

235 Motor Class selections — PDF page 70

Source row Selection Integer code Description
1 A 100°C 0 ⟦blank source cell⟧
2 E 115°C 1 ⟦blank source cell⟧
3 B 120°C 2 ⟦blank source cell⟧
4 F 140°C 3 ⟦blank source cell⟧
5 F Nema 145°C 4 ⟦blank source cell⟧
6 H 165°C 5 ⟦blank source cell⟧

235 communication — PDF page 70

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43065
2 Profibus slot/index 168/224
3 Fieldbus format UInt
4 Modbus format UInt

234 Thermal Protection metadata — PDF page 70

Source row Property Source value
1 Default: Off

234 Thermal Protection selections — PDF page 70

Source row Selection Integer code Description
1 Off 0 PTC and PT100 motor protection are disabled.
2 PTC 1 Enables the PTC protection of the motor via the insulated option board.
3 PT100 2 Enables the PT100 protection for the motor via the insulated option board.
4 PTC+PT100 3 Enables the PTC protection as well as the PT100 protection for the motor via the insulated option board.

234 communication — PDF page 70

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43064
2 Profibus slot/index 168/223
3 Fieldbus format UInt
4 Modbus format UInt

Manual — PT100 and internal PTC selection — page 71

Manual reference: physical PDF page 71. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

PT100 Inputs [236] Sets which of PT100 inputs that should be used for thermal protection. Deselecting not used PT100 inputs on the PTC/PT100 option board in order to ignore those inputs, i.e. extra external wiring is not needed if port is not used. Communication information NOTE: This menu is only valid for PT 100 thermal protection if PT100 is enabled in menu [234].

Motor PTC [237] In this menu the internal motor PTC hardware option is enabled. This PTC input complies with DIN 44081/ 44082. Please refer to the manual for the PTC/PT100 option board for electrical specification. This menu is only visible if a PTC (or resistor <2 kOhm) is connected to terminals X1: 78–79. To enable the function: 1. Connect the thermistor wires to X1: 78–79 or for testing the input, connect a resistor to the terminals. Use resistor value between 50 and 2000 ohm. Menu [237] will now appear. 2. Enable input by setting menu [237] Motor PTC=On. If enabled and <50 ohm a sensor error trip will occur. The message “Motor PTC” is shown. If the function is disabled and the PTC or resistor is removed, the menu will disappear after the next power up NOTE: This option is available only for (size B to D) JNVX48/52-0003-0074. Communication information

236 PT100 Inputs Stp A PT100 1+2+3

237 Motor PTC Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

236 PT100 Inputs metadata — PDF page 71

Source row Property Source value
1 Default: PT100 1+2+3
2 Selection: PT100 1, PT100 2, PT100 1+2, PT100 3, PT100 1+3, PT100 2+3, PT100 1+2+3

236 PT100 Inputs selections — PDF page 71

Source row Selection Integer code Description
1 PT100 1 1 Channel 1 used for PT100 protection
2 PT100 2 2 Channel 2 used for PT100 protection
3 PT100 1+2 3 Channel 1+2 used for PT100 protection
4 PT100 3 4 Channel 3 used for PT100 protection
5 PT100 1+3 5 Channel 1+3 used for PT100 protection
6 PT100 2+3 6 Channel 2+3 used for PT100 protection
7 PT100 1+2+3 7 Channel 1+2+3 used for PT100 protec- tion

237 Motor PTC metadata — PDF page 71

Source row Property Source value
1 Default: Off

237 Motor PTC selections — PDF page 71

Source row Selection Integer code Description
1 Off 0 Motor PTC protection is disabled
2 On 1 Motor PTC protection is enabled

236 communication — PDF page 71

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43066
2 Profibus slot/index 168/225
3 Fieldbus format UInt
4 Modbus format UInt

237 communication — PDF page 71

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43067
2 Profibus slot/index 168/226
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Parameter set selection and copying — page 72

Manual reference: physical PDF page 72. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.2.6 Parameter Set Handling [240] There are four different parameter sets available in the AC drive. These parameter sets can be used to set the AC drive up for different processes or applications such as different motors used and connected, activated PID controller, different ramp time settings, etc. A parameter set consists of all parameters with the exception of the Global parameters . The Global param- eters are only able to have one value for all parameter sets. Following parameters are Global: [211] Language, [217] Local Remote, [218] Lock Code, [220] Motor Data, [241] Select Set, [260] Serial Communication and [21B]Mains Supply Voltage . NOTE: Actual timers are common for all sets. When a set is changed the timer functionality will change according to the new set, but the timer value will stay unchanged. Select Set [241] Here you select the parameter set. Every menu included in the parameter sets is designated A, B, C or D depending on the active parameter set. Parameter sets can be selected from the keyboard, via the pro- grammable digital inputs or via serial communication. Parameter sets can be changed during the run. If the sets are using different motors (M1 to M4) the set will be changed when the motor is stopped. Communication information

The active set can be viewed with function [721] FI sta- tus. NOTE: Parameter set cannot be changed during run if this also would imply a change of the motor set (M2- M4). Copy Set [242] This function copies the content of a parameter set into another parameter set. Communication information NOTE: The actual value of menu [310] will not be copied into the other set. A>B means that the content of parameter set A is cop- ied into parameter set B.

242 Copy Set Stp A A>B

241 Select Set Stp A A

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

242 Copy Set metadata — PDF page 72

Source row Property Source value
1 Default: A>B

242 Copy Set selections — PDF page 72

Source row Selection Integer code Description
1 A>B 0 Copy set A to set B
2 A>C 1 Copy set A to set C
3 A>D 2 Copy set A to set D
4 B>A 3 Copy set B to set A
5 B>C 4 Copy set B to set C
6 B>D 5 Copy set B to set D
7 C>A 6 Copy set C to set A
8 C>B 7 Copy set C to set B
9 C>D 8 Copy set C to set D
10 D>A 9 Copy set D to set A
11 D>B 10 Copy set D to set B
12 D>C 11 Copy set D to set C

241 Select Set metadata — PDF page 72

Source row Property Source value
1 Default: A
2 Selection: A, B, C, D, DigIn, Com, Option

241 Select Set selections — PDF page 72

Source row Selection Integer code Description
1 A 0 Fixed selection of one of the 4 parameter sets A, B, C or D.
2 B 1 Fixed selection of one of the 4 parameter sets A, B, C or D.
3 C 2 Fixed selection of one of the 4 parameter sets A, B, C or D.
4 D 3 Fixed selection of one of the 4 parameter sets A, B, C or D.
5 DigIn 4 Parameter set is selected via a digital input. Define which digital input in menu [520], Digital inputs.
6 Com 5 Parameter set is selected via serial communication.
7 Option 6 The parameter set is set via an option. Only available if the option can control the selection.

242 communication — PDF page 72

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43021
2 Profibus slot/index 168/180
3 Fieldbus format UInt
4 Modbus format UInt

241 communication — PDF page 72

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43022
2 Profibus slot/index 168/181
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Load defaults and copy to panel — page 73

Manual reference: physical PDF page 73. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Load Default Values Into Set [243] With this function three different levels (factory set- tings) can be selected for the four parameter sets. When loading the default settings, all changes made in the software are set to factory settings. This function also includes selections for loading default settings to the four different Motor Data Sets. Communication information NOTE: Trip log hour counter and other VIEW ONLY menus are not regarded as settings and will be unaffected. NOTE: If “Factory” is selected, the message “Sure?” is displayed. Press the + key to display “Yes” and then Enter to confirm. NOTE: The parameters in menu [220], Motor data, are not affected by loading defaults when restoring parameter sets A–D.

Copy All Settings to Control Panel [244] All the settings can be copied into the control panel including the motor data. Start commands will be ignored during copying. Communication information NOTE: The actual value of menu [310] will not be copied into control panel memory set.

244 Copy to CP Stp A No Copy; [padlock symbol: cannot change during Run Mode]

243 Default>Set Stp A A

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

244 Copy All to Control Panel metadata — PDF page 73

Source row Property Source value
1 Default: No Copy

244 Copy All to Control Panel selections — PDF page 73

Source row Selection Integer code Description
1 No Copy 0 Nothing will be copied
2 Copy 1 Copy all settings

243 Load Defaults metadata — PDF page 73

Source row Property Source value
1 Default: A

243 Load Defaults selections — PDF page 73

Source row Selection Integer code Description
1 A 0 Only the selected parameter set will revert to its default settings.
2 B 1 Only the selected parameter set will revert to its default settings.
3 C 2 Only the selected parameter set will revert to its default settings.
4 D 3 Only the selected parameter set will revert to its default settings.
5 ABCD 4 All four parameter sets will revert to the default settings.
6 Factory 5 All settings, except [211], [221]-[22D], [261], [3A1] and [923], will revert to the default settings.
7 M1 6 Only the selected motor set will revert to its default settings.
8 M2 7 Only the selected motor set will revert to its default settings.
9 M3 8 Only the selected motor set will revert to its default settings.
10 M4 9 Only the selected motor set will revert to its default settings.
11 M1234 10 All four motor sets will revert to default settings.

244 communication — PDF page 73

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43024
2 Profibus slot/index 168/183
3 Fieldbus format UInt
4 Modbus format UInt

243 communication — PDF page 73

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43023
2 Profibus slot/index 168/182
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Load from panel and autoreset — page 74

Manual reference: physical PDF page 74. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Load Settings from Control Panel [245] This function can load all four parameter sets from the control panel to the AC drive. Parameter sets from the source AC drive are copied to all parameter sets in the target AC drive, i.e. A to A, B to B, C to C and D to D. Start commands will be ignored during loading. Communication information NOTE: Loading from the control panel will not affect the value in menu [310].

11.2.7 Trip Autoreset/Trip Conditions [250] The benefit of this feature is that occasional trips that do not affect the process will be automatically reset. Only when the failure keeps on coming back, recurring at defined times and therefore cannot be solved by the AC drive, will the unit give an alarm to inform the opera- tor that attention is required. For all trip functions that can be activated by the user you can select to control the motor down to zero speed according to set deceleration ramp to avoid water ham- mer. Also see section 12.2, page 170. Autoreset example: In an application it is known that the main supply volt- age sometimes disappears for a very short time, a so- called “dip”. That will cause the AC drive to trip an “Und- ervoltage alarm”. Using the Autoreset function, this trip will be acknowledged automatically. • Enable the Autoreset function by making the reset input continuously high. • Activate the Autoreset function in the menu [251], Number of trips. • Select in menus [252] to [25N] the Trip condition that are allowed to be automatically reset by the Autoreset function after the set delay time has expired. Number of Trips [251] Any number set above 0 activates the Autoreset. This means that after a trip, the AC drive will restart auto- matically according to the number of attempts selected. No restart attempts will take place unless all conditions are normal. If the Autoreset counter (not visible) contains more trips than the selected number of attempts, the Autoreset cycle will be interrupted. No Autoreset will then take place. If there are no trips for more than 10 minutes, the Autoreset counter decreases by one. If the maximum number of trips has been reached, the trip message hour counter is marked with an “A”. If the Autoreset is full then the AC drive must be reset by a normal Reset.

245 Load from CP Stp A No Copy; [padlock symbol: cannot change during Run Mode]

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

245 Load from Control Panel metadata — PDF page 74

Source row Property Source value
1 Default: No Copy

245 Load from Control Panel selections — PDF page 74

Source row Selection Integer code Description
1 No Copy 0 Nothing will be loaded.
2 A 1 Data from parameter set A is loaded.
3 B 2 Data from parameter set B is loaded.
4 C 3 Data from parameter set C is loaded.
5 D 4 Data from parameter set D is loaded.
6 ABCD 5 Data from parameter sets A, B, C and D are loaded.
7 A+Mot 6 Parameter set A and Motor data are loaded.
8 B+Mot 7 Parameter set B and Motor data are loaded.
9 C+Mot 8 Parameter set C and Motor data are loaded.
10 D+Mot 9 Parameter set D and Motor data are loaded.
11 ABCD+Mot 10 Parameter sets A, B, C, D and Motor data are loaded.
12 M1 11 Data from motor 1 is loaded.
13 M2 12 Data from motor 2 is loaded.
14 M3 13 Data from motor 3 is loaded.
15 M4 14 Data from motor 4 is loaded.
16 M1M2M3 M4 15 Data from motor 1, 2, 3 and 4 are loaded.
17 All 16 All data is loaded from the control panel.

245 communication — PDF page 74

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43025
2 Profibus slot/index 168/184
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Autoreset attempts and thermal delays — page 75

Manual reference: physical PDF page 75. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example: • Autoreset = 5 • Within 10 minutes 6 trips occur • At the 6th trip there is no Autoreset, because the Autoreset trip log contains 5 trips already. • To reset, apply a normal reset: set the reset input high to low and high again to maintain the Autoreset function. The counter is reset. Communication information NOTE: An auto reset is delayed by the remaining ramp time. Over temperature [252] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information NOTE: An auto reset is delayed by the remaining ramp time.

Overvolt D [253] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information NOTE: An auto reset is delayed by the remaining ramp time. Overvolt G [254] Delay time starts counting when the fault is gone When the time delay has elapsed, the alarm will be reset if the function is active. Communication information

253 Overvolt D Stp A Off

251 No of Trips Stp A 0

254 Overvolt G Stp A Off

252 Overtemp Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

253 Overvolt D metadata — PDF page 75

Source row Property Source value
1 Default: Off

253 Overvolt D selections — PDF page 75

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

251 Number of Trips metadata — PDF page 75

Source row Property Source value
1 Default: 0 (no Autoreset)
2 Range: 0–10 attempts

253 communication — PDF page 75

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43075
2 Profibus slot/index 168/234
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

251 communication — PDF page 75

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43071
2 Profibus slot/index 168/230
3 Fieldbus format UInt
4 Modbus format UInt

254 communication — PDF page 75

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43076
2 Profibus slot/index 168/235
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

252 communication — PDF page 75

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43072
2 Profibus slot/index 168/231
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — Overvoltage motor loss and I2t delays — page 76

Manual reference: physical PDF page 76. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Overvolt [255] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Motor Lost [256] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. NOTE: Only visible when Motor Lost is selected in menu [423]. Communication information

Locked Rotor [257] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Power Fault [258] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Undervoltage [259] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active.

255 Overvolt Stp A Off

257 Locked Rotor Stp A Off

256 Motor Lost Stp A Off

258 Power Fault Stp A Off

259 Undervoltage Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

255 Overvoltage metadata — PDF page 76

Source row Property Source value
1 Default: Off

255 Overvoltage selections — PDF page 76

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

255 communication — PDF page 76

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43077
2 Profibus slot/index 168/236
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

257 communication — PDF page 76

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43086
2 Profibus slot/index 168/245
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

258 communication — PDF page 76

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43087
2 Profibus slot/index 168/246
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

256 communication — PDF page 76

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43083
2 Profibus slot/index 168/242
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — Undervoltage and PTC PT100 reset settings — page 77

Manual reference: physical PDF page 77. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Motor I2t [25A] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Motor I2t Trip Type [25B] Select the preferred way to react to a Motor I2t trip. Communication information PT100 [25C] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active

. Communication information PT100 Trip Type [25D] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information PTC [25E] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information

25C PT100 Stp A Off

25A Motor I2t Stp A Off

25D PT100 TT Stp A Trip

25B Motor I2t TT Stp A Trip

25E PTC Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

259 communication continuation from PDF76 — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43088
2 Profibus slot/index 168/247
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25C PT100 metadata — PDF page 77

Source row Property Source value
1 Default: Off

25C PT100 selections — PDF page 77

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

25C communication — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43078
2 Profibus slot/index 168/237
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25A communication — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43073
2 Profibus slot/index 168/232
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25D PT100 Trip Type metadata — PDF page 77

Source row Property Source value
1 Default: Trip
2 Selection: Same as menu [25B]

25D communication — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43079
2 Profibus slot/index 168/238
3 Fieldbus format Uint
4 Modbus format UInt

25B Motor I2t Trip Type metadata — PDF page 77

Source row Property Source value
1 Default: Trip

25B Motor I2t Trip Type selections — PDF page 77

Source row Selection Integer code Description
1 Trip 0 The motor will trip
2 Deceleration 1 The motor will decelerate

25B communication — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43074
2 Profibus slot/index 168/233
3 Fieldbus format UInt
4 Modbus format UInt

25E communication — PDF page 77

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43084
2 Profibus slot/index 168/243
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — External and communication reset modes — page 78

Manual reference: physical PDF page 78. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

PTC Trip Type [25F] Select the preferred way to react to a PTC trip. Communication information External Trip [25G] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information

External Trip Type [25H] Select the preferred way to react to an alarm trip. Communication information Communication Error [25I] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information

25F PTC TT Stp A Trip

25H Ext Trip TT Stp A Trip

25G Ext Trip Stp A Off

25I Com Error Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

25F PTC Trip Type metadata — PDF page 78

Source row Property Source value
1 Default: Trip
2 Selection: Same as menu [25B]

25F communication — PDF page 78

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43085
2 Profibus slot/index 168/244
3 Fieldbus format UInt
4 Modbus format UInt

25H communication — PDF page 78

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43081
2 Profibus slot/index 168/240
3 Fieldbus format UInt
4 Modbus format UInt

25G External Trip metadata — PDF page 78

Source row Property Source value
1 Default: Off

25G External Trip selections — PDF page 78

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

25G communication — PDF page 78

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43080
2 Profibus slot/index 168/239
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25I communication — PDF page 78

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43089
2 Profibus slot/index 168/248
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — Minimum maximum and overcurrent reset — page 79

Manual reference: physical PDF page 79. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication Error Trip Type [25J] Select the preferred way to react to a communication trip. Communication information Min Alarm [25K] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Min Alarm Trip Type [25L] Select the preferred way to react to a min alarm trip. Communication information

Max Alarm [25M] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information Max Alarm Trip Type [25N] Select the preferred way to react to a max alarm trip. Communication information Over current F [25O] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active.

25J Com Error TT Stp A Trip

25M Max Alarm Stp A Off

25K Min Alarm Stp A Off

25N Max Alarm TT Stp A Trip

25L Min Alarm TT Stp A Trip

25O Over curr F Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

25J Communication Error Trip Type metadata — PDF page 79

Source row Property Source value
1 Default: Trip
2 Selection: Same as menu [25B]

25M Max Alarm metadata — PDF page 79

Source row Property Source value
1 Default: Off

25M Max Alarm selections — PDF page 79

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

25J communication — PDF page 79

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43090
2 Profibus slot/index 168/249
3 Fieldbus format UInt
4 Modbus format UInt

25M communication — PDF page 79

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43093
2 Profibus slot/index 168/252
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25N communication — PDF page 79

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43094
2 Profibus slot/index 168/253
3 Fieldbus format UInt
4 Modbus format UInt

25K communication — PDF page 79

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43091
2 Profibus slot/index 168/250
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25L communication — PDF page 79

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43092
2 Profibus slot/index 168/251
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Overcurrent overspeed and external motor reset — page 80

Manual reference: physical PDF page 80. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Over Speed [25Q] Delay time starts counting when the fault is gone. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information External Motor Temperature [25R] Delay time starts counting when the fault disappears. When the time delay has elapsed, the alarm will be reset if the function is active. Communication information

External Motor Trip Type [25S] Select the preferred way to react to an alarm trip. Communication information Liquid cooling low level [25T] Delay time starts counting when the fault disappears. When the time delay has elapsed, the alarm will be reset if the function is active.

25S Ext Mot TT Stp A Trip

25Q Over speed Stp A Off

25T LC Level Stp A Off

25R Ext Mot Temp Stp A Off

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

25O communication continuation from PDF79 — PDF page 80

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43082
2 Profibus slot/index 168/241
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25S External Motor Trip Type metadata — PDF page 80

Source row Property Source value
1 Default: Trip
2 Selection: Same as menu [25B]

25S communication — PDF page 80

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43098
2 Profibus slot/index 168/240
3 Fieldbus format UInt
4 Modbus format UInt

25Q Overspeed metadata — PDF page 80

Source row Property Source value
1 Default: Off

25Q Overspeed selections — PDF page 80

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

25Q communication — PDF page 80

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43096
2 Profibus slot/index 169/0
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25R communication — PDF page 80

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43097
2 Profibus slot/index 168/239
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — Cooling brake reset and serial interface — page 81

Manual reference: physical PDF page 81. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Liquid Cooling Low level Trip Type [25U] Select the preferred way to react to an alarm trip. Communication information Brake Fault [25V] Select the preferred way to react to an alarm trip, acti- vate auto reset and specify delay time. Communication information

11.2.8 Serial Communication [260] This function is to define the communication parame- ters for serial communication. There are two types of options available for serial communication, RS232/ 485 (Modbus/RTU) and fieldbus modules (Profibus, DeviceNet and Ethernet). For more information see chapter Serial communica- tion and respective option manual. Comm Type [261] Select RS232/485 [262] or Fieldbus [263]. NOTE: Toggling the setting in this menu will perform a soft reset (re-boot) of the Fieldbus module. RS232/485 [262] Press Enter to set up the parameters for RS232/485 (Modbus/RTU) communication. Baud rate [2621] Set the baud rate for the communication. NOTE: This baud rate is only used for the isolated RS232/485 option.

262 RS232/485 /Stp. No displayed value; blank preserved.

25U LC Level TT Stp A Trip

261 Com Type Stp A RS232/485; [padlock symbol: cannot change during Run Mode]

25V Brk Fault Stp A Off

2621 Baudrate Stp A 9600

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

25T communication continuation from PDF80 — PDF page 81

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43099
2 Profibus slot/index 169/3
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

25U Liquid Cooling Low Level Trip Type metadata — PDF page 81

Source row Property Source value
1 Default: Trip
2 Selection: Same as menu [25B]

261 Communication Type metadata — PDF page 81

Source row Property Source value
1 Default: RS232/485

261 Communication Type selections — PDF page 81

Source row Selection Integer code Description
1 RS232/485 0 RS232/485 selected
2 Fieldbus 1 Fieldbus selected (Profibus, DeviceNet or Modbus/TCP)

25U communication — PDF page 81

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43100
2 Profibus slot/index 169/4
3 Fieldbus format UInt
4 Modbus format UInt

25V Brake Fault metadata — PDF page 81

Source row Property Source value
1 Default Off

25V Brake Fault selections — PDF page 81

Source row Selection Integer code Description
1 Off 0 Autoreset not activated.
2 1 - 3600s 1 - 3600s Brake fault auto reset delay time.

2621 Baud Rate metadata — PDF page 81

Source row Property Source value
1 Default: 9600

2621 Baud Rate selections — PDF page 81

Source row Selection Integer code Description
1 2400 0 Selected baud rate
2 4800 1 Selected baud rate
3 9600 2 Selected baud rate
4 19200 3 Selected baud rate
5 38400 4 Selected baud rate

25V communication — PDF page 81

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43070
2 Profibus slot/index 168/229
3 Fieldbus format Long, 1=1s
4 Modbus format EInt

Manual — Serial and fieldbus configuration — page 82

Manual reference: physical PDF page 82. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Address [2622] Enter the unit address for the AC drive. NOTE: This address is only used for the isolated RS232/ 485 option. Fieldbus [263] Press Enter to set up the parameters for fieldbus communication. Address [2631] Enter the unit address of the AC drive. Process Data Mode [2632] Enter the mode of process data (cyclic data). For fur- ther information, see the Fieldbus option manual.

Read/Write [2633] Select read/write to control the inverter over a fieldbus network. For further information, see the Fieldbus option manual. Additional Process Values [2634] Define the number of additional process values sent in cyclic messages.

263 Fieldbus /Stp A. Blank value preserved.

2633 Read/Write Stp A RW

2622 Address Stp A 1

2634 AddPrValues Stp A 0

2631 Address Stp A 62

2632 PrData Mode Stp A Basic

Valid for process data. Select R (read only) for logging process without writing process data. Select RW in normal cases to control inverter.

Node address valid for Profibus and DeviceNet

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

2633 Read Write metadata — PDF page 82

Source row Property Source value
1 Default: RW

2633 Read Write selections — PDF page 82

Source row Selection Integer code Description
1 RW 0 ⟦blank source cell⟧
2 Read 1 ⟦blank source cell⟧

2622 RS232 485 Address metadata — PDF page 82

Source row Property Source value
1 Default: 1
2 Selection: 1–247

2634 Additional Process Values metadata — PDF page 82

Source row Property Source value
1 Default: 0
2 Range: 0-8

2631 Fieldbus Address metadata — PDF page 82

Source row Property Source value
1 Default: 62
2 Range: Profibus 0–126, DeviceNet 0–63

2632 Process Data Mode metadata — PDF page 82

Source row Property Source value
1 Default: Basic

2632 Process Data Mode selections — PDF page 82

Source row Selection Integer code Description
1 None 0 Control/status information is not used.
2 Basic 4 4 byte process data control/status information is used.
3 Extended 8 4 byte process data (same as Basic setting) + additional proprietary protocol for advanced users is used.

Manual — Communication fault and Ethernet settings — page 83

Manual reference: physical PDF page 83. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication Fault [264] Main menu for communication fault/warning settings. For further details please see the Fieldbus option man- ual. Communication Fault Mode [2641]] Selects action if a communication fault is detected. NOTE: Menu [214] and/or [215] must be set to COM to activate the communication fault function. Communication information

Communication Fault Time [2642]] Defines the delay time for the trip/warning. Communication information Ethernet [265] Settings for Ethernet module (Modbus/TCP). For further information, see the Fieldbus option manual. NOTE: The Ethernet module must be re-booted to activate the below settings. For example by toggling parameter [261]. Non-initialized settings indicated by flashing display text. IP Address [2651] MAC Address [2652] Subnet Mask [2653]

2642 ComFlt Time Stp A 0.5s

2641 ComFlt Mode Stp A Off

2651 IP Address /0.0.0.0 (visible display illustration; hidden native zeros retained raw only)

2652 MAC Address Stp A 000000000000

2653 Subnet Mask /0.0.0.0 (visible display illustration; hidden native zeros retained raw only)

Source menu specification, not motor performance rating. Symbolic defaults retained. Integer selection codes are not communication addresses. Read all same-page notes and cross-page continuations. Display examples separate from defaults. Shared descriptions only repeat within physical merged extent.

2642 Communication Fault Time metadata — PDF page 83

Source row Property Source value
1 Default: 0.5 s
2 Range: 0.1-15 s

2641 Communication Fault Mode metadata — PDF page 83

Source row Property Source value
1 Default: Off

2641 Communication Fault Mode selections — PDF page 83

Source row Selection Integer code Description
1 Off 0 No communication supervision.
2 Trip 1 RS232/485 selected: The AC drive will trip if there is no communication for time set in parameter [2642]. Fieldbus selected: The AC drive will trip if: 1. The internal communication between the control board and fieldbus option is lost for time set in parameter [2642]. 2. If a serious network error has occurred.
3 Warning 2 RS232/485 selected: The AC drive will give a warning if there is no communication for time set in parameter [2642]. Fieldbus selected: The AC drive will give a warning if: 1. The internal communication between the control board and fieldbus option is lost for time set in parameter [2642]. 2. If a serious network error has occurred.

2642 communication — PDF page 83

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43038
2 Profibus slot/index 168/197
3 Fieldbus format Long, 1=0.1 s
4 Modbus format EInt

2651 IP Address metadata — PDF page 83

Source row Property Source value
1 Default: 0.0.0.0

2652 MAC Address metadata — PDF page 83

Source row Property Source value
1 Default: An unique number for the Ethernet module.

2641 communication — PDF page 83

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43037
2 Profibus slot/index 168/196
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Ethernet fieldbus mapping and reference display — page 84

Manual reference: physical PDF page 84. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Gateway [2654] DHCP [2655] Fieldbus Signals [266] Defines modbus mapping for additional process values. For further information, see the Fieldbus option man- ual. FB Signal 1 - 16 [2661]-[266G] Used to create a block of parameters which are read/ written via communication. 1 to 8 read + 1 to 8 write parameters possible. Communication information FB Status [269] Sub menus showing status of fieldbus parameters. Please see the Fieldbus manual for detailed informa- tion.

11.3 Process and Application Parameters [300] These parameters are mainly adjusted to obtain opti- mum process or machine performance. The read-out, references and actual values depends on selected process source, [321}: Table 23 11.3.1 Set/View Reference Value [310] View reference value As default the menu [310] is in view operation. The value of the active reference signal is displayed. The value is displayed according to selected process source, [321] or the process unit selected in menu [322]. Set reference value If the function Reference Control [214] is set to “Keyboard”, the reference value can be set in menu Set/View Reference [310] or as a motor potentiometer with the + and - keys (default) on the control panel. Selection is made with parameter Keyboard Reference Mode in menu [369]. The ramp times used when set- ting the reference value with MotPot function selected in [369] are according to menus Acc MotPot [333] and Dec MotPot [334]. The ramp times used for the reference value when Nor- mal function is selected in menu [369], are according to Acc Time [331] and Dec Time [332]. Menu [310] displays on-line the actual reference value according to the Mode Settings in Table 23.

269 FB Status /Stp; value blank.

2654 Gateway /0.0.0.0 (visible display illustration; hidden native zero groups retained raw only)

2655 DHCP Stp A Off

2661 FB Signal 1 Stp A 0

310 Set/View ref Stp 0rpm

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

2654 Gateway metadata — PDF page 84

Source row Property or applicable mode Source value
1 Default: 0.0.0.0

2655 DHCP metadata — PDF page 84

Source row Property or applicable mode Source value
1 Default: Off
2 Selection: On/Off

Table23 process source units and resolution — PDF page 84

Source row Selected process source Unit for reference and actual value Resolution
1 Speed rpm 4 digits
2 Torque % 3 digits
3 PT100 °C 3 digits
4 Frequency Hz 3 digits

2661–266G Fieldbus Signals 1–16 metadata — PDF page 84

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0-65535

2661–266G communication — PDF page 84

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42801-42816
2 Profibus slot/index 167/215-167/230
3 Fieldbus format UInt
4 Modbus format UInt

310 Set View Reference metadata — PDF page 84

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Dependent on: Process Source [321] and Process Unit [322]
3 Speed mode 0 - max speed [343]
4 Torque mode 0 - max torque [351]
5 Other modes Min according to menu [324] - max accord- ing to menu [325]

Manual — Reference restrictions and process source — page 85

Manual reference: physical PDF page 85. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information NOTE: The actual value in menu [310] is not copied, or loaded from the control panel memory when Copy Set [242], Copy to CP [244] or Load from CP [245] is performed. NOTE: If the MotPot function is used, the reference value ramp times are according to the Acc MotPot [333] and Dec MotPot [334] settings. Actual speed ramp will be limited according to Acc Time [331] and Dec Time [332]. NOTE: Write access to this parameter is only allowed when menu “Ref Control [214] is set to Keyboard. When Reference control is used, see section “10.5 Reference signal” on page 60

11.3.2 Process Settings [320] With these functions, the AC drive can be set up to fit the application. The menus [110], [120], [310], [362]- [368] and [711] use the process unit selected in [321] and [322] for the application, e.g. rpm, bar or m3/h. This makes it possible to easily set up the AC drive for the required process requirements, as well as for copy- ing the range of a feedback sensor to set up the Proc- ess Value Minimum and Maximum in order to establish accurate actual process information. Process Source [321] Select the signal source for the process value that con- trols the motor. The Process Source can be set to act as a function of the process signal on AnIn F(AnIn), a func- tion of the motor speed F(Speed), a function of the shaft torque F(Torque) or as a function of a process value from serial communication F(Bus). The right func- tion to select depends on the characteristics and behaviour of the process. If the selection Speed, Torque or Frequency is set, the AC drive will use speed, torque or frequency as reference value. Example An axial fan is speed-controlled and there is no feed- back signal available. The process needs to be control- led within fixed process values in “m3/hr” and a process read-out of the air flow is needed. The charac- teristic of this fan is that the air flow is linearly related to the actual speed. So by selecting F(Speed) as the Process Source, the process can easily be controlled. The selection F(xx) indicates that a process unit and scaling is needed, set in menus [322]-[328]. This makes it possible to e.g. use pressure sensors to meas- ure flow etc. If F(AnIn) is selected, the source is auto- matically connected to the AnIn which has Process Value as selected.

321 Proc Source Stp A Speed

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

310 communication continuation from PDF84 — PDF page 85

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42991
2 Profibus slot/index 168/150
3 Fieldbus format Long
4 Modbus format EInt

321 Process Source metadata — PDF page 85

Source row Property or applicable mode Source value
1 Default: Speed

321 Process Source selections — PDF page 85

Source row Selection Integer code Description
1 F(AnIn) 0 Function of analogue input. E.g. via PID control, [330].
2 Speed 1 Speed as process reference1.
3 Torque 2 Torque as process reference2.
4 PT100 3 Temperature as process reference.
5 F(Speed) 4 Function of speed
6 F(Torque) 5 Function of torque2
7 F(Bus) 6 Function of communication reference
8 Frequency 7 Frequency as process reference1.

Manual — Process source conditions and units — page 86

Manual reference: physical PDF page 86. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Only when Drive mode [213] is set to Speed or V/ Hz.2. Only when Drive mode [213] is set to Torque. NOTE: When PT100 is selected, use PT100 channel 1 on the PTC/PT100 option board. NOTE: If Speed, Torque or Frequency is chosen in menu [321] Proc Source, menus [322] - [328] are hidden. NOTE: The motor control method depends on the selection of drive mode [213], regardless of selected process source, [321]. NOTE: If F (Bus) is chosen in menu [321]see section 10.5.1 Process value. Communication information Process Unit [322] Communication information

NOTE: In case of conflicting setup between this Process Source, [321], selection and drive mode [213] the software will automatically overrule the selection in menu [321] according to the following: [213]=Torque and [321]=Speed; internally [321]=Torque will be used. [213]=Speed or V/Hz and [321]=Torque; internally [321]=Speed will be used.

322 Proc Unit Stp A rpm

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

m3/h

ft3/h

321 communication continuation from PDF85 — PDF page 86

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43302
2 Profibus slot/index 169/206
3 Fieldbus format UInt
4 Modbus format UInt

322 Process Unit metadata — PDF page 86

Source row Property or applicable mode Source value
1 Default: rpm

322 Process Unit selections — PDF page 86

Source row Selection Integer code Description
1 Off 0 No unit selection
2 % 1 Percent
3 °C 2 Degrees Centigrade
4 °F 3 Degrees Fahrenheit
5 bar 4 bar
6 Pa 5 Pascal
7 Nm 6 Torque
8 Hz 7 Frequency
9 rpm 8 Revolutions per minute
10 m³/h 9 Cubic meters per hour
11 gal/h 10 Gallons per hour
12 ft³/h 11 Cubic feet per hour
13 User 12 User defined unit

322 communication — PDF page 86

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43303
2 Profibus slot/index 169/207
3 Fieldbus format UInt
4 Modbus format UInt

Manual — User-defined unit character codes — page 87

Manual reference: physical PDF page 87. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

User-defined Unit [323] This menu is only displayed if User is selected in menu [322]. The function enables the user to define a unit with six symbols. Use the Prev and Next key to move the cursor to required position. Then use the + and - keys to scroll down the character list. Confirm the character by moving the cursor to the next position by pressing the Next key.

Example: Create a user unit named kPa. 1. When in the menu [323] press Next to move the cur- sor to the right most position. 2. Press the + key until the character k is displayed. 3. Press Next. 4. Then press the + key until P is displayed and con- firm with Next. 5. Repeat until you have entered kPa. Communication information When sending a unit name you send one character at a time starting at the right most position.

323 User Unit StpA

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

323 character codes continuation — PDF page 87

Source row Character left Serial code left Character right Serial code right
1 ê 48 = 97
2 ë 49 > 98
3 f 50 ? 99
4 g 51 @ 100
5 h 52 ^ 101
6 i 53 _ 102
7 í 54 ° 103
8 j 55 ² 104
9 k 56 ³ 105
10 l 57 ⟦blank source cell⟧ ⟦blank source cell⟧

323 character codes — PDF page 87

Source row Character left Serial code left Character right Serial code right
1 Space 0 m 58
2 0–9 1–10 n 59
3 A 11 ñ 60
4 B 12 o 61
5 C 13 ó 62
6 D 14 ô 63
7 E 15 p 64
8 F 16 q 65
9 G 17 r 66
10 H 18 s 67
11 I 19 t 68
12 J 20 u 69
13 K 21 ü 70
14 L 22 v 71
15 M 23 w 72
16 N 24 x 73
17 O 25 y 74
18 P 26 z 75
19 Q 27 å 76
20 R 28 ä 77
21 S 29 ö 78
22 T 30 ! 79
23 U 31 ¨ 80
24 Ü 32 # 81
25 V 33 $ 82
26 W 34 % 83
27 X 35 & 84
28 Y 36 · 85
29 Z 37 ( 86
30 Å 38 ) 87
31 Ä 39 * 88
32 Ö 40 + 89
33 a 41 , 90
34 á 42 - 91
35 b 43 . 92
36 c 44 / 93
37 d 45 : 94
38 e 46 ; 95
39 é 47 < 96

323 User Unit metadata — PDF page 87

Source row Property or applicable mode Source value
1 Default: No characters shown

323 six character positions communication — PDF page 87

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43304 43305 43306 43307 43308 43309
2 Profibus slot/index 169/208 169/209 169/210 169/211 169/212 169/213
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Process min max and ratio scaling — page 88

Manual reference: physical PDF page 88. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Process Min [324] This function sets the minimum process value allowed. Communication information Process Max [325] This menu is not visible when speed, torque or fre- quency is selected. The function sets the value of the maximum process value allowed. Communication information Ratio [326] This menu is not visible when speed, frequency or torque is selected. The function sets the ratio between the actual process value and the motor speed so that it has an accurate process value when no feedback sig- nal is used. See Fig. 64.

Communication information Fig. 64 Ratio F(Value), Process Min [327] This function is used for scaling if no sensor is used. It offers you the possibility of increasing the process accuracy by scaling the process values. The process values are scaled by linking them to known data in the AC drive. With F(Value), Proc Min [327] the precise value at which the entered Process Min [324] is valid can be entered. NOTE: If Speed, Torque or Frequency is chosen in menu [321] Proc Source, menus [322]- [328] are hidden. Communication information

Vertical Process unit: Process Min[324], Process Max[325]. Horizontal Speed: Min Speed[341], Max Speed[343]. Curves labelled Ratio=Linear and Ratio=Quadratic; original geometry authoritative.

324 Process Min Stp A 0

325 Process Max Stp A 0

327 F(Val) PrMin Stp A Min

326 Ratio Stp A Linear

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

326 Ratio communication from lower left column — PDF page 88

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43312
2 Profibus slot/index 169/216
3 Fieldbus format UInt
4 Modbus format UInt

324 Process Min metadata — PDF page 88

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0.000-10000 (Speed, Torque, F(Speed), F(Torque)) -10000– +10000 (F(AnIn, PT100, F(Bus))

324 communication — PDF page 88

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43310
2 Profibus slot/index 169/214
3 Fieldbus format Long, 1=0.001
4 Modbus format EInt

325 Process Max metadata — PDF page 88

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0.000-10000

325 communication — PDF page 88

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43311
2 Profibus slot/index 169/215
3 Fieldbus format Long, 1=0.001
4 Modbus format EInt

327 F Value Process Min metadata — PDF page 88

Source row Property or applicable mode Source value
1 Default: Min

327 F Value Process Min selections — PDF page 88

Source row Selection Integer code Description
1 Min -1 According to Min Speed setting in [341].
2 Max -2 According to Max Speed setting in [343].
3 0.000-10000 0-10000 0.000-10000

326 Ratio metadata — PDF page 88

Source row Property or applicable mode Source value
1 Default: Linear

326 Ratio selections — PDF page 88

Source row Selection Integer code Description
1 Linear 0 Process is linear related to speed/torque
2 Quadratic 1 Process is quadratic related to speed/ torque

327 communication — PDF page 88

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43313
2 Profibus slot/index 169/217
3 Fieldbus format Long, 1=1 rpm
4 Modbus format EInt

Manual — Process maximum example and acceleration — page 89

Manual reference: physical PDF page 89. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

F(Value), Process Max [328] This function is used for scaling if no sensor is used. It offers you the possibility of increasing the process accuracy by scaling the process values. The process values are scaled by linking them to known data in the AC drive. With F(Value), Proc Max the precise value at which the entered Process Max [525] is valid can be entered. NOTE: If Speed, Torque or Frequency is chosen in menu [321] Proc Source, menus [322]- [328] are hidden. Communication information Example A conveyor belt is used to transport bottles. The required bottle speed needs to be within 10 to 100 bot- tles/s. Process characteristics: 10 bottles/s = 150 rpm 100 bottles/s = 1500 rpm The amount of bottles is linearly related to the speed of the conveyor belt. Set-up: Process Min [324] = 10 Process Max [325] = 100 Ratio [326] = linear F(Value), ProcMin [327] = 150 F(Value), ProcMax [328] = 1500 With this set-up, the process data is scaled and linked to known values which results in an accurate control.

Fig. 65 11.3.3 Start/Stop settings [330] Submenu with all the functions for acceleration, deceleration, starting, stopping, etc. Acceleration Time [331] The acceleration time is defined as the time it takes for the motor to accelerate from 0 rpm to nominal motor speed. NOTE: If the Acc Time is too short, the motor is accelerated according to the Torque Limit. The actual Acceleration Time may then be longer than the value set. Communication information Fig. 66 shows the relationship between nominal motor speed/max speed and the acceleration time. The same is valid for the deceleration time.

Linear example: Process Min[324]=10 bottles/s at F(Value)PrMin[327]=150; Process Max[325]=100 bottles/s at F(Value)PrMax[328]=1500. Prose gives rpm for150/1500. No general performance rating inferred.

328 F(Val) PrMax Stp A Max

331 Acc Time Stp A 10.0s

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

328 F Value Process Max metadata — PDF page 89

Source row Property or applicable mode Source value
1 Default: Max

328 F Value Process Max selections — PDF page 89

Source row Selection Integer code Description
1 Min -1 Min
2 Max -2 Max
3 0.000- 10000 0-10000 0.000-10000

328 communication — PDF page 89

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43314
2 Profibus slot/index 169/218
3 Fieldbus format Long, 1=1 rpm
4 Modbus format EInt

331 Acceleration Time metadata — PDF page 89

Source row Property or applicable mode Source value
1 Default: 10.0 s
2 Range: 0–3600 s

331 communication — PDF page 89

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43101
2 Profibus slot/index 169/5
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

Manual — Acceleration deceleration and motor potentiometer ramps — page 90

Manual reference: physical PDF page 90. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 66 Acceleration time and maximum speed Fig. 67 shows the settings of the acceleration and deceleration times with respect to the nominal motor speed. Fig. 67 Acceleration and deceleration times Deceleration Time [332] The deceleration time is defined as the time it takes for the motor to decelerate from nominal motor speed to 0 rpm. Communication information

NOTE: If the Dec Time is too short and the generator energy cannot be dissipated in a brake resistor, the motor is decelerated according to the overvoltage limit. The actual deceleration time may be longer than the value set. Acceleration Time Motor Potentiometer [333] It is possible to control the speed of the AC drive using the motor potentiometer function. This function con- trols the speed with separate up and down commands, over remote signals. The MotPot function has separate ramps settings which can be set in Acc MotPot [333] and Dec MotPot [334]. If the MotPot function is selected, this is the accelera- tion time for the MotPot up command. The acceleration time is defined as the time it takes for the motor poten- tiometer value to increase from 0 rpm to nominal speed. Communication information Deceleration Time Motor Potentiometer [334] If the MotPot function is selected, this is the decelera- tion time for the MotPot down command. The decelera- tion time is defined as the time it takes for the motor potentiometer value to decrease from nominal speed to 0 rpm. Communication information

rpm axis: Nominal Speed100% n_MOT; Max Speed80% n_MOT. t axis8s and10s; source illustration only.

rpm; Nom.Speed; Acc Time[331]; Dec Time[332]. Original timing geometry retained.

333 Acc MotPot Stp A 16.0s

332 Dec Time Stp A 10.0s

334 Dec MotPot Stp A 16.0s

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

333 Acceleration MotPot metadata — PDF page 90

Source row Property or applicable mode Source value
1 Default: 16.0 s
2 Range: 0.50–3600 s

333 communication — PDF page 90

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43103
2 Profibus slot/index 169/7
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

332 Deceleration Time metadata — PDF page 90

Source row Property or applicable mode Source value
1 Default: 10.0 s
2 Range: 0–3600 s

332 communication — PDF page 90

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43102
2 Profibus slot/index 169/6
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

334 communication — PDF page 90

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43104
2 Profibus slot/index 169/8
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

Manual — Minimum speed ramp and S curve conditions — page 91

Manual reference: physical PDF page 91. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Acceleration Time to Minimum Speed [335] If minimum speed, [341]>0 rpm, is used in an applica- tion, the AC drive uses separate ramp times below this level. With Acc>MinSpeed [335] and Dec<MinSpeed [336] you can set the required ramp times. Short times can be used to prevent damage and excessive pump wear due too little lubrication at lower speeds. Longer times can be used to fill up a system smoothly and pre- vent water hammer due to rapidly exhausting air from the pipe system. If a Minimum speed is programmed, this parameter will be used to set the acceleration time to the minimum speed at a run command. The ramp time is defined as the time it takes for the motor to accelerate from 0 rpm to nominal motor speed. Communication information Fig. 68

Deceleration Time from Minimum Speed [336] If a minimum speed is programmed, this parameter will be used to set the deceleration time from the minimum speed to 0 rpm at a stop command. The ramp time is defined as the time it takes for the motor to decelerate from the nominal motor speed to 0 rpm. Communication information Acceleration Ramp Type [337] Sets the type of all the acceleration ramps in a parame- ter set. See Fig. 69. Depending on the acceleration and deceleration requirements for the application, the shape of both the ramps can be selected. For applica- tions where speed changes need to be started and stopped smoothly, such as a conveyor belt with materi- als that can drop following a quick speed change, the ramp shape can be adapted to a S-shape and prevent speed change shocks. For applications that are not critical in this, the speed change can be fully linear over the complete range. NOTE: For S-curve ramps the ramp times, [331] and [332], defines the maximum acceleration and deceleration rated, i.e. linear part of S-curve, just as for the linear ramps. The S-curves are implemented so that for a speed step below sync speed the ramps are fully S-shaped while for larger steps the middle part will be linear. Therefore will a S-curve ramp from 0 –sync speed take 2 x Time while a step from 0–2 x sync speed will take 3 x Time (middle part 0.5sync speed – 1.5sync speed linear). Also valid for menu [337], D.eceleration ramp type.

rpm; Nom.Speed[225]; Max speed[343]; Min speed[341]; [331],[332],[335],[336]; time. Original ramp geometry retained.

336 Dec<Min Spd Stp A 10.0s

335 Acc>Min Spd Stp A 10.0s

337 Acc Rmp Stp A Linear

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

336 Deceleration from Min Speed metadata — PDF page 91

Source row Property or applicable mode Source value
1 Default: 10.0 s
2 Range: 0-3600 s

336 communication — PDF page 91

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43106
2 Profibus slot/index 169/10
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

335 communication — PDF page 91

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43105
2 Profibus slot/index 169/9
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

337 Acceleration Ramp metadata — PDF page 91

Source row Property or applicable mode Source value
1 Default: Linear

337 Acceleration Ramp selections — PDF page 91

Source row Selection Integer code Description
1 Linear 0 Linear acceleration ramp.
2 S-Curve 1 S-shape acceleration ramp.

Manual — Ramp types start mode and spinstart — page 92

Manual reference: physical PDF page 92. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Fig. 69 Shape of acceleration ramp Deceleration Ramp Type [338] Sets the ramp type of all deceleration parameters in a parameter set Fig. 70. Communication information Fig. 70 Shape of deceleration ramp

Start Mode [339] Sets the way of starting the motor when a run com- mand is given. Communication information Spinstart [33A] The spinstart will smoothly start a motor which is already rotating by catching the motor at the actual speed and control it to the desired speed. If in an appli- cation, such as an exhausting fan, the motor shaft is already rotating due to external conditions, a smooth start of the application is required to prevent excessive wear. With the spinstart=on, the actual control of the motor is delayed due to detecting the actual speed and rotation direction, which depend on motor size, running conditions of the motor before the Spinstart, inertia of the application, etc. Depending on the motor electrical time constant and the size of the motor, it can take maximum a couple of minutes before the motor is caught.

rpm; Linear; S-curve; t. Original geometry retained.

S-curve; Linear; t. No unstated axis unit added.

339 Start Mode Stp A Normal DC

338 Dec Rmp Stp A Linear

33A Spinstart Stp A Off

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

337 communication continuation from PDF91 — PDF page 92

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43107
2 Profibus slot/index 169/11
3 Fieldbus format UInt
4 Modbus format UInt

339 Start Mode metadata — PDF page 92

Source row Property or applicable mode Source value
1 Default: Normal DC

339 Start Mode selections — PDF page 92

Source row Selection Integer code Description
1 Fast 0 The motor flux increases gradually. The motor shaft starts rotating immediately once the Run command is given.
2 Normal DC 1 After a Run command the motor will be magnetised first and the stator resistance is measured. Depending on the motor time constant and the size of the motor it can take up to 1.3 s before the motor shaft starts to rotate. This will provide better control of the motor when starting.

339 communication — PDF page 92

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43109
2 Profibus slot/index 169/13
3 Fieldbus format UInt
4 Modbus format UInt

338 Deceleration Ramp metadata — PDF page 92

Source row Property or applicable mode Source value
1 Default: Linear
2 Selection: Same as menu [337]

338 communication — PDF page 92

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43108
2 Profibus slot/index 169/12
3 Fieldbus format UInt
4 Modbus format UInt

33A Spinstart metadata — PDF page 92

Source row Property or applicable mode Source value
1 Default: Off

33A Spinstart selections — PDF page 92

Source row Selection Integer code Description
1 Off 0 No spinstart. If the motor is already running the AC drive can trip or will start with high current.
2 On 1 Spinstart will allow the start of a running motor without tripping or high inrush currents.

Manual — Stop mode and mechanical brake controls — page 93

Manual reference: physical PDF page 93. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Stop Mode [33B] When the AC drive is stopped, different methods to come to a standstill can be selected in order to opti- mize the stop and prevent unnecessary wear. Stop Mode sets the way of stopping the motor when a Stop command is given. Communication information 11.3.4 Mechanical brake control The four brake-related menus [33C] to [33F] can be used to control mechanical brakes e.g. to handle basic hoisting functions. When hoisting a load generally a mechanical brake holds the load when the AC drive is not running. To prevent the load from falling down a holding torque must be initiated before the mechanical brake is released. On the other hand when stopping hoisting the brake must be activated before the holding torque is removed. Support is included for a Brake Acknowledge signal via a digital input. It is monitored using a brake fault time parameter. Additional output and trip/warning signals are also included. The acknowledge signal is either con- nected from the brake contactor or from a proximity switch on the brake. The brake acknowledge signal can also be used to improve safety by preventing hoist falling load in case the brake is not engaged when stopping. Brake not released - Brake Fault trip During start and running the brake acknowledge signal is compared to the actual brake output signal and if no acknowledge, i.e. brake not released, while brake out-

put is high for the Brake Fault time [33H], then a Brake trip is generated. Brake not engaged - Brake Warning and continued operation (keep torque) The brake acknowledge signal is compared to the actual brake output signal at stop. If acknowledge is still active, i.e. brake not engaged, while brake output is low for the Brake Engage time [33E] then a Brake warn- ing is generated and the torque is kept, i.e. prolonging normal brake engage mode, until brake closes or an emergency action is needed by the operator, such as setting down the load. Brake Release Time [33C] The Brake Release Time sets the time the AC drive delays before ramping up to whatever final reference value is selected. During this time a predefined speed can be generated to hold the load where after the mechanical brake finally releases. This speed can be selected at Release Speed, [33D]. Immediate after the brake release time expiration the brake lift signal is set. The user can set a digital output or relay to the function Brake. This output or relay can control the mechanical brake. Communication information Fig. 71 shows the relation between the four Brake func- tions. • Brake Release Time [33C] • Start Speed [33D] • Brake Engage Time [33E] • Brake Wait Time [33F] The correct time setting depends on the maximum load and the properties of the mechanical brake. During the brake release time it is possible to apply extra holding torque by setting a start speed reference with the func- tion start speed [33D]

33B Stop Mode Stp A Decel

33C Brk Release Stp A 0.00s

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

33A communication continuation from PDF92 — PDF page 93

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43110
2 Profibus slot/index 169/14
3 Fieldbus format UInt
4 Modbus format UInt

33B Stop Mode metadata — PDF page 93

Source row Property or applicable mode Source value
1 Default: Decel

33B Stop Mode selections — PDF page 93

Source row Selection Integer code Description
1 Decel 0 The motor decelerates to 0 rpm according to the set deceleration time.
2 Coast 1 The motor freewheels naturally to 0 rpm.

