TECO Electric Motors for Hazardous Areas
We build motors around demanding industrial duties, with hazardous-area options for oil and gas, chemical processing and other applications where the motor must match the site classification. Our published large-motor range covers 185–10,000 kW, 2–12 poles and frames 315–1000. We work with you to establish the electrical, mechanical and protection requirements of the complete installation.
Range and operating conditions
These are range-level specifications. They do not establish that every output, voltage, frame, cooling method and protection type is available in every combination.
| Feature | Published range specification |
|---|---|
| Output | 185–10,000 kW |
| Poles | 2–12 |
| Cooling | Totally enclosed air-to-air cooled (TEAAC) or totally enclosed fan cooled (TEFC) |
| Enclosure protection | IP54–IP66, according to configuration |
| Frames | 315–1000 |
| Ambient | 40°C |
| Elevation | 1,000 m above sea level |
| Service factor | 1.0 at 40°C |
| Mounting | IM1001 |
| Supply voltage | Up to 11,000 V |
| Insulation | Class F, 155°C classification; temperature rise ΔT = 80 K |
| Duty | S1 continuous |
| Design | N |
| Thermal protection | To customer specification |
| Bearings | Anti-friction or sleeve; oil forced or self-cooled arrangements as selected |
| Frame material | Fabricated steel |
| Colour | To customer specification |
We describe the TECO Westinghouse Thermalastic™ form-wound insulation system for our high-voltage designs. The insulation class, allowable rise and ambient rating are different quantities: the 155°C classification is not an allowable site ambient temperature.
Select the protection for your installation
Our range page lists Ex n, Ex e, Ex d, Ex de and Ex p options. These identify different protection arrangements; they are not interchangeable approvals. We need the site classification, gas or dust characteristics, required equipment protection level, temperature requirements and installation conditions to establish the appropriate motor.
The documents attached to this page do not include a product-specific hazardous-area certificate or a model-by-model certified schedule. We therefore do not assign a gas group, temperature class, zone, converter operating range or special condition to an individual motor from the range description alone. Confirm the selected motor’s full marking, certificate, certified drawings and conditions with us before selection or installation.
For flameproof and increased-safety arrangements, the enclosure, terminal box and cable entries must be treated as the selected complete configuration. Corrosion resistance, unusually high or low ambient temperatures and drive operation require an agreed design. Our general descriptions of durability and efficient operation do not add an unlisted environmental rating or efficiency percentage.
Engineer the motor around the duty
Share the driven load, speed and starting requirements, supply, mounting, shaft dimensions, bearing loads, cooling arrangements and site conditions. We can then confirm the thermal protection, bearing and lubrication arrangement, enclosure and finish for your project. Replacement compatibility depends on the agreed outline and connection details.
Our September 2025 Large Motors and Drives brochure explains our broader capabilities: IEC and NEMA designs, vertical and horizontal arrangements, foot and flange options, purpose-built replacements, oversized sleeve or anti-friction bearings and project-specific ventilation and terminal boxes. Its AFJN/AFJP TEFC cast-iron and HV SCIM TEAAC sections are separate portfolio examples. Their construction descriptions do not replace this page’s fabricated-steel range specification.
The brochure’s 150–22,000 kW cover range, wider voltage claims and wound-rotor/MV510 sections describe the wider portfolio. They do not expand this hazardous-area product to those ratings or establish compatibility with every drive. Capacity graphics have no extracted numerical endpoints; we do not create model ratings by measuring their bars. The brochure’s power-density and weight comparisons have no stated comparison baseline, so we do not apply those percentages to this range.
Receipt, installation and maintenance
The linked 3A057D872E REV.07 three-phase induction-motor manual covers several motor constructions. Use it together with the selected motor’s instructions, hazardous-area certificate and certified drawings. Its general maintenance tables below remain conditional references; they cannot override a protection-specific restriction.
Check the delivery against the order and nameplate, inspect for damage, and keep storage and insulation-test records. Store the motor dry, ventilated and protected from vibration and corrosion. Follow the bearing-specific storage instructions and use heaters as specified. Motor lifting points support the motor, not the connected driven assembly; restore the specified transport restraints before moving it again.
