TECO RSXi Soft Starter

TECO RSXi Soft Starter

Compact Closed-Loop Soft Starter | 18–200 A | Up to 575 VAC

The TECO RSXi is a compact closed-loop soft starter designed for fixed-speed motor applications from 18 to 200 A, operating up to 575 VAC with an internal bypass included as standard. It is built for installations where the requirement is clear: controlled, reliable motor starting and stopping, integrated motor protection, and a compact footprint that simplifies panel design, without adding system complexity that the application does not warrant.

Where a motor is started direct-on-line, full voltage is applied immediately. The result is inrush current at six to eight times the motor’s rated value and an instantaneous torque transfer through whatever is connected to the shaft impellers, belts, couplings, gearboxes. The mechanical stress this introduces may not be catastrophic on the first start. It is cumulative. Repeated uncontrolled starts accelerate wear on driven equipment in ways that rarely get traced back to starting behaviour until a bearing fails early or a coupling requires unplanned replacement. The TECO RSXi addresses this directly. By regulating the current applied during acceleration and reducing voltage progressively at shutdown, it controls the rate of torque transfer through the drivetrain on every start cycle, not just under observation.

Motor protection is built in as standard, removing the need for separate overload relays, phase monitors or thermistor modules in the panel. For rural pump stations, compact MCC installations and DOL or star-delta replacement projects across Australia and New Zealand, that integration reduces wiring complexity, panel footprint and commissioning time in a single specification decision.

The TECO RSXi is the correct specification when the motor is within the 18–200 A range, the application is well-defined, and adaptive acceleration profiling, active braking or advanced diagnostics are not genuine requirements. TECO RSXi is a robust, low-maintenance solution with an operational life of up to one million operations on smaller frame sizes and zero harmonic emission in the run state — relevant wherever supply power quality is a consideration.

  • Closed-loop current control with two-phase SCR switching
  • Internal bypass contactor standard on all frames
  • Adjustable current ramp and configurable current limit
  • Soft stop function with adjustable deceleration time
  • Motor overload protection with selectable trip class
  • Excess start time protection
  • Current imbalance protection
  • Phase sequence protection
  • Supply frequency protection
  • Motor thermistor input
  • Zero harmonic emission in the run state
  • Up to 1,000,000 operations on 18–100 A frames
  • Optional communication modules — DeviceNet, Modbus, Modbus TCP, Profibus, Profinet, Ethernet
  • Controlled torque transfer on every start cycle reduces mechanical shock on couplings, gearboxes, belts and driven equipment.
  • Internal bypass reduces heat dissipation to approximately 10 watts during normal operation, simplifying panel thermal management.
  • Starting behaviour configured to match the specific application — not a generic default.
  • Progressive deceleration at shutdown reduces pipeline pressure transients and mechanical stress on driven equipment.
  • Comprehensive motor protection built into a single unit — no separate overload relays, phase monitors or thermistor modules required in the panel.
  • Abnormal start conditions caught before they cause damage — stalled loads, phase faults and supply quality issues detected automatically.
  • Zero harmonic emission in the run state eliminates the need for additional supply filtering equipment.
  • Long operational life with minimal maintenance — suited to remote installations and high-cycle applications where access is limited.
Specification Value
Current range 18 A – 200 A
Operating voltage 200–440 VAC standard (V4) | 200–575 VAC extended (V6)
Control voltage 110 – 240VAC and 380-440VAC (C1) | 24VAC / VDC optional (C2)
Control topology Two-phase SCR with closed-loop current control
Bypass Internal — activates at full speed
Start methods Current ramp, configurable current limit
Stop methods Soft stop with adjustable deceleration time
Braking Not available
Adaptive control Not available
Thermal protection Motor overload with selectable trip class
Motor thermistor Input provided as standard
Harmonic emission Zero in run state
Operational life Up to 1,000,000 operations (18–100 A frames) | 30,000 operations (140–200 A frames)
Communication Optional: DeviceNet, Modbus, Modbus TCP, Profibus, Profinet, Ethernet
Markets Australia and New Zealand