33B communication — PDF page 93

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43111
2 Profibus slot/index 169/15
3 Fieldbus format UInt
4 Modbus format UInt

33C Brake Release Time metadata — PDF page 93

Source row Property or applicable mode Source value
1 Default: 0.00 s
2 Range: 0.00–3.00 s

33C communication — PDF page 93

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43112
2 Profibus slot/index 169/16
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

Manual — Brake output timing and release speed — page 94

Manual reference: physical PDF page 94. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

. Fig. 71 Brake Output functions NOTE: Although this function is designed to operate a mechanical brake via the digital outputs or relays (set to brake function) controlling a mechanical brake, it can also be used without a mechanical brake and hold the load in a fixed position. Release Speed [33D] The release speed only operates with the brake func- tion: brake release [33C]. The release speed is the ini- tial speed reference during the brake release time. The torque reference is initialized to 90% of TNOM to ensure that the load is held in place. Communication information

Brake Engage Time [33E] The brake engage time is the time the load is held while the mechanical brake engages. It is also used to get a firm stop when transmissions, etc. cause “whiplash” effects. In other words, it compensates for the time it takes to engage a mechanical brake. Communication information

n; Start; Release Speed[33D]; t; Brake release time[33C]; Brake wait time[33F]; Brake engage time[33E]; Mechanical Brake Open/Closed; Brake Relay Output On/Off. Visible source note: Action must take place within hse time intervals. Timing relationships require original chart; no inferred wiring.

33D Release Spd Stp A 0rpm

33E Brk Engage Stp A 0.00s

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

33D Release Speed metadata — PDF page 94

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Range: - 4x Sync. Speed to 4x Sync.
3 Depend on: 4xmotor sync speed, 1500 rpm for 1470 rpm motor.

33E Brake Engage Time metadata — PDF page 94

Source row Property or applicable mode Source value
1 Default: 0.00 s
2 Range: 0.00–3.00 s

33E communication — PDF page 94

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43114
2 Profibus slot/index 169/18
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

33D communication — PDF page 94

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43113
2 Profibus slot/index 169/17
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

Manual — Brake wait vector brake and release torque — page 95

Manual reference: physical PDF page 95. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Wait Before Brake Time [33F] The brake wait time is the time to keep brake open and to hold the load, either in order to be able to speed up immediately, or to stop and engage the brake. Communication information Vector Brake [33G] Braking by increasing the internal electrical losses in the motor. Communication information Brake Fault trip time [33H] The “Brake Fault trip time” for “Brake not released” function is specified in this menu.

Communication information Note: The Brake Fault trip time should be set to longer time than the Brake release time[33C]. The “Brake not engaged” warning is using the setting of parameter “Brake Engaged time [33E]”. Following Figure shows principle of brake operation for fault during run (left) and during stop (right). Release torque [33I] The Brake Release Time [33C] sets the time the VSD delays before ramping up to whatever final speed refer- ence value is selected, to allow the brake to be fully opened. During this time a holding torque to prevent roll-back of the load can be activated. The parameter Release Torque [33I] is used for this purpose. The release torque initiates the torque reference from the speed controller during the Brake Release Time [33C]. The release torque defines a minimum level of release (holding) torque. The set release torque is inter- nally overruled if the actual required holding torque measured at the previous closing of brake is higher. The release torque is set with sign in order to define the holding torque direction. Communication information Note! Function is deactivated if set to 0%. Note! Release Torque [33I] has priority over torque reference initialization by Release Speed [33D].

33F Brk Wait Stp A 0.00s

33G Vector Brake Stp A Off

33I Release Trq Stp A 0%

33H Brk Fault Stp A 1.00s

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

33H Brake Fault communication from lower left column — PDF page 95

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43117
2 Profibus slot/index 169/21
3 Fieldbus format Long, 1=0.1s
4 Modbus format EInt

33F Brake Wait Time metadata — PDF page 95

Source row Property or applicable mode Source value
1 Default: 0.00 s
2 Range: 0.00–30.0 s

33F communication — PDF page 95

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43115
2 Profibus slot/index 169/19
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

33G Vector Brake metadata — PDF page 95

Source row Property or applicable mode Source value
1 Default: Off

33G Vector Brake selections — PDF page 95

Source row Selection Integer code Description
1 Off 0 Vector brake switched off. AC drive brakes normal with voltage limit on the DC link.
2 On 1 Maximum AC drive current (ICL) is available for braking.

33I Release Torque metadata — PDF page 95

Source row Property or applicable mode Source value
1 Default: 0%
2 Range -400% to 400%

33G communication — PDF page 95

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43116
2 Profibus slot/index 169/20
3 Fieldbus format UInt
4 Modbus format UInt

33I communication — PDF page 95

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43118
2 Profibus slot/index 169/22
3 Fieldbus format Long, 1=1H%
4 Modbus format EInt

33H Brake Fault Time metadata — PDF page 95

Source row Property or applicable mode Source value
1 Default: 1.00s
2 Range 0.00 - 5.00s

Manual — Brake fault diagram minimum speed and sleep — page 96

Manual reference: physical PDF page 96. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 72 Principle of Brake operation for fault during run and during 11.3.5 Speed [340] Menu with all parameters for settings regarding to speeds, such as Min/Max speeds, Jog speeds, Skip speeds. Minimum Speed [341] Sets the minimum speed. The minimum speed will operate as an absolute lower limit. Used to ensure the motor does not run below a certain speed and to main- tain a certain performance. NOTE: A lower speed value than the set minimum speed can be shown in the display due to motor slip. Communication information

stop Stop/Sleep when less than Minimum Speed [342] With this function it is possible to put the AC drive in “sleep mode” when it is running at minimum speed for the length of time set, due to process value feedback or a reference value that corresponds to a speed lower than the min speed set. The AC drive will go into sleep mode after programmed time. When the reference sig- nal or process value feedback raises the required speed value above the min speed value, the AC drive will automatically wake up and ramp up to the required speed. NOTE: Menu [386] has higher priority than menu [342]. Communication information

During run /During stop. Start; Running; Torque; Speed>0; Brake relay; Brake acknowledge; Brake Trip; Brake warning; Brake release time33C; Brake wait time33F; Brake engage time33E; <33H;33H;Brake Fault trip time. * Memorized load torque level, if function activated with parameter[33I]Release Torque. ** Time for operator to set down the load. Original geometry authoritative.

341 Min Speed Stp A 0rpm

342 Stp<MinSpd Stp A Off

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

341 Minimum Speed metadata — PDF page 96

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Range: 0 - Max Speed
3 Dependent on: Set/View ref [310]

342 Stop Below Minimum Speed metadata — PDF page 96

Source row Property or applicable mode Source value
1 Default: Off

342 Stop Below Minimum Speed selections — PDF page 96

Source row Selection Integer code Description
1 Off 0 Off
2 1–3600 1–3600 1–3600 s

341 communication — PDF page 96

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43121
2 Profibus slot/index 169/25
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

342 communication — PDF page 96

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43122
2 Profibus slot/index 169/26
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

Manual — Maximum and skipped speed settings — page 97

Manual reference: physical PDF page 97. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 73 Maximum Speed [343] Sets the maximum speed. The maximum speed will operate as an absolute maximum limit. This parameter is used to prevent damage due to high speed. The synchronous speed (Sync-spd) is determined by the parameter motor speed [225].. Communication information NOTE: It is not possible to set the maximum speed lower than the minimum speed. Note: Maximum speed [343] has priority over Min Speed [341], i.e. if [343] is set below [341] then the drive will run at [343] Max Speed with acceleration times given by [335] and [336] respectively.

Skip Speed 1 Low [344] Within the Skip Speed range High to Low, the speed cannot be constant in order to avoid mechanical reso- nance in the AC drive system. When Skip Speed Low £ Ref Speed £ Skip Speed High, then Output Speed=Skip Speed HI during deceleration and Output Speed=Skip Speed LO during acceleration. Fig. 74 shows the function of skip speed hi and low. Between Skip Speed HI and LO, the speed changes with the set acceleration and deceleration times. Skipspd1 LO sets the lower value for the 1st skip range. Communication information Fig. 74 Skip Speed NOTE: The two Skip Speed ranges may be overlapped.

PID ref;PID fb;PID out;Min speed;[342]. Original timing chart retained.

n;Skip Speed HI;Skip Speed LO;Speed Reference. Original direction arrows and geometry retained, no numerical interpolation.

344 SkipSpd 1 Lo Stp A 0rpm

343 Max Speed Stp A Sync Speed

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

344 Skip Speed 1 Low metadata — PDF page 97

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Range: 0 - 4 x Motor Sync Speed

343 Maximum Speed metadata — PDF page 97

Source row Property or applicable mode Source value
1 Default: Sync Speed

343 Maximum Speed selections — PDF page 97

Source row Selection Integer code Description
1 Sync Speed 0 Synchronous speed, i.e. no load speed, at nominal frequency.
2 1-24000rpm 1- 24000 Min Speed - 4 x Motor Sync Speed

344 communication — PDF page 97

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43124
2 Profibus slot/index 169/28
3 Fieldbus format Int
4 Modbus format Int

343 communication — PDF page 97

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43123
2 Profibus slot/index 169/27
3 Fieldbus format Int, 1=1 rpm
4 Modbus format UInt

Manual — Skip speed ranges and jog controls — page 98

Manual reference: physical PDF page 98. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Skip Speed 1 High [345] Skipspd1 HI sets the higher value for the 1st skip range. Communication information Skip Speed 2 Low [346] The same function as menu [344] for the 2nd skip range. Communication information Skip Speed 2 High [347] The same function as menu [345] for the 2nd skip range. Communication information

Jog Speed [348] The Jog Speed function is activated by one of the digital inputs. The digital input must be set to the Jog function [520]. The Jog command/function will automatically generate a run command as long as the Jog command/ function is active. The rotation is determined by the polarity of the set Jog Speed. Example If Jog Speed = -10, this will give a Run Left command at 10 rpm regardless of RunL or RunR commands. Fig. 75 shows the function of the Jog command/function. Communication information Fig. 75 Jog command

f;Jog Freq;t;Jog command;t. Source drawing retained; command duration geometry not transformed into numerical settings.

345 SkipSpd 1 Hi Stp A 0rpm

348 Jog Speed Stp A 50rpm

346 SkipSpd 2 Lo Stp A 0rpm

347 SkipSpd 2 Hi Stp A 0rpm

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

345 Skip Speed 1 High metadata — PDF page 98

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Range: 0 – 4 x Sync Speed

345 communication — PDF page 98

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43125
2 Profibus slot/index 169/29
3 Fieldbus format Int
4 Modbus format Int

348 Jog Speed metadata — PDF page 98

Source row Property or applicable mode Source value
1 Default: 50 rpm
2 Range: -4 x motor sync speed to +4 x motor sync speed
3 Dependent on: Defined motor sync speed. Max = 400%, nor- mally max=AC drive Imax/motor Inom x 100%.

346 Skip Speed 2 Low metadata — PDF page 98

Source row Property or applicable mode Source value
1 Default: 0 rpm
2 Range: 0 – 4 x Motor Sync Speed

348 communication — PDF page 98

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43128
2 Profibus slot/index 169/32
3 Fieldbus format Int
4 Modbus format Int

346 communication — PDF page 98

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43126
2 Profibus slot/index 169/30
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

347 communication — PDF page 98

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43127
2 Profibus slot/index 169/31
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

Manual — Torque and IxR compensation — page 99

Manual reference: physical PDF page 99. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.3.6 Torques [350] Menu with all parameters for torque settings. Maximum Torque [351] Sets the maximum torque. This Maximum Torque oper- ates as an upper torque limit. A Speed Reference is always necessary to run the motor. Communication information NOTE: The Max Torque parameter will limit the maxmum output current of the AC drive following the relation: 100% Tmot corresponds to 100% Imot. The maximum possible setting for parameter 351 is limited by Inom/Imot x 120%, but not higher than 400%. NOTE: The power loss in the motor will increase by the square of the torque when operating above 100%. 400% torque will result in 1600% power loss, which will increase the motor temperature very quickly. IxR Compensation [352] This function compensates for the drop in voltage over different resistances such as (very) long motor cables, chokes and motor stator by increasing the output volt- age at a constant frequency. IxR Compensation is most important at low frequencies and is used to obtain a higher starting torque. The maximum voltage increase is 25% of the nominal output voltage. See Fig. 76. Selecting “Automatic” will use the optimal value accord- ing to the internal model of motor. “User-Defined” can be selected when the start conditions of the application do not change and a high starting torque is always required. A fixed IxR Compensation value can be set in the menu [353]. NOTE: This menu is visible only in V/Hz mode.

Communication information Fig. 76 IxR Comp at Linear V/Hz curve IxR Comp_user [353] Only visible if User-Defined is selected in previous menu. Communication information NOTE: A too high level of IxR Compensation could cause motor saturation. This can cause a “Power Fault” trip. The effect of IxR Compensation is stronger with higher power motors.

T_MOT(Nm) = P_MOT(kw) ×9550 / n_MOT(rpm). Literal source formula; no derived operating values.

U percent100 and25; f Hz10,20,30,40,50. Labels IxR Comp=25% and IxR Com=0%. Original shaded-region geometry retained.

352 IxR Comp Stp A Off

351 Max Torque Stp A 120%

353 IxR CompUsr Stp A 0.0%

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

Default: Off

Range: 0-25%

352 IxR Compensation metadata — PDF page 99

Source row Property or applicable mode Source value
1 Default: Off

352 IxR Compensation selections — PDF page 99

Source row Selection Integer code Description
1 Off 0 Function disabled
2 Automatic 1 Automatic compensation
3 User Defined 2 User defined value in percent.

352 communication — PDF page 99

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43142
2 Profibus slot/index 169/46
3 Fieldbus format UInt
4 Modbus format UInt

351 Maximum Torque metadata — PDF page 99

Source row Property or applicable mode Source value
1 Default: 120% calculated from the motor data
2 Range: 0–400%

351 communication — PDF page 99

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43141
2 Profibus slot/index 169/45
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

353 User IxR Compensation metadata — PDF page 99

Source row Property or applicable mode Source value
1 Default: 0.0% ⟦blank source cell⟧
2 Range: 0-25% x UNOM (0.1% of resolution)

353 communication — PDF page 99

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43143
2 Profibus slot/index 169/47
3 Fieldbus format Long
4 Modbus format EInt

Manual — Flux optimization and maximum power — page 100

Manual reference: physical PDF page 100. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

NOTE: The motor may be overheated at low speed. Therefore it is important that the Motor I2t Current [232] is set correctly. Flux Optimization [354] Flux Optimization reduces the energy consumption and the motor noise, at low or no load conditions. Flux Optimization automatically decreases the V/Hz ratio, depending on the actual load of the motor when the process is in a steady situation. Fig. 77 shows the area within which the Flux Optimization is active. Communication information Fig. 77 Flux Optimizing NOTE: Flux optimization works best at stable situations in slow changing processes.

Maximum power [355] Sets maximum power. Can be used for limiting motor power in field weakening operation. This function oper- ates as an upper power limit and internally limits the parameter Max Torque [351] according to : Tlimit = Plimit[%] / (Actual Speed / Sync Speed) NOTE: The maximum possible setting for parameter 355 is limited by INOM/IMOT x 120%, but not higher than 400%. Communication information

U percent100;f50Hz;Flux optimizing area. No interpolated operating points.

355 Max Power Stp A Off

354 Flux optim Stp A Off

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

Adjacent source context — repeated to preserve continuation:

355 Maximum Power metadata — PDF page 100

Source row Property or applicable mode Source value
1 Default: Off

355 Maximum Power selections — PDF page 100

Source row Selection Integer code Description
1 Off 0 Off. No power limit
2 1 - 400 1 - 400 1 - 400% of motor nominal power

354 Flux Optimization selections — PDF page 100

Source row Selection Integer code Description
1 Off 0 Function disabled
2 On 1 Function enabled

355 communication — PDF page 100

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43145
2 Profibus slot/index 169/49
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

354 communication — PDF page 100

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43144
2 Profibus slot/index 169/48
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Motor potentiometer and preset references — page 101

Manual reference: physical PDF page 101. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.3.7 Preset References [360] Motor Potentiometer [361] Sets the properties of the motor potentiometer func- tion. See the parameter DigIn1 [521] for the selection of the motor potentiometer function. Communication information Fig. 78 MotPot function Preset Ref 1 [362] to Preset Ref 7 [368] Preset speeds have priority over the analogue inputs. Preset speeds are activated by the digital inputs. The digital inputs must be set to the function Pres. Ref 1, Pres. Ref 2 or Pres. Ref 4.

Depending on the number of digital inputs used, up to 7 preset speeds can be activated per parameter set. Using all the parameter sets, up to 28 preset speeds are possible. Communication information The same settings are valid for the menus: [363] Preset Ref 2, with default 250 rpm [364] Preset Ref 3, with default 500 rpm [365] Preset Ref 4, with default 750 rpm [366] Preset Ref 5, with default 1000 rpm [367] Preset Ref 6, with default 1250 rpm [368] Preset Ref 7, with default 1500 rpm The selection of the presets is as in Table 24. Table 24 1)= selected if only one preset reference is active 1 = active input 0 = non active input NOTE: If only Preset Ctrl3 is active, then the Preset Ref 4 can be selected. If Presets Ctrl2 and 3 are active, then the Preset Ref 2, 4 and 6 can be selected.

n;t;Motpot UP;t;Motpot DOWN;t. Command/response geometry remains original-only.

362 Preset Ref 1 Stp A 0rpm

361 Motor Pot Stp A Non Volatie

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

11)

Adjacent source context — repeated to preserve continuation:

362 Preset Reference 1 metadata — PDF page 101

Source row Property or applicable mode Source value
1 Default: Speed, 0 rpm
2 Dependent on: Process Source [321] and Process Unit [322]
3 Speed mode 0 - max speed [343]
4 Torque mode 0 - max torque [351]
5 Other modes Min according to menu [324] - max according to menu [325]

361 Motor Potentiometer metadata — PDF page 101

Source row Property or applicable mode Source value
1 Default: Non Volatile

361 Motor Potentiometer selections — PDF page 101

Source row Selection Integer code Description
1 Volatile 0 After a stop, trip or power down, the AC drive will start always from zero speed (or minimum speed, if selected).
2 Non volatile 1 Non Volatile. After a stop, trip or power down of the AC drive, the reference value at the moment of the stop will be memorized. After a new start command the output speed will resume to this saved value.

362–368 Preset References communication — PDF page 101

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43132–43138
2 Profibus slot/index 169/36–169/42
3 Fieldbus format Long
4 Modbus format EInt

361 communication — PDF page 101

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43131
2 Profibus slot/index 169/35
3 Fieldbus format UInt
4 Modbus format UInt

Table24 Preset selection truth table — PDF page 101

Source row Preset Ctrl3 Preset Ctrl2 Preset Ctrl1 Output Speed
1 0 0 0 Analogue reference
2 0 0 1 [footnote 1)] Preset Ref 1
3 0 1 [footnote 1)] 0 Preset Ref 2
4 0 1 1 Preset Ref 3
5 1 [footnote 1)] 0 0 Preset Ref 4
6 1 0 1 Preset Ref 5
7 1 1 0 Preset Ref 6
8 1 1 1 Preset Ref 7

Manual — Keyboard reference and speed PI autotune — page 102

Manual reference: physical PDF page 102. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Keyboard reference mode [369] This parameter sets how the reference value [310] is edited. Communication information NOTE: When Key Ref Mode is set to MotPot, the reference value ramp times are according to the Acc MotPot [333] and Dec MotPot [334] settings. Actual speed ramp will be limited according to Acc Time [331] and Dec Time [332].

11.3.8 PI Speed Control [370] The AC drive has an internal speed controller, which is used to keep the shaft speed equal to the set speed reference. This internal speed controller works without an external feedback. With the parameters speed P gain [372] and speed I time [373] the controller can be optimized manually. Speed PI Autotune [371] The function speed autotune will perform a torque step change, and measures the reaction on shaft speed. It automatically sets the internal speed I time to its opti- mum value. The speed PI autotune must be done dur- ing operation with the motor load connected and the motor running. “Spd PI Auto” will be flashing in the dis- play during the autotune operation. When the test is successfully concluded, the display will show “Spd PI OK!” for 3 s. Communication information NOTE: Run the autotune at speed lower than 80% of the nominal motor speed. Otherwise autotune will fail. NOTE: The setting will automatically return to Off when the autotuning is finished. NOTE: This menu is only visible if AC drive Mode = Speed or V/Hz.

369 Key Ref Mode Stp A MotPot

371 Spd PI Auto Stp A Off

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

369 Keyboard Reference Mode metadata — PDF page 102

Source row Property or applicable mode Source value
1 Default: MotPot

369 Keyboard Reference Mode selections — PDF page 102

Source row Selection Integer code Description
1 Normal 0 The reference value is edited as a normal parameter (the new reference value is activated when Enter is pressed after the value has been changed). The Acc Time [331] and Dec Time [332] are used.
2 MotPot 1 The reference value is edited using the motor potentiometer function (the new reference value is activated directly when the key + or - is pressed). The Acc MotPot [333] and Dec MotPot [334] are used.

371 Speed PI Autotune metadata — PDF page 102

Source row Property or applicable mode Source value
1 Default: Off

371 Speed PI Autotune selections — PDF page 102

Source row Selection Integer code Description
1 Off 0 ⟦blank source cell⟧
2 On 1 ⟦blank source cell⟧

369 communication — PDF page 102

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43139
2 Profibus slot/index 169/43
3 Fieldbus format UInt
4 Modbus format UInt

371 communication — PDF page 102

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43151
2 Profibus slot/index 169/55
3 Fieldbus format UInt
4 Modbus format UInt

Manual — PI speed and PID controls — page 103

Manual reference: physical PDF page 103. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Speed P Gain [372] For adjusting the P gain of the internal speed controller. The speed P gain must be manually tuned for a faster reaction to load changes. The speed P gain can be increased until there is audible noise from the motor and then decreased until the noise disappears. Communication information Speed I Time [373] To adjust the time of the internal speed controller see parameter Speed PI Autotune [371]. Communication information NOTE: The default settings are calculated for a standard 4-pole motor without load according to the nominal power of the AC drive.

11.3.9 PID Process Control [380] The PID controller is used to control an external process via a feedback signal. The reference value can be set via analogue input AnIn1, at the Control Panel [310] by using a Preset Reference, or via serial communication. The feedback signal (actual value) must be connected to an analogue input that is set to the function Process Value. Process PID Control [381] This function enables the PID controller and defines the response to a changed feedback signal. Communication information PID P Gain [383] Setting the P gain for the PID controller. Communication information

372 Spd P Gain StpA

381 PID Control Stp A Off

373 Spd I Time StpA

383 PID P Gain Stp A 1.0

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

372 Speed P Gain metadata — PDF page 103

Source row Property or applicable mode Source value
1 Default: See note
2 Range: 0.0–60.0

381 Process PID Control metadata — PDF page 103

Source row Property or applicable mode Source value
1 Default: Off

381 Process PID Control selections — PDF page 103

Source row Selection Integer code Description
1 Off 0 PID control deactivated.
2 On 1 The speed increases when the feedback value decreases. PID settings according to menus [381] to [385].
3 Invert 2 The speed decreases when the feedback value decreases. PID settings according to menus [383] to [385].

372 communication — PDF page 103

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43152
2 Profibus slot/index 169/56
3 Fieldbus format Long, 1=0.1
4 Modbus format EInt

373 Speed I Time metadata — PDF page 103

Source row Property or applicable mode Source value
1 Default: See note
2 Range: 0.05–100 s

381 communication — PDF page 103

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43154
2 Profibus slot/index 169/58
3 Fieldbus format UInt
4 Modbus format UInt

373 communication — PDF page 103

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43153
2 Profibus slot/index 169/57
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

383 PID P Gain metadata — PDF page 103

Source row Property or applicable mode Source value
1 Default: 1.0
2 Range: 0.0–30.0

383 communication — PDF page 103

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43156
2 Profibus slot/index 169/60
3 Fieldbus format Long, 1=0.1
4 Modbus format EInt

Manual — PID integration differentiation and sleep — page 104

Manual reference: physical PDF page 104. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 79 Closed loop PID control PID I Time [384] Setting the integration time for the PID controller. Communication information Process PID D Time [385] Setting the differentiation time for the PID controller. Communication information

PID sleep functionality This function is controlled via a wait delay and a sepa- rate wake-up margin condition. With this function it is possible to put the AC drive in “sleep mode” when the process value is at it’s set point and the motor is run- ning at minimum speed for the length of the time set in [386]. By going into sleep mode, the by the application consumed energy is reduced to a minimum. When the process feedback value goes below the set margin on the process reference as set in [387], the AC drive will wake up automatically and normal PID operation con- tinues, see examples. PID sleep when less than minimum speed [386] If the PID output is equal to or less than minimum speed for given delay time, the AC drive will go to sleep. Communication information NOTE: Menu [386] has higher priority than menu [342]. PID Activation Margin [387] The PID activation (wake-up) margin is related to the process reference and sets the limit when the AC drive should wake-up/start again. Communication information NOTE: The margin is always a positive value.

Process reference (+);Process feedback (−);Process PID;AC drive;M;Process. Original loop connections retained; no wiring instruction inferred.

384 PID I Time Stp A 1.00s

386 PID<MinSpd Stp A Off

385 PID D Time Stp A 0.00s

387 PID Act Marg Stp A 0rpm

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

384 PID I Time metadata — PDF page 104

Source row Property or applicable mode Source value
1 Default: 1.00 s
2 Range: 0.01–300 s

386 PID Sleep Delay metadata — PDF page 104

Source row Property or applicable mode Source value
1 Default: Off
2 Range: Off, 0.01 –3600 s

384 communication — PDF page 104

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43157
2 Profibus slot/index 169/61
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

386 communication — PDF page 104

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43371
2 Profibus slot/index 170/20
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

385 PID D Time metadata — PDF page 104

Source row Property or applicable mode Source value
1 Default: 0.00 s
2 Range: 0.00–30 s

387 PID Activation Margin metadata — PDF page 104

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0 –10000 in Process unit

385 communication — PDF page 104

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43158
2 Profibus slot/index 169/62
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

387 communication — PDF page 104

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43372
2 Profibus slot/index 170/21
3 Fieldbus format Long
4 Modbus format EInt

Manual — Normal inverted and steady-state PID — page 105

Manual reference: physical PDF page 105. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example 1 PID control = normal (flow or pressure control) [321] = F (AnIn) [322] = Bar [310] = 20 Bar [342] = 2 s (inactive since [386] is activated and have higher priority) [381]= On [386] = 10 s [387] = 1 Bar The AC drive will stop/sleep when the speed (PID out- put) is below or equal to Min Speed for 10 seconds. The AC drive will activate/wake up when the “Process value” goes below the PID Activation Margin which is related to the process reference, i.e. goes below (20-1) Bar. See Fig. 80. Fig. 80 PID Stop/sleep with normal PID Example 2 PID control = inverted (tank level control) [321] = F (AnIn) [322] = m [310] = 7 m [342] = 2 s (inactive since [386] is activated and have higher priority) [381]= Inverted [386] = 30 s [387] = 1 m The AC drive will stop/sleep when the speed (PID out- put) is below or equal to Min Speed for 30 seconds. The AC drive will activate/wake up when the “Process value” goes above the PID Activation Margin which is related to the process reference, i.e. goes above (7+1) m. See Fig. 81. Fig. 81 PID Stop/sleep with inverted PID

PID Steady State Test [388] In application situations where the feedback can become independent of the motor speed, this PID Steady Test function can be used to overrule the PID operation and force the AC drive to go in sleep mode i.e. the AC drive automatically reduces the output speed while at the same time ensures the process value. Example: pressure controlled pump systems with low/ no flow operation and where the process pressure has become independent of the pump speed, e.g. due to slowly closed valves. By going into Sleep mode, heating of the pump and motor will be avoided and no energy is spilled. PID Steady state test delay. NOTE: It is important that the system has reached a stable situation before the Steady State Test is initiated. Communication information PID Steady State Margin [389] PID steady state margin defines a margin band around the reference that defines “steady state operation”. During the steady state test the PID operation is over- ruled and the AC drive is decreasing the speed as long as the PID error is within the steady state margin. If the PID error goes outside the steady state margin the test failed and normal PID operation continues, see exam- ple. Communication information

[711]Process Value;[310]Process Ref;[387];[712]Speed;[386];[341]Min Speed;Stop/Sleep;Activate/Wake up. Example conditions in same-page prose.

388 PID Stdy Tst Stp A Off

389 PID Stdy Mar Stp A 0

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

388 PID Steady State Test metadata — PDF page 105

Source row Property or applicable mode Source value
1 Default: Off
2 Range: Off, 0.01–3600 s

388 communication — PDF page 105

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43373
2 Profibus slot/index 170/22
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

389 PID Steady State Margin metadata — PDF page 105

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0–10000 in process unit

389 communication — PDF page 105

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43374
2 Profibus slot/index 170/23
3 Fieldbus format Long, 1=0.01 s
4 Modbus format EInt

Manual — Steady-state test example and diagram — page 106

Manual reference: physical PDF page 106. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example: The PID Steady Test starts when the process value [711] is within the margin and Steady State Test Wait Delay has expired. The PID output will decrease speed with a step value which corresponds to the mar- gin as long as the Process value [711] stays within steady state margin. When Min Speed [341] is reached the steady state test was successful and stop/sleep is commanded if PID sleep function [386]and [387] is Fig. 82 Steady state test

activated. If the Process value [711] goes outside the set steady state margins then the test failed and normal PID operation will continue, see Fig. 82 .

[711]Process Value;[310]Process Ref;[389] upper/lower;[387];[388];time;Start steady state test;Stop steady state test;[712]Speed;Normal PID;Steady state test;Stop/Sleep;[341]Min Speed;[386]PID<Min Spd. Original chart authoritative; prose specifies conditions.

Manual — Pump enable drive count and master selection — page 107

Manual reference: physical PDF page 107. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.3.10Pump/Fan Control [390] The Pump Control functions are in menu [390]. The function is used to control a number of drives (pumps, fans, etc.) of which one is always driven by the AC drive. Pump enable [391] This function will enable the pump control to set all rel- evant pump control functions. Communication information Number of Drives [392] Sets the total number of drives which are used, includ- ing the Master AC drive. The setting here depends on the parameter Select Drive [393]. After the number of drives is chosen it is important to set the relays for the pump control. If the digital inputs are also used for sta- tus feedback, these must be set for the pump control according to; Pump 1 OK– Pump6 OK in menu [520]. NOTE: Used relays must be defined as Slave Pump or Master Pump. Used digital inputs must be defined as Pump Feedback.

Communication information Select Drive [393] Sets the main operation of the pump system. 'Sequence' and 'Runtime' are Fixed MASTER operation. 'All' means Alternating MASTER operation. Communication information NOTE: This menu will NOT be active if less than 3 drives are selected.

391 Pump enable Stp A Off

393 Select Drive Stp A Sequence

392 No of Drives Stp A 1

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

392 Number of Drives communication from lower left column — PDF page 107

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43162
2 Profibus slot/index 169/66
3 Fieldbus format UInt
4 Modbus format UInt

391 Pump Enable metadata — PDF page 107

Source row Property or applicable mode Source value
1 Default: Off

391 Pump Enable selections — PDF page 107

Source row Selection Integer code Description
1 Off 0 Pump control is switched off.
2 On 1 Pump control is on: - Pump control parameters [392] to [39G] appear and are activated according to default settings. - View functions [39H] to [39M] are added in the menu structure.

393 Select Drive metadata — PDF page 107

Source row Property or applicable mode Source value
1 Default: Sequence

393 Select Drive selections — PDF page 107

Source row Selection Integer code Description
1 Sequence 0 Fixed MASTER operation: - The additional drives will be selected in sequence, i.e. first pump 1 then pump 2 etc. - A maximum of 7 drives can be used.
2 Run Time 1 Fixed MASTER operation: - The additional drives will be selected depending on the Run Time. So the drive with the lowest Run Time will be selected first. The Run Time is monitored in menus [39H] to [39M] in sequence. For each drive the Run Time can be reset. - When drives are stopped, the drive with the longest Run Time will be stopped first. - Maximum 7 drives can be used.
3 All 2 Alternating MASTER operation: - When the drive is powered up, one drive is selected as the Master drive. The selection criteria depends on the Change Condition [394]. The drive will be selected according to the Run Time. So the drive with the lowest Run Time will be selected first. The Run Time is monitored in menus [39H] to [39M] in sequence. For each drive the Run Time can be reset. - A maximum of 6 drives can be used.

391 communication — PDF page 107

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43161
2 Profibus slot/index 169/65
3 Fieldbus format UInt
4 Modbus format UInt

392 Number of Drives metadata — PDF page 107

Source row Property or applicable mode Source value
1 Default: 1
2 1-3 Number of drives if I/O Board is not used.
3 1-6 Number of drives if 'Alternating MASTER' is used, see Select Drive [393]. (I/O Board is used.)
4 1-7 Number of drives if 'Fixed MASTER' is used, see Select Drive [393]. (I/O Board is used.)

393 communication — PDF page 107

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43163
2 Profibus slot/index 169/67
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Pump master change conditions and timing — page 108

Manual reference: physical PDF page 108. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Change Condition [394] This parameter determines the criteria for changing the master. This menu only appears if Alternating MASTER operation is selected. The elapsed run time of each drive is monitored. The elapsed run time always deter- mines which drive will be the 'new' master drive. This function is only active if the parameter Select Drive [393]=All. Communication information NOTE: If the Status feedback inputs (DigIn 9 to Digin 14) are used, the master drive will be changed immediately if the feedback generates an 'Error'.

Change Timer [395] When the time set here is elapsed, the master drive will be changed. This function is only active if Select Drive [393]=All and Change Cond [394]= Timer/ Both. Communication information Drives on Change [396] If a master drive is changed according to the timer func- tion (Change Condition=Timer/Both [394]), it is possi- ble to leave additional pumps running during the change operation. With this function the change opera- tion will be as smooth as possible. The maximum number to be programmed in this menu depends on the number of additional drives. Example: If the number of drives is set to 6, the maximum value will be 4. This function is only active if Select Drive [393]=All. Communication information

395 Change Timer Stp A 50h

394 Change Cond Stp A Both

396 Drives on Ch Stp A 0

Source menu settings and communication mappings with same-page notes and cross-page continuations. Defaults kept separate from display examples. Raw values and shared physical extents retained. Not engineering approval.

395 Change Timer metadata — PDF page 108

Source row Property or applicable mode Source value
1 Default: 50 h
2 Range: 1-3000 h

394 Change Condition metadata — PDF page 108

Source row Property or applicable mode Source value
1 Default: Both

394 Change Condition selections — PDF page 108

Source row Selection Integer code Description
1 Stop 0 The Runtime of the master drive determines when a master drive has to be changed. The change will only take place after a: - Power Up - Stop - Standby condition - Trip condition.
2 Timer 1 The master drive will be changed if the timer setting in Change Timer [395] has elapsed. The change will take place immediately. So during operation the additional pumps will be stopped temporarily, the 'new' master will be selected according to the Run Time and the additional pumps will be started again. It is possible to leave 2 pumps running during the change operation. This can be set with Drives on Change [396].
3 Both 2 The master drive will be changed if the timer setting in Change Timer [395] has elapsed. The 'new' master will be selected according to the elapsed Run Time. The change will only take place after a: - Power Up - Stop - Standby condition. - Trip condition.

395 communication — PDF page 108

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43165
2 Profibus slot/index 169/69
3 Fieldbus format UInt, 1=1 h
4 Modbus format UInt, 1=1 h

396 Drives on Change metadata — PDF page 108

Source row Property or applicable mode Source value
1 Default: 0
2 Range: 0 to (the number of drives - 2)

394 communication — PDF page 108

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43164
2 Profibus slot/index 169/68
3 Fieldbus format UInt
4 Modbus format UInt

396 communication — PDF page 108

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43166
2 Profibus slot/index 169/70
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Pump upper lower bands and delay — page 109

Manual reference: physical PDF page 109. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Upper Band [397] If the speed of the master drive comes into the upper band, an additional drive will be added after a delay time that is set in start delay [399]. Communication information Example: Max Speed = 1500 rpm Min Speed = 300 rpm Upper Band = 10% Start delay will be activated: Range = Max Speed to Min Speed = 1500–300 = 1200 rpm 10% of 1200 rpm = 120 rpm Start level = 1500–120 = 1380 rpm Fig. 83 Upper band Lower Band [398] If the speed of the master drive comes into the lower band an additional drive will be stopped after a delay time. This delay time is set in the parameter Stop Delay [39A].

Communication information Example: Max Speed = 1500 rpm Min Speed = 300 rpm Lower Band = 10% Stop delay will be activated: Range = Max Speed - Min Speed = 1500–300 = 1200 rpm 10% of 1200 rpm = 120 rpm Start level = 300 + 120 = 420 rpm Fig. 84 Lower band Start Delay [399] This delay time must have elapsed before the next pump is started. A delay time prevents the nervous switching of pumps. Communication information

Speed Max/Min; Upper band; next pump starts; Start Delay[399]; Flow/Pressure. Original curves retained.

Speed Max/Min; top pump stops; Lower band; Stop Delay[39A]; Flow/Pressure. Original curves retained.

397 Upper Band Stp A 10%

399 Start Delay Stp A 0s

398 Lower Band Stp A 10%

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

Default: 10%

398 communication — PDF page 109

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43168
2 Profibus slot/index 169/72
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

397 Upper Band metadata — PDF page 109

Source row Property Source value
1 Default: 10%
2 Range: 0-100% of total min speed to max speed

397 communication — PDF page 109

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43167
2 Profibus slot/index 169/71
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

399 Start Delay metadata — PDF page 109

Source row Property Source value
1 Default: 0 s
2 Range: 0-999 s

399 communication — PDF page 109

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43169
2 Profibus slot/index 169/73
3 Fieldbus format Long, 1=1s
4 Modbus format EInt

Manual — Pump band limits and start settling — page 110

Manual reference: physical PDF page 110. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Stop Delay [39A] This delay time must have elapsed before the 'top' pump is stopped. A delay time prevents the nervous switching of pumps. Communication information Upper Band Limit [39B] If the speed of the pump reaches the upper band limit, the next pump is started immediately without delay. If a start delay is used this delay will be ignored. Range is between 0%, equalling max speed, and the set percent- age for the UpperBand [397]. Communication information Fig. 85 Upper band limit

Lower Band Limit [39C] If the speed of the pump reaches the lower band limit, the 'top' pump is stopped immediately without delay. If a stop delay is used this delay will be ignored. Range is from 0%, equalling min speed, to the set percentage for the Lower Band [398]. Communication information Fig. 86 Lower band limit Settle Time Start [39D] The settle start allows the process to settle after a pump is switched on before the pump control contin- ues. If an additional pump is started D.O.L. (Direct On Line) or Y/ Δ , the flow or pressure can still fluctuate due to the 'rough' start/stop method. This could cause unnecessary starting and stopping of additional pumps. During the Settle start: • PID controller is off. • The speed is kept at a fixed level after adding a pump.

Speed Max/Min; Upper band; Upper band limit[39B]; next pump starts immediately; Start Delay[399]; Flow/Pressure.

Speed Max/Min; top pump stops immediately; Lower band; Lower band limit[39C]; Stop Delay[39A]; Flow/Pressure.

39A Stop Delay Stp A 0s

39C Low Band Lim Stp A 0%

39B Upp Band Lim Stp A 0%

39D Settle Start Stp A 0s

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

Default: 0 s

39A Stop Delay metadata — PDF page 110

Source row Property Source value
1 Default: 0 s
2 Range: 0-999 s

39C Lower Band Limit metadata — PDF page 110

Source row Property Source value
1 Default: 0%
2 Range: 0 to Lower Band level. 0% (=min speed) means that he Limit function is switched off.

39A communication — PDF page 110

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43170
2 Profibus slot/index 169/74
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

39C communication — PDF page 110

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43172
2 Profibus slot/index 169/76
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

39B Upper Band Limit metadata — PDF page 110

Source row Property Source value
1 Default: 0%
2 Range: 0 to Upper Band level. 0% (=max speed) means that the Limit function is switched off.

39B communication — PDF page 110

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43171
2 Profibus slot/index 169/75
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

Manual — Transition speed and stop settling — page 111

Manual reference: physical PDF page 111. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Transition Speed Start [39E] The transition speed start is used to minimize a flow/ pressure overshoot when adding another pump. When an additional pump needs to be switched on, the mas- ter pump will slow down to the set transition speed start value, before the additional pump is started. The setting depends on the dynamics of both the master drive and the additional drives. The transition speed is best set by trial and error. In general: • If the additional pump has 'slow' start/stop dynam- ics, then a higher transition speed should be used. • If the additional pump has 'fast' start/stop dynam- ics, then a lower transition speed should be used. Communication information Example Max Speed = 1500 rpm Min Speed = 200 rpm TransS Start = 60% When an additional pump is needed, the speed will be controlled down to min speed + (60% x (1500 rpm - 200 rpm)) = 200 rpm + 780 rpm = 980 rpm. When this speed is reached, the additional pump with the lowest run time hours will be switched on.

Fig. 87 Transition speed start Fig. 88 Effect of transition speed Settle Time Stop [39F] The settle stop allows the process to settle after a pump is switched off before the pump control contin- ues. If an additional pump is stopped D.O.L. (Direct On Line) or Y/ Δ , the flow or pressure can still fluctuate due to the 'rough' start/stop method. This could cause unnecessary starting and stopping of additional pumps. During the Settle stop: • PID controller is off. • the speed is kept at a fixed level after stopping a pump Communication information

Speed Actual/Trans/Min; Switch on procedure starts; Additional pump; Master pump; Actual start command of next pump (RELAY); Flow/Pressure.

Flow/Pressure; Transition speed decreases overshoot; Time. No numerical points inferred.

39E TransS Start Stp A 60%

39F Settle Stop Stp A 0s

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

39D communication continuation — PDF page 111

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43173
2 Profibus slot/index 169/77
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

39E Transition Speed Start metadata — PDF page 111

Source row Property Source value
1 Default: 60%
2 Range: 0-100% of total min speed to max speed

39E communication — PDF page 111

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43174
2 Profibus slot/index 169/78
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

39F Settle Stop metadata — PDF page 111

Source row Property Source value
1 Default: 0 s
2 Range: 0–999 s

39F communication — PDF page 111

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43175
2 Profibus slot/index 169/79
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

Manual — Stop transition and runtime counters — page 112

Manual reference: physical PDF page 112. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Transition Speed Stop [39G] The transition speed stop is used to minimize a flow/ pressure overshoot when shutting down an additional pump. The setting depends on the dynamics of both the master drive and the additional drives. In general: • If the additional pump has 'slow' start/stop dynam- ics, then a higher transition speed should be used. • If the additional pump has 'fast' start/stop dynam- ics, then a lower transition speed should be used. Communication information Example Max Speed = 1500 rpm Min Speed = 200 rpm TransS Start = 60% When less additional pumps are needed, the speed will be controlled up to min speed + (60% x (1500 rpm - 200 rpm)) = 200 rpm + 780 rpm = 980 rpm. When this speed is reached, the additional pump with the highest run time hours will be switched off. Fig. 89 Transition speed stop

Run Times 1-6 [39H] to [39M] Communication information Reset Run Times 1-6 [39H1] to [39M1] Communication information

Speed Max/Trans/Actual/Min; Actual shut down of pump; Master pump; Additional pump; Switch off procedure starts; Flow/Pressure.

39H Run Time 1 Stp A h:mm:ss

39G TransS Stop Stp A 60%

39H1 Rst Run Tm1 Stp A No

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

39H–39M Run Time metadata — PDF page 112

Source row Property Source value
1 Unit: h:mm:ss (hours:minutes:seconds)
2 Range: 0:00:00–262143:59:59

39H–39M communication — PDF page 112

Source row Property Source value
1 Modbus Instance no/ DeviceNet no: 31051 : 31052 : 31053(hr:min:sec) 31054 : 31055: 31056(hr:min:sec) 31057 : 31058: 31059(hr:min:sec) 31060 : 31061: 31062(hr:min:sec) 31063 : 31064: 31065(hr:min:sec) 31066 : 31067: 31068(hr:min:sec)
2 Profibus slot/index 121/195, 121/196, 121/197, 121/198, 121/199, 121/200, 121/201, 121/202, 121/203, 121/204, 121/205, 121/206, 121/207, 121/208, 121/209, 121/210, 121/211, 121/212
3 Fieldbus format Long, 1=1h/m/s
4 Modbus format EInt, 1=1h/m/s

39G Transition Speed Stop metadata — PDF page 112

Source row Property Source value
1 Default: 60%
2 Range: 0-100% of total min speed to max speed

39G communication — PDF page 112

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43176
2 Profibus slot/index 169/80
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

39H1–39M1 Reset Run Time metadata — PDF page 112

Source row Property Source value
1 Default: No

39H1–39M1 Reset Run Time selections — PDF page 112

Source row Selection Integer code Description
1 No 0 ⟦blank source cell⟧
2 Yes 1 ⟦blank source cell⟧

39H1–39M1 communication — PDF page 112

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 38–43, pump 1 -6
2 Profibus slot/index 0/37–0/42
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Pump status backup and crane enable — page 113

Manual reference: physical PDF page 113. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Pump Status [39N] Number backup/reserve [39P] Sets the number of pumps used for backup/reserve which in normal conditions can not be selected. This function can be used for increasing redundancy in the pump system by having pumps in reserve that can be activated when some pumps indicate fault or are shut off for maintenance. Communication information

11.3.11 Crane Option [3A0] Settings for the optional Crane board (Crane Remote Input/Output card). See also the Crane option instruc- tion manual. NOTE: This menu is only visible if the crane board is connected to the AC drive. Crane enable [3A1] When the crane option board is connected, it is possi- ble to (de)activate the crane option board inputs. NOTE: Deviation function is active even if [3A1]=off. Communication information Control [3A2] To select the type of crane joystick control. Communication information

39N Pump 123456 / Stp A / OCD. Example status illustration; letters defined by adjacent table.

3A1 Crane enable Stp A On

39P No of Backup Stp A 0

3A2 Control Stp A 4-Speeds

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

39N Status indications — PDF page 113

Source row Indication Description
1 C Control, master pump, only when alternating master is used
2 D Direct control
3 O Pump is off
4 E Pump error

3A1 Crane Enable metadata — PDF page 113

Source row Property Source value
1 Default: Off

3A1 Crane Enable selections — PDF page 113

Source row Selection Integer code Description
1 Off 0 Crane option board deactivated
2 On 1 Crane option board activated

39P Number of Backup metadata — PDF page 113

Source row Property Source value
1 Default: 0
2 Range: 0-3

3A1 communication — PDF page 113

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43181
2 Profibus slot/index 169/85
3 Fieldbus format UInt
4 Modbus format UInt

39P communication — PDF page 113

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43177
2 Profibus slot/index 169/81
3 Fieldbus format UInt
4 Modbus format UInt

3A2 Crane Control metadata — PDF page 113

Source row Property Source value
1 Default: 4-Speeds

3A2 Crane Control selections — PDF page 113

Source row Selection Integer code Description
1 4-Speeds 0 4-Speed joystick
2 3-Pos 1 3-Position switch
3 Analogue 2 Analogue joystick

3A2 communication — PDF page 113

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43182
2 Profibus slot/index 169/86
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Crane relays and crawling speeds — page 114

Manual reference: physical PDF page 114. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Crane Relay CR1 [3A3] Crane Relay CR1 on the Crane option board is fixed to the No Trip function. Communication information Crane Relay CR2 [3A4] To select the function of Crane Relay CR2 on the Crane option board. Same selections as for the relays on the control board. Communication information Pre Limit Switch Speed [3A5] To set the speed used when Pre-Limit Switch on the Crane option board is active.

Communication information Crawl speed H/R [3A6] To set the speed used when crawling (min. speed) dur- ing a hoisting operation. Activated with input A1, Crawl H/R=Start in positive speed direction Communication information Crawl speed L/L [3A7] To set the speed used when crawling (min. speed) dur- ing lowering operation. Activated with input A2, Crawl L/ L=Start in negative speed direction. Communication information

3A3 Crane Relay1 Stp A No Trip

3A6 CrawlSpd H/R Stp A rpm

3A4 Crane Relay2 Stp A Brake

3A7 CrawlSpd L/L Stp A rpm

3A5 PreLimSwSpd Stp A rpm

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

3A5 communication from lower left — PDF page 114

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43185
2 Profibus slot/index 169/89
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

3A3 Crane Relay1 metadata — PDF page 114

Source row Property Source value
1 Default: No Trip
2 Selections Fixed to No Trip

3A3 communication — PDF page 114

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43183
2 Profibus slot/index 169/87
3 Fieldbus format UInt
4 Modbus format UInt

3A6 Crawl Speed H R metadata — PDF page 114

Source row Property Source value
1 Default: 0
2 Range: 0 – 4 x Sync speed

3A6 communication — PDF page 114

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43189
2 Profibus slot/index 169/93
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

3A4 Crane Relay2 metadata — PDF page 114

Source row Property Source value
1 Default: Brake
2 Selections Same selections as for the relays on the control board

3A4 communication — PDF page 114

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43184
2 Profibus slot/index 169/88
3 Fieldbus format UInt
4 Modbus format UInt

3A7 communication — PDF page 114

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43190
2 Profibus slot/index 169/94
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

3A5 Pre Limit Switch Speed metadata — PDF page 114

Source row Property Source value
1 Default: 0 rpm
2 Range: 0 – 4 x Motor Sync speed

Manual — Crane speeds deviation and field weakening — page 115

Manual reference: physical PDF page 115. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Speed 2 [3A8] To set the speed used when the input B1, Speed 2 on the Crane option board is active. Communication information Speed 3 [3A9] To set the speed used when the input B2, Speed 3 on the Crane option board is active. Communication information Speed 4 [3AA] To set the speed used when the input B3, Speed 4 on the Crane option board is active. Communication information

Deviation Band width [3AB] To define the speed deviation window within which the AC drive is in control of the motor. Communication information Deviation Time [3AC] To set the time during which the deviation condition must be active, before the inverter trips. Communication information LAFS Load [3AD] To set the load below which the VFB/V33 goes into load dependent field weakening operation. Communication information

3A8 Speed 2 Stp A rpm

3AB Dev Bandwidt Stp A rpm

3A9 Speed 3 Stp A rpm

3AC Dev. Time Stp A s

3AA Speed 4 Stp A rpm

3AD LAFS Load Stp A Off

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

3A8 Speed2 metadata — PDF page 115

Source row Property Source value
1 Default: 0
2 Range: 0 – 4 x Sync speed

3A8 communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43186
2 Profibus slot/index 169/90
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

3AB communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43191
2 Profibus slot/index 169/95
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

3A9 Speed3 metadata — PDF page 115

Source row Property Source value
1 Default: 0
2 Range: 0 – 4 x Motor Sync speed

3AC Deviation Time metadata — PDF page 115

Source row Property Source value
1 Default: 0.10 s
2 Range: 0.05 – 1 s

3A9 communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43187
2 Profibus slot/index 169/91
3 Fieldbus format Int
4 Modbus format Int

3AC communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43192
2 Profibus slot/index 169/96
3 Fieldbus format Long, 1=0.001 s
4 Modbus format EInt

3AD LAFS Load metadata — PDF page 115

Source row Property Source value
1 Default: Off

3AD LAFS Load selections — PDF page 115

Source row Selection Integer code Description
1 Off 0 Off
2 1–100 1–100 1% – 100%

3AA communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43188
2 Profibus slot/index 169/92
3 Fieldbus format Int
4 Modbus format Int

3AD communication — PDF page 115

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43193
2 Profibus slot/index 169/97
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

Manual — Crane brake acknowledgement and load alarms — page 116

Manual reference: physical PDF page 116. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

When set to OFF, the load dependent field weakening function is switched off. CRIO N input function [3AG] Sets the function of CRIO/Crane I/O interface N(Null) input. Communication information Note: Brake Acknowledge via Crane I/O has priority (and overrules) Brake acknowledge via control board I/O ([521 DigIn1] - [528 Dig In8]).

