Chat with us, powered by LiveChat
Rotating the World Sustainably & Reliably with TECO’s Solutions
TECO IE3 Flameproof (Exd)

TECO IE3 Flameproof (Exd)

TECO IE3 Flameproof (Exd) – Safe, Efficient, and Reliable Solutions for Hazardous Environments, IP56 Protection

TECO IE3 Flameproof (Ex d) Total Enclosed Fan Cooled Motor is designed with safety certifications and key features to ensure reliable performance in hazardous environments. These motors are IEC Ex and ATEX certified.
TECO IE3 Flameproof (Ex d) Electric Motor features metric frames aligned with IEC60034 and AS/BS frame allocation, ranging from D80 to D315 frames.It has power outputs varying from 0.75 kW to 30 kW (stock) and can be custom-built up to 110 kW.

Totally Enclosed Fan Cooled (IC411) design and belong to the motor types AEMBXZ/AEMVXZ, meeting or exceeding the Minimum Efficiency Performance Standard IEC60034. Both 380~415 Volts 3 Phase 50 Hz and 1000v 3 Phase 50Hz are available in stock or to order and we can accommodate other supplies upon request. TECO IE3 Flameproof (Ex d) Electric Motor has high-quality insulation system utilising Class H materials.

With low temperature rise and continuous rated duty type S1, TECO IE3 Flameproof (Ex d) Electric Motor provides reliable performance with reduced noise levels. The IP56 protection against ingress of solids and liquids, making it suitable for various industrial applications. The Motor is supplied painted R13 Red and is constructed with cast iron and features a side-mounted terminal box.
To ensure customer satisfaction, the motor comes with a 2-year warranty.

  • IEC Ex and ATEX Certified with certification available as :
  • Ex d (Flameproof Motor and Terminal Box)
  • Ex db I Mb and Ex db IIB T4* Gb both at ambient range -20 deg C to 55 deg for frames 80 to 280
  • Ex db I Mb and Ex db IIC T4* Gb both at ambient range -20 deg C to 55 deg for frame 315 only
  • *T4 for converter supply (PWM Converter , Inverter) . Condition of safe use is mandatory connection of thermistors.
  • Metric frame motors to AS1359, AS/BS frame allocation
  • D80 to D315 frames
  • 0.75 kW to 7.5 kW (Stock) or up to 110kW (Built to Order)
  • Totally Enclosed Fan Cooled (IC411)
  • Motor type AEMBXZ/AEMVXZ , meets or exceeds AS1359.5 Minimum Efficiency Performance Standard, table B2             (a number of motors meet or exceed high efficiency to table B3)
  • 380~415 Volts 3 Phase 50 Hz (other supplies on request)
  • Highest quality insulation system utilizing Class H materials
  • Low temperature rise for substantial thermal reserve
  • Continuous rated, duty type S1
  • Low noise level
  • IP56 protection
  • Motors available painted R13 red (AS2700) off the shelf.
  • Cast Iron construction with side mounted terminal box
  • Mountings available – Foot, Foot and flange (D type only), Flange (D type only)
  • MAX Ex Brake Motors
  • 2 year warranty​
  • Ensures reliable performance in hazardous environments
  • Meets international safety certifications for hazardous areas (Exd)
  • Wide range of certifications available based on temperature range and frame size
  • Compatible with metric frames and AS/BS frame allocation standards
  • Suitable for various frame sizes, providing flexibility in motor selection
  • Offers a range of power outputs to meet different application requirements
  • Provides efficient cooling with a Totally Enclosed Fan Cooled design
  • Uses high-quality insulation materials for enhanced durability
  • Suitable for continuous operation under normal working conditions
  • Reduces noise levels for a quieter working environment

No software downloads.

TECO IE3 Flameproof (Exd) Drawings

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Frame Size PDF Drawings CAD Drawings 3D Drawings
1 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1594.zip Available Upon Request Available Upon Request
2 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1605.zip Available Upon Request Available Upon Request
3 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1610.zip Available Upon Request Available Upon Request
4 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 112M https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1614.zip Available Upon Request Available Upon Request
5 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 132M https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1622.zip Available Upon Request Available Upon Request
6 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 132S https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1621.zip Available Upon Request Available Upon Request
7 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160L-2P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1633.zip Available Upon Request Available Upon Request
8 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160L-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1630.zip Available Upon Request Available Upon Request
9 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160M-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1626.zip Available Upon Request Available Upon Request
10 nate 11/11/2024 04:25 PM nate 19/11/2024 04:18 PM 180LC-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1638.zip Available Upon Request Available Upon Request
Frame Size