TECO RSXi Soft Starter

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Current Rating Datasheet & Drawing PDF
1 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 18 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-018-V4-C1-Soft-Starter.pdf
2 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 34 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-034-V4-C1-Soft-Starter.pdf
3 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 42 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-042-V4-C1-Soft-Starter.pdf
4 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 48 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-048-V4-C1-Soft-Starter.pdf
5 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 60 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-060-V4-C1-Soft-Starter.pdf
6 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 75 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-075-V4-C1-Soft-Starter.pdf
7 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 85 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-085-V4-C1-Soft-Starter.pdf
8 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 100 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-100-V4-C1-Soft-Starter.pdf
9 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 140 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-140-V4-C1-Soft-Starter.pdf
10 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 170 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-170-V4-C1-Soft-Starter.pdf
Current Rating

Features

  • Closed-loop current control with two-phase SCR switching
  • Internal bypass contactor standard on all frames
  • Adjustable current ramp and configurable current limit
  • Soft stop function with adjustable deceleration time
  • Motor overload protection with selectable trip class
  • Excess start time protection
  • Current imbalance protection
  • Phase sequence protection
  • Supply frequency protection
  • Motor thermistor input
  • Zero harmonic emission in the run state
  • Up to 1,000,000 operations on 18–100 A frames
  • Optional communication modules — DeviceNet, Modbus, Modbus TCP, Profibus, Profinet, Ethernet

Benefits

  • Controlled torque transfer on every start cycle reduces mechanical shock on couplings, gearboxes, belts and driven equipment.
  • Internal bypass reduces heat dissipation to approximately 10 watts during normal operation, simplifying panel thermal management.
  • Starting behaviour configured to match the specific application — not a generic default.
  • Progressive deceleration at shutdown reduces pipeline pressure transients and mechanical stress on driven equipment.
  • Comprehensive motor protection built into a single unit — no separate overload relays, phase monitors or thermistor modules required in the panel.
  • Abnormal start conditions caught before they cause damage — stalled loads, phase faults and supply quality issues detected automatically.
  • Zero harmonic emission in the run state eliminates the need for additional supply filtering equipment.
  • Long operational life with minimal maintenance — suited to remote installations and high-cycle applications where access is limited.

Technical Summary

Specification Value
Current range 18 A – 200 A
Operating voltage 200–440 VAC standard (V4) | 200–575 VAC extended (V6)
Control voltage 110 – 240VAC and 380-440VAC (C1) | 24VAC / VDC optional (C2)
Control topology Two-phase SCR with closed-loop current control
Bypass Internal — activates at full speed
Start methods Current ramp, configurable current limit
Stop methods Soft stop with adjustable deceleration time
Braking Not available
Adaptive control Not available
Thermal protection Motor overload with selectable trip class
Motor thermistor Input provided as standard
Harmonic emission Zero in run state
Operational life Up to 1,000,000 operations (18–100 A frames) | 30,000 operations (140–200 A frames)
Communication Optional: DeviceNet, Modbus, Modbus TCP, Profibus, Profinet, Ethernet
Markets Australia and New Zealand

Datasheets & Drawings

TECO RSXi Soft Starter

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Current Rating Datasheet & Drawing PDF
1 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 18 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-018-V4-C1-Soft-Starter.pdf
2 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 34 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-034-V4-C1-Soft-Starter.pdf
3 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 42 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-042-V4-C1-Soft-Starter.pdf
4 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 48 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-048-V4-C1-Soft-Starter.pdf
5 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 60 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-060-V4-C1-Soft-Starter.pdf
6 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 75 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-075-V4-C1-Soft-Starter.pdf
7 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 85 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-085-V4-C1-Soft-Starter.pdf
8 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 100 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-100-V4-C1-Soft-Starter.pdf
9 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 140 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-140-V4-C1-Soft-Starter.pdf
10 mojodojo 27/03/2026 09:11 AM mojodojo 27/03/2026 09:11 AM 170 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2026/03/RSXi-170-V4-C1-Soft-Starter.pdf
Current Rating
Book a Consultation
Have questions or need assistance? Reach out to us through the contact form, and we’ll be happy to assist you.
This field is for validation purposes and should be left unchanged.
Drop files here or
Max. file size: 100 MB.