11.4 Load Monitor and Process Protection [400] 11.4.1 Load Monitor [410] The monitor functions enable the AC drive to be used as a load monitor. Load monitors are used to protect machines and processes against mechanical overload and underload, e.g. a conveyer belt or screw conveyer jamming, belt failure on a fan and a pump dry running. See explanation in section 7.5, page 40. Alarm Select [411] Selects the types of alarms that are active. Communication information Alarm Trip [412] Selects which alarm must cause a trip to the AC drive. Communication information

3AG Crane N Func Stp A Zero Pos

411 Alarm Select Stp A Off

412 Alarm trip Stp A Off

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

3AG Crane N Function metadata — PDF page 116

Source row Property Source value
1 Default: Zero Pos

3AG Crane N Function selections — PDF page 116

Source row Selection Integer code Description
1 Off 0 N input not used
2 Zero Pos 1 N input used for joystick zero position indication.
3 Brk Ackn 2 N input used for Brake Acknowledge. see page 90.

411 Alarm Select metadata — PDF page 116

Source row Property Source value
1 Default: Off

411 Alarm Select selections — PDF page 116

Source row Selection Integer code Description
1 Off 0 No alarm functions active.
2 Min 1 Min Alarm active. The alarm output func- tions as an underload alarm.
3 Max 2 Max Alarm active. The alarm output func- tions as an overload alarm.
4 Max+Min 3 Both Max and Min alarm are active. The alarm outputs function as overload and underload alarms.

3AG communication — PDF page 116

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43194
2 Profibus slot/index 169/98
3 Fieldbus format UInt
4 Modbus format UInt

411 communication — PDF page 116

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43321
2 Profibus slot/index 169/225
3 Fieldbus format UInt
4 Modbus format UInt

412 Alarm Trip metadata — PDF page 116

Source row Property Source value
1 Default: Off
2 Selection: Same as in menu [411]

412 communication — PDF page 116

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43322
2 Profibus slot/index 169/226
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Ramp alarm delay and load curve types — page 117

Manual reference: physical PDF page 117. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Ramp Alarm [413] This function inhibits the (pre) alarm signals during acceleration/deceleration of the motor to avoid false alarms. Communication information Alarm Start Delay [414] This parameter is used if, for example, you want to over- ride an alarm during the start-up procedure. Sets the delay time after a run command, after which the alarm may be given. • If Ramp Alarm=On. The start delay begins after a RUN command. • If Ramp Alarm=Off. The start delay begins after the acceleration ramp. Communication information

Load Type [415] In this menu you select monitor type according to the load characteristic of your application. By selecting the required monitor type, the overload and underload alarm function can be optimized according to the load characteristic. When the application has a constant load over the whole speed range, i.e. extruder or screw compressor, the load type can be set to basic. This type uses a sin- gle value as a reference for the nominal load. This value is used for the complete speed range of the AC drive. The value can be set or automatically measured. See Autoset Alarm [41A] and Normal Load [41B] about set- ting the nominal load reference. The load curve mode uses an interpolated curve with 9 load values at 8 equal speed intervals. This curve is populated by a test run with a real load. This can be used with any smooth load curve including constant load. Fig. 90 Communication information

Load; Max Alarm; Basic; Min Alarm; Load curve; Speed. Source illustrative graph; no numeric interpolation.

413 Ramp Alarm Stp A Off

414 Start Delay Stp A 2s

415 Load Type Stp A Basic

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

413 Ramp Alarm metadata — PDF page 117

Source row Property Source value
1 Default: Off

413 Ramp Alarm selections — PDF page 117

Source row Selection Integer code Description
1 Off 0 (Pre) alarms are inhibited during accelera- tion/deceleration.
2 On 1 (Pre) alarms active during acceleration/ deceleration.

413 communication — PDF page 117

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43323
2 Profibus slot/index 169/227
3 Fieldbus format UInt
4 Modbus format UInt

414 Start Delay metadata — PDF page 117

Source row Property Source value
1 Default: 2 s
2 Range: 0-3600 s

415 Load Type metadata — PDF page 117

Source row Property Source value
1 Default: Basic

415 Load Type selections — PDF page 117

Source row Selection Integer code Description
1 Basic 0 Uses a fixed maximum and minimum load level over the full speed range. Can be used in situations where the torque is independ- ent of the speed.
2 Load Curve 1 Uses the measured actual load characteristic of the process over the speed range.

414 communication — PDF page 117

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43324
2 Profibus slot/index 169/228
3 Fieldbus format Long, 1=1 s
4 Modbus format EInt

415 communication — PDF page 117

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43325
2 Profibus slot/index 169/229
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Overload and underload alarm margins — page 118

Manual reference: physical PDF page 118. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Max Alarm [416] Max Alarm Margin [4161] With load type Basic, [415], used the Max Alarm Margin sets the band above the Normal Load, [41B], menu that does not generate an alarm. With load type Load Curve, [415], used the Max Alarm Margin sets the band above the Load Curve, [41C], that does not generate an alarm. The Max Alarm Margin is a percentage of nomi- nal motor torque. Communication information Max Alarm delay [4162] Sets the delay time between the first occurrence of max alarm condition and after when the alarm is given. Communication information Max Pre Alarm [417] Max Pre AlarmMargin [4171] With load type Basic, [415], used the Max Pre-Alarm Margin sets the band above the Normal Load, [41B], menu that does not generate a pre-alarm. With load type Load Curve, [415], used the Max Pre-Alarm Margin sets the band above the Load Curve, [41C], that does not generate a pre-alarm. The Max Pre-Alarm Margin is a percentage of nominal motor torque.

Communication information Max Pre Alarm delay [4172] Sets the delay time between the first occurrence of max pre alarm condition and after when the alarm is given. Communication information Min Pre Alarm [418] Min Pre Alarm Margin [4181] With load type Basic, [415], used the Min Pre-Alarm Margin sets the band under the Normal Load, [41B], menu that does not generate a pre-alarm. With load type Load Curve, [415], used the Min Pre-Alarm Margin sets the band under the Load Curve, [41C], that does not generate a pre-alarm. The Min Pre-Alarm Margin is a percentage of nominal motor torque. Communication information

4171 MaxPreAlMar / Stp A /10%. Metadata continues in upper right column.

4161 MaxAlarmMar Stp A 15%

4172 MaxPreAlDel Stp A 0.1s

4162 MaxAlarmDel Stp A 0.1s

4181 MinPreAlMar Stp A 10%

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

4171 Max Pre Alarm Margin metadata continuation — PDF page 118

Source row Property Source value
1 Default: 10%
2 Range: 0–400%

4171 communication — PDF page 118

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43327
2 Profibus slot/index 169/231
3 Fieldbus format Long, 1=0.1%
4 Modbus format EInt

4161 Max Alarm Margin metadata — PDF page 118

Source row Property Source value
1 Default: 15%
2 Range: 0–400%

4172 Max Pre Alarm Delay metadata — PDF page 118

Source row Property Source value
1 Default: 0.1 s
2 Range: 0–90 s

4161 communication — PDF page 118

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43326
2 Profibus slot/index 169/230
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

4172 communication — PDF page 118

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43331
2 Profibus slot/index 169/235
3 Fieldbus format Long, 1=0.1 s
4 Modbus format EInt

4162 Max Alarm Delay metadata — PDF page 118

Source row Property Source value
1 Default: 0.1 s
2 Range: 0-90 s

4162 communication — PDF page 118

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43330
2 Profibus slot/index 169/234
3 Fieldbus format Long, 1=0.1 s
4 Modbus format EInt

4181 Min Pre Alarm Margin metadata — PDF page 118

Source row Property Source value
1 Default: 10%
2 Range: 0-400%

4181 communication — PDF page 118

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43328
2 Profibus slot/index 169/232
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

Manual — Alarm response delays and autoset warnings — page 119

Manual reference: physical PDF page 119. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Min Pre Alarm Response delay [4182] Sets the delay time between the first occurrence of min pre alarm condition and after when the alarm is given. Communication information Min Alarm [419] Min Alarm Margin [4191] With load type Basic, [415], used the Min Alarm Margin sets the band under the Normal Load, [41B], menu that does not generate an alarm. With load type Load Curve, [415], used the Min Alarm Margin sets the band under the Load Curve, [41C], that does not generate an alarm. The Max Alarm Margin is a percentage of nomi- nal motor torque. Communication information

Min Alarm Response delay [4192] Sets the delay time between the first occurrence of min alarm condition and after when the alarm is given. Communication information Autoset Alarm [41A] The Autoset Alarm function can measure the nominal load that is used as reference for the alarm levels. If the selected Load Type [415] is Basic it copies the load the motor is running with to the menu Normal Load [41B]. The motor must run on the speed that generates the load that needs to be recorded. If the selected Load Type [415] is Load Curve it performs a test-run and pop- ulates the Load Curve [41C] with the found load values. WARNING! When autoset does a test run the motor and application/machine will ramp up to maximum speed. NOTE: The motor must be running for the Autoset Alarm function to succeed. A not running motor generates a “Failed!” message. Communication information

4182 MinPreAlDel Stp A 0.1s

4192 MinAlarmDel Stp A 0.1s

4191 MinAlarmMar Stp A 15%

41A AutoSet Alrm Stp A No

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

4182 Min Pre Alarm Delay metadata — PDF page 119

Source row Property Source value
1 Default: 0.1 s
2 Range: 0-90 s

4182 communication — PDF page 119

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43332
2 Profibus slot/index 169/236
3 Fieldbus format Long, 1=0.1 s
4 Modbus format EInt

4192 communication — PDF page 119

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43333
2 Profibus slot/index 169/237
3 Fieldbus format Long, 1=0.1 s
4 Modbus format EInt

4191 Min Alarm Margin metadata — PDF page 119

Source row Property Source value
1 Default: 15%
2 Range: 0-400%

4191 communication — PDF page 119

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43329
2 Profibus slot/index 169/233
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

41A Autoset Alarm metadata — PDF page 119

Source row Property Source value
1 Default: No

41A Autoset Alarm selections — PDF page 119

Source row Selection Integer code Description
1 No 0 ⟦blank source cell⟧
2 Yes 1 ⟦blank source cell⟧

41A communication — PDF page 119

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43334
2 Profibus slot/index 169/238
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Normal load curve samples and communication — page 120

Manual reference: physical PDF page 120. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

The default set levels for the (pre)alarms are: These default set levels can be manually changed in menus [416] to [419]. After execution the message “Autoset OK!” is displayed for 1s and the selection reverts to “No”. Normal Load [41B] Set the level of the normal load. The alarm or pre alarm will be activated when the load is above/under normal load ± margin. NOTE: 100% Torque means: INOM= IMOT. The maximum depends on the motor current and AC drive max current settings, but the absolute maximum adjustment is 400%. Communication information Load Curve [41C] The load curve function can be used with any smooth load curve. The curve can be populated with a test-run or the values can be entered or changed manually. Load Curve 1-9 [41C1]-[41C9] The measured load curve is based on 9 stored sam- ples. The curve starts at minimum speed and ends at maximum speed, the range in between is divided into 8 equal steps. The measured values of each sample are displayed in [41C1] to [41C9] and can be adapted man- ually. The value of the 1st sampled value on the load curve is displayed.

Communication information NOTE: The speed values depend on the Min- and Max Speed values. they are read only and cannot be changed. Fig. 91

Min Speed;Max Speed;vertical ticks0,0.5,1;Speed ticks0,0.2,0.4,0.6,0.8,1. Legend Measured load samples;Min-max tolerance band;Max alarm limit;Min alarm limit. No interpolated values or unspecified vertical unit inferred.

41B Normal Load Stp A 100%

41C1 Load Curve1 Stp A 0rpm 100%

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

Alarm default formulas — PDF page 120

Source row Condition Alarm Formula
1 Overload Max Alarm menu [4161] + [41B]
2 Overload Max Pre Alarm menu [4171] + [41B]
3 Underload Min Pre Alarm menu [41B] - [4181]
4 Underload Min Alarm menu [41B] - [4191]

41C1–41C9 communication — PDF page 120

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43336%, 43337 rpm, 43338%, 43339 rpm, 43340%, 43341 rpm, 43342%, 43343 rpm, 43344%, 43345 rpm, 43346%, 43347 rpm, 43348%, 43349 rpm, 43350%, 43351 rpm, 43352%, 43353 rpm
2 Profibus slot/index 169/240, 169/242, 169/244, 169/246, 169/248, 169/250, 169/252, 169/254, 170/1
3 Fieldbus format Long
4 Modbus format EInt

41B Normal Load metadata — PDF page 120

Source row Property Source value
1 Default: 100%
2 Range: 0-400% of max torque

41B communication — PDF page 120

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43335
2 Profibus slot/index 169/239
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

41C1–41C9 Load Curve metadata — PDF page 120

Source row Property Source value
1 Default: 100%
2 Range: 0–400% of max torque

Manual — Low voltage stalled rotor and missing motor protection — page 121

Manual reference: physical PDF page 121. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.4.2 Process Protection [420] Submenu with settings regarding protection functions for the AC drive and the motor. Low Voltage Override [421] If a dip in the mains supply occurs and the low voltage override function is enabled, the AC drive will automati- cally decrease the motor speed to keep control of the application and prevent an under voltage trip until the input voltage rises again. Therefore the rotating energy in the motor/load is used to keep the DC link voltage level at the override level, for as long as possible or until the motor comes to a standstill. This is dependent on the inertia of the motor/load combination and the load of the motor at the time the dip occurs, see Fig. 92. Communication information Fig. 92 Low voltage override NOTE: During the low voltage override the LED trip/limit blinks.

Rotor locked [422] With the rotor locked function enabled, the AC drive will protect the motor and application when this is stalled whilst increasing the motor speed from standstill. This protection will coast the motor to stop and indicate a fault when the Torque Limit has been active at very low speed for more than 5 seconds. Communication information Motor lost [423] With the motor lost function enabled, the AC drive is able to detect a fault in the motor circuit: motor, motor cable, thermal relay or output filter. Motor lost will cause a trip, and the motor will coast to standstill, when a missing motor phase is detected during a period of 5 s. Communication information

DC link voltage; Override level;Low Volt. level;t;Speed;t. Original curves retained.

422 Rotor locked Stp A Off

421 Low Volt OR Stp A On

423 Motor lost Stp A Off

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

422 Rotor Locked metadata — PDF page 121

Source row Property Source value
1 Default: Off

422 Rotor Locked selections — PDF page 121

Source row Selection Integer code Description
1 Off 0 No detection
2 On 1 AC drive will trip when locked rotor is detected. Trip message “Locked Rotor”.

421 Low Voltage Override metadata — PDF page 121

Source row Property Source value
1 Default: On

421 Low Voltage Override selections — PDF page 121

Source row Selection Integer code Description
1 Off 0 At a voltage dip the low voltage trip will protect.
2 On 1 At mains dip, AC drive ramps down until voltage rises.

422 communication — PDF page 121

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43362
2 Profibus slot/index 170/11
3 Fieldbus format UInt
4 Modbus format UInt

421 communication — PDF page 121

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43361
2 Profibus slot/index 170/10
3 Fieldbus format UInt
4 Modbus format UInt

423 Motor Lost selections — PDF page 121

Source row Selection Integer code Description
1 Off 0 Function switched off to be used if no motor or very small motor connected.
2 Trip 1 AC drive will trip when the motor is disconnected. Trip message “Motor Lost”.

423 communication — PDF page 121

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43363
2 Profibus slot/index 170/12
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Overvoltage control and analogue input function — page 122

Manual reference: physical PDF page 122. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Overvolt control [424] Used to switch off the overvoltage control function when only braking by brake chopper and resistor is required. The overvoltage control function, limits the braking torque so that the DC link voltage level is con- trolled at a high, but safe, level. This is achieved by lim- iting the actual deceleration rate during stopping. In case of a defect at the brake chopper or the brake resistor the AC drive will trip for “Overvoltage” to avoid a fall of the load e.g. in crane applications. NOTE: Overvoltage control should not be activated if brake chopper is used. Communication information

11.5 I/Os and Virtual Connections [500] Main menu with all the settings of the standard inputs and outputs of the AC drive. 11.5.1 Analogue Inputs [510] Submenu with all settings for the analogue inputs. AnIn1 Function [511] Sets the function for Analogue input 1. Scale and range are defined by AnIn1 Advanced settings [513]. Communication information NOTE: When AnInX Func=Off, the connected signal will still be available for Comparators [610]. Adding analogue inputs If more then one analogue input is set to the same function, the values of the inputs can be added together. In the following examples we assume that Process Source [321] is set to Speed. Example 1: Add signals with different weight (fine tun- ing). Signal on AnIn1 = 10 mA Signal on AnIn2 = 5 mA [511] AnIn1 Function = Process Ref. [512] AnIn1 Setup = 4-20 mA [5134] AnIn1 Function Min = Min (0 rpm) [5136] AnIn1 Function Max = Max (1500 rpm) [5138] AnIn1 Operation = Add+ [514] AnIn2 Function = Process Ref.

424 Over Volt Ctl Stp A On

511 AnIn1 Fc Stp A Process Ref

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

424 Overvoltage Control metadata — PDF page 122

Source row Property Source value
1 Default: On

424 Overvoltage Control selections — PDF page 122

Source row Selection Integer code Description
1 On 0 Overvoltage control activated
2 Off 1 Overvoltage control off

511 AnIn1 Function metadata — PDF page 122

Source row Property Source value
1 Default: Process Ref

511 AnIn1 Function selections — PDF page 122

Source row Selection Integer code Description
1 Off 0 Input is not active
2 Max Speed 1 The input acts as an upper speed limit.
3 Max Torque 2 The input acts as an upper torque limit.
4 Process Val 3 The input value equals the actual process value (feedback) and is compared to the reference signal (set point) by the PID controller, or can be used to display and view the actual process value.
5 Process Ref 4 Reference value is set for control in process units, see Process Source [321] and Process Unit [322].

424 communication — PDF page 122

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43364
2 Profibus slot/index 170/13
3 Fieldbus format UInt
4 Modbus format UInt

511 communication — PDF page 122

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43201
2 Profibus slot/index 169/105
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue arithmetic examples and input setup — page 123

Manual reference: physical PDF page 123. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

[515] AnIn2 Setup = 4-20 mA [5164] AnIn2 Function Min = Min (0 rpm) [5166] AnIn2 Function Max = User defined [5167] AnIn2 Value Max = 300 rpm [5168] AnIn2 Operation = Add+ Calculation: AnIn1 = (10-4) / (20-4) x (1500-0) + 0 = 562.5 rpm AnIn2 = (5-4) / (20-4) x (300-0) + 0 = 18.75 rpm The actual process reference will be: +562.5 + 18.75 = 581 rpm Analogue Input Selection via Digital Inputs: When two different external Reference signals are used, e.g. 4-20mA signal from control centre and a 0- 10 V locally mounted potentiometer, it is possible to switch between these two different analogue input sig- nals via a Digital Input set to “AnIn Select”. AnIn1 is 4-20 mA AnIn2 is 0-10 V DigIn3 is controlling the AnIn selection; HIGH is 4-20 mA, LOW is 0-10 V [511] AnIn1 Fc = Process Ref; set AnIn1 as reference signal input [512] AnIn1 Setup = 4-20mA; set AnIn1 for a current reference signal [513A] AnIn1 Enable = DigIn; set AnIn1 to be active when DigIn3 is HIGH [514] AnIn2 Fc = Process Ref; set AnIn2 as reference signal input [515] AnIn2 Setup = 0-10V; set AnIn2 for a voltage reference signal [516A] AnIn2 Enabl = !DigIn; set AnIn2 to be active when DigIn3 is LOW [523] DigIn3=AnIn; set DIgIn3 as input fot selection of AI reference Subtracting analogue inputs Example 2: Subtract two signals Signal on AnIn1 = 8 V Signal on AnIn2 = 4 V [511] AnIn1 Function = Process Ref. [512] AnIn1 Setup = 0-10 V [5134] AnIn1 Function Min = Min (0 rpm) [5136] AnIn1 Function Max = Max (1500 rpm) [5138] AnIn1 Operation = Add+ [514] AnIn2 Function = Process Ref. [515] AnIn2 Setup = 0-10 V [5164] AnIn2 Function Min = Min (0 rpm) [5166] AnIn2 Function Max = Max (1500 rpm) [5168] AnIn2 Operation = Sub- Calculation: AnIn1 = (8-0) / (10-0) x (1500-0) + 0 = 1200 rpm AnIn2 = (4-0) / (10-0) x (1500-0) + 0 = 600 rpm

The actual process reference will be: +1200 - 600 = 600 rpm AnIn1 Setup [512] The analogue input setup is used to configure the ana- logue input in accordance with the signal used that will be connected to the analogue input. With this selection the input can be determined as current (4-20 mA) or voltage (0-10 V) controlled input. Other selections are available for using a threshold (live zero), a bipolar input function, or a user defined input range. With a bipolar input reference signal, it is possible to control the motor in two directions. See Fig. 93. NOTE: The selection of voltage or current input is done with S1. When the switch is in voltage mode only the voltage menu items are selectable. With the switch in current mode only the current menu items are selectable. NOTE: For bipol function, input RunR and RunL needs to be active and Rotation, [219] must be set to “R+L”.

512 AnIn1 Setup Stp A 4-20mA

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

512 AnIn1 Setup metadata — PDF page 123

Source row Property Source value
1 Default: 4-20 mA
2 Dependent on Setting of switch S1

512 AnIn1 Setup selections — PDF page 123

Source row Selection Integer code Description
1 4–20mA 0 The current input has a fixed threshold (Live Zero) of 4 mA and controls the full range for the input signal. See Fig. 95.
2 0–20mA 1 Normal full current scale configuration of the input that controls the full range for the input signal. See Fig. 94.
3 User mA 2 The scale of the current controlled input, that controls the full range for the input sig- nal. Can be defined by the advanced AnIn Min and AnIn Max menus.
4 User Bipol mA 3 Sets the input for a bipolar current input, where the scale controls the range for the input signal. Scale can be defined in advanced menu AnIn Bipol.
5 0–10V 4 Normal full voltage scale configuration of the input that controls the full range for the input signal. See Fig. 94.
6 2–10V 5 The voltage input has a fixed threshold (Live Zero) of 2 V and controls the full range for the input signal. See Fig. 95.
7 User V 6 The scale of the voltage controlled input, that controls the full range for the input sig- nal. Can be defined by the advanced AnIn Min and AnIn Max menus.
8 User Bipol V 7 Sets the input for a bipolar voltage input, where the scale controls the range for the input signal. Scale can be defined in advanced menu AnIn Bipol.

Manual — Input signal scaling and switch dependencies — page 124

Manual reference: physical PDF page 124. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

NOTE: Always check the needed set up when the setting of S1 is changed; selection will not adapt automatically. Communication information Fig. 93 Fig. 94 Normal full-scale configuration Fig. 95 2–10 V/4–20 mA (Live Zero)

AnIn1 Advanced [513] NOTE: The different menus will automatically be set to either “mA” or “V”, based on the selection in AnIn 1 Setup [512]. AnIn1 Min [5131] Parameter to set the minimum value of the external reference signal. Only visible if [512] = User mA/V. Communication information AnIn1 Max [5132] Parameter to set the maximum value of the external reference signal. Only visible if [512] = User mA/V. Communication information Special function: Inverted reference signal If the AnIn minimum value is higher than the AnIn maximum value, the input will act as an inverted refer- ence input, see Fig. 96.

Speed n;100% above and100% below axis as printed;−10V;0;10V;20mA. No minus sign added to lower100%.

n;100%;Ref;0;10V;20mA;0–10V;0–20mA.

n;100%;Ref;0;2V;4mA;10V;20mA;2–10V;4–20mA.

513 AnIn1 Advan / Stp A; blank value illustration.

5131 AnIn1 Min Stp A 0V/4.00mA

5132 AnIn1 Max Stp 10.0V/20.00mA

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

512 communication continuation — PDF page 124

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43202
2 Profibus slot/index 169/106
3 Fieldbus format UInt
4 Modbus format UInt

5131 AnIn1 Min metadata — PDF page 124

Source row Property Source value
1 Default: 0 V/4.00 mA
2 Range: 0.00–20.00 mA 0–10.00 V

5131 communication — PDF page 124

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43203
2 Profibus slot/index 169/107
3 Fieldbus format Long
4 Modbus format EInt

5132 AnIn1 Max metadata — PDF page 124

Source row Property Source value
1 Default: 10.00 V/20.00 mA
2 Range: 0.00–20.00 mA 0–10.00 V

5132 communication — PDF page 124

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43204
2 Profibus slot/index 169/108
3 Fieldbus format Long
4 Modbus format EInt

Manual — Bipolar input and process minimum — page 125

Manual reference: physical PDF page 125. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 96 Inverted reference AnIn1 Bipol [5133] This menu is automatically displayed if AnIn1 Setup is set to User Bipol mA or User Bipol V. The window will automatically show mA or V range according to selected function. The range is set by changing the positive maximum value; the negative value is automatically adapted accordingly. Only visible if [512] = User Bipol mA/V. The inputs RunR and RunL input need to be active, and Rotation, [219], must be set to “R+L”, to operate the bipolar function on the analogue input. Communication information

AnIn1 Function Min [5134] With AnIn1 Function Min the physical minimum value is scaled to selected process unit. The default scaling is dependent of the selected function of AnIn1 [511]. Table 25 shows corresponding values for the min and max selections depending on the function of the ana- logue input [511]. Table 25 Communication information AnIn1 Function Value Min [5135] With AnIn1 Function ValMin you define a user-defined value for the signal. Only visible when user-defined is selected in menu [5134]. Communication information

n;100%;Invert AnIn Min > AnIn Max;Ref;0;10V. Original geometry retained.

5134 AnIn1 FcMin Stp A Min

5133 AnIn1 Bipol Stp A 10.00V/20.00mA

5135 AnIn1 VaMin Stp A 0.000

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

5134 AnIn1 Function Min metadata — PDF page 125

Source row Property Source value
1 Default: Min

5134 AnIn1 Function Min selections — PDF page 125

Source row Selection Integer code Description
1 Min 0 Min value
2 Max 1 Max value
3 User- defined 2 Define user value in menu [5135]

Table25 Analogue Input function limits — PDF page 125

Source row Function Min Value Max Value
1 Speed Min Speed [341] Max Speed [343]
2 Torque 0% Max Torque [351]
3 Process Ref Process Min [324] Process Max [325]
4 Process Value Process Min [324] Process Max [325]

5133 AnIn1 Bipolar metadata — PDF page 125

Source row Property Source value
1 Default: 10.00 V/20.00 mA
2 Range: 0.0–20.0 mA, 0.00–10.00 V

5134 communication — PDF page 125

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43206
2 Profibus slot/index 169/110
3 Fieldbus format UInt
4 Modbus format UInt

5133 communication — PDF page 125

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43205
2 Profibus slot/index 169/109
3 Fieldbus format Long
4 Modbus format EInt

5135 AnIn1 Value Min metadata — PDF page 125

Source row Property Source value
1 Default: 0.000
2 Range: -10000.000 – 10000.000

5135 communication — PDF page 125

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43541
2 Profibus slot/index 170/190
3 Fieldbus format Long, Speed 1=1 rpm Torque 1=1% Process val 1=0.001
4 Modbus format EInt

Manual — Input maximum operation and filtering — page 126

Manual reference: physical PDF page 126. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

AnIn1 Function Max [5136] With AnIn1 Function Max the physical maximum value is scaled to selected process unit. The default scaling is dependent of the selected function of AnIn1 [511]. See Table 25. Communication information AnIn1 Function Value Max [5137] With AnIn1 Function VaMax you define a user-defined value for the signal. Only visible when user-defined is selected in menu [5136]. Communication information NOTE: With AnIn Min, AnIn Max, AnIn Function Min and AnIn Function Max settings, loss of feedback signals (e.g. voltage drop due to long sensor wiring) can be compensated to ensure an accurate process control.

Example: Process sensor is a sensor with the following specifica- tion: Range: 0–3 bar Output: 2–10 mA Analogue input should be set up according to: [512] AnIn1 Setup = User mA [5131] AnIn1 Min = 2 mA [5132] AnIn1 Max = 10 mA [5134] AnIn1 Function Min = User-defined [5135] AnIn1 VaMin = 0.000 bar [5136] AnIn 1 Function Max = User-defined [5137] AnIn1 VaMax = 3.000 bar AnIn1 Operation [5138] Communication information AnIn1 Filter [5139] If the input signal is unstable (e.g. fluctuation reference value), the filter can be used to stabilize the signal. A change of the input signal will reach 63% on AnIn1 within the set AnIn1 Filter time. After 5 times the set time, AnIn1 will have reached 100% of the input change. See Fig. 97. Communication information

5136 AnIn1 FcMax Stp A Max

5138 AnIn1 Oper Stp A Add+

5137 AnIn1 VaMax Stp A 0.000

5139 AnIn1 Filt Stp A 0.1s

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

5136 AnIn1 Function Max metadata — PDF page 126

Source row Property Source value
1 Default: Max

5136 AnIn1 Function Max selections — PDF page 126

Source row Selection Integer code Description
1 Min 0 Min value
2 Max 1 Max value
3 User-defined 2 Define user value in menu [5137]

5136 communication — PDF page 126

Source row Property Source value
1 Modbus Instance no/ DeviceNet no: 43207
2 Profibus slot/index 169/111
3 Fieldbus format Long, Speed/Torque 1=1 rpm or %. Other 1= 0.001
4 Modbus format EInt

5138 AnIn1 Operation metadata — PDF page 126

Source row Property Source value
1 Default: Add+

5138 AnIn1 Operation selections — PDF page 126

Source row Selection Integer code Description
1 Add+ 0 Analogue signal is added to selected function in menu [511].
2 Sub- 1 Analogue signal is subtracted from selected function in menu [511].

5138 communication — PDF page 126

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43208
2 Profibus slot/index 169/112
3 Fieldbus format UInt
4 Modbus format UInt

5137 AnIn1 Value Max metadata — PDF page 126

Source row Property Source value
1 Default: 0.000
2 Range: -10000.000 – 10000.000

5137 communication — PDF page 126

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43551
2 Profibus slot/index 170/200
3 Fieldbus format Long, Speed 1=1 rpm Torque 1=1% Process val 1=0.001
4 Modbus format EInt

5139 AnIn1 Filter metadata — PDF page 126

Source row Property Source value
1 Default: 0.1 s
2 Range: 0.001 – 10.0 s

5139 communication — PDF page 126

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43209
2 Profibus slot/index 169/113
3 Fieldbus format Long, 1=0.001 s
4 Modbus format EInt

Manual — Analogue input enable and second third input — page 127

Manual reference: physical PDF page 127. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 97 AnIn1 Enable [513A] Parameter for enable/disable analogue input selection via digital inputs (DigIn set to function AnIn Select). Communication information AnIn2 Function [514] Parameter for setting the function of Analogue Input 2. Same function as AnIn1 Func [511]. Communication information

AnIn2 Setup [515] Parameter for setting the function of Analogue Input 2. Same functions as AnIn1 Setup [512]. Communication information AnIn2 Advanced [516] Same functions and submenus as under AnIn1 Advanced [513]. Communication information AnIn3 Function [517] Parameter for setting the function of Analogue Input 3. Same function as AnIn1 Func [511]. Communication information

AnIn change;100%;63%;Original input signal;Filtered AnIn signal;T;5×T. Original response curve retained.

516 AnIn2 Advan / Stp A; blank display.

515 AnIn2 Setup Stp A 4-20mA

513A AnIn1 Enabl Stp A On

514 AnIn2 Fc Stp A Off

517 AnIn3 Fc Stp A Off

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

515 AnIn2 Setup metadata — PDF page 127

Source row Property Source value
1 Default: 4 – 20 mA
2 Dependent on Setting of switch S2
3 Selection: Same as in menu [512].

515 communication — PDF page 127

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43212
2 Profibus slot/index 169/116
3 Fieldbus format UInt
4 Modbus format UInt

513A AnIn1 Enable metadata — PDF page 127

Source row Property Source value
1 Default: On

513A AnIn1 Enable selections — PDF page 127

Source row Selection Integer code Description
1 On 0 AnIn1 is always active
2 !DigIn 1 AnIn1 is only active if the digital input is low.
3 DigIn 2 AnIn1 is only active if the digital input is high.

516 AnIn2 Advanced communication — PDF page 127

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43213–43220 43542 43552
2 Profibus slot/index 169/117–124 170/191 170/201

513A communication — PDF page 127

Source row Property Source value
1 Modbus Instance no/DeviceNet no: AnIn1 43210
2 Profibus slot/index AnIn1 169/114
3 Fieldbus format UInt
4 Modbus format UInt

514 AnIn2 Function metadata — PDF page 127

Source row Property Source value
1 Default: Off
2 Selection: Same as in menu [511]

514 communication — PDF page 127

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43211
2 Profibus slot/index 169/115
3 Fieldbus format UInt
4 Modbus format UInt

517 AnIn3 Function communication — PDF page 127

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43221
2 Profibus slot/index 169/125
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue third fourth setup and communication — page 128

Manual reference: physical PDF page 128. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

AnIn3 Setup [518] Same functions as AnIn1 Setup [512]. Communication information AnIn3 Advanced [519] Same functions and submenus as under AnIn1 Advanced [513]. Communication information AnIn4 Function [51A] Parameter for setting the function of Analogue Input 4. Same function as AnIn1 Func [511]. Communication information

AnIn4 Set-up [51B] Same functions as AnIn1 Setup [512]. Communication information AnIn4 Advanced [51C] Same functions and submenus as under AnIn1 Advanced [513]. Communication information

519 AnIn3 Advan / Stp A; blank display.

51C AnIn4 Advan / Stp A; blank display.

518 AnIn3 Setup Stp A 4-20mA

51B AnIn4 Setup Stp A 4-20mA

51A AnIn4 Fc Stp A Off

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

518 AnIn3 Setup metadata — PDF page 128

Source row Property Source value
1 Default: 4–20 mA
2 Dependent on Setting of switch S3
3 Selection: Same as in menu [512].

51B AnIn4 Setup metadata — PDF page 128

Source row Property Source value
1 Default: 4-20 mA
2 Dependent on Setting of switch S4
3 Selection: Same as in menu [512].

518 communication — PDF page 128

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43222
2 Profibus slot/index 169/126
3 Fieldbus format UInt
4 Modbus format UInt

51B communication — PDF page 128

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43232
2 Profibus slot/index 169/136
3 Fieldbus format UInt
4 Modbus format UInt

519 AnIn3 Advanced communication — PDF page 128

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43223–43230 43543 43553
2 Profibus slot/index 169/127–169/134 170/192 170/202

51C AnIn4 Advanced communication — PDF page 128

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43233–43240 43544 43554
2 Profibus slot/index 169/137–144 170/193 170/203

51A AnIn4 Function metadata — PDF page 128

Source row Property Source value
1 Default: Off
2 Selection: Same as in menu [511]

51A communication — PDF page 128

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43231
2 Profibus slot/index 169/135
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Digital input selections logic and active low conditions — page 129

Manual reference: physical PDF page 129. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.5.2 Digital Inputs [520] Submenu with all the settings for the digital inputs. NOTE: Additional inputs will become available when the I/O option boards are connected. Digital Input 1 [521] To select the function of the digital input. On the standard control board there are eight digital inputs. If the same function is programmed for more than one input that function will be activated according to “OR” logic if nothing else is stated.

521 DigIn 1 Stp A RunL

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

521 Digital Input1 continued selections — PDF page 129

Source row Selection Integer code Description
1 Preset Ctrl2 11 To select the Preset Reference.
2 Preset Ctrl3 12 To select the Preset Reference.
3 MotPot Up 13 Increases the internal reference value according to the set AccMotPot time [333]. Has the same function as a “real” motor potentiometer, see Fig. 78.
4 MotPot Down 14 Decreases the internal reference value according to the set DecMotPot time [334]. See MotPot Up.
5 Pump1 Feedb 15 Feedback input pump1 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
6 Pump2 Feedb 16 Feedback input pump 2 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
7 Pump3 Feedb 17 Feedback input pump3 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
8 Pump4 Feedb 18 Feedback input pump 4 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
9 Pump5 Feedb 19 Feedback input pump5 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
10 Pump6 Feedb 20 Feedback input pump 6 for Pump/Fan control and informs about the status of the auxiliary connected pump/fan.
11 Timer 1 21 Timer 1 Delay [643] will be activated on the rising edge of this signal.
12 Timer 2 22 Timer 2 Delay [653] will be activated on the rising edge of this signal.
13 Set Ctrl 1 23 Activates other parameter set. See Table 26 for selection possibilities.
14 Set Ctrl 2 24 Activates other parameter set. See Table 26 for selection possibilities.
15 Mot PreMag 25 Pre-magnetises the motor. Used for faster motor start.
16 Jog 26 To activate the Jog function. Gives a Run command with the set Jog speed and Direction, page 95.
17 Ext Mot Temp 27 Be aware that if there is nothing connected to the input, the AC drive will trip at “External Motor Temp” immediately. NOTE: The External Motor Temp is active low.
18 Loc/Rem 28 Activate local mode defined in [2171] and [2172].
19 AnIn select 29 Activate/deactivate analogue inputs defined in [513A], [516A], [519A] and [51CA]
20 LC Level 30 Liquid cooling low level signal. NOTE: The Liquid Cooling Level is active low.

521 Digital Input1 metadata — PDF page 129

Source row Property Source value
1 Default: RunL

521 Digital Input1 selections — PDF page 129

Source row Selection Integer code Description
1 Off 0 The input is not active.
2 Lim Switch+ 1 AC drive ramps to stop and prevents rotation in “R” direction (clockwise), when the signal is low! NOTE: The Lim Switch+ is active low. NOTE: Activated according to “AND” logic.
3 Lim Switch - 2 AC drive ramps to stop and prevents rota- tion in “L” direction (counter clockwise) when the signal is low! NOTE: The Lim Switch- is active low. NOTE: Activated according to “AND” logic.
4 Ext. Trip 3 Be aware that if there is nothing connected to the input, the AC drive will trip at “Exter- nal trip” immediately. NOTE: The External Trip is active low. NOTE: Activated according to “AND” logic.
5 Stop 4 Stop command according to the selected Stop mode in menu [33B]. NOTE: The Stop command is active low. NOTE: Activated according to “AND” logic.
6 Enable 5 Enable command. General start condition to run the AC drive. If made low during running the output of the AC drive is cut off immediately, causing the motor to coast to zero speed. NOTE: If none of the digital inputs are programmed to “Enable”, the internal enable signal is active. NOTE: Activated according to “AND” logic.
7 RunR 6 Run Right command (positive speed). The output of the AC drive will be a clockwise rotary field.
8 RunL 7 Run Left command (negative speed). The output of the AC drive will be a counter-clockwise rotary field.
9 Reset 9 Reset command. To reset a Trip condition and to enable the Autoreset function.
10 Preset Ctrl1 10 To select the Preset Reference.

Manual — Digital input communication and parameter set selection — page 130

Manual reference: physical PDF page 130. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

NOTE: For bipol function, input RunR and RunL needs to be active and Rotation, [219] must be set to “R+L”. Communication information Table 26 NOTE: To activate the parameter set selection, menu 241 must be set to DigIn. Digital Input 2 [522] to Digital Input 8 [528] Same function as DigIn 1 [521]. Default function for DigIn 8 is Reset. For DigIn 3 to 7 the default function is Off. Communication information

Additional digital inputs [529] to [52H] Additional digital inputs with I/O option board installed, B1 DigIn 1 [529] - B3 DigIn 3 [52H]. B stands for board and 1 to 3 is the number of the board which is related to the position of the I/O option board on the option mounting plate. The functions and selections are the same as DigIn 1 [521]. Communication information

522 DigIn 2 Stp A RunR

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

521 Digital Input1 continued selections — PDF page 130

Source row Selection Integer code Description
1 Brk Ackn 31 Brake acknowledge input for Brake Fault control. Function is activated via this selec- tion see menu [33H] page 92

529–52H Additional Inputs communication — PDF page 130

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43501–43509
2 Profibus slot/index 170/150–170/158
3 Fieldbus format Int
4 Modbus format Int

521 communication — PDF page 130

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43241
2 Profibus slot/index 169/145
3 Fieldbus format UInt
4 Modbus format UInt

Table26 Parameter Set selection — PDF page 130

Source row Parameter Set Set Ctrl1 Set Ctrl2
1 A 0 0
2 B 1 0
3 C 0 1
4 D 1 1

522 Digital Input2 metadata — PDF page 130

Source row Property Source value
1 Default: RunR
2 Selection: Same as in menu [521]

522–528 communication — PDF page 130

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43241–43248
2 Profibus slot/index 169/146–169/152
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue output functions and mirroring restriction — page 131

Manual reference: physical PDF page 131. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.5.3 Analogue Outputs [530] Submenu with all settings for the analogue outputs. Selections can be made from application and AC drive values, in order to visualize actual status. Analogue out- puts can also be used as a mirror of the analogue input. Such a signal can be used as: • a reference signal for the next AC drive in a Master/ Slave configuration (see Fig. 98). • a feedback acknowledgement of the received ana- logue reference value. AnOut1 Function [531] Sets the function for the Analogue Output 1. Scale and range are defined by AnOut1 Advanced settings [533]. NOTE: When selections AnIn1, AnIn2 …. AnIn4 is selected, the setup of the AnOut (menu [532] or [535]) has to be set to 0-10V or 0-20mA. When the AnOut Setup is set to e.g. 4-20mA, the mirroring is not working correct.

Communication information AnOut 1 Setup [532] Preset scaling and offset of the output configuration. Communication information

532 AnOut1 Setup Stp A 4-20mA

531 AnOut1 Fc Stp A Speed

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

531 AnOut1 Function communication — PDF page 131

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43251
2 Profibus slot/index 169/155
3 Fieldbus format UInt
4 Modbus format UInt

532 AnOut1 Setup metadata — PDF page 131

Source row Property Source value
1 Default: 4-20mA

532 AnOut1 Setup selections — PDF page 131

Source row Selection Integer code Description
1 4–20mA 0 The current output has a fixed threshold (Live Zero) of 4 mA and controls the full range for the output signal. See Fig. 95.
2 0–20mA 1 Normal full current scale configuration of the output that controls the full range for the output signal. See Fig. 94.
3 User mA 2 The scale of the current controlled output that controls the full range for the output signal. Can be defined by the advanced AnOut Min and AnOut Max menus.
4 User Bipol mA 3 Sets the output for a bipolar current output, where the scale controls the range for the output signal. Scale can be defined in advanced menu AnOut Bipol.
5 0-10V 4 Normal full voltage scale configuration of the output that controls the full range for the output signal. See Fig. 94.
6 2–10V 5 The voltage output has a fixed threshold (Live Zero) of 2 V and controls the full range for the output signal. See Fig. 95.
7 User V 6 The scale of the voltage controlled output that controls the full range for the output signal. Can be defined by the advanced AnOut Min and AnOut Max menus.
8 User Bipol V 7 Sets the output for a bipolar voltage output, where the scale controls the range for the output signal. Scale can be defined in advanced menu AnOut Bipol.

531 AnOut1 Function metadata — PDF page 131

Source row Property Source value
1 Default: Speed

531 AnOut1 Function selections — PDF page 131

Source row Selection Integer code Description
1 Process Val 0 Actual process value according to Process feedback signal.
2 Speed 1 Actual speed.
3 Torque 2 Actual torque.
4 Process Ref 3 Actual process reference value.
5 Shaft Power 4 Actual shaft power.
6 Frequency 5 Actual frequency.
7 Current 6 Actual current.
8 El power 7 Actual electrical power.
9 Output volt 8 Actual output voltage.
10 DC-voltage 9 Actual DC link voltage.
11 AnIn1 10 Mirror of received signal value on AnIn1.
12 AnIn2 11 Mirror of received signal value on AnIn2.
13 AnIn3 12 Mirror of received signal value on AnIn3.
14 AnIn4 13 Mirror of received signal value on AnIn4.
15 Speed Ref 14 Actual internal speed reference Value after ramp and V/Hz.
16 Torque Ref 15 Actual torque reference value (=0 in V/Hz mode)

532 communication — PDF page 131

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43252
2 Profibus slot/index 169/156
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue output min max and bipolar setup — page 132

Manual reference: physical PDF page 132. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 98 AnOut1 Advanced [533] With the functions in the AnOut1 Advanced menu, the output can be completely defined according to the application needs. The menus will automatically be adapted to “mA” or “V”, according to the selection in AnOut1 Setup [532]. AnOut1 Min [5331] This parameter is automatically displayed if User mA or User V is selected in menu AnOut 1 Setup [532]. The menu will automatically adapt to current or voltage set- ting according to the selected setup. Only visible if [532] = User mA/V. Communication information

AnOut1 Max [5332] This parameter is automatically displayed if User mA or User V is selected in menu AnOut1 Setup [532]. The menu will automatically adapt to current or voltage set- ting according to the selected setup. Only visible if [532] = User mA/V. Communication information AnOut1 Bipol [5333] Automatically displayed if User Bipol mA or User Bipol V is selected in menu AnOut1 Setup. The menu will automatically show mA or V range according to the selected function. The range is set by changing the pos- itive maximum value; the negative value is automati- cally adapted accordingly. Only visible if [512] = User Bipol mA/V. Communication information

Ref.;AnOut;AC drive1 Master;Ref.;AC drive2 Slave. Original connections authoritative; not inferred wiring instructions.

533 AnOut1 Adv / Stp A; blank display.

5332 AnOut 1 Max Stp 20.0mA

5331 AnOut 1 Min Stp A 4mA

5333 AnOut1Bipol Stp -10.00-10.00V

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

5332 AnOut1 Max metadata — PDF page 132

Source row Property Source value
1 Default: 20.00 mA
2 Range: 0.00–20.00 mA, 0–10.00 V

5332 communication — PDF page 132

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43254
2 Profibus slot/index 169/158
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

5331 AnOut1 Min metadata — PDF page 132

Source row Property Source value
1 Default: 4 mA
2 Range: 0.00 – 20.00 mA, 0 – 10.00 V

5333 AnOut1 Bipolar metadata — PDF page 132

Source row Property Source value
1 Default: -10.00–10.00 V
2 Range: -10.00–10.00 V, -20.0–20.0 mA

5331 communication — PDF page 132

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43253
2 Profibus slot/index 169/157
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

5333 communication — PDF page 132

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43255
2 Profibus slot/index 169/159
3 Fieldbus format Long, 1=0.01
4 Modbus format EInt

Manual — Analogue output process scaling limits — page 133

Manual reference: physical PDF page 133. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

AnOut1 Function Min [5334] With AnOut1 Function Min the physical minimum value is scaled to selected presentation. The default scaling is dependent of the selected function of AnOut1 [531]. Table 27 shows corresponding values for the min and max selections depending on the function of the ana- logue output [531]. Table 27 *) Fmin is dependent on the set value in menu “Minimum Speed [341]”. Communication information

Example Set the AnOut function for Motorfrequency to 0Hz, set AnOut functionMin [5334] to “User-defined” and AnOut1 VaMin[5335] = 0.0. This results in an anlogue output signal from 0/4 mA to 20mA:: 0Hz to Fmot. This principle is valid for all Min to Max settings. AnOut1 Function Value Min [5335] With AnOut1 Function VaMin you define a user-defined value for the signal. Only visible when user-defined is selected in menu [5334]. Communication information AnOut1 Function Max [5336] With AnOut1 Function Min the physical minimum value is scaled to selected presentation. The default scaling is dependent on the selected function of AnOut1 [531]. See Table 27. Communication information NOTE: It is possible to set AnOut1 up as an inverted output signal by setting AnOut1 Min > AnOut1 Max. See Fig. 96.

5334 AnOut1FCMin Stp A Min

5335 AnOut1VaMin Stp A 0.000

5336 AnOut1FCMax Stp A Max

Literal supplier settings. Read with physical same-page procedures, conditions, warnings and continuation pages. Display examples are not defaults. No engineering approval.

5334 AnOut1 Function Min metadata — PDF page 133

Source row Property Source value
1 Default: Min

5334 AnOut1 Function Min selections — PDF page 133

Source row Selection Integer code Description
1 Min 0 Min value
2 Max 1 Max value
3 User-defined 2 Define user value in menu [5335]

5335 AnOut1 Value Min metadata — PDF page 133

Source row Property Source value
1 Default: 0.000
2 Range: -10000.000–10000.000

Table27 Analogue Output function limits — PDF page 133

Source row Function Min Value Max Value
1 Process Value Process Min [324] Process Max [325]
2 Speed Min Speed [341] Max Speed [343]
3 Torque 0% Max Torque [351]
4 Process Ref Process Min [324] Process Max [325]
5 Shaft Power 0% Motor Power [223]
6 Frequency Fmin * Motor Frequency [222]
7 Current 0 A Motor Current [224]
8 El Power 0 W Motor Power [223]
9 Output Voltage 0 V Motor Voltage [221]
10 DC voltage 0 V 1000 V
11 AnIn1 AnIn1 Function Min AnIn1 Function Max
12 AnIn2 AnIn2 Function Min AnIn2 Function Max
13 AnIn3 AnIn3 Function Min AnIn3 Function Max
14 AnIn4 AnIn4 Function Min AnIn4 Function Max

5335 communication — PDF page 133

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43545
2 Profibus slot/index 170/194
3 Fieldbus format Long, Speed 1=1 rpm Torque 1=1% Process val 1=0.001
4 Modbus format EInt

5336 AnOut1 Function Max metadata — PDF page 133

Source row Property Source value
1 Default: Max

5336 AnOut1 Function Max selections — PDF page 133

Source row Selection Integer code Description
1 Min 0 Min value
2 Max 1 Max value
3 User defined 2 Define user value in menu [5337]

5334 communication — PDF page 133

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43256
2 Profibus slot/index 169/160
3 Fieldbus format Long, 1=0.1 W, 0.1 Hz, 0.1 A, 0.1 V or 0.001
4 Modbus format EInt

5336 communication — PDF page 133

Source row Property Source value
1 Modbus Instance no/DeviceNet no: 43257
2 Profibus slot/index 169/161
3 Fieldbus format Long, 0.001
4 Modbus format EInt

Manual — Analogue output maximum and output2 configuration — page 134

Manual reference: physical PDF page 134. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

AnOut1 Function Value Max [5337] With AnOut1 Function VaMax you define a user-defined value for the signal. Only visible when user-defined is selected in menu [5334]. Communication information AnOut2 Function [534] Sets the function for the Analogue Output 2. Communication information AnOut2 Setup [535] Preset scaling and offset of the output configuration for analogue output 2.