Before starting, qualified personnel must check the foundation, alignment, wiring, earthing, protection, rotation, lubrication and any independent cooling. Keep cooling paths clear and monitor temperature, noise and vibration. Heaters must be off while the motor runs. The manual’s two-cold-start/one-hot-start guidance and additional-start cooling periods of 60 minutes loaded or 30 minutes unloaded remain subject to the actual motor duty. Its ±10% voltage, ±5% frequency and combined ±10% statements are general source guidance, not hazardous-area operating permission or a VSD envelope.
The manual’s insulation-test guidance quotes a historical standard and leaves exactly 1,000 V unspecified between its below/above categories. Use the confirmed test procedure; no missing boundary is inferred. The controlled drying procedure must be read in full. Brush and slip-ring instructions concern wound-rotor constructions, not every motor on this page.
Use the lubrication nameplate first. REV07 names SHELL Alvania RL3 unless otherwise specified and prohibits mixing grease types. Its maximum replenishment quantities and wording about replacing old grease must be resolved for the installed bearing. Ratchet-pin replacement guidance—three years, halved for the stated reverse-shock or frequent-start conditions—applies only to that optional vertical mechanism. Historical solvent and disposal descriptions are not presented as current working instructions.
Documents and selection support
We retain the complete 12-page brochure and 51-page manual, with the applicable reference tables below. No dedicated model datasheet, dimensional drawing or certificate was attached to this product in the collected source set. Ask us for the approved configuration documents for your installation; the range endpoints are not a substitute for them.
Manual — Installation references — REV07
Use the selected motor’s outline, nameplate and complete instructions. General site, foundation, alignment and belt references do not authorise a particular belt load or replace a hazardous-area approval.
Usual site limits — PDF page 8
| Source row | Property | Source condition |
|---|---|---|
| 1 | Ambient temperature | −20 to +40°C |
| 2 | Relative humidity totally enclosed | Below95% |
| 3 | Relative humidity semi-enclosed | Below80% |
| 4 | Elevation | Below1000m |
| 5 | Water-cooled motor or bearing cooling coil | Ambient should not be below0°C to prevent frost damage |
Horizontal four-bolt foundation reactions — PDF page 8
| Source row | Load case | Reaction kg per bolt at centreline |
|---|---|---|
| 1 | Static weight | Motor weight / bolt number |
| 2 | Rated torque | Motor weight / bolt number ± TR/(2L) |
| 3 | Maximum torque | Motor weight / bolt number ± Tmax/(2L) |
Alignment tolerances — PDF page 13
| Source row | TIR | Rotating speed | Solid coupling (mm) | Flexible coupling (mm) |