TECO IE3 Flameproof (Exd) Datasheets

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at KW Rating Voltage Phases No of Poles Frame Datasheet PDF
1 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 2 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1593.pdf
2 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 4 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1594.pdf
3 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 6 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1595.pdf
4 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 8 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1596.pdf
5 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 2 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1597.pdf
6 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 4 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1598.pdf
7 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 6 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1599.pdf
8 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 8 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1600.pdf
9 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.50 415 3 2 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1601.pdf
10 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.50 415 3 4 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1602.pdf
KW Rating Voltage Phases No of Poles Frame

Features

  • IEC Ex and ATEX Certified with certification available as :
  • Ex d (Flameproof Motor and Terminal Box)
  • Ex db I Mb and Ex db IIB T4* Gb both at ambient range -20 deg C to 55 deg for frames 80 to 280
  • Ex db I Mb and Ex db IIC T4* Gb both at ambient range -20 deg C to 55 deg for frame 315 only
  • *T4 for converter supply (PWM Converter , Inverter) . Condition of safe use is mandatory connection of thermistors.
  • Metric frame motors to AS1359, AS/BS frame allocation
  • D80 to D315 frames
  • 0.75 kW to 7.5 kW (Stock) or up to 110kW (Built to Order)
  • Totally Enclosed Fan Cooled (IC411)
  • Motor type AEMBXZ/AEMVXZ , meets or exceeds AS1359.5 Minimum Efficiency Performance Standard, table B2             (a number of motors meet or exceed high efficiency to table B3)
  • 380~415 Volts 3 Phase 50 Hz (other supplies on request)
  • Highest quality insulation system utilizing Class H materials
  • Low temperature rise for substantial thermal reserve
  • Continuous rated, duty type S1
  • Low noise level
  • IP56 protection
  • Motors available painted R13 red (AS2700) off the shelf.
  • Cast Iron construction with side mounted terminal box
  • Mountings available – Foot, Foot and flange (D type only), Flange (D type only)
  • MAX Ex Brake Motors
  • 2 year warranty​

Benefits

  • Ensures reliable performance in hazardous environments
  • Meets international safety certifications for hazardous areas (Exd)
  • Wide range of certifications available based on temperature range and frame size
  • Compatible with metric frames and AS/BS frame allocation standards
  • Suitable for various frame sizes, providing flexibility in motor selection
  • Offers a range of power outputs to meet different application requirements
  • Provides efficient cooling with a Totally Enclosed Fan Cooled design
  • Uses high-quality insulation materials for enhanced durability
  • Suitable for continuous operation under normal working conditions
  • Reduces noise levels for a quieter working environment

Software

No software downloads.

Drawings

TECO IE3 Flameproof (Exd) Drawings

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Frame Size PDF Drawings CAD Drawings 3D Drawings
1 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1594.zip Available Upon Request Available Upon Request
2 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1605.zip Available Upon Request Available Upon Request
3 nate 11/11/2024 04:25 PM nate 19/11/2024 04:16 PM 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1610.zip Available Upon Request Available Upon Request
4 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 112M https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1614.zip Available Upon Request Available Upon Request
5 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 132M https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1622.zip Available Upon Request Available Upon Request
6 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 132S https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1621.zip Available Upon Request Available Upon Request
7 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160L-2P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1633.zip Available Upon Request Available Upon Request
8 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160L-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1630.zip Available Upon Request Available Upon Request
9 nate 11/11/2024 04:25 PM nate 19/11/2024 04:17 PM 160M-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1626.zip Available Upon Request Available Upon Request
10 nate 11/11/2024 04:25 PM nate 19/11/2024 04:18 PM 180LC-4P https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/PDFdrawings-1638.zip Available Upon Request Available Upon Request
Frame Size

Data Sheet

TECO IE3 Flameproof (Exd) Datasheets

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at KW Rating Voltage Phases No of Poles Frame Datasheet PDF
1 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 2 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1593.pdf
2 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 4 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1594.pdf
3 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 6 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1595.pdf
4 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 0.75 415 3 8 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1596.pdf
5 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 2 80 https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1597.pdf
6 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 4 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1598.pdf
7 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 6 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1599.pdf
8 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.10 415 3 8 100L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1600.pdf
9 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.50 415 3 2 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1601.pdf
10 nate 11/11/2024 12:03 PM nate 11/11/2024 12:03 PM 1.50 415 3 4 90L https://electricmotors.teco.com.au/wp-content/uploads/sites/53/2024/04/Datasheet-1602.pdf
KW Rating Voltage Phases No of Poles Frame
Book a Consultation
Have questions or need assistance? Reach out to us through the contact form, and we’ll be happy to assist you.
Drop files here or
Max. file size: 100 MB.
    This field is for validation purposes and should be left unchanged.