Communication information AnOut2 Advanced [536] Same functions and submenus as under AnOut1 Advanced [533]. Communication information

536 AnOut2 Advan / Stp A; blank value illustration.

5337 AnOut1VaMax Stp A 0.000

534 AnOut2 Fc Stp A Torque

535 AnOut2 Setup Stp A 4-20mA

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

535 communication — PDF page 134

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43262
2 Profibus slot/index 169/166
3 Fieldbus format UInt
4 Modbus format UInt

5337 AnOut1 Value Max metadata — PDF page 134

Source row Property Source value
1 Default: 0.000
2 Range: -10000.000–10000.000

5337 communication — PDF page 134

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43555
2 Profibus slot/index 170/204
3 Fieldbus format Long, Speed 1=1 rpm Torque 1=1% Process val 1=0.001
4 Modbus format EInt

536 AnOut2 Advanced communication — PDF page 134

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43263–43267 43546 43556
2 Profibus slot/index 169/167–169/171 170/195 170/205

534 AnOut2 Function metadata — PDF page 134

Source row Property Source value
1 Default: Torque
2 Selection: Same as in menu [531]

534 communication — PDF page 134

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43261
2 Profibus slot/index 169/165
3 Fieldbus format UInt
4 Modbus format UInt

535 AnOut2 Setup metadata — PDF page 134

Source row Property Source value
1 Default: 4-20mA
2 Selection: Same as in menu [532]

Manual — Digital output1 definitions and selections — page 135

Manual reference: physical PDF page 135. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.5.4 Digital Outputs [540] Submenu with all the settings for the digital outputs. Digital Out 1 [541] Sets the function for the digital output 1. NOTE: The definitions described here are valid for the active output condition.

541 DigOut 1 Stp A Ready

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

541 Digital Output1 continued options — PDF page 135

Source row Selection Integer code Description
1 Max Alarm 20 The max alarm level has been reached.
2 Max PreAlarm 21 The max pre alarm level has been reached.
3 Min Alarm 22 The min alarm level has been reached.
4 Min PreAlarm 23 The min pre alarm Level has been reached.
5 LY 24 Logic output Y.
6 !LY 25 Logic output Y inverted.
7 LZ 26 Logic output Z.
8 !LZ 27 Logic output Z inverted.
9 CA 1 28 Analogue comparator 1 output.
10 !A1 29 Analogue comp 1 inverted output.
11 CA 2 30 Analogue comparator 2 output.
12 !A2 31 Analogue comp 2 inverted output.
13 CD 1 32 Digital comparator 1 output.
14 !D1 33 Digital comp 1 inverted output.
15 CD 2 34 Digital comparator 2 output.
16 !D2 35 Digital comp 2 inverted output.
17 Operation 36 Run command is active or AC drive running. The signal can be used to control the mains contactor if the AC drive is equipped with Standby supply option.
18 T1Q 37 Timer1 output
19 !T1Q 38 Timer1 inverted output
20 T2Q 39 Timer2 output
21 !T2Q 40 Timer2 inverted output
22 Sleeping 41 Sleeping function activated
23 Crane Deviat 42 Tripped on deviation
24 PumpSlave1 43 Activate pump slave 1
25 PumpSlave2 44 Activate pump slave 2
26 PumpSlave3 45 Activate pump slave 3
27 PumpSlave4 46 Activate pump slave 4
28 PumpSlave5 47 Activate pump slave 5
29 PumpSlave6 48 Activate pump slave 6
30 PumpMaster1 49 Activate pump master 1
31 PumpMaster2 50 Activate pump master 2
32 PumpMaster3 51 Activate pump master 3
33 PumpMaster4 52 Activate pump master 4
34 PumpMaster5 53 Activate pump master 5
35 PumpMaster6 54 Activate pump master 6
36 All Pumps 55 All pumps are running
37 Only Master 56 Only the master is running
38 Loc/Rem 57 Local/Rem function is active
39 Standby 58 Standby supply option is active

541 Digital Output1 metadata — PDF page 135

Source row Property Source value
1 Default: Ready

541 Digital Output1 selections — PDF page 135

Source row Selection Integer code Description
1 Off 0 Output is not active and constantly low.
2 On 1 Output is made constantly high, i.e. for checking circuits and trouble shooting.
3 Run 2 Running. The AC drive output is active = produces current for the motor.
4 Stop 3 The AC drive output is not active.
5 0Hz 4 The output frequency=0±0.1Hz when in Run condition.
6 Acc/Dec 5 The speed is increasing or decreasing along the acc. ramp dec. ramp.
7 At Process 6 The output = Reference.
8 At Max spd 7 The frequency is limited by the Maximum Speed.
9 No Trip 8 No Trip condition active.
10 Trip 9 A Trip condition is active.
11 AutoRst Trip 10 Autoreset trip condition active.
12 Limit 11 A Limit condition is active.
13 Warning 12 A Warning condition is active.
14 Ready 13 The AC drive is ready for operation and to accept a start command. This means that the AC drive is powered up and healthy.
15 T= Tlim 14 The torque is limited by the torque limit function.
16 I>Inom 15 The output current is higher than the motor nominal current [224], reduced according to Motor ventilation [228], see Fig. 62.
17 Brake 16 The output is used to control a mechanical brake.
18 Sgnl<Offset 17 One of the AnIn input signals is lower than 75% of the threshold level.
19 Alarm 18 The max or min alarm level has been reached.
20 Pre-Alarm 19 The max or min pre alarm level has been reached.

Manual — Digital output1 trip direction and comparator selections — page 136

Manual reference: physical PDF page 136. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information

I2t

541 Digital Output1 continued options — PDF page 136

Source row Selection Integer code Description
1 PTC Trip 59 Trip when function is active
2 PT100 Trip 60 Trip when function is active
3 Overvolt 61 Overvoltage due to high main voltage
4 Overvolt G 62 Overvoltage due to generation mode
5 Overvolt D 63 Overvoltage due to deceleration
6 Acc 64 Acceleration along the acc. ramp
7 Dec 65 Deceleration along the dec. ramp
8 I²t 66 I²t limit protection active
9 V-Limit 67 Overvoltage limit function active
10 C-Limit 68 Overcurrent limit function active
11 Overtemp 69 Over temperature warning
12 Low voltage 70 Low voltage warning
13 DigIn 1 71 Digital input 1
14 DigIn 2 72 Digital input 2
15 DigIn 3 73 Digital input 3
16 DigIn 4 74 Digital input 4
17 DigIn 5 75 Digital input 5
18 DigIn 6 76 Digital input 6
19 DigIn 7 77 Digital input 7
20 DigIn 8 78 Digital input 8
21 ManRst Trip 79 Active trip that needs to be manually reset
22 Com Error 80 Serial communication lost
23 External Fan 81 The AC drive requires external cooling. Internal fans are active.
24 LC Pump 82 Activate liquid cooling pump
25 LC HE Fan 83 Activate liquid cooling heat exchanger fan
26 LC Level 84 Liquid cooling low level signal active
27 Run Right 85 Positive speed (>0.5%), i.e. forward/ clockwise direction.
28 Run Left 86 Negative speed (≤0.5%), i.e. reverse counter clockwise direction.
29 Com Active 87 Fieldbus communication active.
30 Brk Fault 88 Tripped on brake fault (not released)
31 BrkNotEngage 89 Warning and continued operation (keep torque) due to Brake not engaged during stop.
32 Option 90 Failure occured in built-in option board.
33 CA3 91 Analogue comparator 3 output
34 !A3 92 Analogue comparator 3 inverted output
35 CA4 93 Analogue comparator 4 output
36 !A4 94 Analogue comparator 4 inverted output
37 CD3 95 Digital comparator 3 output
38 !D3 96 Digital comparator 3 inverted output

541 Digital Output1 final options — PDF page 136

Source row Selection Integer code Description
1 CD4 97 Digital comparator 4 output
2 !D4 98 Digital comparator 4 inverted output

541 communication — PDF page 136

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43271
2 Profibus slot/index 169/175
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Digital output2 and relay option conditions — page 137

Manual reference: physical PDF page 137. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Digital Out 2 [542] NOTE: The definitions described here are valid for the active output condition. Sets the function for the digital output 2. Communication information 11.5.5 Relays [550] Submenu with all the settings for the relay outputs. The relay mode selection makes it possible to establish a “fail safe” relay operation by using the normal closed contact to function as the normal open contact. NOTE: Additional relays will become available when I/O option boards are connected. Maximum 3 boards with 3 relays each. Relay 1 [551] Sets the function for the relay output 1. Same function as digital output 1 [541] can be selected. Communication information

Relay 2 [552] NOTE: The definitions described here are valid for the active output condition. Sets the function for the relay output 2. Communication information Relay 3 [553] Sets the function for the relay output 3. Communication information Board Relay [554] to [55C] These additional relays are only visible if an I/O option board is fitted in slot 1, 2, or 3. The outputs are named B1 Relay 1–3, B2 Relay 1–3 and B3 Relay 1–3. B stands for board and 1–3 is the number of the board which is related to the position of the I/O option board on the option mounting plate. NOTE: Visible only if optional board is detected or if any input/output is activated.

542 DigOut2 Stp A Brake

552 Relay 2 Stp A Run

553 Relay 3 Stp A Off

551 Relay 1 Stp A Trip

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

542 Digital Output2 metadata — PDF page 137

Source row Property Source value
1 Default: Brake
2 Selection: Same as in menu [541]

552 Relay2 metadata — PDF page 137

Source row Property Source value
1 Default: Run
2 Selection: Same as in menu [541]

542 communication — PDF page 137

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43272
2 Profibus slot/index 169/176
3 Fieldbus format UInt
4 Modbus format UInt

552 communication — PDF page 137

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43274
2 Profibus slot/index 169/178
3 Fieldbus format UInt
4 Modbus format UInt

553 Relay3 metadata — PDF page 137

Source row Property Source value
1 Default: Off
2 Selection: Same as in menu [541]

553 communication — PDF page 137

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43275
2 Profibus slot/index 169/179
3 Fieldbus format UInt
4 Modbus format UInt

551 Relay1 metadata — PDF page 137

Source row Property Source value
1 Default: Trip
2 Selection: Same as in menu [541]

551 communication — PDF page 137

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43273
2 Profibus slot/index 169/177
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Relay modes virtual connections and start delay example — page 138

Manual reference: physical PDF page 138. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Communication information Relay Advanced [55D] This function makes it possible to ensure that the relay will also be closed when the AC drive is malfunctioning or powered down. Example A process always requires a certain minimum flow. To control the required number of pumps by the relay mode NC, the e.g. the pumps can be controlled nor- mally by the pump control, but are also activated when the AC drive is tripped or powered down. Relay 1 Mode [55D1] Communication information Relay Modes [55D2] to [55DC] Same function as for relay 1 mode [55D1]. Communication information

11.5.6 Virtual Connections [560] Functions to enable eight internal connections of comparator, timer and digital signals, without occupy- ing physical digital in/outputs. Virtual connections are used to wireless connection of a digital output function to a digital input function. Available signals and control functions can be used to create your own specific func- tions. Example of start delay The motor will start in RunR 10 seconds after DigIn1 gets high. DigIn1 has a time delay of 10 s. NOTE: When a digital input and a virtual destination are set to the same function, this function will act as an OR logic function. Virtual Connection 1 Destination [561] With this function the destination of the virtual connec- tion is established. When a function can be controlled by several sources, e.g. VC destination or Digital Input, the function will be controlled in conformity with “OR logic”. See DigIn for descriptions of the different selec- tions. Communication information

55D Relay Adv / Stp A; blank value illustration.

55D1 Relay Mode Stp A N.O

561 VIO 1 Dest Stp A Off

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

554–55C Board Relays communication continuation — PDF page 138

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43511–43519
2 Profibus slot/index 170/160–170/168
3 Fieldbus format UInt
4 Modbus format UInt

Virtual connection start delay example — PDF page 138

Source row Menu Function Setting
1 [521] DigIn1 Timer 1
2 [561] VIO 1 Dest RunR
3 [562] VIO 1 Source T1Q
4 [641] Timer1 Trig DigIn 1
5 [642] Timer1 Mode Delay
6 [643] Timer1 Delay 0:00:10

55D1 Relay1 Mode metadata — PDF page 138

Source row Property Source value
1 Default: N.O

55D1 Relay1 Mode selections — PDF page 138

Source row Selection Integer code Description
1 N.O 0 The normal open contact of the relay will be activated when the function is active.
2 N.C 1 The normally closed contact of the relay will act as a normal open contact. The contact will be opened when function is not active and closed when function is active.

561 VIO1 Destination metadata — PDF page 138

Source row Property Source value
1 Default: Off
2 Selection: Same selections as for Digital Input 1, menu [521].

55D1 communication — PDF page 138

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43276
2 Profibus slot/index 169/180
3 Fieldbus format UInt
4 Modbus format UInt

561 communication — PDF page 138

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43281
2 Profibus slot/index 169/185
3 Fieldbus format UInt
4 Modbus format UInt

55D2–55DC Relay Modes communication — PDF page 138

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43277–43278, 43521–43529
2 Profibus slot/index 169/181–169/182, 170/170–170/178
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Virtual connection groups and comparator introduction — page 139

Manual reference: physical PDF page 139. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Virtual Connection 1 Source , [562] With this function the source of the virtual connection is defined. See DigOut 1 for description of the different selections. Communication information Virtual Connections 2-8 [563] to [56G] Same function as virtual connection 1 [561] and [562]. Communication information for virtual connections 2-8 Destination. Communication information for virtual connections 2-8 Source.

11.6 Logical Functions and Timers [600] With the Comparators, Logic Functions and Timers, conditional signals can be programmed for control or signalling features. This gives you the ability to compare different signals and values in order to generate moni- toring/controlling features. 11.6.1 Comparators [610] The comparators available make it possible to monitor different internal signals and values, and visualize via digital relay outputs, when a specific value or status is reached or established. Analogue comparators [611] - [614] There are 4 analogue comparators that compare any available analogue value (including the analogue refer- ence inputs) with two adjustable levels. The two levels available are Level HI and Level LO. There are two ana- logue comparator types selectable, an analogue com- parator with hysteresis and an analogue window comparator. The analogue hysteresis type comparator uses the two available levels to create a hysteresis for the compara- tor between setting and resetting the output. This func- tion gives a clear difference in switching levels, which lets the process adapt until a certain action is started. With such a hysteresis, even an unstable analogue sig- nal can be monitored without getting a nervous compa- rator output signal. Another feature is the possibility to get a fixed indication that a certain level has been passed. The comparator can latch by setting Level LO to a higher value than Level HI. The analogue window comparator uses the two availa- ble levels to define the window in which the analogue value should be within for setting the comparator out- put. The input analogue value of the comparator can also be selected as bipolar, i.e. treated as signed value or unipolar, i.e. treated as absolute value. Refer to Fig. 103, page 141 where these functions are illustrated. Digital comparators [615] There are 4 digital comparators that compare any avail- able digital signal. The output signals of these comparators can be logi- cally tied together to yield a logical output signal. All the output signals can be programmed to the digital or relay outputs or used as a source for the virtual con- nections [560].

562 VIO 1 Source Stp A Off

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

562 VIO1 Source metadata — PDF page 139

Source row Property Source value
1 Default: Off
2 Selection: Same as for menu [541].

562 communication — PDF page 139

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43282
2 Profibus slot/index 169/186
3 Fieldbus format UInt
4 Modbus format UInt

563–56G Virtual Connections2–8 Destinations — PDF page 139

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43283, 43285, 43287, 43289, 43291, 43293, 43295
2 Profibus slot/index 169/ 187, 189, 191, 193, 195, 197, 199
3 Fieldbus format UInt
4 Modbus format UInt

563–56G Virtual Connections2–8 Sources — PDF page 139

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43284, 43286, 43288, 43290, 43292, 43294, 43296
2 Profibus slot/index 169/ 188, 190, 192, 194, 196, 198, 200
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue comparator source and hysteresis window definitions — page 140

Manual reference: physical PDF page 140. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

CA1 Setup [611] Analogue comparator 1, parameter group. Analogue Comparator 1, Value [6111] Selection of the analogue value for Analogue Compara- tor 1 (CA1). Analogue comparator 1 compares the selectable ana- logue value in menu [6111] with the constant Level HI in menu [6112] and constant Level LO in menu [6113]. If Bipolar type[6115] input signal is selected then the comparison is made with sign otherwise if unipolar selected then comparison is made with absolute val- ues. For Hysteresis comparator type [6114], when the value exceeds the upper limit level high, the output signal CA1 is set high and !A1 low, see Fig. 99. When the value decreases below the lower limit, the output signal CA1 is set low and !A1 high. Fig. 99 Analogue comparator type Hysteresiss For Window comparator type [6114], when the value is between the lower and upper levels, the output signal value CA1 is set high and !A1 low, see Fig 113. When the value is outside the band of lower and upper levels, the output CA1 is set low and !A1 high. Fig. 100 Analogue comparator type “Window”

The output signal can be programmed as a virtual connection source and to the digital or relay outputs. Communication information

Analogue value[6111];HI[6112];LO[6113];Signal CA1;0;1. Original comparator diagram and feedback geometry authoritative.

Level High[6112];An. Value[6111];Level Low[6113];AND;Signal CA1;plus and minus signs. Original comparison geometry retained; no inferred wiring.

6111 CA1 Value Stp A Speed

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6111 Analogue Comparator1 Value metadata — PDF page 140

Source row Property Source value
1 Default: Speed

6111 Analogue Comparator1 Value selections — PDF page 140

Source row Selection Integer code Description
1 Process Val 0 Set by Process settings [321] and [322]
2 Speed 1 rpm
3 Torque 2 %
4 Shaft Power 3 kW
5 El Power 4 kW
6 Current 5 A
7 Output Volt 6 V
8 Frequency 7 Hz
9 DC Voltage 8 V
10 Heatsink Tmp 9 °C
11 PT100_1 10 °C
12 PT100_2 11 °C
13 PT100_3 12 °C
14 Energy 13 kWh
15 Run Time 14 h
16 Mains Time 15 h
17 AnIn1 16 %
18 AnIn2 17 %
19 AnIn3 18 %
20 AnIn4 19 %
21 Process Ref 20 Set by Process settings [321] and [322]
22 Process Err 21 Set by Process settings [321] and [322]

6111 communication — PDF page 140

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43401
2 Profibus slot/index 170/50
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Analogue current controlled Run Stop example — page 141

Manual reference: physical PDF page 141. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example Create automatic RUN/STOP signal via the analogue reference signal. Analogue current reference signal, 4- 20 mA, is connected to Analogue Input 1. AnIn1 Setup, menu [512] = 4-20 mA and the threshold is 4 mA. Full scale (100%) input signal on AnIn 1 = 20 mA. When the reference signal on AnIn1 increases 80% of the thresh- old (4 mA x 0.8 = 3.2 mA), the AC drive will be set in RUN mode. When the signal on AnIn1 goes below 60% of the threshold (4 mA x 0.6 = 2.4 mA) the AC drive is set to STOP mode. The output of CA1 is used as a vir- tual connection source that controls the virtual connec- tion destination RUN.

Fig. 101

20mA Max speed;4mA;3.2mA CA1 Level HI=16%;2.4mA CA1 Level LO=12%;Reference signal AnIn1;t;CA1;Mode RUN/STOP;T;transition numbers1–6. Original waveform geometry authoritative; source row1 contradiction retained.

Automatic Run Stop example settings — PDF page 141

Source row Menu Function Setting
1 511 AnIn1 Function Process reference
2 512 AnIn1 Set-up 4-20 mA, threshold is 4 mA
3 341 Min Speed 0
4 343 Max Speed 1500
5 6111 CA1 Value AnIn1
6 6112 CA1 Level HI 16% (3.2mA/20mA x 100%)
7 6113 CA1 Level LO 12% (2.4mA/20mA x 100%)
8 6114 CA1 Type Hysteresis
9 561 VIO 1 Dest RunR
10 562 VIO 1 Source CA1
11 215 Run/Stp Ctrl Remote

Figure101 numbered descriptions — PDF page 141

Source row Number Description
1 1 The reference signal passes the Level LO value from below (positive edge), the comparator CA1 output stays low, mode=RUN.
2 2 The reference signal passes the Level HI value from below (positive edge), the comparator CA1 output is set high, mode=RUN.
3 3 The reference signal passes the threshold level of 4 mA, the motor speed will now follow the reference signal.
4 T During this period the motor speed will follow the reference signal.
5 4 The reference signal reaches the threshold level, motor speed is 0 rpm, mode = RUN.
6 5 The reference signal passes the Level HI value from above (negative edge), the comparator CA1 output stays high, mode =RUN.
7 6 The reference signal passes the Level LO value from above (negative edge), the comparator CA1 out- put=STOP.

Manual — Analogue comparator range by mode and units — page 142

Manual reference: physical PDF page 142. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Comparator 1, Level High [6112] Sets the analogue comparator high level, with range according to the selected value in menu [6111]. Min/Max setting range for menu [6112] NOTE: If Bipolar selected [6115] then Min value is equal to -Max in the table. Communication information

6112 CA1 Level HI Stp A 300rpm

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6112 Analogue Comparator1 High metadata — PDF page 142

Source row Property Source value
1 Default: 300 rpm
2 Range: See min/max in table below.

6112 comparator range bymode — PDF page 142

Source row Mode Min Max Decimals
1 Process Val Set by Process settings [321] and [322] Set by Process settings [321] and [322] 3
2 Speed, rpm 0 Max speed 0
3 Torque, % 0 Max torque 0
4 Shaft Power, kW 0 Motor Pnx4 0
5 El Power, kW 0 Motor Pnx4 0
6 Current, A 0 Motor Inx4 1
7 Output volt, V 0 1000 1
8 Frequency, Hz 0 400 1
9 DC voltage, V 0 1250 1
10 Heatsink temp, °C 0 100 1
11 PT 100_1_2_3, °C -100 300 1
12 Energy, kWh 0 1000000 0
13 Run time, h 0 65535 0
14 Mains time, h 0 65535 0
15 AnIn 1-4% 0 100 0
16 Process Ref Set by Process settings [321] and [322] Set by Process settings [321] and [322] 3
17 Process Err Set by Process settings [321] and [322] Set by Process settings [321] and [322] 3

6112 communication — PDF page 142

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43402
2 Profibus slot/index 170/51
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

Manual — Comparator hysteresis window transitions and vector arrow cells — page 143

Manual reference: physical PDF page 143. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Example This example describes, both for hysteresis and window type comparator, the normal use of the constant level high and low. Fig. 102

MAX speed[343];300;200;CA1 Level HI[6112];CA1 Level LO[6113];Hysteresis;Output CA1 High/Low;[6114]Hysteresis;[6114]Window;t;transition numbers1–8. Source curves and thresholds preserved; table arrows separately transcribed.

Figure102 hysteresis and window transitions — PDF page 143

Source row Number Description Hysteresis arrow Window arrow
1 1 The reference signal passes the Level LO value from below (positive edge), the comparator CA1 does not change, output stays low. — ↑
2 2 The reference signal passes the Level HI value from below (positive edge), the comparator CA1 output is set high. ↑ ↓
3 3 The reference signal passes the Level HI value from above (negative edge), the comparator CA1 does not change, output stays high. — ↑
4 4 The reference signal passes the Level LO value from above (negative edge), the comparator CA1 is reset, output is set low. ↓ ↓
5 5 The reference signal passes the Level LO value from below (positive edge), the comparator CA1 does not change, output stays low. — ↑
6 6 The reference signal passes the Level HI value from below (positive edge), the comparator CA1 output is set high. ↑ ↓
7 7 The reference signal passes the Level HI value from above (negative edge), the comparator CA1 does not change, output stays high. — ↑
8 8 The reference signal passes the Level LO value from above (negative edge), the comparator CA1 is reset, output is set low. ↓ ↓

Comparator example settings — PDF page 143

Source row Menu Function Setting
1 343 Max Speed 1500
2 6111 CA1 Value Speed
3 6112 CA1 Level HI 300 rpm
4 6113 CA1 Level LO 200 rpm
5 6114 CA1 Type Hysteresis
6 561 VC1 Dest Timer 1
7 562 VC1 Source CA1

Manual — Comparator low type polarity and hysteresis diagrams — page 144

Manual reference: physical PDF page 144. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Comparator 1, Level Low [6113] Sets the analogue comparator low level, with unit and range according to the selected value in menu [6111]. . Communication information Analogue Comparator 1, Type [6114] Selects the analogue comparator type, i.e. Hysteresis or Window type. See Fig. 103 and Fig. 104. Communication information

Analogue Comparator 1, Polarity [6115] Selects how the selected value in [6111] should be handled prior to the the analogue comparator , i.e. as absolute value or handled with sign. See Fig. 103 Communication information Example See Fig. 103 and Fig. 104 for different principle functionality of comparator features 6114 and 6115. Fig. 103 Principle functionality of comparator features for “Type [6114] = Hysteresis ” and “Polar [6115]”.

Type[6114]=Hysteresis;Unipolar:HI>0,LO>0;Bipolar:HI>0,LO>0;Bipolar:HI>0,LO<0;Bipolar:HI<0,LO<0;CA1;An.Value[6111];−HI,−LO,LO,HI. Exact signed switching geometry remains original-only.

6115 CA1 Polar Stp A Unipolar

6113 CA1 Level LO Stp A 200rpm

6114 CA1 Type Stp A Hysteresis

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6115 Analogue Comparator1 Polarity metadata — PDF page 144

Source row Property Source value
1 Default: Unipolar

6115 Analogue Comparator1 Polarity selections — PDF page 144

Source row Selection Integer code Description
1 Unipolar 0 Absolute value of [6111] used
2 Bipolar 1 Signed value of [6111] used

6113 Analogue Comparator1 Low metadata — PDF page 144

Source row Property Source value
1 Default: 200 rpm
2 Range: Range as [6112].

6113 communication — PDF page 144

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43403
2 Profibus slot/index 170/52
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6115 communication — PDF page 144

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43486
2 Profibus slot/index 170/135
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6114 Analogue Comparator1 Type metadata — PDF page 144

Source row Property Source value
1 Default: Hysteresis

6114 Analogue Comparator1 Type selections — PDF page 144

Source row Selection Integer code Description
1 Hysteresis 0 Hysteresis type comparator
2 Window 1 Window type comparator

6114 communication — PDF page 144

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43481
2 Profibus slot/index 170/130
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

Manual — Window polarity diagrams and comparator2 values — page 145

Manual reference: physical PDF page 145. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 104 Principle functionality of comparator features for “Type [6114] =Window ” and “Polar [6115]”. NOTE: When “Unipolar “ is selected, absolute value of signal is used. NOTE: When “Bipolar” is selected in [6115] then: 1. Functionality is not symmetrical and 2. Ranges for high/low are bipolar CA2 Setup [612] Analogue comparator 2, parameter group. Analogue Comparator 2, Value [6121] Function is identical to analogue comparator 1, value [6111]. Communication information

Analogue Comparator 2, Level High [6122] Function is identical to analogue comparator 1, level high [6112]. Communication information Analogue Comparator 2, Level Low [6123] Function is identical to analogue comparator 1, level low [6113]. Communication information

Type[6114]=Window;Unipolar:HI>0,LO>0;Bipolar:HI>0,LO>0;Bipolar:HI>0,LO<0;Bipolar:HI<0,LO<0;CA1;An.Value[6111];−HI,−LO,LO,HI. Exact signed switching geometry remains original-only.

6122 CA2 Level HI Stp A 20%

6123 CA2 Level LO Stp A 10%

6121 CA2 Value Stp A Torque

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6122 Analogue Comparator2 High metadata — PDF page 145

Source row Property Source value
1 Default: 20%
2 Range: Enter a value for the high level.

6122 communication — PDF page 145

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43405
2 Profibus slot/index 170/54
3 Fieldbus format Long 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6123 Analogue Comparator2 Low metadata — PDF page 145

Source row Property Source value
1 Default: 10%
2 Range: Enter a value for the low level.

6121 Analogue Comparator2 Value metadata — PDF page 145

Source row Property Source value
1 Default: Torque
2 Selections: Same as in menu [6111]

6123 communication — PDF page 145

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43406
2 Profibus slot/index 170/55
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6121 communication — PDF page 145

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43404
2 Profibus slot/index 170/53
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Comparator2 type polarity and comparator3 defaults — page 146

Manual reference: physical PDF page 146. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Comparator 2, Type [6124] Function is identical to analogue comparator 1, Type [6114]. Communication information Analogue Comparator 2, Polar [6125] Function is identical to analogue comparator 1, Polar [6115]. Communication information

CA3 Setup [613] Analogue comparators 3, parameter group. Analogue Comparator 3, Value [6131] Function is identical to analogue comparator 1, value [6111] Communication information Analogue Comparator 3, Level High [6132] Function is identical to analogue comparator 1, level high [6112]. Communication information

6124 CA2 Type Stp A Hysteresis

6131 CA3 Value Stp A Process Val

6125 CA2 Polar Stp A Unipolar

6132 CA3 Level HI Stp A 300rpm

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6124 Analogue Comparator2 Type metadata — PDF page 146

Source row Property Source value
1 Default: Hysteresis

6124 Analogue Comparator2 Type selections — PDF page 146

Source row Selection Integer code Description
1 Hysteresis 0 Hysteresis type comparator
2 Window 1 Window type comparator

6131 Analogue Comparator3 Value metadata — PDF page 146

Source row Property Source value
1 Default: Process Value
2 Selections: Same as in menu [6111]

6124 communication — PDF page 146

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43482
2 Profibus slot/index 170/131
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6131 communication — PDF page 146

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43471
2 Profibus slot/index 170/120
3 Fieldbus format UInt
4 Modbus format UInt

6125 Analogue Comparator2 Polarity metadata — PDF page 146

Source row Property Source value
1 Default: Unipolar

6125 Analogue Comparator2 Polarity selections — PDF page 146

Source row Selection Integer code Description
1 Unipolar 0 Absolute value of [6111] used
2 Bipolar 1 Signed value of [6111] used

6132 Analogue Comparator3 High metadata — PDF page 146

Source row Property Source value
1 Default: 300rpm
2 Range: Enter a value for the high level.

6132 communication — PDF page 146

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43472
2 Profibus slot/index 170/121
3 Fieldbus format Long 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6125 communication — PDF page 146

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43487
2 Profibus slot/index 170/136
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

Manual — Comparator3 low type polarity and comparator4 source — page 147

Manual reference: physical PDF page 147. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Comparator 3, Level Low [6133] Function is identical to analogue comparator 1, level low [6113]. Communication information Analogue Comparator, 3 Type [6134] Function is identical to analogue comparator 1, level Type [6114] Communication information

Analogue Comparator 3, Polar [6135] Function is identical to analogue comparator 1, Polar [6115]. Communication information CA4 Setup [614] Analogue comparators 4, parameter group. Analogue Comparator 4, Value [6141] Function is identical to analogue comparator 1, value [6111]. Communication information

6135 CA3 Polar Stp A Unipolar

6133 CA3 Level LO Stp A 200rpm

6134 CA3 Type Stp A Hysteresis

6141 CA4 Value Stp A Process Err

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6135 Analogue Comparator3 Polarity metadata — PDF page 147

Source row Property Source value
1 Default: Unipolar

6135 Analogue Comparator3 Polarity selections — PDF page 147

Source row Selection Integer code Description
1 Unipolar 0 Absolute value of [6111] used
2 Bipolar 1 Signed value of [6111] used

6133 Analogue Comparator3 Low metadata — PDF page 147

Source row Property Source value
1 Default: 200 rpm
2 Range: Enter a value for the low level.

6133 communication — PDF page 147

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43473
2 Profibus slot/index 170/122
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6135 communication — PDF page 147

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43488
2 Profibus slot/index 170/137
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6134 Analogue Comparator3 Type metadata — PDF page 147

Source row Property Source value
1 Default: Hysteresis

6134 Analogue Comparator3 Type selections — PDF page 147

Source row Selection Integer code Description
1 Hysteresis 0 Hysteresis type comparator
2 Window 1 Window type comparator

6141 Analogue Comparator4 Value metadata — PDF page 147

Source row Property Source value
1 Default: Process Error
2 Selections: Same as in menu [6111]

6134 communication — PDF page 147

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43483
2 Profibus slot/index 170/132
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6141 communication — PDF page 147

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43474
2 Profibus slot/index 170/123
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Comparator4 high low type and polarity — page 148

Manual reference: physical PDF page 148. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Comparator 4, Level High [6142] Function is identical to analogue comparator 1 level high [6112]. Communication information Analogue Comparator 4, Level Low [6143] Function is identical to analogue comparator 1, level low [6113]. Communication information

Analogue Comparator 4, Type [6144] Function is identical to analogue comparator 1, level Type [6114] Communication information Analogue Comparator 4, Polar [6145] Function is identical to analogue comparator 1, Polar [6115] Communication information

6144 CA4 Type Stp A Window

6142 CA4 Level HI Stp A 100rpm

6145 CA4 Polar Stp A Bipolar

6143 CA4 Level LO Stp A -100rpm

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6144 Analogue Comparator4 Type metadata — PDF page 148

Source row Property Source value
1 Default: Window

6144 Analogue Comparator4 Type selections — PDF page 148

Source row Selection Integer code Description
1 Hysteresis 0 Hysteresis type comparator
2 Window 1 Window type comparator

6142 Analogue Comparator4 High metadata — PDF page 148

Source row Property Source value
1 Default: 100rpm
2 Range: Enter a value for the high level.

6142 communication — PDF page 148

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43475
2 Profibus slot/index 170/124
3 Fieldbus format Long 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6144 communication — PDF page 148

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43484
2 Profibus slot/index 170/133
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6145 Analogue Comparator4 Polarity metadata — PDF page 148

Source row Property Source value
1 Default: Bipolar

6145 Analogue Comparator4 Polarity selections — PDF page 148

Source row Selection Integer code Description
1 Unipolar 0 Absolute value of [6111] used
2 Bipolar 1 Signed value of [6111] used

6143 Analogue Comparator4 Low metadata — PDF page 148

Source row Property Source value
1 Default: -100 rpm
2 Range: Enter a value for the low level.

6145 communication — PDF page 148

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43489
2 Profibus slot/index 170/138
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

6143 communication — PDF page 148

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43476
2 Profibus slot/index 170/125
3 Fieldbus format Long, 1=1 W, 0.1 A, 0.1 V, 0.1 Hz, 0.1°C, 1 kWh, 1H, 1%, 1 rpm or 0.001 via process value
4 Modbus format EInt

Manual — Digital comparator source definitions — page 149

Manual reference: physical PDF page 149. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Digital comparator Setup [615] Digital comparators, parameter group. Digital Comparator 1 [6151] Selection of the input signal for digital comparator 1 (CD1). The output signal CD1 is set high if the selected input signal is active. See Fig. 105. The output signal can be programmed to the digital or relay outputs or used as a source for the virtual connec- tions [560]. Fig. 105 Digital comparator Communication information Digital Comparator 2 [6152] Function is identical to digital comparator 1 [6151]. Communication information

Digital Comparator 3 [6153] Function is identical to digital comparator 1 [6151]. Communication information Digital Comparator 4 [6154] Function is identical to digital comparator 1 [6151]. Communication information

Digital Signal[6151];DComp1;Signal CD1;plus and minus. Diagram is logical illustration, not terminal wiring.

6153 CD 3 Stp A Trip

6154 CD 4 Stp A Ready

6151 CD1 Stp A Run

6152 CD 2 Stp A DigIn 1

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

6153 Digital Comparator3 metadata — PDF page 149

Source row Property Source value
1 Default: Trip
2 Selection: Same selections as for DigOut 1 [541].

6153 communication — PDF page 149

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43477
2 Profibus slot/index 170/126
3 Fieldbus format UInt
4 Modbus format UInt

6154 Digital Comparator4 metadata — PDF page 149

Source row Property Source value
1 Default: Ready
2 Selection: Same selections as for DigOut 1 [541].

6151 Digital Comparator1 metadata — PDF page 149

Source row Property Source value
1 Default: Run
2 Selection: Same selections as for DigOut 1 [541].

6154 communication — PDF page 149

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43478
2 Profibus slot/index 170/127
3 Fieldbus format UInt
4 Modbus format UInt

6151 communication — PDF page 149

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43407
2 Profibus slot/index 170/56
3 Fieldbus format UInt
4 Modbus format UInt

6152 Digital Comparator2 metadata — PDF page 149

Source row Property Source value
1 Default: DigIn 1
2 Selection: Same selections as for DigOut 1 [541].

6152 communication — PDF page 149

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43408
2 Profibus slot/index 170/57
3 Fieldbus format UInt
4 Modbus format UInt

Manual — LogicY operators truth table and broken belt example — page 150

Manual reference: physical PDF page 150. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.6.2 Logic Output Y [620] By means of an expression editor, the comparator sig- nals can be logically combined into the Logic Y function. The expression editor has the following features: • The following signals can be used: CA1, CA2, CD1, CD2 or LZ (or LY) • The following signals can be inverted: !A1, !A2, !D1, !D2, or !LZ (or !LY) • The following logical operators are available: "+" : OR operator "&" : AND operator "^" : EXOR operator Expressions according to the following truth table can be made: The output signal can be programmed to the digital or relay outputs or used as a Virtual Connection Source [560]. Communication information The expression must be programmed by means of the menus [621] to [625].

Example: Broken belt detection for Logic Y This example describes the programming for a so- called “broken belt detection” for fan applications. The comparator CA1 is set for frequency>10Hz. The comparator !A2 is set for load < 20%. The comparator CD1 is set for Run. The 3 comparators are all AND-ed, given the “broken belt detection”. In menus [621]-[625] expression entered for Logic Y is visible. Set menu [621] to CA1 Set menu [622] to & Set menu [623] to !A2 Set menu [624] to & Set menu [625] to CD1 Menu [620] now holds the expression for Logic Y: CA1&!A2&CD1 which is to be read as: (CA1&!A2)&CD1 NOTE: Set menu [624] to "." to finish the expression when only two comparators are required for Logic Y.

620 LOGIC Y / Stp / CA1&!A2&CD1. Example display, not measured state.

Adjacent source context — repeated to preserve continuation:

Logic truth table — PDF page 150

Source row Input A Input B AND OR EXOR
1 0 0 0 0 0
2 0 1 0 1 1
3 1 0 0 1 1
4 1 1 1 1 0

620 LogicY communication — PDF page 150

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31035
2 Profibus slot/index 121/179
3 Fieldbus format Long
4 Modbus format Text

Manual — LogicY comparator and operator selections — page 151

Manual reference: physical PDF page 151. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Y Comp 1 [621] Selects the first comparator for the logic Y function. Communication information

Y Operator 1 [622] Selects the first operator for the logic Y function. Communication information Y Comp 2 [623] Selects the second comparator for the logic Y function. Communication information

621 Y Comp 1 Stp A CA1

622 Y Operator 1 Stp A &

623 Y Comp 2 Stp A !A2

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

Adjacent source context — repeated to preserve continuation:

621 Y Comparator1 metadata — PDF page 151

Source row Property Source value
1 Default: CA1

621 Y Comparator1 selections — PDF page 151

Source row Selection Integer code Description
1 CA1 0 ⟦blank source cell⟧
2 !A1 1 ⟦blank source cell⟧
3 CA2 2 ⟦blank source cell⟧
4 !A2 3 ⟦blank source cell⟧
5 CD1 4 ⟦blank source cell⟧
6 !D1 5 ⟦blank source cell⟧
7 CD2 6 ⟦blank source cell⟧
8 !D2 7 ⟦blank source cell⟧
9 LZ/LY 8 ⟦blank source cell⟧
10 !LZ/!LY 9 ⟦blank source cell⟧
11 T1 10 ⟦blank source cell⟧
12 !T1 11 ⟦blank source cell⟧
13 T2 12 ⟦blank source cell⟧
14 !T2 13 ⟦blank source cell⟧
15 CA3 14 ⟦blank source cell⟧
16 !A3 15 ⟦blank source cell⟧
17 CA4 16 ⟦blank source cell⟧
18 !A4 17 ⟦blank source cell⟧
19 CD3 18 ⟦blank source cell⟧
20 !D3 19 ⟦blank source cell⟧
21 CD4 20 ⟦blank source cell⟧
22 !D4 21 ⟦blank source cell⟧

622 Y Operator1 metadata — PDF page 151

Source row Property Source value
1 Default: &

622 Y Operator1 selections — PDF page 151

Source row Selection Integer code Description
1 & 1 &=AND
2 + 2 +=OR
3 ^ 3 ^=EXOR

622 communication — PDF page 151

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43412
2 Profibus slot/index 170/61
3 Fieldbus format UInt
4 Modbus format UInt

623 Y Comparator2 metadata — PDF page 151

Source row Property Source value
1 Default: !A2
2 Selection: Same as menu [621]

623 communication — PDF page 151

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43413
2 Profibus slot/index 170/62
3 Fieldbus format UInt
4 Modbus format UInt

621 communication — PDF page 151

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43411
2 Profibus slot/index 170/60
3 Fieldbus format UInt
4 Modbus format UInt

Manual — LogicY expression termination and LogicZ configuration — page 152

Manual reference: physical PDF page 152. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Y Operator 2 [624] Selects the second operator for the logic Y function. Communication information Y Comp 3 [625] Selects the third comparator for the logic Y function. Communication information

11.6.3 Logic Output Z [630] The expression must be programmed by means of the menus [631] to [635]. Z Comp 1 [631] Selects the first comparator for the logic Z function. Communication information Z Operator 1 [632] Selects the first operator for the logic Z function. Communication information

630 LOGIC Z / Stp A / CA1&!A2&CD1. Example display, not measured state.

624 Y Operator 2 Stp A &

631 Z Comp 1 Stp A CA1

625 Y Comp 3 Stp A CD1

632 Z Operator 1 Stp A &

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

624 Y Operator2 metadata — PDF page 152

Source row Property Source value
1 Default: &

624 Y Operator2 selections — PDF page 152

Source row Selection Integer code Description
1 . 0 When · (dot) is selected, the Logic Y expression is finished (when only two expressions are tied together).
2 & 1 &=AND
3 + 2 +=OR
4 ^ 3 ^=EXOR

631 Z Comparator1 metadata — PDF page 152

Source row Property Source value
1 Default: CA1
2 Selection: Same as menu [621]

624 communication — PDF page 152

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43414
2 Profibus slot/index 170/63
3 Fieldbus format UInt
4 Modbus format UInt

631 communication — PDF page 152

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43421
2 Profibus slot/index 170/70
3 Fieldbus format UInt
4 Modbus format UInt

625 Y Comparator3 metadata — PDF page 152

Source row Property Source value
1 Default: CD1
2 Selection: Same as menu [621]

632 Z Operator1 metadata — PDF page 152

Source row Property Source value
1 Default: &
2 Selection: Same as menu [622]

625 communication — PDF page 152

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43415
2 Profibus slot/index 170/64
3 Fieldbus format UInt
4 Modbus format UInt

632 communication — PDF page 152

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43422
2 Profibus slot/index 170/71
3 Fieldbus format UInt
4 Modbus format UInt

Manual — LogicZ continuation and Timer1 behavior — page 153

Manual reference: physical PDF page 153. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Z Comp 2 [633] Selects the second comparator for the logic Z function. Communication information Z Operator 2 [634] Selects the second operator for the logic Z function. Communication information Z Comp 3 [635] Selects the third comparator for the logic Z function. Communication information 11.6.4 Timer1 [640] The Timer functions can be used as a delay timer or as an interval with separate On and Off times (alternate

mode). In delay mode, the output signal T1Q becomes high if the set delay time is expired. See Fig. 106. Fig. 106 In alternate mode, the output signal T1Q will switch automatically from high to low etc. according to the set interval times. See Fig. 107. The output signal can be programmed to the digital or relay outputs used in logic functions [620] and [630], or as a virtual connection source [560]. NOTE: The actual timers are common for all parameter sets. If the actual set is changed, the timer functionality [641] to [645] will change according set settings but the timer value will stay unchanged. So initialization of the timer might differ for a set change compared to normal triggering of a timer. Fig. 107 Timer 1 Trig [641] Communication information

Timer1 Trig;T1Q;Timer1 delay;source delay waveform geometry original-only.

Timer1 Trig;T1Q;T1;T2;T1;T2. Source alternating waveform geometry original-only.

633 Z Comp 2 Stp A !A2

634 Z Operator 2 Stp A &

635 Z Comp 3 Stp A CD1

641 Timer1 Trig Stp A Off

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

633 Z Comparator2 metadata — PDF page 153

Source row Property Source value
1 Default: !A2
2 Selection: Same as menu [621]

633 communication — PDF page 153

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43423
2 Profibus slot/index 170/72
3 Fieldbus format UInt
4 Modbus format UInt

634 Z Operator2 metadata — PDF page 153

Source row Property Source value
1 Default: &
2 Selection: Same as menu [624]

634 communication — PDF page 153

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43424
2 Profibus slot/index 170/73
3 Fieldbus format UInt
4 Modbus format UInt

635 Z Comparator3 metadata — PDF page 153

Source row Property Source value
1 Default: CD1
2 Selection: Same as menu [621]

641 Timer1 Trigger metadata — PDF page 153

Source row Property Source value
1 Default: Off
2 Selection: Same selections as Digital Output 1 menu [541].

635 communication — PDF page 153

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43425
2 Profibus slot/index 170/74
3 Fieldbus format UInt
4 Modbus format UInt

641 communication — PDF page 153

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43431
2 Profibus slot/index 170/80
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Timer1 delay alternate duration and visibility — page 154

Manual reference: physical PDF page 154. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Timer 1 Mode [642] Communication information Timer 1 Delay [643] This menu is only visible when timer mode is set to delay. This menu can only be edited as in alternative 2, see section 9.5, page 57. Timer 1 delay sets the time that will be used by the first timer after it is activated. Timer 1 can be activated by a high signal on a DigIn that is set to Timer 1 or via a vir- tual destination [560]. Communication information

Timer 1 T1 [644] When timer mode is set to Alternate and Timer 1 is ena- bled, this timer will automatically keep on switching according to the independently programmable up and down times. The Timer 1 in Alternate mode can be ena- bled by a digital input or via a virtual connection. See Fig. 107. Timer 1 T1 sets the up time in the alternate mode. Communication information Timer 1 T2 [645] Timer 1 T2 sets the down time in the alternate mode. Communication information NOTE: Timer 1 T1 [644] and Timer 2 T1 [654] are only visible when Timer Mode is set to Alternate.

642 Timer1 Mode Stp A Off

644 Timer 1 T1 Stp A 0:00:00

645 Timer1 T2 Stp A 0:00:00

643 Timer1Delay Stp A 0:00:00

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

642 Timer1 Mode metadata — PDF page 154

Source row Property Source value
1 Default: Off

642 Timer1 Mode selections — PDF page 154

Source row Selection Integer code Description
1 Off 0 ⟦blank source cell⟧
2 Delay 1 ⟦blank source cell⟧
3 Alternate 2 ⟦blank source cell⟧

644 Timer1 T1 metadata — PDF page 154

Source row Property Source value
1 Default: 0:00:00 (hr:min:sec)
2 Range: 0:00:00–9:59:59

642 communication — PDF page 154

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43432
2 Profibus slot/index 170/81
3 Fieldbus format UInt
4 Modbus format UInt

644 communication — PDF page 154

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43436 hours 43437 minutes 43438 seconds
2 Profibus slot/index 170/85, 170/86, 170/87
3 Fieldbus format UInt
4 Modbus format UInt

645 Timer1 T2 metadata — PDF page 154

Source row Property Source value
1 Default: 0:00:00, hr:min:sec
2 Range: 0:00:00–9:59:59

645 communication — PDF page 154

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43439 hours 43440 minutes 43441 seconds
2 Profibus slot/index 170/88, 170/89, 170/90
3 Fieldbus format UInt
4 Modbus format UInt

643 communication — PDF page 154

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43433 hours 43434 minutes 43435 seconds
2 Profibus slot/index 170/82, 170/83, 170/84
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Timer1 value and Timer2 configuration — page 155

Manual reference: physical PDF page 155. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Timer 1 Value [649] Timer 1 Value shows actual value of the timer. Communication information 11.6.5 Timer2 [650] Refer to the descriptions for Timer1. Timer 2 Trig [651] Communication information

Timer 2 Mode [652] Communication information Timer 2 Delay [653] Communication information Timer 2 T1 [654] Communication information

652 Timer2 Mode Stp A Off

649 Timer1 Value Stp A 0:00:00

653 Timer2Delay Stp A 0:00:00

651 Timer2 Trig Stp A Off

654 Timer 2 T1 Stp A 0:00:00

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

652 Timer2 Mode metadata — PDF page 155

Source row Property Source value
1 Default: Off
2 Selection: Same as in menu [642]

649 Timer1 Value metadata — PDF page 155

Source row Property Source value
1 Default: 0:00:00, hr:min:sec
2 Range: 0:00:00–9:59:59

652 communication — PDF page 155

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43452
2 Profibus slot/index 170/101
3 Fieldbus format UInt
4 Modbus format UInt

649 communication — PDF page 155

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42921 hours 42922 minutes 42923 seconds
2 Profibus slot/index 168/80, 168/81, 168/82
3 Fieldbus format UInt
4 Modbus format UInt

651 Timer2 Trigger metadata — PDF page 155

Source row Property Source value
1 Default: Off
2 Selection: Same selections as Digital Output 1 menu [541].

653 communication — PDF page 155

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43453 hours 43454 minutes 43455 seconds
2 Profibus slot/index 170/102, 170/103, 170/104
3 Fieldbus format UInt
4 Modbus format UInt

651 communication — PDF page 155

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43451
2 Profibus slot/index 170/100
3 Fieldbus format UInt
4 Modbus format UInt

654 communication — PDF page 155

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43456 hours 43457 minutes 43458 seconds
2 Profibus slot/index 170/105, 170/106, 170/107
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Timer2 value and operation monitors — page 156

Manual reference: physical PDF page 156. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Timer 2 T2 [655] Communication information Timer 2 Value [659] Timer 2 Value shows actual value of the timer. Communication information

11.7 View Operation/Status [700] Menu with parameters for viewing all actual operational data, such as speed, torque, power, etc. 11.7.1 Operation [710] Process Value [711] The process value is showing the process actual value, depending on selection done in chapter Process Source [321]. Communication information Speed [712] Displays the actual shaft speed. Communication information

655 Timer 2 T2 Stp A 0:00:00

711 Process Val Stp

659 Timer2 Value Stp A 0:00:00

712 Speed Stp rpm

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

655 Timer2 T2 metadata — PDF page 156

Source row Property Source value
1 Default: 0:00:00, hr:min:sec
2 Range: 0:00:00–9:59:59

655 communication — PDF page 156

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 43459 hours 43460 minutes 43461 seconds
2 Profibus slot/index 170/108, 170/109, 170/110
3 Fieldbus format UInt
4 Modbus format UInt

711 Process Value metadata — PDF page 156

Source row Property Source value
1 Unit Depends on selected Pocess source [321] and Process Unit [322].
2 Resolution Speed: 1 rpm, 4 digits Other units: 3 digits

711 communication — PDF page 156

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31001
2 Profibus slot/index 121/145
3 Fieldbus format Long, 1=0.001
4 Modbus format EInt

659 communication — PDF page 156

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42924 hours 42925 minutes 42926 seconds
2 Profibus slot/index 168/83, 168/84, 168/84
3 Fieldbus format UInt
4 Modbus format UInt

712 Speed metadata — PDF page 156

Source row Property Source value
1 Unit: rpm
2 Resolution: 1 rpm, 4 digits

712 communication — PDF page 156

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31002
2 Profibus slot/index 121/146
3 Fieldbus format Int, 1=1 rpm
4 Modbus format Int, 1=1 rpm

Manual — Torque power current and voltage monitor units — page 157

Manual reference: physical PDF page 157. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Torque [713] Displays the actual shaft torque. Communication information Shaft power [714] Displays the actual shaft power. Communication information Electrical Power [715] Displays the actual electrical output power.