|---|---|---|---|---|
| 1 | C | 2500rpm and above | 0.03 | 0.03 |
| 2 | C | Below 2500rpm | 0.04 | 0.05 |
| 3 | A | 2500rpm and above | 0.03 | 0.03 |
| 4 | A | Below 2500rpm | 0.03 | 0.04 |
Belt-sheave application for general electric motors — PDF page 16
| Source row | Output4P(kW) | Output6P(kW) | Output8P(kW) | Conventional V-belt type | Conventional belt count | Conventional minimum PCD(mm) | Conventional maximum width(mm) | Narrow V-belt type | Narrow belt count | Narrow minimum PCD(mm) | Narrow maximum width(mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 11 | -- | -- | B | 4 | 160 | 82 | 3V | 4 | 125 | 48 |
| 2 | -- | 11 | -- | B | 5 | 170 | 101 | 3V | 5 | 140 | 59 |
| 3 | -- | -- | 11 | B | 5 | 190 | 101 | 3V | 6 | 160 | 69 |
| 4 | 15 | -- | -- | B | 5 | 170 | 101 | 3V | 6 | 125 | 69 |
| 5 | -- | 15 | -- | B | 5 | 224 | 101 | 3V | 6 | 160 | 69 |
| 6 | -- | -- | 15 | C | 4 | 224 | 111 | 5V | 3 | 180 | 60 |
| 7 | 18.5 | -- | -- | B | 5 | 200 | 101 | 3V | 6 | 140 | 69 |
| 8 | -- | 18.5 | -- | C | 4 | 224 | 111 | 5V | 3 | 180 | 60 |
| 9 | -- | -- | 18.5 | C | 5 | 224 | 136 | 5V | 4 | 180 | 78 |
| 10 | 22 | -- | -- | B | 5 | 224 | 101 | 3V | 6 | 160 | 69 |
| 11 | -- | 22 | -- | C | 5 | 224 | 136 | 5V | 4 | 180 | 78 |
| 12 | -- | -- | 22 | C | 5 | 250 | 136 | 5V | 4 | 200 | 78 |
| 13 | 30 | -- | -- | C | 5 | 224 | 136 | 5V | 4 | 180 | 78 |
| 14 | -- | 30 | -- | C | 5 | 265 | 136 | 5V | 4 | 224 | 78 |
| 15 | -- | -- | 30 | C | 6 | 265 | 162 | 5V | 5 | 224 | 95 |
| 16 | 37 | -- | -- | C | 6 | 224 | 162 | 5V | 4 | 200 | 78 |
| 17 | -- | 37 | -- | C | 6 | 265 | 162 | 5V | 4 | 224 | 78 |
| 18 | -- | -- | 37 | C | 7 | 280 | 187 | 5V | 5 | 250 | 95 |
| 19 | 45 | -- | -- | C | 6 | 265 | 162 | 5V | 4 | 224 | 78 |
| 20 | -- | 45 | -- | C | 7 | 280 | 187 | 5V | 5 | 224 | 95 |
| 21 | -- | -- | 45 | C | 7 | 315 | 187 | 5V | 6 | 250 | 113 |
| 22 | 55 | -- | -- | C | 7 | 265 | 187 | 5V | 5 | 224 | 95 |
| 23 | -- | 55 | -- | C | 8 | 300 | 213 | 5V | 6 | 250 | 113 |
| 24 | -- | -- | 55 | D | 5 | 355 | 196 | 5V | 6 | 280 | 113 |
| 25 | 75 | -- | -- | C | 8 | 315 | 213 | 5V | 6 | 250 | 113 |
| 26 | -- | 75 | -- | D | 6 | 355 | 233 | 5V | 6 | 315 | 113 |
| 27 | -- | -- | 75 | D | 6 | 400 | 233 | 5V | 6 | 355 | 113 |
| 28 | -- | 90 | -- | D | 6 | 400 | 233 | 5V | 6 | 355 | 113 |
| 29 | -- | -- | 90 | D | 6 | 425 | 233 | 8V | 4 | 355 | 124 |
| 30 | -- | 110 | -- | D | 7 | 400 | 270 | 8V | 4 | 355 | 124 |
| 31 | -- | 132 | 110 | D | 7 | 450 | 270 | 8V | 4 | 400 | 124 |
| 32 | -- | 160 | 132 | D | 9 | 450 | 344 | 8V | 4 | 450 | 124 |
Manual — Starting and monitoring — REV07
Qualified personnel must isolate, test and discharge equipment using the complete procedure. Drying limits, oil/water systems and bearing/winding monitoring apply only to the stated construction. A general supply tolerance is not an extension of certified hazardous-area limits.