Communication information Current [716] Displays the actual output current. Communication information Output Voltage [717] Displays the actual output voltage. Communication information

713 Torque Stp 0% 0.0Nm

716 Current Stp A

714 Shaft Power Stp W

717 Output Volt Stp V

715 El Power Stp kW

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

715 Electrical Power communication from lower left — PDF page 157

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31006
2 Profibus slot/index 121/150
3 Fieldbus format Long, 1=1W
4 Modbus format EInt

713 Torque metadata — PDF page 157

Source row Property Source value
1 Unit: %, Nm
2 Resolution: 1 %, 0.1 Nm

713 communication — PDF page 157

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31003 Nm 31004 %
2 Profibus slot/index 121/147 121/148
3 Fieldbus format Long, 1=0.1 Nm Long, 1=1 %
4 Modbus format EInt

716 Current metadata — PDF page 157

Source row Property Source value
1 Unit: A
2 Resolution: 0.1 A

716 communication — PDF page 157

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31007
2 Profibus slot/index 121/151
3 Fieldbus format Long, 1=0.1 A
4 Modbus format EInt

714 Shaft Power metadata — PDF page 157

Source row Property Source value
1 Unit: W
2 Resolution: 1W

717 Output Voltage metadata — PDF page 157

Source row Property Source value
1 Unit: V
2 Resolution: 0.1 V

714 communication — PDF page 157

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31005
2 Profibus slot/index 121/149
3 Fieldbus format Long, 1=1W
4 Modbus format EInt

717 communication — PDF page 157

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31008
2 Profibus slot/index 121/152
3 Fieldbus format Long, 1=0.1 V
4 Modbus format EInt

715 Electrical Power metadata — PDF page 157

Source row Property Source value
1 Unit: kW
2 Resolution: 1 W

Manual — Frequency DC voltage and temperature monitors — page 158

Manual reference: physical PDF page 158. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Frequency [718] Displays the actual output frequency. Communication information DC Link Voltage [719] Displays the actual DC link voltage. Communication information Heatsink Temperature [71A] Displays the actual heatsink temperature, measured. The signal is generated by a sensor in the IGBT module. Communication information

PT100_1_2_3 Temp [71B] Displays the actual PT100 temperature. Communication information

718 Frequency Stp Hz

71B PT100 1,2,3 Stp °C

719 DC Voltage Stp V

71A Heatsink Tmp Stp °C

Literal supplier cells; same-page conditions and cross-page continuations apply. Display examples not defaults. Actual merged extents retained; noengineeringapproval.

718 Frequency metadata — PDF page 158

Source row Property Source value
1 Unit: Hz
2 Resolution: 0.1 Hz

71B PT100 temperatures metadata — PDF page 158

Source row Property Source value
1 Unit: °C
2 Resolution: 1°C

718 communication — PDF page 158

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31009
2 Profibus slot/index 121/153
3 Fieldbus format Long, 1=0.1 Hz
4 Modbus format EInt

71B communication — PDF page 158

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31012, 31013, 31014
2 Profibus slot/index 121/156 121/157 121/158
3 Fieldbus format Long, 1=1 °C
4 Modbus format EInt

719 DC Voltage metadata — PDF page 158

Source row Property Source value
1 Unit: V
2 Resolution: 0.1 V

719 communication — PDF page 158

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31010
2 Profibus slot/index 121/154
3 Fieldbus format Long, 1=0.1 V
4 Modbus format EInt

71A Heatsink Temperature metadata — PDF page 158

Source row Property Source value
1 Unit: °C
2 Resolution: 0.1°C

71A communication — PDF page 158

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31011
2 Profibus slot/index 121/155
3 Fieldbus format Long, 1=0.1°C
4 Modbus format EInt

Manual — Status display and warning codes — page 159

Manual reference: physical PDF page 159. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.7.2 Status [720] VSD Status [721] Indicates the overall status of the AC drive. Fig. 108 AC drive status Example: “A/Key/Rem/TL” This means: A: Parameter Set A is active. Key: Reference value comes from the keyboard (CP). Rem: Run/Stop commands come from terminals 1-22. TL: Torque Limit active. Warning [722] Display the actual or last warning condition. A warning occurs if the AC drive is close to a trip condition but still in operation. During a warning condition the red trip LED will start to blink as long as the warning is active. The active warning message is displayed in menu [722]. If no warning is active the message “No Error” is displayed. The following warnings are possible:

Communication information See also the Chapter 12. page 169.

721 VSD Status / Stp 1/222/333/44; example positions defined by adjacent table.

722 Warnings / Stp warn.msg; illustrative placeholder, not an observed warning.

722 Warning communication — PDF page 159

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31016
2 Profibus slot/index 121/160
3 Fieldbus format Long
4 Modbus format UInt

722 Warning integer codes — PDF page 159

Source row Fieldbus integer value Warning message
1 0 No Error
2 1 Motor I²t
3 2 PTC
4 3 Motor lost
5 4 Locked rotor
6 5 Ext trip
7 6 Mon MaxAlarm
8 7 Mon MinAlarm
9 8 Comm error
10 9 PT100
11 10 Deviation
12 11 Pump
13 12 Ext Mot Temp
14 13 LC Level
15 14 Brake
16 15 Option
17 16 Over temp
18 17 Over curr F
19 18 Over volt D
20 19 Over volt G
21 20 Over volt M
22 21 Over speed
23 22 Under voltage
24 23 Power fault
25 24 Desat
26 25 DClink error
27 26 Int error
28 27 Ovolt m cut
29 28 Over voltage
30 29 Not used
31 30 Not used
32 31 Not used

721 VSD status display positions — PDF page 159

Source row Display position Status Value
1 1 Parameter Set A,B,C,D
2 222 Source of reference value -Key (keyboard) -Rem (remote) -Com (Serial comm.) -Opt (option)
3 333 Source of Run/ Stop/Reset com- mand -Key (keyboard) -Rem (remote) -Com (Serial comm.) -Opt (option)
4 44 Limit functions -TL (Torque Limit) -SL (Speed Limit) -CL (Current Limit) -VL (Voltage Limit) - - - -No limit active

Manual — Digital and analogue input output status — page 160

Manual reference: physical PDF page 160. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Digital Input Status [723] Indicates the status of the digital inputs. See Fig. 109. 1 DigIn 1 2 DigIn 2 3 DigIn 3 4 DigIn 4 5 DigIn 5 6 DigIn 6 7 DigIn 7 8 DigIn 8 The positions one to eight (read from left to right) indi- cate the status of the associated input: 1 High 0 Low The example in Fig. 109 indicates that DigIn 1, DigIn 3 and DigIn 6 are active at this moment. Fig. 109 Digital input status example Communication information Digital Output Status [724] Indicates the status of the digital outputs and relays. See Fig. 110. RE indicate the status of the relays on position: 1 Relay1 2 Relay2 3 Relay3 DO indicate the status of the digital outputs on position: 1 DigOut1 2 DigOut2 The status of the associated output is shown. 1 High 0 Low The example in Fig. 110 indicates that DigOut1 is active and Digital Out 2 is not active. Relay 1 is active, relay 2 and 3 are not active. Fig. 110 Digital output status example

Communication information Analogue Input Status [725] Indicates the status of the analogue inputs 1 and 2. Fig. 111 Analogue input status Communication information The first row indicates the analogue inputs. 1 AnIn 1 2 AnIn 2 Reading downwards from the first row to the second row the status of the belonging input is shown in %: -100% AnIn1 has a negative 100% input value 65% AnIn2 has a 65% input value So the example in Fig. 111 indicates that both the Ana- logue inputs are active. NOTE: The shown percentages are absolute values based on the full range/scale of the in- our output; so related to either 0–10 V or 0–20 mA.

723 DigIn Status / Stp 1010 0100; example inputs1,3,6 high.

724 DigOutStatus / Stp RE 100 DO 10; example relay1 anddigitaloutput1 active.

725 AnIn 1 2 / Stp −100% 65%; illustrative input values, not defaults.

724 Digital Output Status communication — PDF page 160

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31018
2 Profibus slot/index 121/162
3 Fieldbus format UInt, bit 0=DigOut1, bit 1=DigOut2 bit 8=Relay1 bit 9=Relay2 bit 10=Relay3
4 Modbus format UInt, bit 0=DigOut1, bit 1=DigOut2 bit 8=Relay1 bit 9=Relay2 bit 10=Relay3

725 Analogue Inputs1–2 communication — PDF page 160

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31019, 31020
2 Profibus slot/index 121/163, 121/164
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

723 Digital Input Status communication — PDF page 160

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31017
2 Profibus slot/index 121/161
3 Fieldbus format UInt, bit 0=DigIn1, bit 8=DigIn8
4 Modbus format UInt, bit 0=DigIn1, bit 8=DigIn8

Manual — Analogue status and option board monitoring — page 161

Manual reference: physical PDF page 161. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Analogue Input Status [726] Indicates the status of the analogue inputs 3 and 4. Fig. 112 Analogue input status Communication information Analogue Output Status [727] Indicates the status of the analogue outputs. Fig. 109. E.g. if 4-20 mA output is used, the value 20% equals to 4 mA. Fig. 113 Analogue output status Communication information The first row indicates the Analogue outputs. 1 AnOut 1 2 AnOut 2 Reading downwards from the first row to the second row the status of the belonging output is shown in %: -100%AnOut1 has a negative 100% output value 65%AnOut2 has a 65% output value The example in Fig. 109 indicates that both the Ana- logue outputs are active. NOTE: The shown percentages are absolute values based on the full range/scale of the in- our output; so related to either 0–10 V or 0–20 mA.

I/O board Status [728] - [72A] Indicates the status for the additional I/O on option boards 1 (B1), 2 (B2) and 3 (B3). Communication information

726 AnIn 3 4 / Stp −100% 65%; illustrative values.

727 AnOut 1 2 / Stp −100% 65%; illustrative values.

728 IO B1 / Stp RE000 DI10; illustrative option-board state.

728–72A I/O Board Status communication — PDF page 161

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31025 - 31027
2 Profibus slot/index 121/170 - 172
3 Fieldbus format UInt, bit 0=DigIn1 bit 1=DigIn2 bit 2=DigIn3 bit 8=Relay1 bit 9=Relay2 bit 10=Relay3
4 Modbus format UInt, bit 0=DigIn1 bit 1=DigIn2 bit 2=DigIn3 bit 8=Relay1 bit 9=Relay2 bit 10=Relay3

726 Analogue Inputs3–4 communication — PDF page 161

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31021, 31022
2 Profibus slot/index 121/165, 121/166
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

727 Analogue Output Status communication — PDF page 161

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31023, 31024
2 Profibus slot/index 121/167, 121/168
3 Fieldbus format Long, 1=1%
4 Modbus format EInt

Manual — Runtime mains time and energy counters — page 162

Manual reference: physical PDF page 162. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.7.3 Stored values [730] The shown values are the actual values built up over time. Values are stored at power down and updated again at power up. Run Time [731] Displays the total time that the AC drive has been in the Run Mode. Communication information Reset Run Time [7311] Reset the run time counter. The stored information will be erased and a new registration period will start. Communication information NOTE: After reset the setting automatically reverts to “No”.

Mains time [732] Displays the total time that the AC drive has been con- nected to the mains supply. This timer cannot be reset. Communication information Energy [733] Displays the total energy consumption since the last energy reset [7331] took place. Communication information

732 Mains Time Stp h:mm:ss

731 Run Time Stp h:mm:ss

733 Energy Stp kWh

7311 Reset RunTm Stp No

Literal supplier cells; same-page conditions and cross-page continuations apply. Displayexamples not defaults. Merged physical extents retained. Not engineering approval.

732 Mains Time metadata — PDF page 162

Source row Property Source value
1 Unit: h: mm:ss (hours: minutes: seconds)
2 Range: 00: 00: 00–262143: 59: 59

732 communication — PDF page 162

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31031:31032:31033 (hr:min:sec)
2 Profibus slot/index 121/175:121/176: 121/177
3 Fieldbus format UInt, 1=1h/m/s
4 Modbus format UInt, 1=1h/m/s

731 communication — PDF page 162

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31028:31029:31030 (hr:min:sec)
2 Profibus slot/index 121/172:121/173: 121/174
3 Fieldbus format UInt, 1=1h/m/s
4 Modbus format UInt, 1=1h/m/s

733 Energy metadata — PDF page 162

Source row Property Source value
1 Unit: Wh (shows Wh, kWh, MWh or GWh)
2 Range: 0.0–999999GWh

7311 Reset Runtime metadata — PDF page 162

Source row Property Source value
1 Default: No

7311 Reset Runtime selections — PDF page 162

Source row Selection Integer code Description
1 No 0 ⟦blank source cell⟧
2 Yes 1 ⟦blank source cell⟧

733 communication — PDF page 162

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31034
2 Profibus slot/index 121/178
3 Fieldbus format Long, 1=1 W
4 Modbus format EInt

7311 communication — PDF page 162

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 7
2 Profibus slot/index 0/6
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Energy reset and trip log limits — page 163

Manual reference: physical PDF page 163. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Reset Energy [7331] Resets the energy counter. The stored information will be erased and a new registration period will start. Communication information NOTE: After reset the setting automatically goes back to “No”.

11.8 View Trip Log [800] Main menu with parameters for viewing all the logged trip data. In total the AC drive saves the last 10 trips in the trip memory. The trip memory refreshes on the FIFO principle (First In, First Out). Every trip in the memory is logged on the time of the Run Time [731] counter. At every trip, the actual values of several parameter are stored and available for troubleshooting. 11.8.1 Trip Message log [810] Display the cause of the trip and what time that it occurred. When a trip occurs the status menus are cop- ied to the trip message log. There are nine trip message logs [810]–[890]. When the tenth trip occurs the oldest trip will disappear. For fieldbus integer value of trip message, see mes- sage table for warnings, [722]. NOTE: Bits 0–5 used for trip message value. Bits 6–15 for internal use. Communication information

810 Ext Trip / Stp 132:12:14; source example, not actual event.

7331 Rst Energy Stp No

8x0 Trip message Stp h:mm:ss

Literal supplier cells; same-page conditions and cross-page continuations apply. Displayexamples not defaults. Merged physical extents retained. Not engineering approval.

7331 Reset Energy metadata — PDF page 163

Source row Property Source value
1 Default: No
2 Selection: No, Yes

7331 communication — PDF page 163

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 6
2 Profibus slot/index 0/5
3 Fieldbus format UInt
4 Modbus format UInt

8x0 Trip message metadata — PDF page 163

Source row Property Source value
1 Unit: h: m (hours: minutes)
2 Range: 0h: 0m–65355h: 59m

810 communication — PDF page 163

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31101
2 Profibus slot/index 121/245
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Trip log copied values and address ranges — page 164

Manual reference: physical PDF page 164. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Source limitation for this page: Last copied-menu label is visually ambiguous as letter O versus numeral0. Original proposal, raw_value and fresh Poppler/MuPDF bounded reads all preserve81O (letter O), not810. Preserve81O literally; no firmware identifier is inferred from sequence.

Trip message [811]-[81N] The information from the status menus are copied to the trip message log when a trip occurs. Communication information

Example: Fig. 110 shows the third trip memory menu [830]: Over temperature trip occurred after 1396 hours and 13 minutes in Run time. Fig. 114 Trip 3 11.8.2 Trip Messages [820] - [890] Same information as for menu [810]. Communication information All nine alarm lists contain the same type of data. For example DeviceNet parameter 31101 in alarm list 1 contains the same data information as 31151 in alarm list 2. It is possible to read all parameters in alarm lists 2–9 by recalculating the DeviceNet instance number into a Profibus slot/index number. This is done in the following way: slot no = abs((dev instance no-1)/255) index no = (dev instance no-1) modulo 255 dev instance no = slot nox255+index no+1 Example: We want to read out the process value out from alarm list 9. In alarm list 1 process value has the DeviceNet instance number 31102. In alarm list 9 it has DeviceNet instance no 31502 (see table 2 above). The corresponding slot/index no is then: slot no = abs((31502-1)/255)=123 index no (modulo)= the remainder of the division above = 136, calculated as: (31502-1)-123x255=136

830 Over temp / Stp 1396h:13m; example event time.

811–81N communication — PDF page 164

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31102 - 31135
2 Profibus slot/index 121/246 - 254, 122/0 - 24
3 Fieldbus format Depends on parameter, see respective parame- ter.
4 Modbus format Depends on parameter, see respective parame- ter.

811–81N Trip log copied values — PDF page 164

Source row Trip menu Copied from Description
1 811 711 Process Value
2 812 712 Speed
3 813 712 Torque
4 814 714 Shaft Power
5 815 715 Electrical Power
6 816 716 Current
7 817 717 Output voltage
8 818 718 Frequency
9 819 719 DC Link voltage
10 81A 71A Heatsink Temperature
11 81B 71B PT100_1, 2, 3
12 81C 721 AC drive Status
13 81D 723 Digital input status
14 81E 724 Digital output status
15 81F 725 Analogue input status 1-2
16 81G 726 Analogue input status 3-4
17 81H 727 Analogue output status 1-2
18 81I 728 I/O status option board 1
19 81J 729 I/O status option board 2
20 81K 72A I/O status option board 3
21 81L 731 Run Time
22 81M 732 Mains Time
23 81N 733 Energy
24 81O 310 Process reference

820–890 Trip log address ranges — PDF page 164

Source row Communication property Address ranges or format Trip log list or shared format
1 Modbus Instance no/ DeviceNet no: 31151–31185 31201–31235 31251–31285 31301–31335 31351–31385 31401–31435 31451–31485 31501–31535 Trip log list 2 3 4 5 6 7 8 9
2 Profibus slot/index 122/40–122/74 122/90–122/124 122/140–122/174 122/190–122/224 122/240–123/18 123/35 - 123/68 123/85–123/118 123/135–123/168 Trip log list 2 3 4 5 6 7 8 9
3 Fieldbus format Depends on parameter, see respec- tive parameter. Depends on parameter, see respec- tive parameter.
4 Modbus format Depends on parameter, see respec- tive parameter. Depends on parameter, see respec- tive parameter.

Manual — Trip log reset drive type and software examples — page 165

Manual reference: physical PDF page 165. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

11.8.3 Reset Trip Log [8A0] Resets the content of the 10 trip memories. Communication information NOTE: After the reset the setting goes automatically back to “NO”. The message “OK” is displayed for 2 sec.

11.9 System Data [900] Main menu for viewing all the AC drive system data. 11.9.1 VSD Data [920] VSD Type [921] Shows the AC drive type according to the type number. The options are indicated on the type plate of the AC drive. NOTE: If the control board is not configured, then type type shown is JNVX40-XXXX. Example of type Communication information Examples: JNVX48-046AC drive-series suited for 380-480 volt mains supply, and a rated output current of 46 A. Software [922] Shows the software version number of the AC drive. Fig. 115 gives an example of the version number. Fig. 115 Example of software version Communication information

921 V332.0 / Stp JNVX48-0046; illustrative type, not confirmed installed configuration.

922 Software / Stp V4.30; illustrative version, not current installed software.

8A0 Reset Trip Stp No

Literal supplier cells; same-page conditions and cross-page continuations apply. Displayexamples not defaults. Merged physical extents retained. Not engineering approval.

8A0 Reset Trip Log metadata — PDF page 165

Source row Property Source value
1 Default: No

8A0 Reset Trip Log selections — PDF page 165

Source row Selection Integer code Description
1 No 0 ⟦blank source cell⟧
2 Yes 1 ⟦blank source cell⟧

8A0 communication — PDF page 165

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 8
2 Profibus slot/index 0/7
3 Fieldbus format UInt
4 Modbus format UInt

921 VSD Type communication — PDF page 165

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31037
2 Profibus slot/index 121/181
3 Fieldbus format Long
4 Modbus format Text

922 Software communication — PDF page 165

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 31038 software version 31039 option version
2 Profibus slot/index 121/182-183
3 Fieldbus format UInt
4 Modbus format UInt

Manual — Software version bits and unit naming — page 166

Manual reference: physical PDF page 166. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 28 Information for Modbus and Profibus number, software version Table 29 Information for Modbus and Profibus number, option version V 4.30 = Version of the Software NOTE: It is important that the software version displayed in menu [922] is the same software version number as the software version number written on the title page of this instruction manual. If not, the functionality as described in this manual may differ from the functionality of the AC drive.

Unit name [923] Option to enter a name of the unit for service use or customer identity. The function enables the user to define a name with 12 symbols. Use the Prev and Next key to move the cursor to the required position. Then use the + and - keys to scroll in the character list. Con- firm the character by moving the cursor to the next posi- tion by pressing the Next key. See section User-defined Unit [323]. Example Create user name USER 15. 1. When in the menu [923] press Next to move the cur- sor to the right most position. 2. Press the + key until the character U is displayed. 3. Press Next. 4. Then press the + key until S is displayed and con- firm with Next. 5. Repeat until you have entered USER15. Communication information When sending a unit name you send one character at a time starting at the right most position.

923 Unit Name Stp

Literal supplier cells; same-page conditions and cross-page continuations apply. Displayexamples not defaults. Merged physical extents retained. Not engineering approval.

923 Unit Name metadata — PDF page 166

Source row Property Source value
1 Default: No characters shown

923 communication — PDF page 166

Source row Communication property Source value
1 Modbus Instance no/DeviceNet no: 42301–42312
2 Profibus slot/index 165/225–236
3 Fieldbus format UInt
4 Modbus format UInt

Table28 software version bits — PDF page 166

Source row Bit Description
1 7–0 minor
2 13–8 major
3 15–14 release 00: V, release version 01: P, pre-release version 10: β, Beta version 11: α, Alpha version

Table29 option version bits — PDF page 166

Source row Bit Description
1 7–0 minor
2 15–8 major

Manual — Functional Description — page 167

Manual reference: physical PDF page 167. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Trips warnings limits and behavior table — page 168

Manual reference: physical PDF page 168. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

12.1 Trips, warnings and limits In order to protect the AC drive the principal operating variables are continuously monitored by the system. If one of these variables exceeds the safety limit an error/ warning message is displayed. In order to avoid any possibly dangerous situations, the inverter sets itself into a stop Mode called Trip and the cause of the trip is shown in the display. Trips will always stop the AC drive. Trips can be divided into normal and soft trips, depending on the setup Trip Type, see menu [250] Autoreset. Normal trips are default. For normal trips the AC drive stops immedi- ately, i.e. the motor coasts naturally to a standstill. For soft trips the AC drive stops by ramping down the speed, i.e. the motor decelerates to a standstill. “Normal Trip” • The AC drive stops immediately, the motor coasts to naturally to a standstill. • The Trip relay or output is active (if selected). • The Trip LED is on. • The accompanying trip message is displayed. • The “TRP” status indication is displayed (area D of the display). “Soft Trip” • the AC drive stops by decelerating to a standstill. During the deceleration. • The accompanying trip message is displayed, including an additional soft trip indicator “S” before the trip time. • The Trip LED is flashing. • The Warning relay or output is active (if selected). After standstill is reached. • The Trip LED is on. • The Trip relay or output is active (if selected). • The “TRP” status indication is displayed (area D of the display). Apart from the TRIP indicators there are two more indicators to show that the inverter is in an “abnormal” situation. “Warning” • The inverter is close to a trip limit. • The Warning relay or output is active (if selected). • The Trip LED is flashing. • The accompanying warning message is displayed in window [722] Warning. • One of the warning indications is displayed (area F of the display).

“Limits” • The inverter is limiting torque and/or frequency to avoid a trip. • The Limit relay or output is active (if selected). • The Trip LED is flashing. • One of the Limit status indications is displayed (area D of the display). Table 30 List of trips and warnings *) Refer to table Table 31regarding which Desat or Power Fault is triggered.

  1. Troubleshooting, Diagnoses and Maintenance

Motor I2t

Table30 Trips and warnings — PDF page 168

Source row Trip/Warning message Selections Trip Normal/Soft Warning indicator Area D
1 Motor I²t Trip/Off/Limit Normal/Soft I²t
2 PTC Trip/Off Normal/Soft ⟦blank source cell⟧
3 Motor PTC On Normal ⟦blank source cell⟧
4 PT100 Trip/Off Normal/Soft ⟦blank source cell⟧
5 Motor lost Trip/Off Normal ⟦blank source cell⟧
6 Locked rotor Trip/Off Normal ⟦blank source cell⟧
7 Ext trip Via DigIn Normal/Soft ⟦blank source cell⟧
8 Ext Mot Temp Via DigIn Normal/Soft ⟦blank source cell⟧
9 Mon MaxAlarm Trip/Off/Warn Normal/Soft ⟦blank source cell⟧
10 Mon MinAlarm Trip/Off/Warn Normal/Soft ⟦blank source cell⟧
11 Comm error Trip/Off/Warn Normal/Soft ⟦blank source cell⟧
12 Deviation Via Option Normal ⟦blank source cell⟧
13 Pump Via Option Normal ⟦blank source cell⟧
14 Over temp On Normal OT
15 Over curr F On Normal ⟦blank source cell⟧
16 Over volt D On Normal ⟦blank source cell⟧
17 Over volt G On Normal ⟦blank source cell⟧
18 Over volt On Normal ⟦blank source cell⟧
19 Over speed On Normal ⟦blank source cell⟧
20 Under voltage On Normal LV
21 LC Level Trip/Off/Warn Via DigIn Normal/Soft LCL
22 Desat ### * On Normal ⟦blank source cell⟧
23 DClink error On Normal ⟦blank source cell⟧
24 Power Fault PF #### * On Normal ⟦blank source cell⟧
25 Ovolt m cut On Normal ⟦blank source cell⟧
26 Over voltage Warning ⟦blank source cell⟧ VL
27 Safe stop Warning ⟦blank source cell⟧ SST
28 Brake Trip/Off/Warn Normal ⟦blank source cell⟧
29 OPTION On Normal ⟦blank source cell⟧

Manual — Fault diagnosis safety isolation and autoreset — page 169

Manual reference: physical PDF page 169. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

12.2 Trip conditions, causes and remedial action The table later on in this section must be seen as a basic aid to find the cause of a system failure and to how to solve any problems that arise. An AC drive is mostly just a small part of a complete AC drive system. Sometimes it is difficult to determine the cause of the failure, although the AC drive gives a certain trip message it is not always easy to find the right cause of the failure. Good knowl- edge of the complete drive system is therefore necessary. Contact your supplier if you have any ques- tions. The AC drive is designed in such a way that it tries to avoid trips by limiting torque, overvolt etc. Failures occurring during commissioning or shortly after commissioning are most likely to be caused by incorrect settings or even bad connections. Failures or problems occurring after a reasonable period of failure-free operation can be caused by changes in the system or in its environment (e.g. wear). Failures that occur regularly for no obvious reasons are generally caused by Electro Magnetic Interference. Be sure that the installation fulfils the demands for instal- lation stipulated in the EMC directives. See chapter 8. page 51. Sometimes the so-called “Trial and error” method is a quicker way to determine the cause of the failure. This can be done at any level, from changing settings and functions to disconnecting single control cables or replacing entire drives. The Trip Log can be useful for determining whether cer- tain trips occur at certain moments. The Trip Log also records the time of the trip in relation to the run time counter. WARNING! If it is necessary to open the AC drive or any part of the system (motor cable housing, conduits, electrical panels, cabinets, etc.) to inspect or take measure-ments as suggested in this instruction manual, it is absolutely necessary to read and follow the safety instructions in the manual.

12.2.1 Technically qualified personnel Installation, commissioning, demounting, making measurements, etc., of or at the AC drive may only be carried out by personnel technically qualified for the task. 12.2.2 Opening the AC drive WARNING! Always switch the mains voltage off if it is necessary to open the AC drive and wait at least 7 minutes to allow the capacitors to discharge. WARNING! In case of malfunctioning always check the DC-link voltage, or wait one hour after the mains voltage has been switched off, before dismantling the AC drive for repair. The connections for the control signals and the switches are isolated from the mains voltage. Always take adequate precautions before opening the AC drive. 12.2.3 Precautions to take with a connected motor If work must be carried out on a connected motor or on the driven machine, the mains voltage must always first be disconnected from the AC drive. Wait at least 7 min- utes before continuing. 12.2.4 Autoreset Trip If the maximum number of Trips during Autoreset has been reached, the trip message hour counter is marked with an “A”. Fig. 116 Autoreset trip Fig. 116 shows the 3rd trip memory menu [830]: Overvoltage G trip after the maximum Autoreset attempts took place after 345 hours, 45 minutes and 12 seconds of run time.

830 OVERVOLT G / Trp A 345:45:12; A marks exhausted autoreset attempts in this example.

Manual — Motor protection trip causes and remedies — page 170

Manual reference: physical PDF page 170. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 31 Trip condition, their possible causes and remedial action

Motor I2t “I2t”

Table31 Trip causes and remedies — PDF page 170

Source row Trip condition Possible cause Remedy Size **
1 Motor I²t “I²t” I²t value is exceeded. - Overload on the motor according to the programmed I²t settings. - Check on mechanical overload on the motor or the machinery (bearings, gearboxes, chains, belts, etc.) - Change the Motor I²t Current setting in menu group [230] ⟦blank source cell⟧
2 PTC Motor thermistor (PTC) exceeds maximum level. NOTE: Only valid if option board PTC/ PT100 is used. - Check on mechanical overload on the motor or the machinery (bearings, gearboxes, chains, belts, etc.) - Check the motor cooling system. - Self-cooled motor at low speed, too high load. - Set PTC, menu [234] to OFF ⟦blank source cell⟧
3 Motor PTC Motor thermistor (PTC) exceeds maximum level. NOTE: Only valid if [237] is enabled. - Check on mechanical overload on the motor or the machinery (bearings, gearboxes, chains, belts, etc.) - Check the motor cooling system. - Self-cooled motor at low speed, too high load. - Set PTC, menu [237] to OFF B,C,D
4 PT100 Motor PT100 elements exceeds maximum level. NOTE: Only valid if option board PTC/ PT100 is used. - Check on mechanical overload on the motor or the machinery (bearings, gearboxes, chains, belts, etc.) - Check the motor cooling system. - Self-cooled motor at low speed, too high load. - Set PT100 to OFF, menu [234] ⟦blank source cell⟧
5 Motor lost Phase loss or too great imbalance on the motor phases - Check the motor voltage on all phases. - Check for loose or poor motor cable connections - If all connections are OK, contact your supplier - Set motor lost alarm to OFF. ⟦blank source cell⟧
6 Locked rotor Torque limit at motor standstill: - Mechanical blocking of the rotor. - Check for mechanical problems at the motor or the machinery connected to the motor - Set locked rotor alarm to OFF. ⟦blank source cell⟧
7 Ext trip External input (DigIn 1-8) active: - active low function on the input. - Check the equipment that initiates the external input - Check the programming of the digital inputs DigIn 1-8 ⟦blank source cell⟧
8 Ext Mot Temp External input (DigIn 1-8) active: - active low function on the input. - Check the equipment that initiates the external input - Check the programming of the digital inputs DigIn 1-8 ⟦blank source cell⟧
9 Mon MaxAlarm Max alarm level (overload) has been reached. - Check the load condition of the machine - Check the monitor setting in section 11.6, page 140. ⟦blank source cell⟧
10 Mon MinAlarm Min alarm level (underload) has been reached. - Check the load condition of the machine - Check the monitor setting in section 11.6, page 140. ⟦blank source cell⟧

Manual — Communication option thermal and voltage trip remedies — page 171

Manual reference: physical PDF page 171. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 31 Trip condition, their possible causes and remedial action

Table31 Trip causes and remedies — PDF page 171

Source row Trip condition Possible cause Remedy Size **
1 Comm error Error on serial communication (option) - Check cables and connection of the serial communication. - Check all settings with regard to the serial communication - Restart the equipment including the AC drive ⟦blank source cell⟧
2 Deviation CRANE board detecting deviation in motor operation. NOTE: Only used in Crane Control. - Check encoder signals - Check Deviation jumper on Crane option board. - Check the settings in menu group [264] ⟦blank source cell⟧
3 Pump No master pump can be selected due to error in feedback signalling. NOTE: Only used in Pump Control. - Check cables and wiring for Pump feedback signals - Check settings with regard to the pump feedback digital inputs ⟦blank source cell⟧
4 Over temp Heatsink temperature too high: - Too high ambient temperature of the AC drive - Insufficient cooling - Too high current - Blocked or stuffed fans - Check the cooling of the AC drive cabinet. - Check the functionality of the built-in fans. The fans must switch on automatically if the heatsink temperature gets too high. At power up the fans are briefly switched on. - Check AC drive and motor rating - Clean fans ⟦blank source cell⟧
5 Over curr F Motor current exceeds the peak AC drive current: - Too short acceleration time. - Too high motor load - Excessive load change - Soft short-circuit between phases or phase to earth - Poor or loose motor cable connections - Too high IxR Compensation level - Check the acceleration time settings and make them longer if necessary. - Check the motor load. - Check on bad motor cable connections - Check on bad earth cable connection - Check on water or moisture in the motor housing and cable connections. - Lower the level of IxR Compensation [352] ⟦blank source cell⟧
6 Over volt D(eceleration) Too high DC Link voltage: - Too short deceleration time with respect to motor/machine inertia. - Too small brake resistor malfunctioning Brake chopper - Check the deceleration time settings and make them longer if necessary. - Check the dimensions of the brake resistor and the functionality of the Brake chopper (if used) ⟦blank source cell⟧
7 Over volt G(eneration) Too high DC Link voltage: - Too short deceleration time with respect to motor/machine inertia. - Too small brake resistor malfunctioning Brake chopper - Check the deceleration time settings and make them longer if necessary. - Check the dimensions of the brake resistor and the functionality of the Brake chopper (if used) ⟦blank source cell⟧
8 Over volt (Mains) Too high DC Link voltage, due to too high mains voltage - Check the main supply voltage - Try to take away the interference cause or use other main supply lines. ⟦blank source cell⟧
9 O(ver) volt M(ains) cut Too high DC Link voltage, due to too high mains voltage - Check the main supply voltage - Try to take away the interference cause or use other main supply lines. ⟦blank source cell⟧
10 Over speed Motor speed measurement exceeds maximum level. 110% of max speed (all parameter sets). Check encoder cables, wiring and setup Check motor data setup [22x] Perform short ID-run ⟦blank source cell⟧
11 Under voltage Too low DC Link voltage: - Too low or no supply voltage - Mains voltage dip due to starting other major power consuming machines on the same line. - Make sure all three phases are properly connected and that the terminal screws are tightened. - Check that the mains supply voltage is within the limits of the AC drive. - Try to use other mains supply lines if dip is caused by other machinery - Use the function low voltage override [421] ⟦blank source cell⟧
12 LC Level Low liquid cooling level in external reservoir. External input (DigIn 1-8) active: - active low function on the input. NOTE: Only valid for AC drive types with Liq- uid Cooling option. - Check liquid cooling - Check the equipment and wiring that initiates the external input - Check the programming of the digital inputs DigIn 1-8 ⟦blank source cell⟧
13 OPTION If an Option specific trip occurs Check the description of the specific option ⟦blank source cell⟧

Manual — Desaturation power faults brake remedies and size footnotes — page 172

Manual reference: physical PDF page 172. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 31 Trip condition, their possible causes and remedial action * = 2...6 Module number if parallel power units (size 300–1500 A) ** = If no size is mentioned in this column, the information is valid for all sizes.

Table31 Trip causes and remedies — PDF page 172

Source row Trip condition Possible cause Remedy Size **
1 Desat Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. B - D
2 Desat U+ * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
3 Desat U- * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
4 Desat V+ * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
5 Desat V- * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
6 Desat W+ * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
7 Desat W- * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
8 Desat BCC * Failure in output stage, - desaturation of IGBTs - Hard short circuit between phases or phase to earth - Earth fault - For size B - D also the Brake IGBT - Check on bad motor cable connections - Check on bad earth cable connections - Check on water and moisture in the motor housing and cable connections - Check that the rating plate data of the motor is correctly entered. - Check the brake resistor, brake IGBT and wiring. E & Up
9 DC link error DC link voltage ripple exceeds maximum level - Make sure all three phases are properly connected and that the terminal screws are tight- ened. - Check that the mains supply voltage is within the limits of the AC drive. - Try to use other mains supply lines if dip is caused by other machinery. ⟦blank source cell⟧
10 Power Fault One of the 10 PF (Power Fault) trips below has occured, but could not be determined. - Check the PF errors and try to determine the cause. The trip history can be helpful. ⟦blank source cell⟧
11 PF Fan Err * Error in fan module - Check for clogged air inlet filters in panel door and blocking material in fan module. E & Up
12 PF HCB Err* Error in controlled rectifier module (HCB) - Check mains supply voltage D & Up
13 PF Curr Err * Error in current balancing: - between different modules. - between two phases within one module. - Check motor. - Check fuses and line connections - Check the individual motor current leads with an clamp on amp meter. G& Up
14 PF Overvolt * Error in voltage balancing, overvoltage detected in one of the power modules (PEBB) - Check motor. - Check fuses and line connections. G& Up
15 PF Comm Err * Internal communication error Contact service ⟦blank source cell⟧
16 PF Int Temp * Internal temperature too high Check internal fans ⟦blank source cell⟧
17 PF Temp Err * Malfunction in temperature sensor Contact service ⟦blank source cell⟧
18 PF DC Err * DC-link error and mains supply fault - Check mains supply voltage - Check fuses and line connections. D & Up
19 PF Sup Err * Mains supply fault - Check mains supply voltage - Check fuses and line connections. ⟦blank source cell⟧
20 Brake Brake tripped on brake fault (not released) or Brake not engaged during stop. - Check Brake acknowledge signal wiring to selected digital input. - Check programming of digital input DigIn 1-8, [520]. - Check circuit breaker feeding mechanical brake circuit. - Check mechanical brake if acknowledge signal is wired from brake limit switch. - Check brake contactor. - Check settings [33C], [33D], [33E], [33F]. ⟦blank source cell⟧

Manual — Maintenance and regular inspection — page 173

Manual reference: physical PDF page 173. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

12.3 Maintenance The AC drive is designed not to require any servicing or maintenance. There are however some things which must be checked regularly. All AC drives have built-in fan which is speed controlled using heatsink temperature feedback. This means that the fans are only running if the AC drive is running and loaded. The design of the heatsinks is such that the fan does not blow the cooling air through the interior of the AC drive, but only across the outer surface of the heat- sink. However, running fans will always attract dust. Depending on the environment the fan and the heat- sink will collect dust. Check this and clean the heatsink and the fans when necessary. If AC drives are built into cabinets, also check and clean the dust filters of the cabinets regularly. Check external wiring, connections and control signals. Tighten terminal screws if necessary.

Manual — Control panel handheld panel and software options — page 174

Manual reference: physical PDF page 174. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Options The standard options available are described here briefly. Some of the options have their own instruction or installation manual. For more information please contact your supplier. 13.1 Options for the control panel Mounting cassette, blank panel and straight RS232- cable are available as options for the control panel. These options may be useful, for example for mounting a control panel in a cabinet door. Fig. 117 Control panel in mounting cassette

13.2 Handheld Control Panel 2.0 The Handheld Control Panel - HCP 2.0 is a complete control panel, easy to connect to the AC drive, for temporary use when e.g. commissioning, servicing and so on. The HCP has full functionality including memory. It is possible to set parameters, view signals, actual values, fault logger information and so on. It is also possible to use the memory to copy all data (such as parameter set data and motor data) from one AC drive to the HCP and then load this data to other AC drives 13.3 EmoSoftCom EmoSoftCom is an optional software that runs on a per- sonal computer. It can also be used to load parameter settings from the AC drive to the PC for backup and printing. Recording can be made in oscilloscope mode. Please contact your supplier for further information.

Illustrative control panel in mounting cassette. Visible RESET,PREV,NEXT,ESC,−,+,ENTER labels and symbols. Geometry and key symbols remain original-only.

Illustrative handheld control panel. Original image retained; no dimensions or connector pinout inferred from picture.

Handheld Control Panel2.0 — PDF page 174

Source row Part number Description
1 01-5039-00 Handheld Control Panel 2.0 complete for F33/V33 2.0 or CDU/CDX 2.0

Control panel options — PDF page 174

Source row Part number Description
1 01-3957-00 Panel kit complete including panel
2 01-3957-01 Panel kit complete including blank panel

Manual — Brake chopper formula voltage levels and JNVX48 resistors — page 175

Manual reference: physical PDF page 175. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

13.4 Brake chopper All AC drive sizes can be fitted with an optional built-in brake chopper. The brake resistor must be mounted outside the AC drive. The choice of the resistor depends on the application switch-on duration and duty-cycle. This option can not be after mounted. WARNING! The table gives the minimum values of the brake resistors. Do not use resistors lower than this value. The AC drive can trip or even be damaged due to high braking currents. The following formula can be used to define the power of the connected brake resistor: Where: Presistor required power of brake resistor Brake level VDCDC brake voltage level (see Table 32) Rmin minimum allowable brake resistor (see Table 33, Table 34 and Table 35 ED effective braking period. Defined as: tbr Active braking time at nominal braking power during a 2 minute operation cycle. Maximum value of ED = 1, meaning continuous braking. Table 32

Table 33 Brake resistor JNVX48 type

P_resistor = ((Brake level V_DC)^2 / R_min) × ED. Literal fraction and exponent transcribed from source; definitions and minimum-resistance warning remain mandatory context.

ED = t_br / (120 [s]). Source defines t_br as active braking time at nominal braking power during a 2 minute operation cycle; maximum ED=1 means continuous braking.

Table33 JNVX48 minimum brake resistance — PDF page 175

Source row Type Rmin ohm at380–415VAC Rmin ohm at440–480VAC
1 JNVX48- 0003 43 50
2 -0004 43 50
3 -0006 43 50
4 -0008 43 50
5 -0010 43 50
6 -0013 43 50
7 -0018 43 50
8 -0026 26 30
9 -0031 26 30
10 -0037 17 20
11 -046 17 20
12 -0061 10 12
13 -0074 10 12
14 -0090 3.8 4.4
15 -0109 3.8 4.4
16 -0146 3.8 4.4
17 -0175 3.8 4.4
18 -0210 2.7 3.1
19 -0250 2.7 3.1
20 -0300 2 x 3.8 2 x 4.4
21 -0375 2 x 3.8 2 x 4.4
22 -0430 2 x 2.7 2 x 3.1
23 -0500 2 x 2.7 2 x 3.1
24 -0600 3 x 2.7 3 x 3.1
25 -0650 3 x 2.7 3 x 3.1
26 -0750 3 x 2.7 3 x 3.1
27 -0860 4 x 2.7 4 x 3.1
28 -1000 4 x 2.7 4 x 3.1
29 -1200 6 x 2.7 6 x 3.1
30 -1500 6 x 2.7 6 x 3.1

Table32 Brake voltage level — PDF page 175

Source row Supply VAC set in21B Brake level VDC
1 220–240 380
2 380–415 660
3 440–480 780
4 500–525 860
5 550–600 1000
6 660–690 1150

Manual — JNVX52 JNVX69 resistors and option board variants — page 176

Manual reference: physical PDF page 176. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 34 Brake resistors JNVX52 V types Table 35 Brake resistors JNVX69 V types NOTE: Although the AC drive will detect a failure in the brake electronics, the use of resistors with a thermal overload which will cut off the power at overload is strongly recommended.

The brake chopper option is built-in by the manufac- turer and must be specified when the AC drive is ordered. 13.5 I/O Board Each I/O option board 2.0 provides three extra relay outputs and three extra digital inputs (24V). The I/O Board works in combination with the Pump/Fan Con- trol, but can also be used as a separate option. Maxi- mum 3 I/O boards possible. This option is described in a separate manual. 13.6 Encoder The Encoder 2.0 option board, used for connection of feedback signal of the actual motor speed via an incre- mental encoder is described in a separate manual. 13.7 PTC/PT100 The PTC/PT100 2.0 option board for connecting motor thermistors and max 3 PT100 elements to the AC drive is described in a separate manual. 13.8 Crane option board This option is used in crane applications. The crane option board 2.0 is described in a separate manual.

Table34 JNVX52 minimum brake resistance — PDF page 176

Source row Type Rmin ohm at440–480VAC Rmin ohm at500–525VAC
1 JNVX52- 0003 50 55
2 -0004 50 55
3 -0006 50 55
4 -0008 50 55
5 -0010 50 55
6 -0013 50 55
7 -0018 50 55
8 -0026 30 32
9 -0031 30 32
10 -0037 20 22
11 -0046 20 22
12 -0061 12 14
13 -0074 12 14

Table35 JNVX69 minimum brake resistance — PDF page 176

Source row Type Rmin ohm at500–525VAC Rmin ohm at550–600VAC Rmin ohm at660–690VAC
1 JNVX69- 0090 4.9 5.7 6.5
2 -0109 4.9 5.7 6.5
3 -0146 4.9 5.7 6.5
4 -0175 4.9 5.7 6.5
5 -0210 2 x 4.9 2 x 5.7 2 x 6.5
6 -0250 2 x 4.9 2 x 5.7 2 x 6.5
7 -0300 2 x 4.9 2 x 5.7 2 x 6.5
8 -0375 2 x 4.9 2 x 5.7 2 x 6.5
9 -0430 3 x 4.9 3 x 5.7 3 x 6.5
10 -0500 3 x 4.9 3 x 5.7 3 x 6.5
11 -0600 4 x 4.9 4 x 5.7 4 x 6.5
12 -0650 4 x 4.9 4 x 5.7 4 x 6.5
13 -0750 6 x 4.9 6 x 5.7 6 x 6.5
14 -0860 6 x 4.9 6 x 5.7 6 x 6.5
15 -0900 6 x 4.9 6 x 5.7 6 x 6.5
16 -1000 6 x 4.9 6 x 5.7 6 x 6.5

I/O Board — PDF page 176

Source row Part number Description
1 01-3876-01 I/O option board 2.0

Encoder — PDF page 176

Source row Part number Description
1 01-3876-03 Encoder 2.0 option board

PTC/PT100 — PDF page 176

Source row Part number Description
1 01-3876-08 PTC/PT100 2.0 option board

Crane option board — PDF page 176

Source row Part number Description
1 590059 Crane interface board, 230 VAC
2 590060 Crane interface board, 24 VDC

Manual — Communication and standby supply option terminal specifications — page 177

Manual reference: physical PDF page 177. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

13.9 Serial communication and fieldbus For communication with the AC drive there are several option boards for communication. There are different options for Fieldbus communication and one serial communication option with RS232 or RS485 interface which has galvanic isolation. 13.10 Standby supply board option The standby supply board option provides the possibil- ity of keeping the communication system up and run- ning without having the 3-phase mains connected. One advantage is that the system can be set up without mains power. The option will also give backup for com- munication failure if main power is lost. The standby supply board option is supplied with exter- nal ±10% 24 VDC protected by a 2 A slow acting fuse, from a double isolated transformer. The terminals X1:1, X1:2 (on size B,C and E to F) are voltage polarity inde- pendant. The terminals A and B (on size D) are voltage polarity dependent.

Fig. 118 Connection of standby supply option on size B,C and E-F Fig. 119 Connection of standby supply option on size D

X1; X1:1 Left terminal; X1:2 Right terminal; Must be double isolated; AC symbol. Original connection geometry authoritative.

Connect the power supply board to the two blue terminals marked A− and B+;0V to A−;24V to B+;DC symbol. Original terminal geometry authoritative.

Manually bounded source table with merged function/specification cells. Source wording retained even when inconsistent with adjacent text. Original connection diagram authoritative.

Serial and fieldbus options — PDF page 177

Source row Part number Description
1 01-3876-04 RS232/485
2 01-3876-05 Profibus DP
3 01-3876-06 DeviceNet
4 01-3876-09 Modbus/TCP, Ethernet

Standby supply option — PDF page 177

Source row Part number Description
1 01-3954-00 Standby power supply kit for after mounting

Standby supply X1 terminals sizeB,C,E–F — PDF page 177

Source row Terminal Name Function Specification
1 1 Ext. supply 1 External, AC drive main power inde- pendent, supply voltage for control and communica- tion circuits 24 VDC ±10% Double iso- lated
2 2 Ext. supply 2 External, AC drive main power inde- pendent, supply voltage for control and communica- tion circuits 24 VDC ±10% Double iso- lated

Standby supply terminals sizeD — PDF page 177

Source row Terminal Name Function Specification
1 A - 0V External, AC drive main power depend- ent, supply voltage for control and communi- cation circuits 24 VDC ±10% Double isolated
2 B + +24V External, AC drive main power depend- ent, supply voltage for control and communi- cation circuits 24 VDC ±10% Double isolated

Manual — Safe Stop conditions warnings and restart procedure — page 178

Manual reference: physical PDF page 178. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

13.11 Safe Stop option To realize a Safe Stop configuration in accordance with Safe Torque Off (STO) EN-IEC 62061:2005 SIL 2 & EN- ISO 13849-1:2006, the following three parts need to be attended to: 1. Inhibit trigger signals with safety relay K1 (via Safe Stop option board). 2. Enable input and control of AC drive (via normal I/O control signals of AC drive). 3. Power conductor stage (checking status and feed- back of driver circuits and IGBT’s). To enable the AC drive to operate and run the motor, the following signals should be active: • "Inhibit" input, terminals 1 (DC+) and 2 (DC-) on the Safe Stop option board should be made active by connecting 24 VDC to secure the supply voltage for the driver circuits of the power conductors via safety relay K1. See also Fig. 122. • High signal on the digital input, e.g. terminal 10 in Fig. 122, which is set to "Enable". For setting the dig- ital input please refer to section 11.5.2, page 130. These two signals need to be combined and used to enable the output of the AC drive and make it possible to activate a Safe Stop condition. NOTE: The "Safe Stop" condition according to EN-IEC 62061:2005 SIL 2 & EN-ISO 13849-1:2006, can only be realized by de-activating both the "Inhibit" and "Enable" inputs. When the "Safe Stop" condition is achieved by using these two different methods, which are independently controlled, this safety circuit ensures that the motor will not start running because: • The 24VDC signal is disconnected from the "Inhibit" input, terminals 1 and 2, the safety relay K1 is switched off. The supply voltage to the driver circuits of the power conductors is switched off. This will inhibit the trig- ger pulses to the power conductors. • The trigger pulses from the control board are shut down. The Enable signal is monitored by the controller cir- cuit which will forward the information to the PWM part on the Control board. To make sure that the safety relay K1 has been switched off, this should be guarded externally to ensure that this relay did not refuse to act. The Safe Stop option board offers a feedback signal for this via a second forced switched safety relay K2 which is switched on when a detection circuit has confirmed that the supply voltage to the driver circuits is shut down. See Table 36 for the con- tacts connections.

To monitor the "Enable" function, the selection "RUN" on a digital output can be used. For setting a digital out- put, e.g. terminal 20 in the example Fig. 122, please refer to section 11.5.4, page 136 [540]. When the "Inhibit" input is de-activated, the AC drive display will show a flashing "SST" indication in section D (bottom left corner) and the red Trip LED on the Control panel will be flashing. To resume normal operation, the following steps have to be taken: • Release "Inhibit" input; 24VDC (High) to terminal 1 and 2. • Give a STOP signal to the AC drive, according to the set Run/Stop Control in menu [215]. • Give a new Run command, according to the set Run/ Stop Control in menu [215]. NOTE: The method of generating a STOP command is dependent on the selections made in Start Signal Level/ Edge [21A] and the use of a separate Stop input via digital input. WARNING! The safe stop function can never be used for electrical maintenance. For electrical maintenance the AC drive should always be disconnected from the supply voltage. Fig. 120 Connection of safe stop option in size B - D.

Safe Stop board illustration for sizeB–D. Visible2,C andterminal numbers1–6; original board and wiring geometry authoritative. No inferred wiring instructions.

Manual — Safe Stop pin specifications and original circuit diagram — page 179

Manual reference: physical PDF page 179. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Fig. 121 Connection of safe stop option in size E and up. Fig. 122

Table 36 Specification of Safe Stop option board

Safe Stop board illustration for sizeE andup; visible terminal numbers1–6. Original assembly geometry authoritative.

Safe Stop;X1 terminals1,2,3,4,5,6;NC;K1;K2;+5V;+24VDC;Power board;U,V,W;Enable;X1 terminal10 DigIn;Stop;X1 terminal20 DigOut;Controller;PWM;DC/AC andground symbols. Labels transcribed; all circuit connections remain original-only, not reconstructed wiring.

Table36 Safe Stop option specifications — PDF page 179

Source row X1 pin Name Function Specification
1 1 Inhibit + Inhibit driver circuits of power conductors DC 24 V (20–30 V)
2 2 Inhibit - Inhibit driver circuits of power conductors DC 24 V (20–30 V)
3 3 NO contact relay K2 Feedback; confirmation of activated inhibit 48 VDC/ 30 VAC/2 A
4 4 P contact relay K2 Feedback; confirmation of activated inhibit 48 VDC/ 30 VAC/2 A
5 5 GND Supply ground ⟦blank source cell⟧
6 6 +24 VDC Supply Voltage for oper- ating Inhibit input only. +24 VDC, 50 mA

Manual — Output chokes and liquid cooling option scope — page 180

Manual reference: physical PDF page 180. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

13.12 Output chokes Output chokes, which are supplied separately, are rec- ommended for lengths of screened motor cable longer than 100 m. Because of the fast switching of the motor voltage and the capacitance of the motor cable (both line to line and line to earth screen), large switching currents can be generated with long lengths of motor cable. Output chokes prevent the AC drive from tripping and should be installed as closely as possible to the AC drive. 13.13 Liquid cooling AC drive modules in frame sizes E - K and F69 - K69 are available in a liquid cooled version. These units are designed for connection to a liquid cooling system, nor- mally a heat exchanger of liquid-liquid or liquid-air type. Heat exchanger is not part of the liquid cooling option. Drive units with parallel power modules (frame size G - K69) are delivered with a dividing unit for connec- tion of the cooling liquid. The drive units are equipped with rubber hoses with leak-proof quick couplings. The Liquid cooling option is described in a separate manual

Manual — Options — page 181

Manual reference: physical PDF page 181. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — 400V model electrical ratings and duty conditions — page 182

Manual reference: physical PDF page 182. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Technical Data 14.1 Electrical specifications related to model Table 37 Typical motor power at mains voltage 400 V * Available during limited time and as long as allowed by drive temperature.

Table37 typical motor power at400V — PDF page 182

Source row Model Max output current[A]* Normal duty120%1min/10min Power@400V[kW] Normal duty rated current[A] Heavy duty150%1min/10min Power@400V[kW] Heavy duty rated current[A] Frame size
1 JNVX48-0003 3.8 0.75 2.5 0.55 2.0 B
2 JNVX48-0004 6.0 1.5 4.0 1.1 3.2 B
3 JNVX48-0006 9.0 2.2 6.0 1.5 4.8 B
4 JNVX48-0008 11.3 3 7.5 2.2 6.0 B
5 JNVX48-0010 14.3 4 9.5 3 7.6 B
6 JNVX48-0013 19.5 5.5 13.0 4 10.4 B
7 JNVX48-0018 27.0 7.5 18.0 5.5 14.4 B
8 JNVX48-0026 39 11 26 7.5 21 C
9 JNVX48-0031 46 15 31 11 25 C
10 JNVX48-0037 55 18.5 37 15 29.6 C
11 JNVX48-0046 69 22 46 18.5 37 C
12 JNVX48-0061 92 30 61 22 49 D
13 JNVX48-0074 111 37 74 30 59 D
14 JNVX48-0090 108 45 90 37 72 E
15 JNVX48-0109 131 55 109 45 87 E
16 JNVX48-0146 175 75 146 55 117 E
17 JNVX48-0175 210 90 175 75 140 E
18 JNVX48-0210 252 110 210 90 168 F
19 JNVX48-0228 300 110 228 90 182 F
20 JNVX48-0250 300 132 250 110 200 F
21 JNVX48-0300 360 160 300 132 240 G
22 JNVX48-0375 450 200 375 160 300 G
23 JNVX48-0430 516 220 430 200 344 H
24 JNVX48-0500 600 250 500 220 400 H
25 JNVX48-0600 720 315 600 250 480 I
26 JNVX48-0650 780 355 650 315 520 I
27 JNVX48-0750 900 400 750 355 600 I
28 JNVX48-0860 1032 450 860 400 688 J
29 JNVX48-1000 1200 500 1000 450 800 J
30 JNVX48-1200 1440 630 1200 500 960 K
31 JNVX48-1500 1800 800 1500 630 1200 K

Manual — 460V model electrical ratings and duty conditions — page 183

Manual reference: physical PDF page 183. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 38 Typical motor power at mains voltage 460 V * Available during limited time and as long as allowed by drive temperature.

Table38 typical motor power at460V — PDF page 183

Source row Model Max output current[A]* Normal duty120%1min/10min Power@460V[hp] Normal duty rated current[A] Heavy duty150%1min/10min Power@460V[hp] Heavy duty rated current[A] Frame size
1 JNVX48-0003 3.8 1 2.5 1 2.0 B
2 JNVX48-0004 6.0 2 4.0 1.5 3.2 B
3 JNVX48-0006 9.0 3 6.0 2 4.8 B
4 JNVX48-0008 11.3 3 7.5 3 6.0 B
5 JNVX48-0010 14.3 5 9.5 3 7.6 B
6 JNVX48-0013 19.5 7.5 13.0 5 10.4 B
7 JNVX48-0018 27.0 10 18.0 7.5 14.4 B
8 JNVX48-0026 39 15 26 10 21 C
9 JNVX48-0031 46 20 31 15 25 C
10 JNVX48-0037 55 25 37 20 29.6 C
11 JNVX48-0046 69 30 46 25 37 C
12 JNVX48-0061 92 40 61 30 49 D
13 JNVX48-0074 111 50 74 40 59 D
14 JNVX48-0090 108 60 90 50 72 E
15 JNVX48-0109 131 75 109 60 87 E
16 JNVX48-0146 175 100 146 75 117 E
17 JNVX48-0175 210 125 175 100 140 E
18 JNVX48-0210 252 150 210 125 168 F
19 JNVX48-0228 300 200 228 150 182 F
20 JNVX48-0250 300 200 250 150 200 F
21 JNVX48-0300 360 250 300 200 240 G
22 JNVX48-0375 450 300 375 250 300 G
23 JNVX48-0430 516 350 430 250 344 H
24 JNVX48-0500 600 400 500 350 400 H
25 JNVX48-0600 720 500 600 400 480 I
26 JNVX48-0650 780 550 650 400 520 I
27 JNVX48-0750 900 600 750 500 600 I
28 JNVX48-0860 1032 700 860 550 688 J
29 JNVX48-1000 1200 800 1000 650 800 J
30 JNVX48-1200 1440 1000 1200 800 960 K
31 JNVX48-1500 1800 1250 1500 1000 1200 K

Manual — 525V model electrical ratings and source model typo — page 184

Manual reference: physical PDF page 184. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 39 Typical motor power at mains voltage 525 V * Available during limited time and as long as allowed by drive temperature.

Table39 typical motor power at525V — PDF page 184

Source row Model Max output current[A]* Normal duty120%1min/10min Power@525V[kW] Normal duty rated current[A] Heavy duty150%1min/10min Power@525V[kW] Heavy duty rated current[A] Frame size
1 JNVX52-0003 3.8 1.1 2.5 1.1 2.0 B
2 JNVX52-0004 6.0 2.2 4.0 1.5 3.2 B
3 JNVX52-0006 9.0 3 6.0 2.2 4.8 B
4 JNVX52-0008 11.3 4 7.5 3 6.0 B
5 JNVX52-0010 14.3 5.5 9.5 4 7.6 B
6 JNVX52-0013 19.5 7.5 13.0 5.5 10.4 B
7 JNVX52-0018 27.0 11 18.0 7.5 14.4 B
8 JNVX52-0026 39 15 26 11 21 C
9 JNVX52-0031 46 18.5 31 15 25 C
10 JNVX52-0037 55 22 37 18.5 29.6 C
11 JNVX52-0046 69 30 46 22 37 C
12 JNVX52-0061 92 37 61 30 49 D
13 JNVX52-0074 111 45 74 37 59 D
14 JNVX69-0090 108 55 90 45 72 F69
15 JNVX69-0109 131 75 109 55 87 F69
16 JNVX69-0146 175 90 146 75 117 F69
17 JNVX69-0175 210 110 175 90 140 F69
18 JNVX69-0210 252 132 210 110 168 H69
19 JNVX69-0250 300 160 250 132 200 H69
20 JNVX69-0300 360 200 300 160 240 H69
21 JNVX69-0375 450 250 375 200 300 H69
22 JNVX69-0430 516 300 430 250 344 I69
23 JNVX69-0500 600 315 500 300 400 I69
24 JNVX69-0600 720 400 600 315 480 J69
25 JNVX690-650 780 450 650 355 520 J69
26 JNVX69-0750 900 500 750 400 600 K69
27 JNVX69-0860 1032 560 860 450 688 K69
28 JNVX69-1000 1200 630 1000 500 800 K69

Manual — 575V and690V model electrical ratings — page 185

Manual reference: physical PDF page 185. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 40 Typical motor power at mains voltage 575 V * Available during limited time and as long as allowed by drive temperature. Table 41 Typical motor power at mains voltage 690 V * Available during limited time and as long as allowed by drive temperature.

Table40 typical motor power at575V — PDF page 185

Source row Model Max output current[A]* Normal duty120%1min/10min Power@575V[hp] Normal duty rated current[A] Heavy duty150%1min/10min Power@575V[hp] Heavy duty rated current[A] Frame size
1 JNVX69-0090 108 75 90 60 72 F69
2 JNVX69-0109 131 100 109 75 87 F69
3 JNVX69-0146 175 125 146 100 117 F69
4 JNVX69-0175 210 150 175 125 140 F69
5 JNVX69-0210 252 200 210 150 168 H69
6 JNVX69-0250 300 250 250 200 200 H69
7 JNVX69-0300 360 300 300 250 240 H69
8 JNVX69-0375 450 350 375 300 300 H69
9 JNVX69-0430 516 400 430 350 344 I69
10 JNVX69-0500 600 500 500 400 400 I69
11 JNVX69-0600 720 600 600 500 480 J69
12 JNVX69-0650 780 650 650 550 520 J69
13 JNVX69-0750 900 750 750 600 600 K69
14 JNVX69-0860 1032 850 860 700 688 K69
15 JNVX69-1000 1200 1000 1000 850 800 K69

Table41 typical motor power at690V — PDF page 185

Source row Model Max output current[A]* Normal duty120%1min/10min Power@690V[kW] Normal duty rated current[A] Heavy duty150%1min/10min Power@690V[kW] Heavy duty rated current[A] Frame size
1 JNVX69-0090 108 90 90 75 72 F69
2 JNVX69-0109 131 110 109 90 87 F69
3 JNVX69-0146 175 132 146 110 117 F69
4 JNVX69-0175 210 160 175 132 140 F69
5 JNVX69-0210 252 200 210 160 168 H69
6 JNVX69-0250 300 250 250 200 200 H69
7 JNVX69-0300 360 315 300 250 240 H69
8 JNVX69-0375 450 355 375 315 300 H69
9 JNVX69-0430 516 450 430 315 344 I69
10 JNVX69-0500 600 500 500 355 400 I69
11 JNVX69-0600 720 600 600 450 480 J69
12 JNVX69-0650 780 630 650 500 520 J69
13 JNVX69-0750 900 710 750 600 600 K69
14 JNVX69-0860 1032 800 860 650 688 K69
15 JNVX69-0900 1080 900 900 710 720 K69
16 JNVX69-1000 1200 1000 1000 800 800 K69

Manual — General electrical specifications and signal limits — page 186

Manual reference: physical PDF page 186. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.2 General electrical specifications Table 42 General electrical specifications General Control signal inputs: Analogue (differential) Digital: Control signal outputs Analogue Digital Relays References

Manually bounded unruled rows. All electrical conditions and units literal. JNVX52/JNVX69 rows continue mains-voltage property; efficiency retains both model ranges. Hardware accuracy is supplier wording, not independent engineering verification.

Table42 General — PDF page 186

Source row Property Source specification
1 Mains voltage: JNVX48 230-480V +10%/-15% (-10% at 230 V)
2 JNVX52 440-525 V +10 %/-15 %
3 JNVX69 500-690V +10%/-15%
4 Mains frequency: 45 to 65 Hz
5 Input power factor: 0.95
6 Output voltage: 0–Mains supply voltage:
7 Output frequency: 0–400 Hz
8 Output switching frequency: 3 kHz
9 Efficiency at nominal load: 97% for models 0003 to 0018 98% for models 0026 to 1500

Table42 Analogue differential inputs — PDF page 186

Source row Property Source specification
1 Analogue Voltage/current: 0-±10 V/0-20 mA via switch
2 Max. input voltage: +30 V/30 mA
3 Input impedance: 20 kΩ (voltage) 250 Ω (current)
4 Resolution: 11 bits + sign
5 Hardware accuracy: 1% type + 1 ½ LSB fsd
6 Non-linearity 1½ LSB

Table42 Digital inputs — PDF page 186

Source row Property Source specification
1 Input voltage: High: >9 VDC, Low: <4 VDC
2 Max. input voltage: +30 VDC
3 Input impedance: <3.3 VDC: 4.7 kΩ ≥3.3 VDC: 3.6 kΩ
4 Signal delay: ≤8 ms

Table42 Analogue outputs — PDF page 186

Source row Property Source specification
1 Output voltage/current: 0-10 V/0-20 mA via software setting
2 Max. output voltage: +15 V @5 mA cont.
3 Short-circuit current (∞): +15 mA (voltage), +140 mA (current)
4 Output impedance: 10 Ω (voltage)
5 Resolution: 10 bit
6 Maximum load impedance for current 500 Ω
7 Hardware accuracy: 1.9% type fsd (voltage), 2.4% type fsd (current)
8 Offset: 3 LSB
9 Non-linearity: 2 LSB

Table42 Digital outputs — PDF page 186

Source row Property Source specification
1 Output voltage: High: >20 VDC @50 mA, >23 VDC open Low: <1 VDC @50 mA
2 Shortcircuit current(∞): 100 mA max (together with +24 VDC)

Table42 Relay contacts — PDF page 186

Source row Property Source specification
1 Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC

Table42 Reference supplies — PDF page 186

Source row Property Source specification
1 +10VDC +10 VDC @10 mA Short-circuit current +30 mA max
2 -10VDC -10 VDC @10 mA
3 +24VDC +24 VDC Short-circuit current +100 mA max (together with Digital Outputs)

Manual — Temperature derating and contradictory sizing example — page 187

Manual reference: physical PDF page 187. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.3 Operation at higher temperatures Most AC drives are made for operation at maximum of 40°C ambient temperature. However, for most models, it is possible to use the AC drive at higher temperatures with little loss in performance. Table 43 shows ambient temperatures as well as derating for higher tempera- tures. Table 43 Ambient temperature and derating 400–690 V types Example In this example we have a motor with the following data that we want to run at the ambient temperature of 45°C: Voltage 400 V Current 68 A Power 37 kW Select AC drive The ambient temperature is 5 °C higher than the maxi- mum ambient temperature. The following calculation is made to select the correct AC drive model. Derating is possible with loss in performance of 2.5%/ °C. Derating will be: 5 X 2.5% = 12.5% Calculation for model JNVX48-0031 31 A - (12.5% x 31) = 27.1 A; this is not enough. Calculation for model JNVX48-0037 37 A - (12.5% x 37) = 32.4 A In this example we select the JNVX48-0037.

Table43 ambient temperature derating — PDF page 187

Source row Model range IP20 maximum temperature IP20 derating IP54 maximum temperature IP54 derating
1 JNVX**-0003 to JNVX**-0074 – – 40°C -2.5%/°C to max +10°C
2 JNVX48-0090 to JNVX48-0250 JNVX69-0090 to JNVX69-0175 – – 40°C -2.5%/°C to max +5°C
3 JNVX48-0300 to JNVX48-1500 JNVX69-0210 to JNVX69-1000 40°C -2.5%/°C to max +5°C 40°C -2.5%/°C to max +5°C

Manual — Model IP20 IP54 dimensions and weights — page 188

Manual reference: physical PDF page 188. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.4 Dimensions and Weights The table below gives an overview of the dimensions and weights. The models 003 to 250 is available in IP54 as wall mounted modules. The models 300 to 1500 consist of 2, 3, 4 or 6 paralleled power electonic building block (PEBB) available in IP20 as wall mounted modules and in IP54 mounted standard cabinet Protection class IP54 is according to the EN 60529 standard. Table 44 Mechanical specifications, JNVX48, JNVX52 Table 45 Mechanical specifications, JNVX69

Table44 mechanical JNVX48/JNVX52 — PDF page 188

Source row Models Frame size IP20 HxWxD mm IP54 HxWxD mm IP20 kg IP54 kg
1 0003 to 0018 B – 350(416)x 203 x 200 – 12.5
2 0026 to 0046 C – 440(512) x 178 x 292 – 24
3 0061 to 0074 D – 545(590) x 220 x 295 – 32
4 0090 to 0109 E – 950 x 285 x 314 – 56
5 0146 to 0175 E – 950 x 285 x 314 – 60
6 0210 to 0250 F – 950 x 345 x 314 – 74
7 0300 to 0375 G 1036 x 500 x 390 2330 x 600 x 500 140 270
8 0430 to 0500 H 1036 x 500 x 450 2330 x 600 x 600 170 305
9 0600 to 0750 I 1036 x 730 x 450 2330 x 1000 x 600 248 440
10 0860 to 1000 J 1036 x 1100 x 450 2330 x 1200 x 600 340 580
11 1200 to 1500 K 1036 x 1560 x 450 2330 x 2000 x 600 496 860

Table45 mechanical JNVX69 — PDF page 188

Source row Models Frame size IP20 HxWxD mm IP54 HxWxD mm IP20 kg IP54 kg
1 0090 to 0175 F69 – 1090 x 345 x 314 – 77
2 0210 to 0375 H69 1176 x 500 x 450 2330 x 600 x 600 176 311
3 0430 to 0500 I69 1176 x 730 x 450 2330 x 1000 x 600 257 449
4 0600 to 0650 J69 1176 x 1100 x 450 2330 x 1200 x 600 352 592
5 0750 to 1000 K69 1176 x 1560 x 450 2330 x 2000 x 600 514 878

Manual — Operation and storage environment limits — page 189

Manual reference: physical PDF page 189. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.5 Environmental conditions Table 46 Operation Table 47 Storage

Table46 normal operation environment — PDF page 189

Source row Parameter Normal operation
1 Nominal ambient temperature 0°C–40°C See table, see Table 43 for different conditions
2 Atmospheric pressure 86–106 kPa
3 Relative humidity, non-condensing 0–90%
4 Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corro- sive materials. Chemical gases, class 3C2. Solid particles, class 3S2.
5 Vibrations According to IEC 600068-2-6, Sinusodial vibrations: 10<f<57 Hz, 0.075 mm 57<f<150 Hz, 1g
6 Altitude 0–1000 m 480V AC drives, with derating 1%/100 m of rated current up to 4000 m 690V AC drives, with derating 1%/100 m of rated current up to 2000 m

Table47 storage environment — PDF page 189

Source row Parameter Storage condition
1 Temperature -20 to +60 °C
2 Atmospheric pressure 86–106 kPa
3 Relative humidity, non-condensing 0– 90%

Manual — IEC fuses cable ranges and glands — page 190

Manual reference: physical PDF page 190. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.6 Fuses, cable cross- sections and glands 14.6.1 According IEC ratings Use mains fuses of the type gL/gG conforming to IEC 269 or installation cut-outs with similar characteristics. Check the equipment first before installing the glands. Max. Fuse = maximum fuse value that still protects the AC drive and upholds warranty. Table 48 Fuses, cable cross-sections and glands

NOTE: The dimensions of fuse and cable cross-section are dependent on the application and must be determined in accordance with local regulations. NOTE: The dimensions of the power terminals used in the models 300 to 1500 can differ depending on customer specification.

Table48 fuses cables and glands — PDF page 190

Source row Model Nominal input current A Maximum fuse A Mains/motor connector mm² Brake connector mm² PE connector mm² Mains/motor gland mm Brake gland mm
1 JNVX**- 0003 JNVX**- 0004 JNVX**- 0006 2.2 3.5 5.2 4 4 6 0.5–10 0.5–10 1.5–16 M32 opening M20 + reducer (6–12) M25 opening M20 + reducer (6–12)
2 JNVX**- 0008 JNVX**-0010 6.9 8.7 8 10 0.5–10 0.5–10 1.5–16 M32 (12–20)/ M32 opening M25+reducer (10-14) M25 (10–14)
3 JNVX**-0013 JNVX**-0018 11.3 15.6 16 20 0.5–10 0.5–10 1.5–16 M32 (16–25)/ M32 (13–18) M25 (10–14)
4 JNVX**- 0026 22 25 2.5 - 16 stranded wire 2.5 - 25 solid wire 2.5 - 16 stranded wire 2.5 - 25 solid wire 6 - 35 M32 (15–21) M25
5 JNVX**-0031 26 35 2.5 - 16 stranded wire 2.5 - 25 solid wire 2.5 - 16 stranded wire 2.5 - 25 solid wire 6 - 35 M32 (15–21) M25
6 JNVX**-0037 31 35 2.5 - 16 stranded wire 2.5 - 25 solid wire 2.5 - 16 stranded wire 2.5 - 25 solid wire 6 - 35 M40 (19–28) M32
7 JNVX**- 0046 38 50 2.5 - 16 stranded wire 2.5 - 25 solid wire 2.5 - 16 stranded wire 2.5 - 25 solid wire 6 - 35 M40 (19–28) M32
8 JNVX**-0061 52 63 1 - 35 stranded wire 1 - 50 solid wire 1 - 35 stranded wire 1 - 50 solid wire 1 - 35 stranded wire 1 - 50 solid wire M50 (27 - 35) M40 (19 - 28)
9 JNVX**-0074 65 80 1 - 35 stranded wire 1 - 50 solid wire 1 - 35 stranded wire 1 - 50 solid wire 1 - 35 stranded wire 1 - 50 solid wire M50 (27 - 35) M40 (19 - 28)
10 JNVX**- 0090 78 100 16 - 95 16 - 95 16-95 (16-70)¹ JNVX48: Ø17- 42 cable flexi- ble leadthrough or M50 opening. JNVX69: Ø23- 55 Cable flexi- ble leadthrough or M63 opening. FX48: Ø11-32 Cable flexible leadthrough or M40 opening. JNVX69: Ø17- 42 Cable flexi- ble leadthrough or M50 opening.
11 JNVX**-0109 94 100 16 - 95 16 - 95 16-95 (16-70)¹ JNVX48: Ø17- 42 cable flexi- ble leadthrough or M50 opening. JNVX69: Ø23- 55 Cable flexi- ble leadthrough or M63 opening. FX48: Ø11-32 Cable flexible leadthrough or M40 opening. JNVX69: Ø17- 42 Cable flexi- ble leadthrough or M50 opening.
12 JNVX**-0146 126 160 35 - 150 16 - 95 35-150 (16-70)¹ JNVX48: Ø17- 42 cable flexi- ble leadthrough or M50 opening. JNVX69: Ø23- 55 Cable flexi- ble leadthrough or M63 opening. FX48: Ø11-32 Cable flexible leadthrough or M40 opening. JNVX69: Ø17- 42 Cable flexi- ble leadthrough or M50 opening.
13 JNVX**-0175 152 160 35 - 150 16 - 95 35-150 (16-70)¹ JNVX48: Ø17- 42 cable flexi- ble leadthrough or M50 opening. JNVX69: Ø23- 55 Cable flexi- ble leadthrough or M63 opening. FX48: Ø11-32 Cable flexible leadthrough or M40 opening. JNVX69: Ø17- 42 Cable flexi- ble leadthrough or M50 opening.
14 JNVX**-0210 182 200 JNVX48: 35-250 JNVX69: 35-150 JNVX48: 35- 150 JNVX69: 16-95 JNVX48: 35-250 (95-185)¹ JNVX69: 35-150 (16-70)¹ Ø23-55 cable flexible leadthrough or M63 opening. Ø17-42 cable flexible leadthrough or M50 opening.
15 JNVX**- 0228 216 250 JNVX48: 35-250 JNVX69: 35-150 JNVX48: 35- 150 JNVX69: 16-95 JNVX48: 35-250 (95-185)¹ JNVX69: 35-150 (16-70)¹ Ø23-55 cable flexible leadthrough or M63 opening. Ø17-42 cable flexible leadthrough or M50 opening.
16 JNVX**- 0250 216 250 JNVX48: 35-250 JNVX69: 35-150 JNVX48: 35- 150 JNVX69: 16-95 JNVX48: 35-250 (95-185)¹ JNVX69: 35-150 (16-70)¹ Ø23-55 cable flexible leadthrough or M63 opening. Ø17-42 cable flexible leadthrough or M50 opening.
17 JNVX**- 0300 260 300 JNVX48: (2x)35-240 JNVX69: (2x)35-150 JNVX48: (2x)35-240 JNVX69: (2x)35-150 frame --- --
18 JNVX**-0375 324 355 JNVX48: (2x)35-240 JNVX69: (2x)35-150 JNVX48: (2x)35-240 JNVX69: (2x)35-150 frame --- --

Manual — IEC cable continuation and chopper footnote — page 191

Manual reference: physical PDF page 191. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 48 Fuses, cable cross-sections and glands Note: For models 0003 to 0074 cable glands are optional. 1. Values are valid when brake chopper electronics are built in.

Table48 fuses cables and glands continuation — PDF page 191

Source row Model Nominal input current A Maximum fuse A Mains/motor connector mm² Brake connector mm² PE connector mm² Mains/motor gland mm Brake gland mm
1 JNVX**- 0430 372 400 JNVX48: (2x)35-240 JNVX69: (3x)35-150 JNVX48: (2x)35-240 JNVX69: (3x)35-150 frame -- --
2 JNVX**- 0500 432 500 JNVX48: (2x)35-240 JNVX69: (3x)35-150 JNVX48: (2x)35-240 JNVX69: (3x)35-150 frame -- --
3 JNVX**- 0600 520 630 JNVX48: (3x)35-240 JNVX69: (4x)35-150 JNVX48: (3x)35-240 JNVX69: (4x)35-150 frame -- --
4 JNVX**- 0650 562 630 JNVX48: (3x)35-240 JNVX69: (4x)35-150 JNVX48: (3x)35-240 JNVX69: (4x)35-150 frame -- --
5 JNVX**-0750 648 710 JNVX48: (3x)35-240 JNVX69: (6x)35-150 JNVX48: (3x)35-240 JNVX69: (6x)35-150 frame -- --
6 JNVX**- 0860 744 800 JNVX48: (4x)35-240 JNVX69: (6x)35-150 JNVX48: (4x)35-240 JNVX69: (6x)35-150 frame -- --
7 JNVX**- 0900 795 900 JNVX48: (4x)35-240 JNVX69: (6x)35-150 JNVX48: (4x)35-240 JNVX69: (6x)35-150 frame -- --
8 JNVX**-1000 864 1000 JNVX48: (4x)35-240 JNVX69: (6x)35-150 JNVX48: (4x)35-240 JNVX69: (6x)35-150 frame -- --
9 JNVX**- 1200 1037 1250 JNVX48: (6x)35-240 JNVX48: (6x)35-240 frame -- --
10 JNVX**- 1500 1296 1500 JNVX48: (6x)35-240 JNVX48: (6x)35-240 frame -- --

Manual — NEMA fuse sizes and types — page 192

Manual reference: physical PDF page 192. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.6.2 Fuses and cable dimensions according to NEMA ratings Table 49 Types and fuses

Table49 NEMA types and fuses — PDF page 192

Source row Model Input current Arms UL ClassJ TD A Ferraz-Shawmut type
1 JNVX48-0003 2,2 6 AJT6
2 JNVX48-0004 3,5 6 AJT6
3 JNVX48-0006 5,2 6 AJT6
4 JNVX48-0008 6,9 10 AJT10
5 JNVX48-0010 8,7 10 AJT10
6 JNVX48-0013 11,3 15 AJT15
7 JNVX48-0018 15,6 20 AJT20
8 JNVX48-0026 22 25 AJT25
9 JNVX48-0031 26 30 AJT30
10 JNVX48-0037 31 35 AJT35
11 JNVX48-0046 38 45 AJT45
12 JNVX48-0061 52 60 AJT60
13 JNVX48-0074 65 80 AJT80
14 JNVX48-0090 78 100 AJT100
15 JNVX48-0109 94 110 AJT110
16 JNVX48-0146 126 150 AJT150
17 JNVX48-0175 152 175 AJT175
18 JNVX48-0210 182 200 AJT200
19 JNVX48-0228 216 250 AJT250
20 JNVX48-0250 216 250 AJT250
21 JNVX48-0300 260 300 AJT300
22 JNVX48-0375 324 350 AJT350
23 JNVX48-0430 372 400 AJT400
24 JNVX48-0500 432 500 AJT500
25 JNVX48-0600 520 600 AJT600
26 JNVX48-0650 562 600 AJT600
27 JNVX48-0750 648 700 A4BQ700
28 JNVX48-0860 744 800 A4BQ800
29 JNVX48-1000 864 1000 A4BQ1000
30 JNVX48-1200 1037 1200 A4BQ1200
31 JNVX48-1500 1296 1500 A4BQ1500

Manual — NEMA cable ranges and torques small models — page 193

Manual reference: physical PDF page 193. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 50 Type cables cross-sections and glands

Table50 NEMA connector ranges and torques — PDF page 193

Source row Model Mains/motor range Mains/motor torque Nm/ftlbf Brake range Brake torque Nm/ftlbf PE range PE torque Nm/ftlbf Cable type
1 JNVX48- 0003 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
2 JNVX48- 0004 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
3 JNVX48- 0006 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
4 JNVX48- 0008 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
5 JNVX48- 0010 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
6 JNVX48- 0013 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
7 JNVX48- 0018 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
8 JNVX48- 0019 AWG 20 - AWG 6 1.3 / 1 AWG 20 - AWG 6 1.3 / 1 AWG 14 - AWG 6 2.6/2 Copper (Cu) 60°C
9 JNVX48- 0026 AWG 12 - AWG 4 1.3 / 1 AWG 12 - AWG 4 1.3 / 1 AWG 8 - AWG 2 2.6 / 2 output current <44A: Copper (Cu) 60°C output current >44A: Copper (Cu) 75°C
10 JNVX48- 0031 AWG 12 - AWG 4 1.3 / 1 AWG 12 - AWG 4 1.3 / 1 AWG 8 - AWG 2 2.6 / 2 output current <44A: Copper (Cu) 60°C output current >44A: Copper (Cu) 75°C
11 JNVX48- 0037 AWG 12 - AWG 4 1.3 / 1 AWG 12 - AWG 4 1.3 / 1 AWG 8 - AWG 2 2.6 / 2 output current <44A: Copper (Cu) 60°C output current >44A: Copper (Cu) 75°C
12 JNVX48- 0046 AWG 12 - AWG 4 1.3 / 1 AWG 12 - AWG 4 1.3 / 1 AWG 8 - AWG 2 2.6 / 2 output current <44A: Copper (Cu) 60°C output current >44A: Copper (Cu) 75°C

Manual — NEMA cable ranges and torques large models — page 194

Manual reference: physical PDF page 194. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Table 50 Type cables cross-sections and glands 1. Values are valid when brake chopper electronics are built in.

Table50 NEMA connector ranges and torques — PDF page 194

Source row Model Mains/motor range Mains/motor torque Nm/ftlbf Brake range Brake torque Nm/ftlbf PE range PE torque Nm/ftlbf Cable type
1 JNVX48- 0061 AWG 12–AWG 4 1.6/1.2 AWG 12–AWG 4 1.6/1.2 AWG 12–AWG 4 1.6/1.2 Copper (Cu) 75°C
2 JNVX48- 0074 AWG 10-AWG 0 2.8/3.0 AWG 10-AWG 0 2.8/3.0 AWG 10-AWG 0 2.8/3.0 Copper (Cu) 75°C
3 JNVX48- 0090 AWG 4 - AWG 3/0 14 / 10.5 AWG 4 - AWG 3/0 14 / 10.5 AWG 4 - AWG 3/0 (AWG 4 - AWG 2/0)¹ 14 / 10.5 (10 / 7.5)¹ Copper (Cu) 75°C
4 JNVX48- 0109 AWG 4 - AWG 3/0 14 / 10.5 AWG 4 - AWG 3/0 14 / 10.5 AWG 4 - AWG 3/0 (AWG 4 - AWG 2/0)¹ 14 / 10.5 (10 / 7.5)¹ Copper (Cu) 75°C
5 JNVX48- 0146 AWG 1 - AWG 3/0 AWG 4/0 - 300 kcmil 14 / 10.5 24 / 18 AWG 4 - AWG 3/0 14 / 10.5 AWG 1 - AWG 3/0 (AWG 4 - AWG 2/0)¹ 14 / 10.5 (10 / 7.5)¹ Copper (Cu) 75°C
6 JNVX48- 0175 AWG 1 - AWG 3/0 AWG 4/0 - 300 kcmil 14 / 10.5 24 / 18 AWG 4 - AWG 3/0 14 / 10.5 AWG 1 - AWG 3/0 (AWG 4 - AWG 2/0)¹ 14 / 10.5 (10 / 7.5)¹ Copper (Cu) 75°C
7 JNVX48- 0210 AWG 3/0 - 400 kcmil 24 / 18 AWG 1 - AWG 3/0 AWG 4/0 - 300 kcmil 14 / 10.5 24 / 18 AWG 3/0 - 400 kcmil (AWG 4/0 - 400 kcmil)¹ 24 / 18 (10 / 7.5)¹ Copper (Cu) 75°C
8 JNVX48- 0228 AWG 3/0 - 400 kcmil 24 / 18 AWG 1 - AWG 3/0 AWG 4/0 - 300 kcmil 14 / 10.5 24 / 18 AWG 3/0 - 400 kcmil (AWG 4/0 - 400 kcmil)¹ 24 / 18 (10 / 7.5)¹ Copper (Cu) 75°C
9 JNVX48- 0250 AWG 3/0 - 400 kcmil 24 / 18 AWG 1 - AWG 3/0 AWG 4/0 - 300 kcmil 14 / 10.5 24 / 18 AWG 3/0 - 400 kcmil (AWG 4/0 - 400 kcmil)¹ 24 / 18 (10 / 7.5)¹ Copper (Cu) 75°C
10 JNVX48- 0300 2 x AWG 4/0 - 2 x 300 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
11 JNVX48- 0375 2 x AWG 4/0 - 2 x 300 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
12 JNVX48- 0430 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
13 JNVX48- 0500 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
14 JNVX48- 0600 3 x AWG 4/0 - 3 x 300 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
15 JNVX48- 0650 3 x AWG 4/0 - 3 x 300 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
16 JNVX48- 0750 3 x AWG 4/0 - 3 x 300 kcmil 24 / 18 2 x AWG 3/0 - 2 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
17 JNVX48- 0860 4 x AWG 4/0 - 4 x 300 kcmil 24 / 18 3 x AWG 3/0 - 3 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
18 JNVX48- 1000 4 x AWG 4/0 - 4 x 300 kcmil 24 / 18 3 x AWG 3/0 - 3 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
19 JNVX48- 1200 6 x AWG 4/0 - 6 x 300 kcmil 24 / 18 6 x AWG 3/0 - 6 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C
20 JNVX48- 1500 6 x AWG 4/0 - 6 x 300 kcmil 24 / 18 6 x AWG 3/0 - 6 x 400 kcmil 24 / 18 frame - Copper (Cu) 75°C

Manual — Control signals X1 X2 X3 terminal table — page 195

Manual reference: physical PDF page 195. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

14.7 Control signals Table 51

Table51 X1 control terminals — PDF page 195

Source row Terminal Name Function default Signal Type
1 1 +10 V +10 VDC Supply voltage +10 VDC, max 10 mA output
2 2 AnIn1 Process reference 0 -10 VDC or 0/4–20 mA bipolar: -10 - +10 VDC or -20 - +20 mA analogue input
3 3 AnIn2 Off 0 -10 VDC or 0/4–20 mA bipolar: -10 - +10 VDC or -20 - +20 mA analogue input
4 4 AnIn3 Off 0 -10 VDC or 0/4–20 mA bipolar: -10 - +10 VDC or -20 - +20 mA analogue input
5 5 AnIn4 Off 0 -10 VDC or 0/4–20 mA bipolar: -10 - +10 VDC or -20 - +20 mA analogue input
6 6 -10 V -10VDC Supply voltage -10 VDC, max 10 mA output
7 7 Common Signal ground 0V output
8 8 DigIn 1 RunL 0-8/24 VDC digital input
9 9 DigIn 2 RunR 0-8/24 VDC digital input
10 10 DigIn 3 Off 0-8/24 VDC digital input
11 11 +24 V +24VDC Supply voltage +24 VDC, 100 mA output
12 12 Common Signal ground 0 V output
13 13 AnOut 1 Min speed to max speed 0 ±10 VDC or 0/4– +20 mA analogue output
14 14 AnOut 2 0 to max torque 0 ±10 VDC or 0/4– +20 mA analogue output
15 15 Common Signal ground 0 V output
16 16 DigIn 4 Off 0-8/24 VDC digital input
17 17 DigIn 5 Off 0-8/24 VDC digital input
18 18 DigIn 6 Off 0-8/24 VDC digital input
19 19 DigIn 7 Off 0-8/24 VDC digital input
20 20 DigOut 1 Ready 24 VDC, 100 mA digital output
21 21 DigOut 2 Brake 24 VDC, 100 mA digital output
22 22 DigIn 8 RESET 0-8/24 VDC digital input

Table51 X2 control terminals — PDF page 195

Source row Terminal Name Function default Signal Type
1 31 N/C 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition N/C is opened when the relay is active (valid for all relays) N/O is closed when the relay is active (valid for all relays) potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
2 32 COM 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition N/C is opened when the relay is active (valid for all relays) N/O is closed when the relay is active (valid for all relays) potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
3 33 N/O 1 Relay 1 output Trip, active when the AC drive is in a TRIP condition N/C is opened when the relay is active (valid for all relays) N/O is closed when the relay is active (valid for all relays) potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
4 41 N/C 2 Relay 2 Output Run, active when the AC drive is started potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
5 42 COM 2 Relay 2 Output Run, active when the AC drive is started potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
6 43 N/O 2 Relay 2 Output Run, active when the AC drive is started potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output

Table51 X3 control terminals — PDF page 195

Source row Terminal Name Function default Signal Type
1 51 COM 3 Relay 3 Output Off potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output
2 52 N/O 3 Relay 3 Output Off potential free change over 0.1 – 2 A/Umax 250 VAC or 42 VDC relay output

Manual — Menu list operation motor protection and communications — page 196

Manual reference: physical PDF page 196. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

  1. Menu List

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Menu List right column — PDF page 196

Source row Menu number Menu label Printed default Custom blank
1 256 Motor Lost Off ⟦blank source cell⟧
2 257 Locked Rotor Off ⟦blank source cell⟧
3 258 Power Fault Off ⟦blank source cell⟧
4 259 Undervoltage Off ⟦blank source cell⟧
5 25A Motor I²t Off ⟦blank source cell⟧
6 25B Motor I²t TT Trip ⟦blank source cell⟧
7 25C PT100 Off ⟦blank source cell⟧
8 25D PT100 TT Trip ⟦blank source cell⟧
9 25E PTC Off ⟦blank source cell⟧
10 25F PTC TT Trip ⟦blank source cell⟧
11 25G Ext Trip Off ⟦blank source cell⟧
12 25H Ext Trip TT Trip ⟦blank source cell⟧
13 25I Com Error Off ⟦blank source cell⟧
14 25J Com Error TT Trip ⟦blank source cell⟧
15 25K Min Alarm Off ⟦blank source cell⟧
16 25L Min Alarm TT Trip ⟦blank source cell⟧
17 25M Max Alarm Off ⟦blank source cell⟧
18 25N Max Alarm TT Trip ⟦blank source cell⟧
19 25O Over curr F Off ⟦blank source cell⟧
20 25Q Over speed Off ⟦blank source cell⟧
21 25R Ext Mot Temp Off ⟦blank source cell⟧
22 25S Ext Mot TT Trip ⟦blank source cell⟧
23 25T LC Level Off ⟦blank source cell⟧
24 25U LC Level TT Trip ⟦blank source cell⟧
25 25V Brk Fault Off ⟦blank source cell⟧
26 260 Serial Com ⟦blank source cell⟧ ⟦blank source cell⟧
27 261 Com Type RS232/485 ⟦blank source cell⟧
28 262 RS232/485 ⟦blank source cell⟧ ⟦blank source cell⟧
29 2621 Baudrate 9600 ⟦blank source cell⟧
30 2622 Address 1 ⟦blank source cell⟧
31 263 Fieldbus ⟦blank source cell⟧ ⟦blank source cell⟧
32 2631 Address 62 ⟦blank source cell⟧
33 2632 PrData Mode Basic ⟦blank source cell⟧
34 2633 Read/Write RW ⟦blank source cell⟧
35 2634 AddPrValue 0 ⟦blank source cell⟧
36 264 Comm Fault ⟦blank source cell⟧ ⟦blank source cell⟧
37 2641 ComFlt Mode Off ⟦blank source cell⟧
38 2642 ComFlt Time 0.5 s ⟦blank source cell⟧
39 265 Ethernet ⟦blank source cell⟧ ⟦blank source cell⟧
40 2651 IP Address 0.0.0.0 ⟦blank source cell⟧
41 2652 MAC Address 000000000000 ⟦blank source cell⟧
42 2653 Subnet Mask 0.0.0.0 ⟦blank source cell⟧
43 2654 Gateway 0.0.0.0 ⟦blank source cell⟧
44 2655 DHCP Off ⟦blank source cell⟧
45 266 FB Signal ⟦blank source cell⟧ ⟦blank source cell⟧
46 2661 FB Signal 1 0 ⟦blank source cell⟧
47 2662 FB Signal 2 0 ⟦blank source cell⟧
48 2663 FB Signal 3 0 ⟦blank source cell⟧
49 2664 FB Signal 4 0 ⟦blank source cell⟧
50 2665 FB Signal 5 0 ⟦blank source cell⟧
51 2666 FB Signal 6 0 ⟦blank source cell⟧
52 2667 FB Signal 7 0 ⟦blank source cell⟧
53 2668 FB Signal 8 0 ⟦blank source cell⟧
54 2669 FB Signal 9 0 ⟦blank source cell⟧

Menu List left column — PDF page 196

Source row Menu number Menu label Printed default Custom blank
1 100 Preferred View ⟦blank source cell⟧ ⟦blank source cell⟧
2 110 1st Line Process Val ⟦blank source cell⟧
3 120 2nd Line Torque ⟦blank source cell⟧
4 200 Main Setup ⟦blank source cell⟧ ⟦blank source cell⟧
5 210 Operation ⟦blank source cell⟧ ⟦blank source cell⟧
6 211 Language English ⟦blank source cell⟧
7 212 Select Motor M1 ⟦blank source cell⟧
8 213 Drive Mode Speed ⟦blank source cell⟧
9 214 Ref Control Remote ⟦blank source cell⟧
10 215 Run/Stp Ctrl Remote ⟦blank source cell⟧
11 216 Reset Ctrl Remote ⟦blank source cell⟧
12 217 Local/Rem ⟦blank source cell⟧ ⟦blank source cell⟧
13 2171 LocRefCtrl Standard ⟦blank source cell⟧
14 2172 LocRunCtrl Standard ⟦blank source cell⟧
15 218 Lock Code? 0 ⟦blank source cell⟧
16 219 Rotation R+L ⟦blank source cell⟧
17 21A Level/Edge Level ⟦blank source cell⟧
18 21B Supply Volts Not Defined ⟦blank source cell⟧
19 220 Motor Data ⟦blank source cell⟧ ⟦blank source cell⟧
20 221 Motor Volts UNOM V ⟦blank source cell⟧
21 222 Motor Freq 50Hz ⟦blank source cell⟧
22 223 Motor Power (PNOM) W ⟦blank source cell⟧
23 224 Motor Curr (IMOT) A ⟦blank source cell⟧
24 225 Motor Speed (nMOT) rpm ⟦blank source cell⟧
25 226 Motor Poles 4 ⟦blank source cell⟧
26 227 Motor Cosϕ CosφNOM ⟦blank source cell⟧
27 228 Motor Vent Self ⟦blank source cell⟧
28 229 Motor ID-Run Off ⟦blank source cell⟧
29 22B Encoder Off ⟦blank source cell⟧
30 22C Enc Pulses 1024 ⟦blank source cell⟧
31 22D Enc Speed 0rpm ⟦blank source cell⟧
32 230 Mot Protect ⟦blank source cell⟧ ⟦blank source cell⟧
33 231 Mot I²t Type Trip ⟦blank source cell⟧
34 232 Mot I²t Curr 100% ⟦blank source cell⟧
35 233 Mot I²t Time 60s ⟦blank source cell⟧
36 234 Thermal Prot Off ⟦blank source cell⟧
37 235 Motor Class F 140°C ⟦blank source cell⟧
38 236 PT100 Inputs PT100 1+2+3 ⟦blank source cell⟧
39 237 Motor PTC Off ⟦blank source cell⟧
40 240 Set Handling ⟦blank source cell⟧ ⟦blank source cell⟧
41 241 Select Set A ⟦blank source cell⟧
42 242 Copy Set A>B ⟦blank source cell⟧
43 243 Default>Set A ⟦blank source cell⟧
44 244 Copy to CP No Copy ⟦blank source cell⟧
45 245 Load from CP No Copy ⟦blank source cell⟧
46 250 Autoreset ⟦blank source cell⟧ ⟦blank source cell⟧
47 251 No of Trips 0 ⟦blank source cell⟧
48 252 Overtemp Off ⟦blank source cell⟧
49 253 Overvolt D Off ⟦blank source cell⟧
50 254 Overvolt G Off ⟦blank source cell⟧
51 255 Overvolt Off ⟦blank source cell⟧

Manual — Menu list process control and pump parameters — page 197

Manual reference: physical PDF page 197. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Menu List left column — PDF page 197

Source row Menu number Menu label Printed default Custom blank
1 266A FB Signal 10 0 ⟦blank source cell⟧
2 266B FB Signal 11 0 ⟦blank source cell⟧
3 266C FB Signal 12 0 ⟦blank source cell⟧
4 266D FB Signal 13 0 ⟦blank source cell⟧
5 266E FB Signal 14 0 ⟦blank source cell⟧
6 266F FB Signal 15 0 ⟦blank source cell⟧
7 266G FB Signal 16 0 ⟦blank source cell⟧
8 269 FB Status ⟦blank source cell⟧ ⟦blank source cell⟧
9 300 Process ⟦blank source cell⟧ ⟦blank source cell⟧
10 310 Set/View ref 0rpm ⟦blank source cell⟧
11 320 Proc Setting ⟦blank source cell⟧ ⟦blank source cell⟧
12 321 Proc Source Speed ⟦blank source cell⟧
13 322 Proc Unit rpm ⟦blank source cell⟧
14 323 User Unit 0 ⟦blank source cell⟧
15 324 Process Min 0 ⟦blank source cell⟧
16 325 Process Max 0 ⟦blank source cell⟧
17 326 Ratio Linear ⟦blank source cell⟧
18 327 F(Val) PrMin Min ⟦blank source cell⟧
19 328 F(Val) PrMax Max ⟦blank source cell⟧
20 330 Start/Stop ⟦blank source cell⟧ ⟦blank source cell⟧
21 331 Acc Time 10.00s ⟦blank source cell⟧
22 332 Dec Time 10.00s ⟦blank source cell⟧
23 333 Acc MotPot 16.00s ⟦blank source cell⟧
24 334 Dec MotPot 16.00s ⟦blank source cell⟧
25 335 Acc>Min Spd 10.00s ⟦blank source cell⟧
26 336 Dec<Min Spd 10.00s ⟦blank source cell⟧
27 337 Acc Rmp Linear ⟦blank source cell⟧
28 338 Dec Rmp Linear ⟦blank source cell⟧
29 339 Start Mode Normal DC ⟦blank source cell⟧
30 33A Spinstart Off ⟦blank source cell⟧
31 33B Stop Mode Decel ⟦blank source cell⟧
32 33C Brk Release 0.00s ⟦blank source cell⟧
33 33D Release Spd 0rpm ⟦blank source cell⟧
34 33E Brk Engage 0.00s ⟦blank source cell⟧
35 33F Brk Wait 0.00s ⟦blank source cell⟧
36 33G Vector Brake Off ⟦blank source cell⟧
37 33H Brk Fault 1.00s ⟦blank source cell⟧
38 33I Release Torque 0% ⟦blank source cell⟧
39 340 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
40 341 Min Speed 0rpm ⟦blank source cell⟧
41 342 Stp<MinSpd Off ⟦blank source cell⟧
42 343 Max Speed Sync Speed ⟦blank source cell⟧
43 344 SkipSpd 1 Lo 0rpm ⟦blank source cell⟧
44 345 SkipSpd 1 Hi 0rpm ⟦blank source cell⟧
45 346 SkipSpd 2 Lo 0rpm ⟦blank source cell⟧
46 347 SkipSpd 2 Hi 0rpm ⟦blank source cell⟧
47 348 Jog Speed 50rpm ⟦blank source cell⟧
48 350 Torques ⟦blank source cell⟧ ⟦blank source cell⟧
49 351 Max Torque 120% ⟦blank source cell⟧
50 352 IxR Comp Off ⟦blank source cell⟧
51 353 IxR CompUsr 0% ⟦blank source cell⟧
52 354 Flux optim Off ⟦blank source cell⟧
53 355 Max Power Off ⟦blank source cell⟧
54 360 Preset Ref ⟦blank source cell⟧ ⟦blank source cell⟧