Megger source instruction — PDF page 19
| Source row | Rated-voltage wording | DC megger voltage |
|---|---|---|
| 1 | Below1000V | 500VDC |
| 2 | Above1000V | 1000VDC |
IEEE43-2000 minimum insulation resistance as quoted — PDF page 19
| Source row | Winding scope | Minimum MΩ at40°C |
|---|---|---|
| 1 | Most windings made before1970,all field windings,and others not described below | kV+1 |
| 2 | Most DC armatures and AC windings built after about1970 with form-wound coils | 100 |
| 3 | Machines with random-wound stator coils and form-wound coils rated below1kV | 5 |
Drying and electrical supply conditions — PDF page 20
| Source row | Property | Source statement |
|---|---|---|
| 1 | Heating cycle | 15–20hours |
| 2 | Insulation evaluation temperature | Correct to40°C |
| 3 | Approximation for new winding above dew point | Resistance approximately halves per10°C increase |
| 4 | Supply capacity | Must be sufficient |
| 5 | Supply voltage and frequency | Identical to nameplate ratings |
| 6 | Voltage variation | Within±10%rated value and phase-to-phase voltages balanced |
Flood lubrication oil inlet temperature — PDF page 21
| Source row | Condition | Source temperature |
|---|---|---|
| 1 | Normal | Below50°C (122°F) |
| 2 | Alarm | 60°C (140°F) |
| 3 | Trip | 65°C (149°F) |
Cooling-water inlet temperature alarm/trip — PDF page 23
| Source row | Inlet water condition | Temperature |
|---|---|---|
| 1 | Alarm | 35℃ (95℉) |
| 2 | Trip | 40℃ (104℉) |
Bearing temperature recommendations — PDF page 25
| Source row | Bearing type | Detector | Alarm temperature | Trip temperature |
|---|---|---|---|---|
| 1 | Sleeve Bearings. | By permanently installed detector | 90℃(194℉) | 95℃(203℉) |
| 2 | Anti-Friction Bearings. | By permanently installed detector | 95℃(203℉) | 100℃(212℉) |
Winding operating temperature recommendations — PDF page 26
| Source row | Service factor | Alarm | Trip |
|---|---|---|---|
| 1 | Service Factor 1.0 | 130℃ (266℉) | 150℃ (302℉) |
| 2 | Service Factor 1.15 (when specified) | 155℃ (311℉) | 165℃ (329℉) |
Manual — Lubrication — REV07
The lubrication nameplate and actual bearing, speed and duty take priority. Do not interpolate the discrete speed columns. The source halves grease intervals for belt drive or adverse conditions; use the shorter applicable bearing interval. Grease quantities are maximums for one replenishment per bearing. Do not mix grease types. Vertical and horizontal oil references are separate.
Table1 — 62XX/63XX/72XX/73XX — PDF page 30
| Source row | Bearing row label | 600 and720RPM / hours | 750 and900RPM / hours | 1000 and1200RPM / hours | 1500 and1800RPM / hours | 3000 and3600RPM / hours |
|---|---|---|---|---|---|---|
| 1 | 6210 | 3000 | 3000 | 3000 | 3000 | 2000 |
| 2 | 12 | 3000 | 3000 | 3000 | 3000 | 2000 |
| 3 | 13 | 3000 | 3000 | 3000 | 3000 | 1000 |
| 4 | 14 | 3000 | 3000 | 3000 | 3000 | 1000 |