Menu List right column — PDF page 197

Source row Menu number Menu label Printed default Custom blank
1 361 Motor Pot Non Volatile ⟦blank source cell⟧
2 362 Preset Ref 1 0 rpm ⟦blank source cell⟧
3 363 Preset Ref 2 250 rpm ⟦blank source cell⟧
4 364 Preset Ref 3 500 rpm ⟦blank source cell⟧
5 365 Preset Ref 4 750 rpm ⟦blank source cell⟧
6 366 Preset Ref 5 1000 rpm ⟦blank source cell⟧
7 367 Preset Ref 6 1250 rpm ⟦blank source cell⟧
8 368 Preset Ref 7 1500 rpm ⟦blank source cell⟧
9 369 Keyb Ref Mot Pot ⟦blank source cell⟧
10 370 Spd Ctrl PI ⟦blank source cell⟧ ⟦blank source cell⟧
11 371 Spd PI Auto Off ⟦blank source cell⟧
12 372 Spd P Gain ⟦blank source cell⟧ ⟦blank source cell⟧
13 373 Spd I Time ⟦blank source cell⟧ ⟦blank source cell⟧
14 380 ProcCtrlPID ⟦blank source cell⟧ ⟦blank source cell⟧
15 381 PID Control Off ⟦blank source cell⟧
16 383 PID P Gain 1.0 ⟦blank source cell⟧
17 384 PID I Time 1.00s ⟦blank source cell⟧
18 385 PID D Time 0.00s ⟦blank source cell⟧
19 386 PID<MinSpd Off ⟦blank source cell⟧
20 387 PID Act Marg 0 ⟦blank source cell⟧
21 388 PID Stdy Tst Off ⟦blank source cell⟧
22 389 PID Stdy Mar 0 ⟦blank source cell⟧
23 390 Pump/Fan Ctrl ⟦blank source cell⟧ ⟦blank source cell⟧
24 391 Pump enable Off ⟦blank source cell⟧
25 392 No of Drives 2 ⟦blank source cell⟧
26 393 Select Drive Sequence ⟦blank source cell⟧
27 394 Change Cond Both ⟦blank source cell⟧
28 395 Change Timer 50h ⟦blank source cell⟧
29 396 Drives on Ch 0 ⟦blank source cell⟧
30 397 Upper Band 10% ⟦blank source cell⟧
31 398 Lower Band 10% ⟦blank source cell⟧
32 399 Start Delay 0s ⟦blank source cell⟧
33 39A Stop Delay 0s ⟦blank source cell⟧
34 39B Upp Band Lim 0% ⟦blank source cell⟧
35 39C Low Band Lim 0% ⟦blank source cell⟧
36 39D Settle Start 0s ⟦blank source cell⟧
37 39E TransS Start 60% ⟦blank source cell⟧
38 39F Settle Stop 0s ⟦blank source cell⟧
39 39G TransS Stop 60% ⟦blank source cell⟧
40 39H Run Time 1 00:00:00 ⟦blank source cell⟧
41 39H1 Rst Run Tm1 No ⟦blank source cell⟧
42 39I Run Time 2 00:00:00 ⟦blank source cell⟧
43 39I1 Rst Run Tm2 No ⟦blank source cell⟧
44 39J Run Time 3 00:00:00 ⟦blank source cell⟧
45 39J1 Rst Run Tm3 No ⟦blank source cell⟧
46 39K Run Time 4 00:00:00 ⟦blank source cell⟧
47 39K1 Rst Run Tm4 No ⟦blank source cell⟧
48 39L Run Time05 00:00:00 ⟦blank source cell⟧
49 39L1 Rst Run Tm5 No ⟦blank source cell⟧
50 39M Run Time 6 00:00:00 ⟦blank source cell⟧
51 39M1 Rst Run Tm6 No ⟦blank source cell⟧
52 39N Pump 123456 ⟦blank source cell⟧ ⟦blank source cell⟧
53 39P No of Backup 0 ⟦blank source cell⟧
54 3A0 Crane Option ⟦blank source cell⟧ ⟦blank source cell⟧

Manual — Menu list crane monitors and analogue inputs — page 198

Manual reference: physical PDF page 198. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Menu List left column — PDF page 198

Source row Menu number Menu label Printed default Custom blank
1 3A1 Crane enable Off ⟦blank source cell⟧
2 3A2 Control 4-Speed ⟦blank source cell⟧
3 3A3 Crane Relay 1 No trip ⟦blank source cell⟧
4 3A4 Crane Relay 2 Brake ⟦blank source cell⟧
5 3A5 PreLimSwSpd ⟦blank source cell⟧ ⟦blank source cell⟧
6 3A6 CrawlSpd H/R ⟦blank source cell⟧ ⟦blank source cell⟧
7 3A7 CrawlSpd L/L ⟦blank source cell⟧ ⟦blank source cell⟧
8 3A8 Speed 2 ⟦blank source cell⟧ ⟦blank source cell⟧
9 3A9 Speed 3 ⟦blank source cell⟧ ⟦blank source cell⟧
10 3AA Speed 4 ⟦blank source cell⟧ ⟦blank source cell⟧
11 3AB Dev Bandwidt ⟦blank source cell⟧ ⟦blank source cell⟧
12 3AC Dev Time ms ⟦blank source cell⟧
13 3AD LAFS Load Off ⟦blank source cell⟧
14 3AE Crane Inputs ⟦blank source cell⟧ ⟦blank source cell⟧
15 3AF CraneOutputs ⟦blank source cell⟧ ⟦blank source cell⟧
16 400 Monitor/Prot ⟦blank source cell⟧ ⟦blank source cell⟧
17 410 Load Monitor ⟦blank source cell⟧ ⟦blank source cell⟧
18 411 Alarm Select Off ⟦blank source cell⟧
19 412 Alarm trip Off ⟦blank source cell⟧
20 413 Ramp Alarm Off ⟦blank source cell⟧
21 414 Start Delay 2s ⟦blank source cell⟧
22 415 Load Type Basic ⟦blank source cell⟧
23 416 Max Alarm ⟦blank source cell⟧ ⟦blank source cell⟧
24 4161 MaxAlarmMar 15% ⟦blank source cell⟧
25 4162 MaxAlarmDel 0.1s ⟦blank source cell⟧
26 417 Max Pre alarm ⟦blank source cell⟧ ⟦blank source cell⟧
27 4171 MaxPreAlMar 10% ⟦blank source cell⟧
28 4172 MaxPreAlDel 0.1s ⟦blank source cell⟧
29 418 Min Pre Alarm ⟦blank source cell⟧ ⟦blank source cell⟧
30 4181 MinPreAlMar 10% ⟦blank source cell⟧
31 4182 MinPreAlDel 0.1s ⟦blank source cell⟧
32 419 Min Alarm ⟦blank source cell⟧ ⟦blank source cell⟧
33 4191 MinAlarmMar 15% ⟦blank source cell⟧
34 4192 MinAlarmDel 0.1s ⟦blank source cell⟧
35 41A Autoset Alrm No ⟦blank source cell⟧
36 41B Normal Load 100% ⟦blank source cell⟧
37 41C Load Curve ⟦blank source cell⟧ ⟦blank source cell⟧
38 41C1 Load Curve 1 100% ⟦blank source cell⟧
39 41C2 Load Curve 2 100% ⟦blank source cell⟧
40 41C3 Load Curve 3 100% ⟦blank source cell⟧
41 41C4 Load Curve 4 100% ⟦blank source cell⟧
42 41C5 Load Curve 5 100% ⟦blank source cell⟧
43 41C6 Load Curve 6 100% ⟦blank source cell⟧
44 41C7 Load Curve 7 100% ⟦blank source cell⟧
45 41C8 Load Curve 8 100% ⟦blank source cell⟧
46 41C9 Load Curve 9 100% ⟦blank source cell⟧
47 420 Process Prot ⟦blank source cell⟧ ⟦blank source cell⟧
48 421 Low Volt OR On ⟦blank source cell⟧
49 422 Rotor Locked Off ⟦blank source cell⟧
50 423 Motor lost Off ⟦blank source cell⟧
51 424 Overvolt Ctrl On ⟦blank source cell⟧
52 500 I/Os ⟦blank source cell⟧ ⟦blank source cell⟧
53 510 An Inputs ⟦blank source cell⟧ ⟦blank source cell⟧
54 511 AnIn1 Fc Process Ref ⟦blank source cell⟧

Menu List right column — PDF page 198

Source row Menu number Menu label Printed default Custom blank
1 512 AnIn1 Setup 4-20mA ⟦blank source cell⟧
2 513 AnIn1 Advn ⟦blank source cell⟧ ⟦blank source cell⟧
3 5131 AnIn1 Min 4mA ⟦blank source cell⟧
4 5132 AnIn1 Max 10.00V/ 20.00mA ⟦blank source cell⟧
5 5133 AnIn1 Bipol 10.00V/ 20.00mA ⟦blank source cell⟧
6 5134 AnIn1 FcMin Min ⟦blank source cell⟧
7 5135 AnIn1 ValMin 0 ⟦blank source cell⟧
8 5136 AnIn1 FcMax Max ⟦blank source cell⟧
9 5137 AnIn1 ValMax 0 ⟦blank source cell⟧
10 5138 AnIn1 Oper Add+ ⟦blank source cell⟧
11 5139 AnIn1 Filt 0.1s ⟦blank source cell⟧
12 513A AnIn1 Enabl On ⟦blank source cell⟧
13 514 AnIn2 Fc Off ⟦blank source cell⟧
14 515 AnIn2 Setup 4-20mA ⟦blank source cell⟧
15 516 AnIn2 Advan ⟦blank source cell⟧ ⟦blank source cell⟧
16 5161 AnIn2 Min 4mA ⟦blank source cell⟧
17 5162 AnIn2 Max 20.00mA ⟦blank source cell⟧
18 5163 AnIn2 Bipol 20.00mA ⟦blank source cell⟧
19 5164 AnIn2 FcMin Min ⟦blank source cell⟧
20 5165 AnIn2 ValMin 0 ⟦blank source cell⟧
21 5166 AnIn2 FcMax Max ⟦blank source cell⟧
22 5167 AnIn2 ValMax 0 ⟦blank source cell⟧
23 5168 AnIn2 Oper Add+ ⟦blank source cell⟧
24 5169 AnIn2 Filt 0.1s ⟦blank source cell⟧
25 516A AnIn2 Enabl On ⟦blank source cell⟧
26 517 AnIn3 Fc Off ⟦blank source cell⟧
27 518 AnIn3 Setup 4-20mA ⟦blank source cell⟧
28 519 AnIn3 Advan ⟦blank source cell⟧ ⟦blank source cell⟧
29 5191 AnIn3 Min 4mA ⟦blank source cell⟧
30 5192 AnIn3 Max 20.00mA ⟦blank source cell⟧
31 5193 AnIn3 Bipol 20.00mA ⟦blank source cell⟧
32 5194 AnIn3 FcMin Min ⟦blank source cell⟧
33 5195 AnIn3 ValMin 0 ⟦blank source cell⟧
34 5196 AnIn3 FcMax Max ⟦blank source cell⟧
35 5197 AnIn3 ValMax 0 ⟦blank source cell⟧
36 5198 AnIn3 Oper Add+ ⟦blank source cell⟧
37 5199 AnIn3 Filt 0.1s ⟦blank source cell⟧
38 519A AnIn3 Enabl On ⟦blank source cell⟧
39 51A AnIn4 Fc Off ⟦blank source cell⟧
40 51B AnIn4 Setup 4-20mA ⟦blank source cell⟧
41 51C AnIn4 Advan ⟦blank source cell⟧ ⟦blank source cell⟧
42 51C1 AnIn4 Min 4mA ⟦blank source cell⟧
43 51C2 AnIn4 Max 20.00mA ⟦blank source cell⟧
44 51C3 AnIn4 Bipol 20.00mA ⟦blank source cell⟧
45 51C4 AnIn4 FcMin Min ⟦blank source cell⟧
46 51C5 AnIn4 ValMin 0 ⟦blank source cell⟧
47 51C6 AnIn4 FcMax Max ⟦blank source cell⟧
48 51C7 AnIn4 ValMax 0 ⟦blank source cell⟧
49 51C8 AnIn4 Oper Add+ ⟦blank source cell⟧
50 51C9 AnIn4 Filt 0.1s ⟦blank source cell⟧
51 51CA AnIn4 Enabl On ⟦blank source cell⟧
52 520 Dig Inputs ⟦blank source cell⟧ ⟦blank source cell⟧
53 521 DigIn 1 RunL ⟦blank source cell⟧

Manual — Menu list outputs relays and comparators — page 199

Manual reference: physical PDF page 199. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Menu List left column — PDF page 199

Source row Menu number Menu label Printed default Custom blank
1 522 DigIn 2 RunR ⟦blank source cell⟧
2 523 DigIn 3 Off ⟦blank source cell⟧
3 524 DigIn 4 Off ⟦blank source cell⟧
4 525 DigIn 5 Off ⟦blank source cell⟧
5 526 DigIn 6 Off ⟦blank source cell⟧
6 527 DigIn 7 Off ⟦blank source cell⟧
7 528 DigIn 8 Reset ⟦blank source cell⟧
8 529 B(oard)1 DigIn 1 Off ⟦blank source cell⟧
9 52A B(oard)1 DigIn 2 Off ⟦blank source cell⟧
10 52B B(oard)1 DigIn 3 Off ⟦blank source cell⟧
11 52C B(oard)2 DigIn 1 Off ⟦blank source cell⟧
12 52D B(oard)2 DigIn 2 Off ⟦blank source cell⟧
13 52E B(oard)2 DigIn 3 Off ⟦blank source cell⟧
14 52F B(oard)3 DigIn 1 Off ⟦blank source cell⟧
15 52G B(oard)3 DigIn 2 Off ⟦blank source cell⟧
16 52H B(oard)3 DigIn 3 Off ⟦blank source cell⟧
17 530 An Outputs ⟦blank source cell⟧ ⟦blank source cell⟧
18 531 AnOut1 Fc Speed ⟦blank source cell⟧
19 532 AnOut1 Setup 4-20mA ⟦blank source cell⟧
20 533 AnOut1 Adv ⟦blank source cell⟧ ⟦blank source cell⟧
21 5331 AnOut 1 Min 4mA ⟦blank source cell⟧
22 5332 AnOut 1 Max 20.0mA ⟦blank source cell⟧
23 5333 AnOut1Bipol -10.00-10.00 V ⟦blank source cell⟧
24 5334 AnOut1 FcMin Min ⟦blank source cell⟧
25 5335 AnOut1 VlMin 0 ⟦blank source cell⟧
26 5336 AnOut1 FcMax Max ⟦blank source cell⟧
27 5337 AnOut1 VlMax 0 ⟦blank source cell⟧
28 534 AnOut2 FC Torque ⟦blank source cell⟧
29 535 AnOut2 Setup 4-20mA ⟦blank source cell⟧
30 536 AnOut2 Advan ⟦blank source cell⟧ ⟦blank source cell⟧
31 5361 AnOut 2 Min 4mA ⟦blank source cell⟧
32 5362 AnOut 2 Max 20.0mA ⟦blank source cell⟧
33 5363 AnOut2Bipol -10.00-10.00 V ⟦blank source cell⟧
34 5364 AnOut2 FcMin Min ⟦blank source cell⟧
35 5365 AnOut2 VlMin 0 ⟦blank source cell⟧
36 5366 AnOut2 FcMax Max ⟦blank source cell⟧
37 5367 AnOut2 VlMax 0 ⟦blank source cell⟧
38 540 Dig Outputs ⟦blank source cell⟧ ⟦blank source cell⟧
39 541 DigOut 1 Ready ⟦blank source cell⟧
40 542 DigOut 2 Brake ⟦blank source cell⟧
41 550 Relays ⟦blank source cell⟧ ⟦blank source cell⟧
42 551 Relay 1 Trip ⟦blank source cell⟧
43 552 Relay 2 Run ⟦blank source cell⟧
44 553 Relay 3 Off ⟦blank source cell⟧
45 554 B(oard)1 Relay 1 Off ⟦blank source cell⟧
46 555 B(oard)1 Relay 2 Off ⟦blank source cell⟧
47 556 B(oard)1 Relay 3 Off ⟦blank source cell⟧
48 557 B(oard)2 Relay 1 Off ⟦blank source cell⟧
49 558 B(oard)2 Relay 2 Off ⟦blank source cell⟧
50 559 B(oard)2 Relay 3 Off ⟦blank source cell⟧
51 55A B(oard)3 Relay 1 Off ⟦blank source cell⟧
52 55B B(oard)3 Relay 2 Off ⟦blank source cell⟧
53 55C B(oard)3 Relay 3 Off ⟦blank source cell⟧
54 55D Relay Adv ⟦blank source cell⟧ ⟦blank source cell⟧

Menu List right column — PDF page 199

Source row Menu number Menu label Printed default Custom blank
1 55D1 Relay 1 Mode N.O ⟦blank source cell⟧
2 55D2 Relay 2 Mode N.O ⟦blank source cell⟧
3 55D3 Relay 3 Mode N.O ⟦blank source cell⟧
4 55D4 B1R1 Mode N.O ⟦blank source cell⟧
5 55D5 B1R2 Mode N.O ⟦blank source cell⟧
6 55D6 B1R3 Mode N.O ⟦blank source cell⟧
7 55D7 B2R1 Mode N.O ⟦blank source cell⟧
8 55D8 B2R2 Mode N.O ⟦blank source cell⟧
9 55D9 B2R3 Mode N.O ⟦blank source cell⟧
10 55DA B3R1 Mode N.O ⟦blank source cell⟧
11 55DB B3R2 Mode N.O ⟦blank source cell⟧
12 55DC B3R3 Mode N.O ⟦blank source cell⟧
13 560 Virtual I/Os ⟦blank source cell⟧ ⟦blank source cell⟧
14 561 VIO 1 Dest Off ⟦blank source cell⟧
15 562 VIO 1 Source Off ⟦blank source cell⟧
16 563 VIO 2 Dest Off ⟦blank source cell⟧
17 564 VIO 2 Source Off ⟦blank source cell⟧
18 565 VIO 3 Dest Off ⟦blank source cell⟧
19 566 VIO 3 Source Off ⟦blank source cell⟧
20 567 VIO 4 Dest Off ⟦blank source cell⟧
21 568 VIO 4 Source Off ⟦blank source cell⟧
22 569 VIO 5 Dest Off ⟦blank source cell⟧
23 56A VIO 5 Source Off ⟦blank source cell⟧
24 56B VIO 6 Dest Off ⟦blank source cell⟧
25 56C VIO 6 Source Off ⟦blank source cell⟧
26 56D VIO 7 Dest Off ⟦blank source cell⟧
27 56E VIO 7 Source Off ⟦blank source cell⟧
28 56F VIO 8 Dest Off ⟦blank source cell⟧
29 56G VIO 8 Source Off ⟦blank source cell⟧
30 600 Logical&Timers ⟦blank source cell⟧ ⟦blank source cell⟧
31 610 Comparators ⟦blank source cell⟧ ⟦blank source cell⟧
32 611 CA1 Setup ⟦blank source cell⟧ ⟦blank source cell⟧
33 6111 CA1 Value Speed ⟦blank source cell⟧
34 6112 CA1 Level HI 300rpm ⟦blank source cell⟧
35 6113 CA1 Level LO 200rpm ⟦blank source cell⟧
36 6114 CA1 Type Hysteresis ⟦blank source cell⟧
37 6115 CA1 Bipolar Unipolar ⟦blank source cell⟧
38 612 CA2 Setup ⟦blank source cell⟧ ⟦blank source cell⟧
39 6121 CA2 Value Torque ⟦blank source cell⟧
40 6122 CA2 Level HI 20% ⟦blank source cell⟧
41 6123 CA2 Level LO 10% ⟦blank source cell⟧
42 6124 CA2 Type Hysteresis ⟦blank source cell⟧
43 6125 CA2 Bipolar Unipolar ⟦blank source cell⟧
44 613 CA3 Setup ⟦blank source cell⟧ ⟦blank source cell⟧
45 6131 CA3 Value Process Val ⟦blank source cell⟧
46 6132 CA3 Level HI 300rpm ⟦blank source cell⟧
47 6133 CA3 Level LO 200rpm ⟦blank source cell⟧
48 6134 CA3 Type Hysteresis ⟦blank source cell⟧
49 6135 CA3 Bipolar Unipolar ⟦blank source cell⟧
50 614 CA4 Setup ⟦blank source cell⟧ ⟦blank source cell⟧
51 6141 CA4 Value Process Err ⟦blank source cell⟧
52 6142 CA4 Level HI 100 rpm ⟦blank source cell⟧
53 6143 CA4 Level LO - 100 rpm ⟦blank source cell⟧
54 6144 CA4 Type Window ⟦blank source cell⟧

Manual — Menu list logic timers and operating status — page 200

Manual reference: physical PDF page 200. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Adjacent source context — repeated to preserve continuation:

Menu List left column — PDF page 200

Source row Menu number Menu label Printed default Custom blank
1 6145 CA4 Bipolar Bipolar ⟦blank source cell⟧
2 615 CD Setup ⟦blank source cell⟧ ⟦blank source cell⟧
3 6151 CD1 Run ⟦blank source cell⟧
4 6152 CD2 DigIn 1 ⟦blank source cell⟧
5 6153 CD3 Trip ⟦blank source cell⟧
6 6154 CD4 Ready ⟦blank source cell⟧
7 620 Logic Output Y ⟦blank source cell⟧ ⟦blank source cell⟧
8 621 Y Comp 1 CA1 ⟦blank source cell⟧
9 622 Y Operator 1 & ⟦blank source cell⟧
10 623 Y Comp 2 !A2 ⟦blank source cell⟧
11 624 Y Operator 2 & ⟦blank source cell⟧
12 625 Y Comp 3 CD1 ⟦blank source cell⟧
13 630 Logic Z ⟦blank source cell⟧ ⟦blank source cell⟧
14 631 Z Comp 1 CA1 ⟦blank source cell⟧
15 632 Z Operator 1 & ⟦blank source cell⟧
16 633 Z Comp2 !A2 ⟦blank source cell⟧
17 634 Z Operator 2 & ⟦blank source cell⟧
18 635 Z Comp 3 CD1 ⟦blank source cell⟧
19 640 Timer1 ⟦blank source cell⟧ ⟦blank source cell⟧
20 641 Timer1 Trig Off ⟦blank source cell⟧
21 642 Timer1 Mode Off ⟦blank source cell⟧
22 643 Timer1 Delay 0:00:00 ⟦blank source cell⟧
23 644 Timer 1 T1 0:00:00 ⟦blank source cell⟧
24 645 Timer1 T2 0:00:00 ⟦blank source cell⟧
25 649 Timer1 Value 0:00:00 ⟦blank source cell⟧
26 650 Timer2 ⟦blank source cell⟧ ⟦blank source cell⟧
27 651 Timer2 Trig Off ⟦blank source cell⟧
28 652 Timer2 Mode Off ⟦blank source cell⟧
29 653 Timer2 Delay 0:00:00 ⟦blank source cell⟧
30 654 Timer 2 T1 0:00:00 ⟦blank source cell⟧
31 655 Timer2 T2 0:00:00 ⟦blank source cell⟧
32 659 Tmer2 Value 0:00:00 ⟦blank source cell⟧
33 700 Oper/Status ⟦blank source cell⟧ ⟦blank source cell⟧
34 710 Operation ⟦blank source cell⟧ ⟦blank source cell⟧
35 711 Process Val ⟦blank source cell⟧ ⟦blank source cell⟧
36 712 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
37 713 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
38 714 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
39 715 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
40 716 Current ⟦blank source cell⟧ ⟦blank source cell⟧
41 717 Output volt ⟦blank source cell⟧ ⟦blank source cell⟧
42 718 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
43 719 DC Voltage ⟦blank source cell⟧ ⟦blank source cell⟧
44 71A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
45 71B PT100_1_2_3 ⟦blank source cell⟧ ⟦blank source cell⟧
46 720 Status ⟦blank source cell⟧ ⟦blank source cell⟧
47 721 AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
48 722 Warning ⟦blank source cell⟧ ⟦blank source cell⟧
49 723 DigIn Status ⟦blank source cell⟧ ⟦blank source cell⟧
50 724 DigOut Status ⟦blank source cell⟧ ⟦blank source cell⟧
51 725 AnIn Status 1-2 ⟦blank source cell⟧ ⟦blank source cell⟧
52 726 AnIn Status 3-4 ⟦blank source cell⟧ ⟦blank source cell⟧
53 727 AnOut Status 1-2 ⟦blank source cell⟧ ⟦blank source cell⟧
54 728 IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧

Menu List right column — PDF page 200

Source row Menu number Menu label Printed default Custom blank
1 729 IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
2 72A IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
3 730 Stored Val ⟦blank source cell⟧ ⟦blank source cell⟧
4 731 Run Time 00:00:00 ⟦blank source cell⟧
5 7311 Reset RunTm No ⟦blank source cell⟧
6 732 Mains Time 00:00:00 ⟦blank source cell⟧
7 733 Energy kWh ⟦blank source cell⟧
8 7331 Rst Energy No ⟦blank source cell⟧
9 800 View TripLog ⟦blank source cell⟧ ⟦blank source cell⟧
10 810 Trip Message ⟦blank source cell⟧ ⟦blank source cell⟧
11 811 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
12 812 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
13 813 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
14 814 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
15 815 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
16 816 Current ⟦blank source cell⟧ ⟦blank source cell⟧
17 817 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
18 818 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
19 819 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
20 81A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
21 81B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
22 81C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
23 81D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
24 81E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
25 81F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
26 81G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
27 81H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
28 81I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
29 81J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
30 81K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
31 81L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
32 81M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
33 81N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
34 820 Trip Message ⟦blank source cell⟧ ⟦blank source cell⟧
35 821 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
36 822 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
37 823 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
38 824 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
39 825 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
40 826 Current ⟦blank source cell⟧ ⟦blank source cell⟧
41 827 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
42 828 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
43 829 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
44 82A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
45 82B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
46 82C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
47 82D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
48 82E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
49 82F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
50 82G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
51 82H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
52 82I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
53 82J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
54 82K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧

Manual — Menu list trip histories continuation — page 201

Manual reference: physical PDF page 201. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Adjacent source context — repeated to preserve continuation:

Menu List left column — PDF page 201

Source row Menu number Menu label Printed default Custom blank
1 82L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
2 82M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
3 82N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
4 830 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
5 831 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
6 832 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
7 833 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
8 834 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
9 835 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
10 836 Current ⟦blank source cell⟧ ⟦blank source cell⟧
11 837 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
12 838 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
13 839 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
14 83A Heatsink Temperature ⟦blank source cell⟧ ⟦blank source cell⟧
15 83B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
16 83C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
17 83D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
18 83E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
19 83F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
20 83G AIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
21 83H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
22 83I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
23 83J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
24 83K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
25 83L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
26 83M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
27 83N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
28 840 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
29 841 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
30 842 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
31 843 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
32 844 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
33 845 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
34 846 Current ⟦blank source cell⟧ ⟦blank source cell⟧
35 847 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
36 848 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
37 849 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
38 84A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
39 84B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
40 84C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
41 84D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
42 84E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
43 84F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
44 84G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
45 84H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
46 84I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
47 84J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
48 84K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
49 84L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
50 84M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
51 84N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
52 850 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
53 851 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
54 852 Speed ⟦blank source cell⟧ ⟦blank source cell⟧

Menu List right column — PDF page 201

Source row Menu number Menu label Printed default Custom blank
1 853 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
2 854 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
3 855 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
4 856 Current ⟦blank source cell⟧ ⟦blank source cell⟧
5 857 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
6 858 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
7 859 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
8 85A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
9 85B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
10 85C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
11 85D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
12 85E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
13 85F AnIn 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
14 85G AnIn 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
15 85H AnIOut 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
16 85I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
17 85J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
18 85K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
19 85L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
20 85M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
21 85N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
22 860 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
23 861 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
24 862 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
25 863 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
26 864 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
27 865 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
28 866 Current ⟦blank source cell⟧ ⟦blank source cell⟧
29 867 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
30 868 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
31 869 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
32 86A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
33 86B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
34 86C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
35 86D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
36 86E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
37 86F AnIn 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
38 86G AnIn 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
39 86H AnOut 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
40 86I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
41 86J IO Status B 2 ⟦blank source cell⟧ ⟦blank source cell⟧
42 86K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
43 86L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
44 86M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
45 86N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
46 870 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
47 871 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
48 872 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
49 873 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
50 874 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
51 875 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
52 876 Current ⟦blank source cell⟧ ⟦blank source cell⟧
53 877 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
54 878 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧

Manual — Menu list trip histories and system data — page 202

Manual reference: physical PDF page 202. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Printed menu index/default list, separate evidence from detailed parameter pages. Blank cells stay blank. Group headings and live-status values are not defaults. No value propagated across blank or merged cells; custom column is unfilled.

Menu List left column — PDF page 202

Source row Menu number Menu label Printed default Custom blank
1 879 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
2 87A Heatsink Tmpe ⟦blank source cell⟧ ⟦blank source cell⟧
3 87B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
4 87C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
5 87D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
6 87E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
7 87F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
8 87G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
9 87H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
10 87I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
11 87J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
12 87K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
13 87L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
14 87M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
15 87N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
16 880 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
17 881 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
18 882 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
19 818 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
20 884 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
21 885 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
22 886 Current ⟦blank source cell⟧ ⟦blank source cell⟧
23 887 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
24 888 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
25 889 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
26 88A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
27 88B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
28 88C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
29 88D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
30 88E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧
31 88F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
32 88G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
33 88H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
34 88I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
35 88J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
36 88K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
37 88L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
38 88M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
39 88N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
40 890 ⟦blank source cell⟧ ⟦blank source cell⟧ ⟦blank source cell⟧
41 891 Process Value ⟦blank source cell⟧ ⟦blank source cell⟧
42 892 Speed ⟦blank source cell⟧ ⟦blank source cell⟧
43 893 Torque ⟦blank source cell⟧ ⟦blank source cell⟧
44 894 Shaft Power ⟦blank source cell⟧ ⟦blank source cell⟧
45 895 Electrical Power ⟦blank source cell⟧ ⟦blank source cell⟧
46 896 Current ⟦blank source cell⟧ ⟦blank source cell⟧
47 897 Output voltage ⟦blank source cell⟧ ⟦blank source cell⟧
48 898 Frequency ⟦blank source cell⟧ ⟦blank source cell⟧
49 899 DC Link voltage ⟦blank source cell⟧ ⟦blank source cell⟧
50 89A Heatsink Tmp ⟦blank source cell⟧ ⟦blank source cell⟧
51 89B PT100_1, 2, 3 ⟦blank source cell⟧ ⟦blank source cell⟧
52 89C AC drive Status ⟦blank source cell⟧ ⟦blank source cell⟧
53 89D DigIn status ⟦blank source cell⟧ ⟦blank source cell⟧
54 89E DigOut status ⟦blank source cell⟧ ⟦blank source cell⟧

Menu List right column — PDF page 202

Source row Menu number Menu label Printed default Custom blank
1 89F AnIn status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
2 89G AnIn status 3 4 ⟦blank source cell⟧ ⟦blank source cell⟧
3 89H AnOut status 1 2 ⟦blank source cell⟧ ⟦blank source cell⟧
4 89I IO Status B1 ⟦blank source cell⟧ ⟦blank source cell⟧
5 89J IO Status B2 ⟦blank source cell⟧ ⟦blank source cell⟧
6 89K IO Status B3 ⟦blank source cell⟧ ⟦blank source cell⟧
7 89L Run Time ⟦blank source cell⟧ ⟦blank source cell⟧
8 89M Mains Time ⟦blank source cell⟧ ⟦blank source cell⟧
9 89N Energy ⟦blank source cell⟧ ⟦blank source cell⟧
10 8A0 Reset Trip No ⟦blank source cell⟧
11 900 System Data ⟦blank source cell⟧ ⟦blank source cell⟧
12 920 AC drive Data ⟦blank source cell⟧ ⟦blank source cell⟧
13 921 AC drive Type ⟦blank source cell⟧ ⟦blank source cell⟧
14 922 Software ⟦blank source cell⟧ ⟦blank source cell⟧
15 923 Unit name 0 ⟦blank source cell⟧

Manual — Menu List — page 203

Manual reference: physical PDF page 203. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Visually footer-only; no engineering table or body content.

Manual — Alphabetical index symbols through K — page 204

Manual reference: physical PDF page 204. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Index Symbols +10VDC Supply voltage ................192 +24VDC Supply voltage ................192 Numerics -10VDC Supply voltage .................192 Menu 78, 80, 81, 96, 98, 110, 111, 112, 115, ........................................118 4-20mA .........................................121 Menu ...............................119, 121, 122 A Abbreviations .....................................8 Acceleration ...............................86, 88 Acceleration ramp .....................88 Acceleration time ......................86 Ramp type ................................88 Alarm trip ......................................113 Alternating MASTER ....................104 Ambient temperature and derating 184 Analogue comparators ...................136 Analogue input ..............................119 AnIn1 .....................................119 AnIn2 .............................124, 125 Offset .............................120, 128 Analogue Output ...........128, 131, 192 AnOut 1 .........................128, 131 Output configuration .....128, 131 AND operator ...............................147 AnIn2 ............................................124 AnIn3 ............................................125 AnIn4 ............................................125 Autoreset .......................2, 38, 71, 166 Autotune .........................................99 B Baudrate ..............................49, 78, 79 Brake chopper ................................172 Brake function ...........................90, 91 Bake release time ......................90 Brake ........................................91 Brake Engage Time ..................91 Brake wait time ........................92 Release speed ............................91 Vector Brake .............................92 Brake functions Frequency ...............................119 Brake resistors ................................172 C Cable cross-section .........................187 Cable specifications ..........................20 CE-marking .......................................7 Change Condition .........................105

Change Timer ................................105 Clockwise rotary field .....................126 Com Type ........................................78 Comparators ..................................136 Connecting control signals ...............26 Connections Brake chopper connections .......16 Control signal connections ........26 Mains supply ......................16, 29 Motor earth ........................16, 29 Motor output ......................16, 29 Safety earth .........................16, 29 Control panel ...................................45 Control Panel memory .....................40 Copy all settings to Control Panel . 70 Frequency ...............................119 Control signal connections ...............26 Control signals ...........................24, 27 Edge-controlled ..................39, 60 Level-controlled ..................39, 60 Counter-clockwise rotary field .......126 Crane Option ................................110 ctrical .............................................154 Current ............................................24 Current control (0-20mA) ...............28 D DC-link residual voltage ....................2 Deceleration .....................................87 Deceleration time .....................87 Ramp type ................................89 Declaration of Conformity .................7 Default .............................................70 Definitions .........................................8 Derating .........................................184 Digital comparators ........................136 Digital inputs Board Relay ............................134 DigIn 1 ...................................126 DigIn 2 ...................................127 DigIn 3 ...................................127 Dismantling and scrapping ................7 Display .............................................45 Double-ended connection ................27 Drive mode ......................................57 Frequency ...............................119 Drives on Change ..........................105 E ECP ...............................................171 Edge control .........................39, 60, 61 Electrical specification ....................183 EMC ................................................16 Current control (0-20mA) ........28 Double-ended connection .........27 RFI mains filter .........................16

Single-ended connection .......... 27 Twisted cables .......................... 28 Emergency stop ............................... 43 EN60204-1 ....................................... 7 EN61800-3 ....................................... 7 EN61800-5-1 .................................... 7 Enable ............................... 37, 47, 126 EXOR operator ............................. 147 Expression ..................................... 147 External Control Panel .................. 171 F Factory settings ................................ 70 Fans ............................................... 104 Fieldbus ................................... 79, 174 Fixed MASTER ............................. 104 Flux optimization ............................ 97 Frequency Frequency priority .................... 36 Jog Frequency .......................... 95 Maximum Frequency ......... 93, 94 Minimum Frequency ............... 93 Preset Frequency ...................... 98 Skip Frequency .................. 94, 95 Frequency priority ........................... 36 Fuses, cable cross-sections and glands .. 187 G General electrical specifications ..... 183 Global parameters ........................... 68 I I/O Board ...................................... 173 I2t protection Motor I2t Current ............. 66, 67 Motor I2t Type ........................ 65 ID run ....................................... 40, 64 Identification Run ..................... 40, 64 IEC269 ......................................... 187 Internal speed control ...................... 99 Internal speed controller .................. 99 Speed I Time .......................... 100 Speed P Gain ......................... 100 Interrupt ................................... 80, 81 IT Mains supply ................................ 2 IxR Compensation .......................... 96 J Jog Frequency ................................. 95 K Keyboard reference .......................... 99 Keys ................................................ 47 - Key ........................................ 48 + Key ....................................... 48

Manual — Alphabetical and menu index continuation — page 205

Manual reference: physical PDF page 205. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

Control keys .............................47 ENTER key ..............................48 ESCAPE key .............................48 Function keys ...........................48 NEXT key ................................48 PREVIOUS key .......................48 RUN L .....................................47 RUN R .....................................47 STOP/RESET ..........................47 Toggle Key ...............................47 L LCD display ....................................45 Level control ..............................39, 60 Load default .....................................70 Load monitor ...........................41, 113 Local/Remote ..................................59 Lock code ........................................60 Long motor cables ...........................18 Low Voltage Directive .......................7 Lower Band ...................................106 Lower Band Limit ..........................107 M Machine Directive .............................7 Main menu ......................................49 Mains supply .......................16, 23, 29 Maintenance ..................................170 Manis cables ....................................15 Max Frequency ..........................86, 94 Memory ...........................................40 Menu (110) ........................................55 (120) ........................................56 (210) ........................................56 (211) ........................................56 (212) ........................................57 (213) ........................................57 (214) ........................................58 (215) ........................................58 (216) ........................................59 (217) ........................................59 (218) ........................................60 (219) ........................................60 (21A) ........................................60 (21B) ........................................61 (220) ........................................61 (221) ........................................61 (222) ........................................62 (223) ........................................62 (224) ........................................62 (225) ........................................62 (226) ........................................63 (227) ........................................63 (228) ........................................63 (229) ........................................64 (22B) ........................................64 (22C) ........................................64 (22D) .......................................64 (230) ........................................65

(231) .........................................65 (232) .........................................66 (233) .........................................66 (234) .........................................67 (235) .........................................67 (236) .........................................68 (237) .........................................68 (240) .........................................68 (241) .........................................68 (242) .........................................69 (243) .........................................70 (244) .........................................70 (245) .........................................71 (250) .........................................71 (251) .........................................71 (252) .........................................72 (253) .........................................72 (254) .........................................72 (255) .........................................73 (256) .........................................73 (257) .........................................73 (258) .........................................73 (259) .........................................73 (25A) ........................................74 (25B) ........................................74 (25C) ........................................74 (25D) ........................................74 (25E) ........................................74 (25F) ........................................75 (25G) ........................................75 (25H) .......................................75 (25I) .........................................75 (25J) .........................................76 (25K) ........................................76 (25L) ........................................76 (25M) .......................................76 (25N) .................................71, 76 (25O) .......................................76 (25Q) .......................................77 (25R) ........................................77 (25S) .........................................77 (25T) ........................................77 (25U) ........................................78 (260) .........................................78 (261) .........................................78 (262) .........................................78 (2621) .......................................78 (2622) .......................................79 (263) .........................................79 (2631) .......................................79 (2632) .......................................79 (2633) .......................................79 (2634) .......................................79 (264) .........................................80 (265) .........................................80 (269) .........................................81 (310) .........................................81 (320) .........................................82 (321) .........................................82 (322) .........................................83

(323) ........................................ 84 (324) ........................................ 85 (325) ........................................ 85 (326) ........................................ 85 (327) ........................................ 85 (328) ........................................ 86 (331) ........................................ 86 (332) ........................................ 87 (333) ........................................ 87 (334) ........................................ 87 (335) ........................................ 88 (336) ........................................ 88 (337) ........................................ 88 (338) ........................................ 89 (339) ........................................ 89 (33A) ....................................... 89 (33B) ........................................ 90 (33C) ....................................... 90 (33D) ....................................... 91 (33E) ........................................ 91 (33F) ........................................ 92 (33G) ....................................... 92 (33H1) ..................................... 92 (341) ........................................ 93 (342) ........................................ 93 (343) ........................................ 94 (344) ........................................ 94 (345) ........................................ 95 (346) ........................................ 95 (347) ........................................ 95 (348) ........................................ 95 (351) ........................................ 96 (354) ........................................ 97 (361) ........................................ 98 (362) ........................................ 98 (363) ........................................ 98 (364) ........................................ 98 (365) ........................................ 98 (366) ........................................ 98 (367) ........................................ 98 (368) ........................................ 98 (369) ........................................ 99 (371) ........................................ 99 (372) ...................................... 100 (373) ...................................... 100 (380) ...................................... 100 (381) ...................................... 100 (383) ...................................... 100 (384) ...................................... 101 (385) ...................................... 101 (386) ...................................... 101 (387) ...................................... 101 (388) ...................................... 102 (389) ...................................... 102 (391) ...................................... 104 (392) ...................................... 104 (393) ...................................... 104 (394) ...................................... 105 (395) ...................................... 105 (396) ...................................... 105

Manual — Menu and alphabetical index continuation — page 206

Manual reference: physical PDF page 206. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

(398) ......................................106 (399) ......................................106 (39A) ......................................107 (39B) ......................................107 (39C) ......................................107 (39D) .....................................107 (39E) ......................................108 (39F) ......................................108 (39G) .....................................109 (39H-39M) ............................109 (410) ......................................113 (411) ......................................113 (412) ......................................113 (413) ......................................114 (414) ......................................114 (415) ......................................114 (416) ......................................115 (4162) ....................................115 (417) ......................................115 (4171) ....................................115 (4172) ....................................115 (418) ......................................115 (4181) ....................................115 (4182) ....................................116 (419) ......................................116 (4191) ....................................116 (4192) ....................................116 (41A) ......................................116 (41B) ......................................117 (41C) ......................................117 (421) ......................................118 (422) ......................................118 (423) ......................................118 (424) ......................................119 (511) ......................................119 (512) ......................................120 (513) ......................................121 (514) ......................................124 (515) ......................................124 (516) ......................................124 (517) ......................................124 (518) ......................................125 (519) ......................................125 (51A) ......................................125 (51B) ......................................125 (51C) ......................................125 (521) ................................92, 126 (522) ......................................127 (529-52H) ..............................127 (531) ......................................128 (532) ......................................128 (533) ......................................129 (534) ......................................131 (535) ......................................131 (536) ......................................131 (541) ......................................132 (542) ......................................134 (551) ......................................134 (552) ......................................134 (553) ......................................134

(55D) ......................................135 (561) .......................................135 (562) .......................................136 (563-56G) ..............................136 (610) .......................................136 (6111) .....................................137 (6112) .....................................139 (6113) .....................................141 (6114) .....................................141 (6115) .....................................141 (6121) .....................................142 (6122) .....................................142 (6123) .....................................142 (6124) .....................................143 (6125) .....................................143 (6131) .....................................143 (6132) .....................................143 (6133) .....................................144 (6134) .....................................144 (6135) .....................................144 (6141) .....................................144 (6142) .....................................145 (6143) .....................................145 (6144) .....................................145 (6145) .....................................145 (6151) .....................................146 (6152) .....................................146 (6153) .....................................146 (6154) .....................................146 (620) .......................................147 (621) ...............................147, 148 (622) ...............................147, 148 (623) ...............................147, 148 (624) .......................................147 (625) .......................................147 (630) .......................................149 (631) .......................................149 (632) .......................................149 (633) .......................................150 (634) .......................................150 (635) .......................................150 (640) .......................................150 (641) .......................................150 (642) .......................................151 (643) .......................................151 (644) .......................................151 (645) .......................................151 (649) .......................................152 (650) .......................................152 (651) .......................................152 (652) .......................................152 (653) .......................................152 (654) .......................................152 (655) .......................................153 (659) .......................................153 (711) .......................................153 (712) .......................................153 (713) .......................................154 (714) .......................................154 (715) .......................................154

(716) ...................................... 154 (717) ...................................... 154 (718) ...................................... 155 (719) ...................................... 155 (71A) ..................................... 155 (71B) ...................................... 155 (720) ...................................... 156 (721) ...................................... 156 (722) ...................................... 156 (723) ...................................... 157 (724) ...................................... 157 (725) ...................................... 157 (726) ...................................... 158 (727) ...................................... 158 (728-72A) .............................. 158 (730) ...................................... 159 (731) ...................................... 159 (7311) .................................... 159 (732) ...................................... 159 (733) ...................................... 159 (7331) .................................... 160 (800) ...................................... 160 (810) ...................................... 160 (811-81N) .............................. 161 (820) ...................................... 161 (830) ...................................... 161 (8A0) ..................................... 162 (900) ...................................... 162 (920) ...................................... 162 (922) ...................................... 162 33F .......................................... 92 616 ........................................ 142 Minimum Frequency ...................... 88 Monitor function Alarm Select ........................... 117 Delay time ............................. 114 Max Alarm ............................. 113 Overload .......................... 41, 113 Response delay ............... 115, 117 Start delay .............................. 114 Motor cables .................................... 16 Motor cos phi (power factor) ........... 63 Motor data ...................................... 61 Motor frequency ............................. 62 Motor I2t Current ......................... 167 Motor identification run ................. 64 Motor Lost ...................................... 73 Motor lost ..................................... 118 Motor Potentiometer .............. 98, 126 Motor potentiometer ..................... 126 Motor ventilation ............................ 63 Motors .............................................. 5 Motors in parallel ............................ 21 MotPot ............................................ 87 N Nominal motor frequency ............... 94 Number of drives .......................... 104

Manual — Alphabetical index O through V — page 207

Manual reference: physical PDF page 207. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

O Operation ........................................56 Options ...................................28, 171 Brake chopper ........................172 External Control Panel (ECP) 171 I/O Board ...............................173 Output coils ...........................174 Protection class IP23 and IP54 ..... 171 Serial communication, fieldbus ..... 174 OR operator ..................................147 Output coils ..................................174 Output Voltage .............................154 Overload ..................................41, 113 Overload alarm ................................41 P Parameter sets Load default values ...................70 Load parameter sets from Control Panel ........................................71 Parameter Set Selection ............35 Select a Parameter set ................68 PI Autotune .....................................99 PID Controller ..............................100 Closed loop PID control .........101 Feedback signal .......................100 PID D Time ...........................101 PID I Time ............................101 PID P Gain ............................100 Power LED ......................................46 Priority ............................................36 Process Protection ..........................118 Process Value .................................153 Product standard, EMC .....................6 Programming ...................................49 Protection class IP23 and IP54 ......171 PT100 Inputs ..................................68 PTC input .......................................67 Pump/Fan Control ........................104 Q Quick Setup Card ..............................5 R Reference Frequency ...............................118 Motor potentiometer ..............126 Reference signal ..................57, 81 Set reference value ....................81 Torque ...................................118 View reference value .................81 Reference control .............................58 Reference signal ...............................58 Relay output ..................................134 Relay 1 ...................................134 Relay 2 ...................................134 Relay 3 ...................................134 Release speed ...................................91

Remote control ................................37 Reset command ..............................126 Reset control ....................................59 Resolution ........................................55 RFI mains filter ................................16 Rotation ...........................................60 RS232/485 .......................................78 RUN ................................................46 Run command .................................47 Run Left command ........................126 Run Right command .....................126 Running motor ................................89 S Select Drive ....................................104 Settle Time ....................................107 Setup menu ......................................49 Menu structure .........................48 Shaft power ....................................154 Signal ground .................................192 Single-ended connection ..................27 Software .........................................162 Speed .............................................153 Speed Mode .....................................57 Spinstart ...........................................89 Standards ...........................................6 Start Delay .....................................106 Start/Stop settings ............................86 Status indications .............................45 Stop categories .................................43 Stop command ...............................126 Stop Delay .....................................107 Stripping lengths ..............................20 Switches ...........................................24 Switching in motor cables ................18 T Technical Data ...............................179 Terminal connections ......................24 Test Run ..........................................64 Timer .............................................105 Torque .......................................55, 96 Transition Frequency .....................108 Trip .................................................46 Trip causes and remidial action ......166 Trip Message log ............................160 Trips, warnings and limits ..............165 Twisted cables ..................................28 Type code number .............................5 U Underload ........................................41 Underload alarm ............................113 Unlock Code ...................................60 Upper Band ...................................106 Menu (397) 106 Upper Band Limit ..........................107

V V/Hz Mode ..................................... 57 Vector Brake ................................... 92 Ventilation ...................................... 63 View reference value ........................ 81 Voltage ............................................ 24 VSD Data ..................................... 162

Manual — Back cover company contact and edition imprint — page 208

Manual reference: physical PDF page 208. Read the complete procedure and adjacent-page conditions in the original; model and firmware applicability must be confirmed.