| 5 | 15 | 3000 | 3000 | 3000 | 2000 | 720 |
| 6 | 16 | 3000 | 3000 | 3000 | 2000 | 720 |
| 7 | 17 | 3000 | 3000 | 3000 | 2000 | [outside chart boundary] |
| 8 | 18 | 3000 | 3000 | 3000 | 2000 | [outside chart boundary] |
| 9 | 20 | 3000 | 3000 | 3000 | 2000 | [outside chart boundary] |
| 10 | 22 | 3000 | 3000 | 3000 | 1500 | [outside chart boundary] |
| 11 | 24 | 3000 | 3000 | 3000 | 1500 | [outside chart boundary] |
| 12 | 26 | 3000 | 3000 | 2000 | 1000 | [outside chart boundary] |
| 13 | 28 | 3000 | 3000 | 2000 | 1000 | [outside chart boundary] |
| 14 | 30 | 3000 | 3000 | 2000 | 500 | [outside chart boundary] |
| 15 | 32 | 3000 | 3000 | 1500 | 500 | [outside chart boundary] |
| 16 | 34 | 3000 | 3000 | 1500 | [outside chart boundary] | [outside chart boundary] |
| 17 | 36 | 3000 | 2000 | 1000 | [outside chart boundary] | [outside chart boundary] |
| 18 | 38 | 3000 | 2000 | 1000 | [outside chart boundary] | [outside chart boundary] |
Table1 — NU2XX/NU3XX — PDF page 30
| Source row | Bearing row label | 600 and720RPM / hours | 750 and900RPM / hours | 1000 and1200RPM / hours | 1500 and1800RPM / hours |
|---|---|---|---|---|---|
| 1 | NU214 | 3000 | 3000 | 3000 | 2000 |
| 2 | 15 | 3000 | 3000 | 3000 | 2000 |
| 3 | 16 | 3000 | 3000 | 3000 | 2000 |
| 4 | 17 | 3000 | 3000 | 3000 | 1500 |
| 5 | 18 | 3000 | 3000 | 3000 | 1500 |
| 6 | 20 | 3000 | 3000 | 3000 | 1000 |
| 7 | 22 | 3000 | 3000 | 2000 | 1000 |
| 8 | 24 | 3000 | 3000 | 2000 | 1000 |
| 9 | 26 | 3000 | 3000 | 2000 | 500 |
| 10 | 28 | 3000 | 3000 | 2000 | 500 |
| 11 | 30 | 3000 | 2000 | 1000 | 500 |
| 12 | 32 | 3000 | 2000 | 1000 | [outside chart boundary] |
| 13 | 34 | 3000 | 2000 | 1000 | [outside chart boundary] |
| 14 | 36 | 2000 | 2000 | 1000 | [outside chart boundary] |
| 15 | 38 | 2000 | 1000 | 1000 | [outside chart boundary] |
| 16 | 40 | 2000 | 1000 | [outside chart boundary] | [outside chart boundary] |
| 17 | 44 | 1000 | 1000 | [outside chart boundary] | [outside chart boundary] |
| 18 | 48 | 1000 | 1000 | [outside chart boundary] | [outside chart boundary] |
Table1 — 222XX/223XX — PDF page 30
| Source row | Bearing row label | 600 and720RPM / hours | 750 and900RPM / hours | 1000 and1200RPM / hours | 1500 and1800RPM / hours |
|---|---|---|---|---|---|
| 1 | 22220 | 1000 | 1000 | 500 | 300 |
| 2 | 22 | 1000 | 1000 | 500 | [outside chart boundary] |
| 3 | 24 | 1000 | 1000 | 500 | [outside chart boundary] |
| 4 | 26 | 1000 | 1000 | 500 | [outside chart boundary] |
| 5 | 28 | 1000 | 500 | 300 | [outside chart boundary] |
| 6 | 30 | 1000 | 500 | 300 | [outside chart boundary] |
| 7 | 32 | 1000 | 500 | 300 | [outside chart boundary] |
| 8 | 34 | 500 | 500 | [outside chart boundary] | [outside chart boundary] |
| 9 | 36 | 500 | 500 | [outside chart boundary] | [outside chart boundary] |
| 10 | 38 | 500 | 300 | [outside chart boundary] | [outside chart boundary] |
| 11 | 40 | 500 | 300 | [outside chart boundary] | [outside chart boundary] |
| 12 | 44 | 300 | [outside chart boundary] | [outside chart boundary] | [outside chart boundary] |
| 13 | 48 | 300 | [outside chart boundary] | [outside chart boundary] | [outside chart boundary] |
Table2 — 62XX/72XX/NU2XX/222XX — PDF page 31
| Source row | Printed bearing number | Maximum replenishment g |
|---|---|---|
| 1 | 6210 | 30 |
| 2 | 6212 | 40 |
| 3 | 6213 | 50 |
| 4 | 6214 | 50 |
| 5 | 6215 | 60 |
| 6 | 6216 | 60 |
| 7 | 6217 | 80 |
| 8 | 6218 | 80 |
| 9 | 6220 | 100 |
| 10 | 6222 | 120 |
| 11 | 6224 | 120 |
| 12 | 6226 | 140 |
| 13 | 6228 | 160 |
| 14 | 6230 | 180 |
| 15 | 6232 | 200 |
| 16 | 6234 | 250 |
| 17 | 6236 | 300 |
| 18 | 6238 | 350 |
| 19 | 6240 | 400 |
| 20 | 6244 | 450 |
| 21 | 6248 | 500 |
Table2 — 63XX/73XX/NU3XX/223XX — PDF page 31
| Source row | Printed bearing number | Maximum replenishment g |
|---|---|---|
| 1 | 6310 | 40 |
| 2 | 6312 | 60 |
| 3 | 6313 | 80 |
| 4 | 6314 | 80 |
| 5 | 6315 | 100 |
| 6 | 6316 | 100 |
| 7 | 6317 | 120 |
| 8 | 6318 | 120 |
| 9 | 6320 | 160 |
| 10 | 6322 | 220 |
| 11 | 6324 | 270 |
| 12 | 6326 | 300 |
| 13 | 6328 | 400 |
| 14 | 6330 | 450 |
| 15 | 6332 | 500 |
| 16 | 6334 | 600 |
| 17 | 6336 | 700 |
| 18 | 6338 | 800 |
| 19 | 6340 | 900 |
| 20 | 6344 | 900 |
| 21 | 6348 | 900 |
Table3 — vertical motor oil viscosity — PDF page 33
| Source row | Bearing type | Oil viscosity | Pole scope |
|---|---|---|---|
| 1 | Angular contact ball72XX,73XX | ISO VG32 (150SSU/100°F) | 2pole |
| 2 | Angular contact ball72XX,73XX | ISO VG68 (300SSU/100°F) | 4pole andabove |
| 3 | Spherical roller293XX,294XX | ISO VG68 (300SSU/100°F) | 4pole |
| 4 | Spherical roller293XX,294XX | ISO VG150 (700SSU/100°F) | 6pole andabove |
| 5 | RENK Vertical Bearing Inserts TypeEV orKingsbury Type | ISO VG68 (300SSU/100°F) | 4pole andabove |
Table4 — horizontal motor oil viscosity — PDF page 33
| Source row | Bearing type | Oil viscosity | Pole scope |
|---|---|---|---|
| 1 | Sleeve bearing | ISO VG32 (150SSU/100°F) | 2pole |
| 2 | Sleeve bearing | ISO VG46 (200SSU/100°F) | 4pole |
| 3 | Sleeve bearing | ISO VG68 (300SSU/100°F) | 6pole andabove |
Source oil equivalent names — PDF page 35
| Source row | ISO | ESSO equivalent | MOBIL equivalent | cSt at40°C | SUS/100°F |
|---|---|---|---|---|---|
| 1 | VG32 | ESSO TERESSO32 | MOBIL DTE OIL LIGHT | 32 | 150 |
| 2 | VG46 | ESSO TERESSO46 | MOBIL DTE OIL MEDIUM | 46 | 200 |
| 3 | VG68 | ESSO TERESSO68 | MOBIL OIL HEAVY MEDIUM | 68 | 300 |
| 4 | VG150 | ESSO NUTO150 | MOBIL DTE OIL EXTRA HEAVY | 150 | 700 |
Manual — Optional ratchet, troubleshooting and materials — REV07
The non-reverse ratchet applies only to an equipped vertical high-thrust motor. Troubleshooting is for qualified diagnosis with the full safety procedure; material percentages are source averages, not a selected motor’s bill of materials.