TECO Electric & Machinery Co.,Ltd. 10F, No.3-1,Yuancyu St., Nangang District, Taipei City 115, Taiwan Tel: +886-2-6615-9111, Fax: +886-2-6615-0933 Internet: www.teco.com.tw Ver.03 2011.6

Technical source 001 — Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V

Source download: Datasheet4078.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 1 / 1 Constant Torque: 0.55 / 2; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4078.pdf
38 / 1 / 1 Constant Torque: 0.55 / 2; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4078.pdf

P037 / Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-003-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 0.55 as printed in field/value C1
General specification / Rated Output Current(A) 2 as printed in field/value C1
General specification / Maximum Output Current(A) 3.8 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-003-54/ 0.55KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 002 — Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V

Source download: Datasheet4079.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 2 / 2 Constant Torque: 0.75 / 1.6; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4079.pdf
38 / 2 / 2 Constant Torque: 0.75 / 1.6; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4079.pdf

P037 / Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-002-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 0.75 as printed in field/value C1
General specification / Rated Output Current(A) 1.6 as printed in field/value C1
General specification / Maximum Output Current(A) 3.2 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-002-54/ 0.75KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 003 — Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V

Source download: Datasheet4080.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 3 / 3 Constant Torque: 1.1 / 3.2; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4080.pdf
38 / 3 / 3 Constant Torque: 1.1 / 3.2; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4080.pdf

P037 / Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-004-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1.1 as printed in field/value C1
General specification / Rated Output Current(A) 3.2 as printed in field/value C1
General specification / Maximum Output Current(A) 6 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-004-54/ 1.1KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 004 — Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V

Source download: Datasheet4081.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 4 / 4 Constant Torque: 1.5 / 4.8; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4081.pdf
38 / 4 / 4 Constant Torque: 1.5 / 4.8; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4081.pdf

P037 / Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-006-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1.5 as printed in field/value C1
General specification / Rated Output Current(A) 4.8 as printed in field/value C1
General specification / Maximum Output Current(A) 9 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-006-54/ 1.5KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 005 — Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V

Source download: Datasheet4082.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 5 / 5 Constant Torque: 1.5 / 2.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4082.pdf
38 / 5 / 5 Constant Torque: 1.5 / 2.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4082.pdf

P037 / Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-003-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1.5 as printed in field/value C1
General specification / Rated Output Current(A) 2.4 as printed in field/value C1
General specification / Maximum Output Current(A) 4.8 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-003-54/ 1.5KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 006 — Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V

Source download: Datasheet4083.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 6 / 6 Constant Torque: 2.2 / 3.2; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4083.pdf
38 / 6 / 6 Constant Torque: 2.2 / 3.2; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4083.pdf

P037 / Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-004-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 2.2 as printed in field/value C1
General specification / Rated Output Current(A) 3.2 as printed in field/value C1
General specification / Maximum Output Current(A) 6.4 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-004-54/ 2.2KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 007 — Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V

Source download: Datasheet4084.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 7 / 7 Constant Torque: 2.2 / 6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4084.pdf
38 / 7 / 7 Constant Torque: 2.2 / 6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4084.pdf

P037 / Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-008-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 2.2 as printed in field/value C1
General specification / Rated Output Current(A) 6 as printed in field/value C1
General specification / Maximum Output Current(A) 11.3 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-008-54/ 2.2KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 008 — Variable speed drive VFX48-010-54/ 3KW/ 380-480V

Source download: Datasheet4085.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-010-54/ 3KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 8 / 8 Constant Torque: 3 / 7.6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4085.pdf
38 / 8 / 8 Constant Torque: 3 / 7.6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4085.pdf

P037 / Variable speed drive VFX48-010-54/ 3KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-010-54/ 3KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-010-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 3 as printed in field/value C1
General specification / Rated Output Current(A) 7.6 as printed in field/value C1
General specification / Maximum Output Current(A) 14.3 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-010-54/ 3KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-010-54/ 3KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-010-54/ 3KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 009 — Variable speed drive VFX69-006-54/ 3KW/ 400-690V

Source download: Datasheet4086.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-006-54/ 3KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 9 / 9 Constant Torque: 3 / 4.8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4086.pdf
38 / 9 / 9 Constant Torque: 3 / 4.8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4086.pdf

P037 / Variable speed drive VFX69-006-54/ 3KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-006-54/ 3KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-006-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 3 as printed in field/value C1
General specification / Rated Output Current(A) 4.8 as printed in field/value C1
General specification / Maximum Output Current(A) 9.6 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-006-54/ 3KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-006-54/ 3KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-006-54/ 3KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 010 — Variable speed drive VFX69-008-54/ 4KW/ 400-690V

Source download: Datasheet4087.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-008-54/ 4KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 10 / 10 Constant Torque: 4 / 6.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4087.pdf
38 / 10 / 10 Constant Torque: 4 / 6.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4087.pdf

P037 / Variable speed drive VFX69-008-54/ 4KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-008-54/ 4KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-008-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 4 as printed in field/value C1
General specification / Rated Output Current(A) 6.4 as printed in field/value C1
General specification / Maximum Output Current(A) 12.8 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-008-54/ 4KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-008-54/ 4KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-008-54/ 4KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 011 — Variable speed drive VFX48-013-54/ 4KW/ 380-480V

Source download: Datasheet4088.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-013-54/ 4KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 11 / 11 Constant Torque: 4 / 10.4; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4088.pdf
38 / 11 / 11 Constant Torque: 4 / 10.4; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4088.pdf

P037 / Variable speed drive VFX48-013-54/ 4KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-013-54/ 4KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-013-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 4 as printed in field/value C1
General specification / Rated Output Current(A) 10.4 as printed in field/value C1
General specification / Maximum Output Current(A) 19.5 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-013-54/ 4KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-013-54/ 4KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-013-54/ 4KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 012 — Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V

Source download: Datasheet4089.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 12 / 12 Constant Torque: 5.5 / 14.4; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4089.pdf
38 / 12 / 12 Constant Torque: 5.5 / 14.4; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4089.pdf

P037 / Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-018-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 5.5 as printed in field/value C1
General specification / Rated Output Current(A) 14.4 as printed in field/value C1
General specification / Maximum Output Current(A) 27 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-018-54/ 5.5KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 416x 230x 230 (mm). mm C3

Technical source 013 — Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V

Source download: Datasheet4090.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 13 / 13 Constant Torque: 5.5 / 8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4090.pdf
38 / 13 / 13 Constant Torque: 5.5 / 8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4090.pdf

P037 / Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-010-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 5.5 as printed in field/value C1
General specification / Rated Output Current(A) 8 as printed in field/value C1
General specification / Maximum Output Current(A) 16 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-010-54/ 5.5KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 014 — Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V

Source download: Datasheet4091.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 14 / 14 Constant Torque: 7.5 / 10.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4091.pdf
38 / 14 / 14 Constant Torque: 7.5 / 10.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4091.pdf

P037 / Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-013-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 7.5 as printed in field/value C1
General specification / Rated Output Current(A) 10.4 as printed in field/value C1
General specification / Maximum Output Current(A) 20.8 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-013-54/ 7.5KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 015 — Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V

Source download: Datasheet4092.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 15 / 15 Constant Torque: 7.5 / 21; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4092.pdf
38 / 15 / 15 Constant Torque: 7.5 / 21; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4092.pdf

P037 / Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-026-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 7.5 as printed in field/value C1
General specification / Rated Output Current(A) 21 as printed in field/value C1
General specification / Maximum Output Current(A) 39 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-026-54/ 7.5KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 292 (mm). mm C3

Technical source 016 — Variable speed drive VFX48-031-54/ 11KW/ 380-480V

Source download: Datasheet4093.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-031-54/ 11KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 16 / 16 Constant Torque: 11.0 / 25; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4093.pdf
38 / 16 / 16 Constant Torque: 11.0 / 25; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4093.pdf

P037 / Variable speed drive VFX48-031-54/ 11KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-031-54/ 11KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-031-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 11 as printed in field/value C1
General specification / Rated Output Current(A) 25 as printed in field/value C1
General specification / Maximum Output Current(A) 46 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-031-54/ 11KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-031-54/ 11KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-031-54/ 11KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 292 (mm). mm C3

Technical source 017 — Variable speed drive VFX69-018-54/ 11KW/ 400-690V

Source download: Datasheet4094.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-018-54/ 11KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 17 / 17 Constant Torque: 11 / 14.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4094.pdf
38 / 17 / 17 Constant Torque: 11 / 14.4; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4094.pdf

P037 / Variable speed drive VFX69-018-54/ 11KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-018-54/ 11KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-018-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 11 as printed in field/value C1
General specification / Rated Output Current(A) 14.4 as printed in field/value C1
General specification / Maximum Output Current(A) 29 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-018-54/ 11KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-018-54/ 11KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-018-54/ 11KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 018 — Variable speed drive VFX69-021-54/ 15KW/ 400-690V

Source download: Datasheet4095.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-021-54/ 15KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 18 / 18 Constant Torque: 15 / 16.8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4095.pdf
38 / 18 / 18 Constant Torque: 15 / 16.8; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4095.pdf

P037 / Variable speed drive VFX69-021-54/ 15KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-021-54/ 15KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-021-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 15 as printed in field/value C1
General specification / Rated Output Current(A) 16.8 as printed in field/value C1
General specification / Maximum Output Current(A) 34 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-021-54/ 15KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-021-54/ 15KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-021-54/ 15KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 019 — Variable speed drive VFX48-037-54/ 15KW/ 380-480V

Source download: Datasheet4096.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-037-54/ 15KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 19 / 19 Constant Torque: 15 / 29.6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4096.pdf
38 / 19 / 19 Constant Torque: 15 / 29.6; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4096.pdf

P037 / Variable speed drive VFX48-037-54/ 15KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-037-54/ 15KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-037-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 15 as printed in field/value C1
General specification / Rated Output Current(A) 29.6 as printed in field/value C1
General specification / Maximum Output Current(A) 55 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-037-54/ 15KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-037-54/ 15KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-037-54/ 15KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 292 (mm). mm C3

Technical source 020 — Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V

Source download: Datasheet4097.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 20 / 20 Constant Torque: 18.5 / 37; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4097.pdf
38 / 20 / 20 Constant Torque: 18.5 / 37; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4097.pdf

P037 / Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-046-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 18.5 as printed in field/value C1
General specification / Rated Output Current(A) 37 as printed in field/value C1
General specification / Maximum Output Current(A) 69 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-046-54/ 18.5KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 292 (mm). mm C3

Technical source 021 — Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V

Source download: Datasheet4098.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 21 / 21 Constant Torque: 18.5 / 20; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4098.pdf
38 / 21 / 21 Constant Torque: 18.5 / 20; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4098.pdf

P037 / Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-025-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 18.5 as printed in field/value C1
General specification / Rated Output Current(A) 20 as printed in field/value C1
General specification / Maximum Output Current(A) 40 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-025-54/ 18.5KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 512x 178x 314 (mm). mm C3

Technical source 022 — Variable speed drive VFX69-033-54/ 22KW/ 400-690V

Source download: Datasheet4099.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-033-54/ 22KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 22 / 22 Constant Torque: 22 / 26; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4099.pdf
38 / 22 / 22 Constant Torque: 22 / 26; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4099.pdf

P037 / Variable speed drive VFX69-033-54/ 22KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-033-54/ 22KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-033-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 22 as printed in field/value C1
General specification / Rated Output Current(A) 26 as printed in field/value C1
General specification / Maximum Output Current(A) 53 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-033-54/ 22KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-033-54/ 22KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-033-54/ 22KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 023 — Variable speed drive VFX48-061-54/ 22KW/ 380-480V

Source download: Datasheet4100.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-061-54/ 22KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 23 / 23 Constant Torque: 22 / 49; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4100.pdf
38 / 23 / 23 Constant Torque: 22 / 49; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4100.pdf

P037 / Variable speed drive VFX48-061-54/ 22KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-061-54/ 22KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-061-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 22 as printed in field/value C1
General specification / Rated Output Current(A) 49 as printed in field/value C1
General specification / Maximum Output Current(A) 92 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-061-54/ 22KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-061-54/ 22KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-061-54/ 22KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 024 — Variable speed drive VFX48-074-54/ 30KW/ 380-480V

Source download: Datasheet4101.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-074-54/ 30KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 24 / 24 Constant Torque: 30 / 59; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4101.pdf
38 / 24 / 24 Constant Torque: 30 / 59; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4101.pdf

P037 / Variable speed drive VFX48-074-54/ 30KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-074-54/ 30KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-074-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 30 as printed in field/value C1
General specification / Rated Output Current(A) 59 as printed in field/value C1
General specification / Maximum Output Current(A) 111 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-074-54/ 30KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-074-54/ 30KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-074-54/ 30KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 025 — Variable speed drive VFX69-042-54/ 30KW/ 400-690V

Source download: Datasheet4102.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-042-54/ 30KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 25 / 25 Constant Torque: 30 / 34; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4102.pdf
38 / 25 / 25 Constant Torque: 30 / 34; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4102.pdf

P037 / Variable speed drive VFX69-042-54/ 30KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-042-54/ 30KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-042-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 30 as printed in field/value C1
General specification / Rated Output Current(A) 34 as printed in field/value C1
General specification / Maximum Output Current(A) 67 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-042-54/ 30KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-042-54/ 30KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-042-54/ 30KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 026 — Variable speed drive VFX69-050-54/ 37KW/ 400-690V

Source download: Datasheet4103.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-050-54/ 37KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 26 / 26 Constant Torque: 37 / 40; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4103.pdf
38 / 26 / 26 Constant Torque: 37 / 40; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4103.pdf

P037 / Variable speed drive VFX69-050-54/ 37KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-050-54/ 37KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-050-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 37 as printed in field/value C1
General specification / Rated Output Current(A) 40 as printed in field/value C1
General specification / Maximum Output Current(A) 80 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-050-54/ 37KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-050-54/ 37KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-050-54/ 37KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 027 — Variable speed drive VFX48-090-54/ 37KW/ 380-480V

Source download: Datasheet4104.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-090-54/ 37KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 27 / 27 Constant Torque: 37 / 72; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4104.pdf
38 / 27 / 27 Constant Torque: 37 / 72; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4104.pdf

P037 / Variable speed drive VFX48-090-54/ 37KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-090-54/ 37KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-090-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 37 as printed in field/value C1
General specification / Rated Output Current(A) 72 as printed in field/value C1
General specification / Maximum Output Current(A) 108 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-090-54/ 37KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-090-54/ 37KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-090-54/ 37KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 285x 314 (mm). mm C3

Technical source 028 — Variable speed drive VFX48-109-54/ 45KW/ 380-480V

Source download: Datasheet4105.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-109-54/ 45KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 28 / 28 Constant Torque: 45 / 87; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4105.pdf
38 / 28 / 28 Constant Torque: 45 / 87; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4105.pdf

P037 / Variable speed drive VFX48-109-54/ 45KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-109-54/ 45KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-109-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 45 as printed in field/value C1
General specification / Rated Output Current(A) 87 as printed in field/value C1
General specification / Maximum Output Current(A) 131 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-109-54/ 45KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-109-54/ 45KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-109-54/ 45KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 285x 314 (mm). mm C3

Technical source 029 — Variable speed drive VFX69-058-54/ 45KW/ 400-690V

Source download: Datasheet4106.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-058-54/ 45KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 29 / 29 Constant Torque: 45 / 46; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4106.pdf
38 / 29 / 29 Constant Torque: 45 / 46; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4106.pdf

P037 / Variable speed drive VFX69-058-54/ 45KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-058-54/ 45KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-058-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 45 as printed in field/value C1
General specification / Rated Output Current(A) 46 as printed in field/value C1
General specification / Maximum Output Current(A) 93 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-058-54/ 45KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-058-54/ 45KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-058-54/ 45KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 590x 220x 295 (mm). mm C3

Technical source 030 — Variable speed drive VFX69-082-54/ 55KW/ 400-690V

Source download: Datasheet4107.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-082-54/ 55KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 30 / 30 Constant Torque: 55 / 66; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4107.pdf
38 / 30 / 30 Constant Torque: 55 / 66; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4107.pdf

P037 / Variable speed drive VFX69-082-54/ 55KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-082-54/ 55KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-082-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 55 as printed in field/value C1
General specification / Rated Output Current(A) 66 as printed in field/value C1
General specification / Maximum Output Current(A) 98 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-082-54/ 55KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-082-54/ 55KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-082-54/ 55KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 031 — Variable speed drive VFX48-146-54/ 55KW/ 380-480V

Source download: Datasheet4108.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-146-54/ 55KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 31 / 31 Constant Torque: 55 / 117; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4108.pdf
38 / 31 / 31 Constant Torque: 55 / 117; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4108.pdf

P037 / Variable speed drive VFX48-146-54/ 55KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-146-54/ 55KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-146-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 55 as printed in field/value C1
General specification / Rated Output Current(A) 117 as printed in field/value C1
General specification / Maximum Output Current(A) 175 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-146-54/ 55KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-146-54/ 55KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-146-54/ 55KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 285x 314 (mm). mm C3

Technical source 032 — Variable speed drive VFX48-175-54/ 75KW/ 380-480V

Source download: Datasheet4109.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-175-54/ 75KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 32 / 32 Constant Torque: 75 / 140; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4109.pdf
38 / 32 / 32 Constant Torque: 75 / 140; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4109.pdf

P037 / Variable speed drive VFX48-175-54/ 75KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-175-54/ 75KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-175-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 75 as printed in field/value C1
General specification / Rated Output Current(A) 140 as printed in field/value C1
General specification / Maximum Output Current(A) 210 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-175-54/ 75KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-175-54/ 75KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-175-54/ 75KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 285x 314 (mm). mm C3

Technical source 033 — Variable speed drive VFX69-090-54/ 75KW/ 400-690V

Source download: Datasheet4110.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-090-54/ 75KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 33 / 33 Constant Torque: 75 / 72; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4110.pdf
38 / 33 / 33 Constant Torque: 75 / 72; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4110.pdf

P037 / Variable speed drive VFX69-090-54/ 75KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-090-54/ 75KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-090-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 75 as printed in field/value C1
General specification / Rated Output Current(A) 72 as printed in field/value C1
General specification / Maximum Output Current(A) 108 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-090-54/ 75KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-090-54/ 75KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-090-54/ 75KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 034 — Variable speed drive VFX69-109-54/ 90KW/ 400-690V

Source download: Datasheet4111.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-109-54/ 90KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 34 / 34 Constant Torque: 90 / 87; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4111.pdf
38 / 34 / 34 Constant Torque: 90 / 87; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4111.pdf

P037 / Variable speed drive VFX69-109-54/ 90KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-109-54/ 90KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-109-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 90 as printed in field/value C1
General specification / Rated Output Current(A) 87 as printed in field/value C1
General specification / Maximum Output Current(A) 131 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-109-54/ 90KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-109-54/ 90KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-109-54/ 90KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 035 — Variable speed drive VFX48-210-54/ 90KW/ 380-480V

Source download: Datasheet4112.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-210-54/ 90KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 35 / 35 Constant Torque: 90 / 168; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4112.pdf
38 / 35 / 35 Constant Torque: 90 / 168; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4112.pdf

P037 / Variable speed drive VFX48-210-54/ 90KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-210-54/ 90KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-210-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 90 as printed in field/value C1
General specification / Rated Output Current(A) 168 as printed in field/value C1
General specification / Maximum Output Current(A) 252 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-210-54/ 90KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-210-54/ 90KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-210-54/ 90KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 345x 314 (mm). mm C3

Technical source 036 — Variable speed drive VFX48-250-54/ 110KW/ 380-480V

Source download: Datasheet4113.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-250-54/ 110KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 36 / 36 Constant Torque: 110 / 200; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4113.pdf
38 / 36 / 36 Constant Torque: 110 / 200; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4113.pdf

P037 / Variable speed drive VFX48-250-54/ 110KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-250-54/ 110KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-250-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 110 as printed in field/value C1
General specification / Rated Output Current(A) 200 as printed in field/value C1
General specification / Maximum Output Current(A) 300 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-250-54/ 110KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-250-54/ 110KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-250-54/ 110KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 345x 314 (mm). mm C3

Technical source 037 — Variable speed drive VFX69-146-54/ 110KW/ 400-690V

Source download: Datasheet4114.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-146-54/ 110KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 37 / 37 Constant Torque: 110 / 117; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4114.pdf
38 / 37 / 37 Constant Torque: 110 / 117; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4114.pdf

P037 / Variable speed drive VFX69-146-54/ 110KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-146-54/ 110KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-146-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 110 as printed in field/value C1
General specification / Rated Output Current(A) 117 as printed in field/value C1
General specification / Maximum Output Current(A) 175 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-146-54/ 110KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-146-54/ 110KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-146-54/ 110KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 038 — Variable speed drive VFX69-175-54/ 132KW/ 400-690V

Source download: Datasheet4115.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-175-54/ 132KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 38 / 38 Constant Torque: 132 / 140; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4115.pdf
38 / 38 / 38 Constant Torque: 132 / 140; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4115.pdf

P037 / Variable speed drive VFX69-175-54/ 132KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-175-54/ 132KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-175-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 132 as printed in field/value C1
General specification / Rated Output Current(A) 140 as printed in field/value C1
General specification / Maximum Output Current(A) 210 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-175-54/ 132KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-175-54/ 132KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-175-54/ 132KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 039 — Variable speed drive VFX48-295-54/ 132KW/ 380-480V

Source download: Datasheet4116.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-295-54/ 132KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 39 / 39 Constant Torque: 132 / 236; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4116.pdf
38 / 39 / 39 Constant Torque: 132 / 236; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4116.pdf

P037 / Variable speed drive VFX48-295-54/ 132KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-295-54/ 132KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-295-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 132 as printed in field/value C1
General specification / Rated Output Current(A) 236 as printed in field/value C1
General specification / Maximum Output Current(A) 354 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-295-54/ 132KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-295-54/ 132KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-295-54/ 132KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 950x 345x 314 (mm). mm C3

Technical source 040 — Variable speed drive VFX48-365-54/ 160KW/ 380-480V

Source download: Datasheet4117.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-365-54/ 160KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 40 / 40 Constant Torque: 160 / 292; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4117.pdf
38 / 40 / 40 Constant Torque: 160 / 292; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4117.pdf

P037 / Variable speed drive VFX48-365-54/ 160KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-365-54/ 160KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-365-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 160 as printed in field/value C1
General specification / Rated Output Current(A) 292 as printed in field/value C1
General specification / Maximum Output Current(A) 438 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-365-54/ 160KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-365-54/ 160KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-365-54/ 160KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1395x 345x 365 (mm). mm C3

Technical source 041 — Variable speed drive VFX69-200-54/ 160KW/ 400-690V

Source download: Datasheet4118.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-200-54/ 160KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 41 / 41 Constant Torque: 160 / 160; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4118.pdf
38 / 41 / 41 Constant Torque: 160 / 160; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4118.pdf

P037 / Variable speed drive VFX69-200-54/ 160KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-200-54/ 160KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-200-54 as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 160 as printed in field/value C1
General specification / Rated Output Current(A) 160 as printed in field/value C1
General specification / Maximum Output Current(A) 240 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-200-54/ 160KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-200-54/ 160KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-200-54/ 160KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 1090x 345x 314 (mm). mm C3

Technical source 042 — Variable speed drive VFX69-250-IP/ 200KW/ 400-690V

Source download: Datasheet4119.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-250-IP/ 200KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 42 / 42 Constant Torque: 200 / 200; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4119.pdf
38 / 42 / 42 Constant Torque: 200 / 200; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4119.pdf

P037 / Variable speed drive VFX69-250-IP/ 200KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-250-IP/ 200KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-250-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 200 as printed in field/value C1
General specification / Rated Output Current(A) 200 as printed in field/value C1
General specification / Maximum Output Current(A) 300 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-250-IP/ 200KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-250-IP/ 200KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-250-IP/ 200KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 043 — Variable speed drive VFX48-430-IP/ 200KW/ 380-480V

Source download: Datasheet4120.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-430-IP/ 200KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 43 / 43 Constant Torque: 200 / 344; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4120.pdf
38 / 43 / 43 Constant Torque: 200 / 344; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4120.pdf

P037 / Variable speed drive VFX48-430-IP/ 200KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-430-IP/ 200KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-430-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 200 as printed in field/value C1
General specification / Rated Output Current(A) 344 as printed in field/value C1
General specification / Maximum Output Current(A) 516 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-430-IP/ 200KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-430-IP/ 200KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-430-IP/ 200KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 044 — Variable speed drive VFX48-500-IP/ 220KW/ 380-480V

Source download: Datasheet4121.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-500-IP/ 220KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 44 / 44 Constant Torque: 220 / 400; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4121.pdf
38 / 44 / 44 Constant Torque: 220 / 400; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4121.pdf

P037 / Variable speed drive VFX48-500-IP/ 220KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-500-IP/ 220KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-500-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 220 as printed in field/value C1
General specification / Rated Output Current(A) 400 as printed in field/value C1
General specification / Maximum Output Current(A) 600 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-500-IP/ 220KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-500-IP/ 220KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-500-IP/ 220KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 045 — Variable speed drive VFX48-600-IP/ 250KW/ 380-480V

Source download: Datasheet4122.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-600-IP/ 250KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 45 / 45 Constant Torque: 250 / 480; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4122.pdf
38 / 45 / 45 Constant Torque: 250 / 480; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4122.pdf

P037 / Variable speed drive VFX48-600-IP/ 250KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-600-IP/ 250KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-600-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 250 as printed in field/value C1
General specification / Rated Output Current(A) 480 as printed in field/value C1
General specification / Maximum Output Current(A) 720 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-600-IP/ 250KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-600-IP/ 250KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-600-IP/ 250KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 046 — Variable speed drive VFX69-300-IP/ 250KW/ 400-690V

Source download: Datasheet4123.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-300-IP/ 250KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 46 / 46 Constant Torque: 250 / 240; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4123.pdf
38 / 46 / 46 Constant Torque: 250 / 240; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4123.pdf

P037 / Variable speed drive VFX69-300-IP/ 250KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-300-IP/ 250KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-300-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 250 as printed in field/value C1
General specification / Rated Output Current(A) 240 as printed in field/value C1
General specification / Maximum Output Current(A) 360 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-300-IP/ 250KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-300-IP/ 250KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-300-IP/ 250KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 047 — Variable speed drive VFX69-375-IP/ 315KW/ 400-690V

Source download: Datasheet4124.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-375-IP/ 315KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 47 / 47 Constant Torque: 315 / 300; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4124.pdf
38 / 47 / 47 Constant Torque: 315 / 300; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4124.pdf

P037 / Variable speed drive VFX69-375-IP/ 315KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-375-IP/ 315KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-375-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 315 as printed in field/value C1
General specification / Rated Output Current(A) 300 as printed in field/value C1
General specification / Maximum Output Current(A) 450 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-375-IP/ 315KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-375-IP/ 315KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-375-IP/ 315KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 048 — Variable speed drive VFX69-400-IP/ 315KW/ 400-690V

Source download: Datasheet4125.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-400-IP/ 315KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 48 / 48 Constant Torque: 315 / 320; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4125.pdf
38 / 48 / 48 Constant Torque: 315 / 320; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4125.pdf

P037 / Variable speed drive VFX69-400-IP/ 315KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-400-IP/ 315KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-400-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 315 as printed in field/value C1
General specification / Rated Output Current(A) 320 as printed in field/value C1
General specification / Maximum Output Current(A) 480 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-400-IP/ 315KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-400-IP/ 315KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-400-IP/ 315KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 600x 600 (mm). mm C3

Technical source 049 — Variable speed drive VFX69-430-IP/ 315KW/ 400-690V

Source download: Datasheet4126.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-430-IP/ 315KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 49 / 49 Constant Torque: 315 / 344; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4126.pdf
38 / 49 / 49 Constant Torque: 315 / 344; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4126.pdf

P037 / Variable speed drive VFX69-430-IP/ 315KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-430-IP/ 315KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-430-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 315 as printed in field/value C1
General specification / Rated Output Current(A) 344 as printed in field/value C1
General specification / Maximum Output Current(A) 516 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-430-IP/ 315KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-430-IP/ 315KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-430-IP/ 315KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 050 — Variable speed drive VFX48-650-IP/ 315KW/ 380-480V

Source download: Datasheet4127.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-650-IP/ 315KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 50 / 50 Constant Torque: 315 / 520; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4127.pdf
38 / 50 / 50 Constant Torque: 315 / 520; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4127.pdf

P037 / Variable speed drive VFX48-650-IP/ 315KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-650-IP/ 315KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-650-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 315 as printed in field/value C1
General specification / Rated Output Current(A) 520 as printed in field/value C1
General specification / Maximum Output Current(A) 780 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-650-IP/ 315KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-650-IP/ 315KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-650-IP/ 315KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 051 — Variable speed drive VFX48-750-IP/ 355KW/ 380-480V

Source download: Datasheet4128.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-750-IP/ 355KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 51 / 51 Constant Torque: 355 / 600; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4128.pdf
38 / 51 / 51 Constant Torque: 355 / 600; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4128.pdf

P037 / Variable speed drive VFX48-750-IP/ 355KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-750-IP/ 355KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-750-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 355 as printed in field/value C1
General specification / Rated Output Current(A) 600 as printed in field/value C1
General specification / Maximum Output Current(A) 900 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-750-IP/ 355KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-750-IP/ 355KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-750-IP/ 355KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 052 — Variable speed drive VFX69-500-IP/ 355KW/ 400-690V

Source download: Datasheet4129.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-500-IP/ 355KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 52 / 52 Constant Torque: 355 / 400; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4129.pdf
38 / 52 / 52 Constant Torque: 355 / 400; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4129.pdf

P037 / Variable speed drive VFX69-500-IP/ 355KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-500-IP/ 355KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-500-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 355 as printed in field/value C1
General specification / Rated Output Current(A) 400 as printed in field/value C1
General specification / Maximum Output Current(A) 600 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-500-IP/ 355KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-500-IP/ 355KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-500-IP/ 355KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 053 — Variable speed drive VFX48-860-IP/ 400KW/ 380-480V

Source download: Datasheet4130.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-860-IP/ 400KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 53 / 53 Constant Torque: 400 / 688; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4130.pdf
38 / 53 / 53 Constant Torque: 400 / 688; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4130.pdf

P037 / Variable speed drive VFX48-860-IP/ 400KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-860-IP/ 400KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-860-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 400 as printed in field/value C1
General specification / Rated Output Current(A) 688 as printed in field/value C1
General specification / Maximum Output Current(A) 1032 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-860-IP/ 400KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-860-IP/ 400KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-860-IP/ 400KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1200x 600 (mm). mm C3

Technical source 054 — Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V

Source download: Datasheet4131.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 54 / 54 Constant Torque: 450 / 800; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4131.pdf
38 / 54 / 54 Constant Torque: 450 / 800; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4131.pdf

P037 / Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K0-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 450 as printed in field/value C1
General specification / Rated Output Current(A) 800 as printed in field/value C1
General specification / Maximum Output Current(A) 1200 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K0-IP/ 450KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1200x 600 (mm). mm C3

Technical source 055 — Variable speed drive VFX69-595-IP/ 450KW/ 400-690V

Source download: Datasheet4132.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-595-IP/ 450KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 55 / 55 Constant Torque: 450 / 480; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4132.pdf
38 / 55 / 55 Constant Torque: 450 / 480; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4132.pdf

P037 / Variable speed drive VFX69-595-IP/ 450KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-595-IP/ 450KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-595-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 450 as printed in field/value C1
General specification / Rated Output Current(A) 480 as printed in field/value C1
General specification / Maximum Output Current(A) 720 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-595-IP/ 450KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-595-IP/ 450KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-595-IP/ 450KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 900x 600 (mm). mm C3

Technical source 056 — Variable speed drive VFX69-650-IP/ 500KW/ 400-690V

Source download: Datasheet4133.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-650-IP/ 500KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 56 / 56 Constant Torque: 500 / 520; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4133.pdf
38 / 56 / 56 Constant Torque: 500 / 520; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4133.pdf

P037 / Variable speed drive VFX69-650-IP/ 500KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-650-IP/ 500KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-650-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 500 as printed in field/value C1
General specification / Rated Output Current(A) 520 as printed in field/value C1
General specification / Maximum Output Current(A) 780 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-650-IP/ 500KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-650-IP/ 500KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-650-IP/ 500KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1200x 600 (mm). mm C3

Technical source 057 — Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V

Source download: Datasheet4134.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 57 / 57 Constant Torque: 500 / 920; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4134.pdf
38 / 57 / 57 Constant Torque: 500 / 920; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4134.pdf

P037 / Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K15-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 500 as printed in field/value C1
General specification / Rated Output Current(A) 920 as printed in field/value C1
General specification / Maximum Output Current(A) 1380 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K15-IP/ 500KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1500x 600 (mm). mm C3

Technical source 058 — Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V

Source download: Datasheet4135.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 58 / 58 Constant Torque: 560 / 1000; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4135.pdf
38 / 58 / 58 Constant Torque: 560 / 1000; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4135.pdf

P037 / Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K25-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 560 as printed in field/value C1
General specification / Rated Output Current(A) 1000 as printed in field/value C1
General specification / Maximum Output Current(A) 1500 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K25-IP/ 560KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1500x 600 (mm). mm C3

Technical source 059 — Variable speed drive VFX69-720-IP/ 560KW/ 400-690V

Source download: Datasheet4136.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-720-IP/ 560KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 59 / 59 Constant Torque: 560 / 576; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4136.pdf
38 / 59 / 59 Constant Torque: 560 / 576; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4136.pdf

P037 / Variable speed drive VFX69-720-IP/ 560KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-720-IP/ 560KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-720-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 560 as printed in field/value C1
General specification / Rated Output Current(A) 576 as printed in field/value C1
General specification / Maximum Output Current(A) 864 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-720-IP/ 560KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-720-IP/ 560KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-720-IP/ 560KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1200x 600 (mm). mm C3

Technical source 060 — Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V

Source download: Datasheet4137.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 60 / 60 Constant Torque: 600 / 1080; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4137.pdf
38 / 60 / 60 Constant Torque: 600 / 1080; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4137.pdf

P037 / Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K35-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 600 as printed in field/value C1
General specification / Rated Output Current(A) 1080 as printed in field/value C1
General specification / Maximum Output Current(A) 1620 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K35-IP/ 600KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1800x 600 (mm). mm C3

Technical source 061 — Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V

Source download: Datasheet4138.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 61 / 61 Constant Torque: 630 / 1200; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4138.pdf
38 / 61 / 61 Constant Torque: 630 / 1200; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4138.pdf

P037 / Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K5-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 630 as printed in field/value C1
General specification / Rated Output Current(A) 1200 as printed in field/value C1
General specification / Maximum Output Current(A) 1800 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K5-IP/ 630KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1800x 600 (mm). mm C3

Technical source 062 — Variable speed drive VFX69-800-IP/ 630KW/ 400-690V

Source download: Datasheet4139.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-800-IP/ 630KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 62 / 62 Constant Torque: 630 / 640; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4139.pdf
38 / 62 / 62 Constant Torque: 630 / 640; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4139.pdf

P037 / Variable speed drive VFX69-800-IP/ 630KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-800-IP/ 630KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-800-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 630 as printed in field/value C1
General specification / Rated Output Current(A) 640 as printed in field/value C1
General specification / Maximum Output Current(A) 960 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-800-IP/ 630KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-800-IP/ 630KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-800-IP/ 630KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1200x 600 (mm). mm C3

Technical source 063 — Variable speed drive VFX69-905-IP/ 710KW/ 400-690V

Source download: Datasheet4140.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-905-IP/ 710KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 63 / 63 Constant Torque: 710 / 720; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4140.pdf
38 / 63 / 63 Constant Torque: 710 / 720; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4140.pdf

P037 / Variable speed drive VFX69-905-IP/ 710KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-905-IP/ 710KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-905-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 710 as printed in field/value C1
General specification / Rated Output Current(A) 720 as printed in field/value C1
General specification / Maximum Output Current(A) 1080 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-905-IP/ 710KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-905-IP/ 710KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-905-IP/ 710KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1500x 600 (mm). mm C3

Technical source 064 — Variable speed drive VFX69-995-IP/ 800KW/ 400-690V

Source download: Datasheet4141.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-995-IP/ 800KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 64 / 64 Constant Torque: 800 / 800; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4141.pdf
38 / 64 / 64 Constant Torque: 800 / 800; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4141.pdf

P037 / Variable speed drive VFX69-995-IP/ 800KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-995-IP/ 800KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-995-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 800 as printed in field/value C1
General specification / Rated Output Current(A) 800 as printed in field/value C1
General specification / Maximum Output Current(A) 1200 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-995-IP/ 800KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-995-IP/ 800KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-995-IP/ 800KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1500x 600 (mm). mm C3

Technical source 065 — Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V

Source download: Datasheet4142.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 65 / 65 Constant Torque: 800 / 1400; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4142.pdf
38 / 65 / 65 Constant Torque: 800 / 1400; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4142.pdf

P037 / Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-1K75-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 800 as printed in field/value C1
General specification / Rated Output Current(A) 1400 as printed in field/value C1
General specification / Maximum Output Current(A) 2100 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-1K75-IP/ 800KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2100x 600 (mm). mm C3

Technical source 066 — Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V

Source download: Datasheet4143.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 66 / 66 Constant Torque: 900 / 1600; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4143.pdf
38 / 66 / 66 Constant Torque: 900 / 1600; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4143.pdf

P037 / Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-2K0-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 900 as printed in field/value C1
General specification / Rated Output Current(A) 1600 as printed in field/value C1
General specification / Maximum Output Current(A) 2400 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-2K0-IP/ 900KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2400x 600 (mm). mm C3

Technical source 067 — Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V

Source download: Datasheet4144.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 67 / 67 Constant Torque: 900 / 960; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4144.pdf
38 / 67 / 67 Constant Torque: 900 / 960; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4144.pdf

P037 / Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-1K2-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 900 as printed in field/value C1
General specification / Rated Output Current(A) 960 as printed in field/value C1
General specification / Maximum Output Current(A) 1440 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-1K2-IP/ 900KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 1800x 600 (mm). mm C3

Technical source 068 — Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V

Source download: Datasheet4145.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 68 / 68 Constant Torque: 1000 / 1800; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4145.pdf
38 / 68 / 68 Constant Torque: 1000 / 1800; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4145.pdf

P037 / Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-2K25-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1000 as printed in field/value C1
General specification / Rated Output Current(A) 1800 as printed in field/value C1
General specification / Maximum Output Current(A) 2700 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-2K25-IP/ 1000KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2700x 600 (mm). mm C3

Technical source 069 — Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V

Source download: Datasheet4146.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 69 / 69 Constant Torque: 1120 / 2000; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4146.pdf
38 / 69 / 69 Constant Torque: 1120 / 2000; Supply: 380-480V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4146.pdf

P037 / Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V as printed in field/value C1
General specification / Component name VFX48-2K5-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1120 as printed in field/value C1
General specification / Rated Output Current(A) 2000 as printed in field/value C1
General specification / Maximum Output Current(A) 3000 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 230~ 480V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX48-2K5-IP/ 1120KW/ 380-480V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 3000x 600 (mm). mm C3

Technical source 070 — Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V

Source download: Datasheet4147.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 70 / 70 Constant Torque: 1120 / 1120; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4147.pdf
38 / 70 / 70 Constant Torque: 1120 / 1120; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4147.pdf

P037 / Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-1K4-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1120 as printed in field/value C1
General specification / Rated Output Current(A) 1120 as printed in field/value C1
General specification / Maximum Output Current(A) 1680 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-1K4-IP/ 1120KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2100x 600 (mm). mm C3

Technical source 071 — Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V

Source download: Datasheet4148.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 71 / 71 Constant Torque: 1250 / 1280; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4148.pdf
38 / 71 / 71 Constant Torque: 1250 / 1280; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4148.pdf

P037 / Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-1K6-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1250 as printed in field/value C1
General specification / Rated Output Current(A) 1280 as printed in field/value C1
General specification / Maximum Output Current(A) 1920 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-1K6-IP/ 1250KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2400x 600 (mm). mm C3

Technical source 072 — Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V

Source download: Datasheet4149.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 72 / 72 Constant Torque: 1400 / 1440; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4149.pdf
38 / 72 / 72 Constant Torque: 1400 / 1440; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4149.pdf

P037 / Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-1K8-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1400 as printed in field/value C1
General specification / Rated Output Current(A) 1440 as printed in field/value C1
General specification / Maximum Output Current(A) 2160 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-1K8-IP/ 1400KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 2700x 600 (mm). mm C3

Technical source 073 — Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V

Source download: Datasheet4150.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 73 / 73 Constant Torque: 1600 / 1600; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4150.pdf
38 / 73 / 73 Constant Torque: 1600 / 1600; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4150.pdf

P037 / Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-2K0-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1600 as printed in field/value C1
General specification / Rated Output Current(A) 1600 as printed in field/value C1
General specification / Maximum Output Current(A) 2400 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-2K0-IP/ 1600KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 3000x 600 (mm). mm C3

Technical source 074 — Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V

Source download: Datasheet4151.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 74 / 74 Constant Torque: 1700 / 1760; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4151.pdf
38 / 74 / 74 Constant Torque: 1700 / 1760; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4151.pdf

P037 / Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-2K2-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1700 as printed in field/value C1
General specification / Rated Output Current(A) 1760 as printed in field/value C1
General specification / Maximum Output Current(A) 2640 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-2K2-IP/ 1700KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 3300x 600 (mm). mm C3

Technical source 075 — Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V

Source download: Datasheet4152.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 75 / 75 Constant Torque: 1900 / 1920; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4152.pdf
38 / 75 / 75 Constant Torque: 1900 / 1920; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4152.pdf

P037 / Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-2K4-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 1900 as printed in field/value C1
General specification / Rated Output Current(A) 1920 as printed in field/value C1
General specification / Maximum Output Current(A) 2880 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-2K4-IP/ 1900KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 3600x 600 (mm). mm C3

Technical source 076 — Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V

Source download: Datasheet4153.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 76 / 76 Constant Torque: 2000 / 2080; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4153.pdf
38 / 76 / 76 Constant Torque: 2000 / 2080; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4153.pdf

P037 / Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-2K6-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 2000 as printed in field/value C1
General specification / Rated Output Current(A) 2080 as printed in field/value C1
General specification / Maximum Output Current(A) 3120 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-2K6-IP/ 2000KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 3900x 600 (mm). mm C3

Technical source 077 — Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V

Source download: Datasheet4154.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 77 / 77 Constant Torque: 2200 / 2240; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4154.pdf
38 / 77 / 77 Constant Torque: 2200 / 2240; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4154.pdf

P037 / Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-2K8-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 2200 as printed in field/value C1
General specification / Rated Output Current(A) 2240 as printed in field/value C1
General specification / Maximum Output Current(A) 3360 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-2K8-IP/ 2200KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 4200x 600 (mm). mm C3

Technical source 078 — Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V

Source download: Datasheet4155.pdf.

Source differences and limitations

Conditions for this section:

Printed section / Main features — P037, Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V, page 1

Conditions for this section:

• NEW - Control panel with Real time clock. Optional Bluetooth communication.
• Available as robust and certified IP54 metal construction or IP20/21 version.
• All drive sizes are delivered with a built-in Category C3 EMC-filter as standard. C3 requirements
are fulfilled with 80 m motor cable (IP2Y= 25m).
• Direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load
changes.
• Load monitor function included as standard.
• UL (UL 840) approved version available (not IP2Y).
• Marine (DNV-GL & BV) approved version available (not IP2Y, IP2x).
• Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.
• Built-in brake chopper is standard for IP2Y models and available as option for all other.
• Temp / Speed controlled fans assures less noise, a more even drive temperature and higher drive
efficiency.
• Detachable multi-language control panel included as standard. Following languages are
supported in the control panel:
English, Swedish, Dutch, German, French, Spanish, Russian, Italian, Czech, Turkish and Polish.
• Operation parameters can be set in your process units, for example m/sec, tons/h or cycles/min.
• Removable control panel with own memory means it is easy to transfer or copy settings.
• Liquid cooled version available for sizes above 90 A.

Conditions for this section:

Conditions for this section:

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

No additional scalar specification fields are represented for this page. Refer to the source page for its graphical or other content; no geometry or additional rating is inferred.

Conditions for this section:

Website associations for this source

Table / row / row ID Listed specification Document role / member
13 / 78 / 78 Constant Torque: 2400 / 2400; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4155.pdf
38 / 78 / 78 Constant Torque: 2400 / 2400; Supply: 400-690V 3PH; IP Rating: 54 Drawing/Datasheet PDF / Datasheet4155.pdf

P037 / Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V — source page 1 — PDF page 1

Specification Value Unit / basis Conditions
Source heading Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V as printed in field/value C1
General specification / Component name VFX69-3K0-IP as printed in field/value C2
General specification / Suitable Motor Capacity Capacity(KW) 2400 as printed in field/value C1
General specification / Rated Output Current(A) 2400 as printed in field/value C1
General specification / Maximum Output Current(A) 3600 as printed in field/value C1
General specification / Input Voltage Range(V) Three-phase 400~ 690V, 50/60Hz as printed in field/value C1
General specification / Allowable Voltage Fluctuation -15%~ +10% as printed in field/value C1
General specification / Output Voltage range(V) Three-phase 0~480V as printed in field/value C1
General specification / Mains Frequency (Hz) 45 to 65 as printed in field/value C1
General specification / Output Switching Frequency (kHz) 3 as printed in field/value C1
General specification / Input Power Factor (%) 0.95 as printed in field/value C3
Environmental conditions / Nominal ambient temperature 0°C - 40°C (32°F- 104°F) as printed in field/value C1
Environmental conditions / Atmospheric pressure 86–106 kPa ( 12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Relative humidity according to IEC 60721-3-3 Class 3K4, 5...95% and no condensing as printed in field/value C1

P037 / Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V — source page 2 — PDF page 2

Specification Value Unit / basis Conditions
Environmental conditions / Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materi­als. Chemical gases, class 3C2 (coated boards 3C3). Solid particles, class 3S2. as printed in field/value C1
Environmental conditions / Component name VFX48-2K5-54 as printed in field/value C2
Environmental conditions / Vibrations According to IEC 60068-2-6, Sinusoidal vibrations: 10<f<57 Hz, 0.075 mm (0.00295 ft) 57<f<150 Hz, 1g (0,035 oz) as printed in field/value C3
Environmental conditions / Altitude 0–1000 m (0 - 3280 ft) with derating 1%/100 m (328 ft) of rated current as printed in field/value C1
Environmental conditions / Storage temperature -20 to +60 °C (-4 to + 140 °F) as printed in field/value C1
Environmental conditions / Storage atmospheric pressure 86–106 kPa (12.5 - 15.4 PSI) as printed in field/value C1
Environmental conditions / Storage relative humidity according to IEC60721-3-1 Class 1K4, max. 95% and no condensing and no formation of ice. as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Analogue voltage/current 0-±10 V/0-20 mA via switch as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Max. input voltage +30 V as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Input impedance 20 kΩ (voltage), 250 Ω (current) as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Resolution 11 bits + sign as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Hardware accuracy 0.5% type + 1 ½ LSB fsd as printed in field/value C1
Control signal inputs: Analogue (differential), 4 channels / Non-linearity 1½ LSB as printed in field/value C1
Digital inputs: 8 channels / Input voltage High >9 VDC, Low<4 VDC as printed in field/value C1
Digital inputs: 8 channels / Max. input voltage +30 VDC as printed in field/value C1
Digital inputs: 8 channels / Input impedance <3.3 VDC: 4.7 kΩ , ≥3.3 VDC: 3.6 kΩ as printed in field/value C1
Digital inputs: 8 channels / Signal delay ≤8 ms as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output voltage/current 0-10 V/0-20 mA via software setting as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Max. output voltage +15 V @5 mA cont. as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Short-circuit current (∞) +15 mA (voltage) +140 mA (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Output impedance 10 Ω (voltage) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Resolution 10 bit as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Maximum load impedance for current 500 Ω as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Hardware accuracy 1.9% type fsd (voltage), 2.4% type fsd (current) as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Offset 3 LSB as printed in field/value C1
Control signal outputs: Analogue, 2 channels / Non-linearity 2 LSB as printed in field/value C1
Digital outputs: 2 channels / Output voltage High>20 VDC @50 mA, >23 VDC open Low<1 VDC @50 mA as printed in field/value C1
Digital outputs: 2 channels / Short-circuit current (∞) 100 mA max (together with +24 VDC) as printed in field/value C1
Relays, 3pcs / Contacts 0.1 – 2 A/Umax 250 VAC or 42 VDC as printed in field/value C1
Reference voltages / +10 VDC +10 VDC @10 mA short-circuit current +30 mA max as printed in field/value C1
Reference voltages / -10 VDC -10 VDC @10 mA as printed in field/value C1

P037 / Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V — source page 3 — PDF page 3

Specification Value Unit / basis Conditions
Reference voltages / +24 VDC +24 VDC short-circuit current +100 mA max (together with Digital Outputs) as printed in field/value C1

P037 / Variable speed drive VFX69-3K0-IP/ 2400KW/ 400-690V — source page 6 — PDF page 6

Specification Value Unit / basis Conditions
Terminal X1 / 1 / Name +10V as printed in field/value C1
Terminal X1 / 1 / Default function +10 VDC Supply voltage as printed in field/value C1
Terminal X1 / 2 / Name AnIn 1 as printed in field/value C1
Terminal X1 / 2 / Default function Speed reference as printed in field/value C1
Terminal X1 / 3 / Name AnIn 2 as printed in field/value C1
Terminal X1 / 3 / Default function Not Used as printed in field/value C1
Terminal X1 / 4 / Name AnIn 3 as printed in field/value C1
Terminal X1 / 4 / Default function Not Used as printed in field/value C1
Terminal X1 / 5 / Name AnIn 4 as printed in field/value C1
Terminal X1 / 5 / Default function Not Used as printed in field/value C1
Terminal X1 / 6 / Name -10V as printed in field/value C1
Terminal X1 / 6 / Default function -10VDC Supply voltage as printed in field/value C1
Terminal X1 / 7 / Name Common as printed in field/value C1
Terminal X1 / 7 / Default function Signal ground as printed in field/value C1
Terminal X1 / 8 / Name DigIn 1 as printed in field/value C1
Terminal X1 / 8 / Default function RunL as printed in field/value C1
Terminal X1 / 9 / Name DigIn 2 as printed in field/value C1
Terminal X1 / 9 / Default function RunR as printed in field/value C1
Terminal X1 / 10 / Name DigIn 3 as printed in field/value C1
Terminal X1 / 10 / Default function Not Used as printed in field/value C1
Terminal X1 / 11 / Name +24VDC as printed in field/value C1
Terminal X1 / 11 / Default function +24VDC Supply voltage as printed in field/value C1
Terminal X1 / 12 / Name Common as printed in field/value C1
Terminal X1 / 12 / Default function Signal ground as printed in field/value C1
Terminal X1 / 13 / Name AnOut 1 as printed in field/value C1
Terminal X1 / 13 / Default function Min speed to max speed as printed in field/value C1
Terminal X1 / 14 / Name AnOut 2 as printed in field/value C1
Terminal X1 / 14 / Default function 0 to max torque as printed in field/value C1
Terminal X1 / 15 / Name Common as printed in field/value C1
Terminal X1 / 15 / Default function Signal ground as printed in field/value C1
Terminal X1 / 16 / Name DigIn 4 as printed in field/value C1
Terminal X1 / 16 / Default function Not Used as printed in field/value C1
Terminal X1 / 17 / Name DigIn 5 as printed in field/value C1
Terminal X1 / 17 / Default function Not Used as printed in field/value C1
Terminal X1 / 18 / Name DigIn 6 as printed in field/value C1
Terminal X1 / 18 / Default function Not Used as printed in field/value C1
Terminal X1 / 19 / Name DigIn 7 as printed in field/value C1
Terminal X1 / 19 / Default function Not Used as printed in field/value C1
Terminal X1 / 20 / Name DigOut 1 as printed in field/value C1
Terminal X1 / 20 / Default function Ready as printed in field/value C1
Terminal X1 / 21 / Name DigOut 2 as printed in field/value C1
Terminal X1 / 21 / Default function Brake/No trip as printed in field/value C1
Terminal X1 / 22 / Name DigIn 8 as printed in field/value C1
Terminal X1 / 22 / Default function Reset as printed in field/value C1
Terminal X2 / 31 / Name N/C 1 as printed in field/value C1
Terminal X2 / 31,32,33 / Shared relay function Relay 1 Output= Trip. Active when the AC drive is in a Trip condition. The N/C is opened when the relay is active (valid for all relays). The N/O is closed when the relay is active (valid for all relays). as printed in field/value C2
Terminal X2 / 32 / Name COM 1 as printed in field/value C1
Terminal X2 / 33 / Name N/O 1 as printed in field/value C1
Terminal X2 / 41 / Name N/C 2 as printed in field/value C1
Terminal X2 / 41,42,43 / Shared relay function Relay 2 Output= Ready. Active when the AC drive is ready to start. as printed in field/value C2
Terminal X2 / 42 / Name COM 2 as printed in field/value C1
Terminal X2 / 43 / Name N/O 2 as printed in field/value C1
Terminal X3 / 51 / Name COM 3 as printed in field/value C1
Terminal X3 / 51,52 / Shared relay function Relay 3 Output= Not used. as printed in field/value C2
Terminal X3 / 52 / Name N/O 3 as printed in field/value C1
Drive dimensions H x W x D (Hx Wx D): preliminary 2250x 4500x 600 (mm). mm C3

Selection checks and source differences

Each website row is keyed by table ID plus row ID. Repeated row numbers in separate tables are distinct associations, not a single78-row inventory.

Individual sheet component names repeat VFX48-2K5-54 despite distinct title models; power-factor percent/0.95 and g/oz vibration units are literal conflicts. High-voltage input/output scope is not reconciled by inference.

F33 and V33 maximum-current, parameter-current and family-specific option data differ. The shared sine-wave filter is F33-only. Safe Stop and braking equipment remain conditional options.

The manual derating example states68A motor current but selects32.4A capability. It is retained as a source contradiction, not a recommended selection.

Catalogue/manually printed model spelling, code gaps, voltage-specific rows and graphical comparator ambiguity are preserved. Historical compliance/approval statements are not independently verified current certificates.

Product documents

Our company certificates and conditions of sale remain separate from the selected product’s ratings and approvals.

Talk to our team about your application, supply, motor rating and configuration.