Non-reverse ratchet component labels — PDF page 40
| Source row | Item | Name |
|---|---|---|
| 1 | 104 | RATCHET |
| 2 | 214 | BEARING SEAT |
| 3 | 402 | EXTERNAL FAN |
| 4 | 704 | RATCHET PIN CARRIER |
| 5 | 816 | RATCHET PIN |
Fault finding and recognition — PDF page 42
| Source row | Kinds of breakdown | Symptoms | Possible causes | Remedies |
|---|---|---|---|---|
| 1 | Fail to start without load | Motionless and soundless | Power-off | Consult power company |
| 2 | Fail to start without load | Motionless and soundless | Switch-off | Switch-on |
| 3 | Fail to start without load | Motionless and soundless | No fuse | Install fuse |
| 4 | Fail to start without load | Motionless and soundless | Broken wiring | Check wiring and repair |
| 5 | Fail to start without load | Motionless and soundless | Broken lead | Check wiring and repair |
| 6 | Fail to start without load | Motionless and soundless | Broken windings | Check windings and repair |
| 7 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Short circuit of circuit switches | Check circuit switches and replace |
| 8 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Incorrect wiring | Check wiring according to nameplate |
| 9 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Poor contact at terminals | Lock tightly |
| 10 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Windings grounded | Factory repair |
| 11 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Broken windings | Factory repair |
| 12 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Poor contact of circuit switches | Check and repair |
| 13 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Broken wiring | Check and repair |
| 14 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Poor contact of starting switches | Check and repair |
| 15 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Short circuit of starting switches | Check and repair |
| 16 | Fail to start without load | Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) | Incorrect connections of starting switches | Connect according to nameplate |
| 17 | Loading after start | Fuse blowing. Fail to restart due to trip-off of automatic switch | Insufficient capacity of fuse | Replace fuse if wiring permits |
| 18 | Loading after start | Fuse blowing. Fail to restart due to trip-off of automatic switch | Overload | Lighten load |
| 19 | Loading after start | Fuse blowing. Fail to restart due to trip-off of automatic switch | High load at low voltage | Check circuit capacity and reduce load |
| 20 | Loading after start | Overheating motor | Overload or intermittent overload | Lighten load |
| 21 | Loading after start | Overheating motor | Under-voltage | Check circuit capacity and power source |
| 22 | Loading after start | Overheating motor | Over-voltage | Check power source |
| 23 | Loading after start | Overheating motor | Ventilation duct clogged | Remove the foreign matter in the duct |
| 24 | Loading after start | Overheating motor | Ambient temperature exceeds 40°C | Correct insulation class to B or F, or lower ambient temperature. |
| 25 | Loading after start | Overheating motor | Friction between rotor and stator | Factory repair |
| 26 | Loading after start | Overheating motor | Fuse blown (Single-phase rotating) | Install the specified fuse |
| 27 | Loading after start | Overheating motor | Poor contact of circuit switches | Check and repair |
| 28 | Loading after start | Overheating motor | Poor contact of circuit starting switches | Check and repair |
| 29 | Loading after start | Overheating motor | Unbalanced three-phase voltage | Check circuit or consult power company |
Fault finding and recognition — PDF page 43
| Source row | Kinds of breakdown | Symptoms | Possible causes | Remedies |
|---|---|---|---|---|
| 1 | Loading after start | Speed falls sharply | Voltage drop | Check circuit and power source |
| 2 | Loading after start | Speed falls sharply | Sudden overload | Check machine |
| 3 | Loading after start | Speed falls sharply | Single-phase rotating | Check circuit and repair |
| 4 | Loading after start | Switch overheat | Insufficient capacity of switch | Replace switch |
| 5 | Loading after start | Switch overheat | High load | Lighten load |
| 6 | Loading after start | Bearing overheating | High belt tension | Adjust belt tension |
| 7 | Loading after start | Bearing overheating | Slack belt tension | Adjust belt tension |
| 8 | Loading after start | Bearing overheating | Misalignment between motor and machine shafts | Re-align |
| 9 | Loading after start | Bearing overheating | Over speed of bearing outer-ring | Adjust bracket |
| 10 | Loading after start | Bearing overheating | High bearing noise | Replace the damaged bearing |
| 11 | Noise | Electromagnetic noise induced by electricity | Occurrence from its first operation | May be normal |
| 12 | Noise | Electromagnetic noise induced by electricity | Sudden sharp noise and smoking | Short circuit of windings Should be repaired at factory |
| 13 | Noise | Bearing noise | Noise of low shishi or Thru-Thru | May be normal |
| 14 | Noise | Bearing noise | Kala-Kala as result of poor lubrication | Grease |
| 15 | Noise | Bearing noise | Kulo-Kulo as a result of deteriorated grease | Clean bearing and grease |
| 16 | Noise | Bearing noise | Sa-Sa or larger noise | Replace the damaged bearing |
| 17 | Noise | Mechanical noise caused by machinery | Loose belt sheave | Adjust key and lock the screw |
| 18 | Noise | Mechanical noise caused by machinery | Loose coupling or skip | Adjust the position of couplings, lock key and screw |
| 19 | Noise | Mechanical noise caused by machinery | Loose screw on fan cover | Lock fan cover screw tightly |
| 20 | Noise | Mechanical noise caused by machinery | Fan rubbing | Adjust fan position |
| 21 | Noise | Mechanical noise caused by machinery | Rubbing as a result of ingression of foreign matters | Clean motor interior and ventilation ducts |
| 22 | Noise | Mechanical noise caused by machinery | Wind noise | Noise induced by air flowing through ventilation ducts |
| 23 | Noise | Mechanical noise caused by machinery | Induced by conveyance machine | Repair machine |
| 24 | Vibration | Electromagnetic vibration | Short circuit of windings | Factory repair |
| 25 | Vibration | Electromagnetic vibration | Open circuit of rotor | Factory repair |
| 26 | Vibration | Mechanical vibration | Unbalanced rotor | Factory repair |
| 27 | Vibration | Mechanical vibration | Unbalanced fan | Factory repair |
| 28 | Vibration | Mechanical vibration | Broken fan blade | Replace fan |
| 29 | Vibration | Mechanical vibration | Unsymmetrical centers between belt sheaves | Align central points |
| 30 | Vibration | Mechanical vibration | Central points of couplings do not lie on the same level | Adjust the central points of couplings to the same level |
| 31 | Vibration | Mechanical vibration | Improper mounting installation | Lock the mounting screws |
| 32 | Vibration | Mechanical vibration | Motor mounting bed is not strong enough | Reinforce mounting bed |
| 33 | Vibration | Mechanical vibration | Mounting bed vibration caused by near machines | Eliminate the vibration source near motor |
Average material content — PDF page 44
| Source row | Material | Die-casting frame induction machinery | Steel plate frame induction machinery |
|---|---|---|---|
| 1 | Steel | 45 – 56 % | 79 - 83 % |
| 2 | Copper | 8 – 10 % | 12 – 14 % |
| 3 | Cast iron | 32 – 43 % | 1 – 3 % |
| 4 | Aluminum | 0 – 5 % | 0 - 1 % |
| 5 | Insulation materials | 1 - 2 % | 2 – 4 % |
| 6 | Stainless steel | Below 1 % | Below 1 % |
| 7 | Other | Below 1 % | Below 1 % |
Selection checks and source differences
The range page supplies no model-level hazardous-area certificate. Protection type names and brochure application examples must not be treated as blanket approval for a location or serial-numbered motor.
Brochure portfolio limits, cast-iron family descriptions, wound-rotor features and MV510 drive claims remain separate from this product’s published range.
REV07 has an unspecified exactly-1,000 V test boundary, ambiguous cooling-water solids wording, and grease maximum/overflow wording requiring the complete construction-specific procedure. These source ambiguities are preserved rather than resolved by calculation.
Product documents
- TECO-Large-Motors-and-Drives-Brochure-v1.pdf — Product page
- Teco-Manual-REV07.pdf — Product page
- TAC-EMD-Standard-Conditions-of-Sale-Final-May-2022.pdf — Shared website
- ISO9001-Intertek-SAI-Global-Certificate-QEC3088-Expiry-25-May-2029.pdf — Shared website
- ISO45001-Intertek-SAI-Global-Certificate-0185118-Expiry-22-August-2027.pdf — Shared website
Our company certificates and conditions of sale remain separate from the selected product’s ratings and approvals.
Talk to our team about your application, supply, motor rating and configuration.