TECO Electric Motors for Hazardous Areas

We build motors around demanding industrial duties, with hazardous-area options for oil and gas, chemical processing and other applications where the motor must match the site classification. Our published large-motor range covers 185–10,000 kW, 2–12 poles and frames 315–1000. We work with you to establish the electrical, mechanical and protection requirements of the complete installation.

Range and operating conditions

These are range-level specifications. They do not establish that every output, voltage, frame, cooling method and protection type is available in every combination.

Feature Published range specification
Output 185–10,000 kW
Poles 2–12
Cooling Totally enclosed air-to-air cooled (TEAAC) or totally enclosed fan cooled (TEFC)
Enclosure protection IP54–IP66, according to configuration
Frames 315–1000
Ambient 40°C
Elevation 1,000 m above sea level
Service factor 1.0 at 40°C
Mounting IM1001
Supply voltage Up to 11,000 V
Insulation Class F, 155°C classification; temperature rise ΔT = 80 K
Duty S1 continuous
Design N
Thermal protection To customer specification
Bearings Anti-friction or sleeve; oil forced or self-cooled arrangements as selected
Frame material Fabricated steel
Colour To customer specification

We describe the TECO Westinghouse Thermalastic™ form-wound insulation system for our high-voltage designs. The insulation class, allowable rise and ambient rating are different quantities: the 155°C classification is not an allowable site ambient temperature.

Select the protection for your installation

Our range page lists Ex n, Ex e, Ex d, Ex de and Ex p options. These identify different protection arrangements; they are not interchangeable approvals. We need the site classification, gas or dust characteristics, required equipment protection level, temperature requirements and installation conditions to establish the appropriate motor.

The documents attached to this page do not include a product-specific hazardous-area certificate or a model-by-model certified schedule. We therefore do not assign a gas group, temperature class, zone, converter operating range or special condition to an individual motor from the range description alone. Confirm the selected motor’s full marking, certificate, certified drawings and conditions with us before selection or installation.

For flameproof and increased-safety arrangements, the enclosure, terminal box and cable entries must be treated as the selected complete configuration. Corrosion resistance, unusually high or low ambient temperatures and drive operation require an agreed design. Our general descriptions of durability and efficient operation do not add an unlisted environmental rating or efficiency percentage.

Engineer the motor around the duty

Share the driven load, speed and starting requirements, supply, mounting, shaft dimensions, bearing loads, cooling arrangements and site conditions. We can then confirm the thermal protection, bearing and lubrication arrangement, enclosure and finish for your project. Replacement compatibility depends on the agreed outline and connection details.

Our September 2025 Large Motors and Drives brochure explains our broader capabilities: IEC and NEMA designs, vertical and horizontal arrangements, foot and flange options, purpose-built replacements, oversized sleeve or anti-friction bearings and project-specific ventilation and terminal boxes. Its AFJN/AFJP TEFC cast-iron and HV SCIM TEAAC sections are separate portfolio examples. Their construction descriptions do not replace this page’s fabricated-steel range specification.

The brochure’s 150–22,000 kW cover range, wider voltage claims and wound-rotor/MV510 sections describe the wider portfolio. They do not expand this hazardous-area product to those ratings or establish compatibility with every drive. Capacity graphics have no extracted numerical endpoints; we do not create model ratings by measuring their bars. The brochure’s power-density and weight comparisons have no stated comparison baseline, so we do not apply those percentages to this range.

Receipt, installation and maintenance

The linked 3A057D872E REV.07 three-phase induction-motor manual covers several motor constructions. Use it together with the selected motor’s instructions, hazardous-area certificate and certified drawings. Its general maintenance tables below remain conditional references; they cannot override a protection-specific restriction.

Check the delivery against the order and nameplate, inspect for damage, and keep storage and insulation-test records. Store the motor dry, ventilated and protected from vibration and corrosion. Follow the bearing-specific storage instructions and use heaters as specified. Motor lifting points support the motor, not the connected driven assembly; restore the specified transport restraints before moving it again.

Before starting, qualified personnel must check the foundation, alignment, wiring, earthing, protection, rotation, lubrication and any independent cooling. Keep cooling paths clear and monitor temperature, noise and vibration. Heaters must be off while the motor runs. The manual’s two-cold-start/one-hot-start guidance and additional-start cooling periods of 60 minutes loaded or 30 minutes unloaded remain subject to the actual motor duty. Its ±10% voltage, ±5% frequency and combined ±10% statements are general source guidance, not hazardous-area operating permission or a VSD envelope.

The manual’s insulation-test guidance quotes a historical standard and leaves exactly 1,000 V unspecified between its below/above categories. Use the confirmed test procedure; no missing boundary is inferred. The controlled drying procedure must be read in full. Brush and slip-ring instructions concern wound-rotor constructions, not every motor on this page.

Use the lubrication nameplate first. REV07 names SHELL Alvania RL3 unless otherwise specified and prohibits mixing grease types. Its maximum replenishment quantities and wording about replacing old grease must be resolved for the installed bearing. Ratchet-pin replacement guidance—three years, halved for the stated reverse-shock or frequent-start conditions—applies only to that optional vertical mechanism. Historical solvent and disposal descriptions are not presented as current working instructions.

Documents and selection support

We retain the complete 12-page brochure and 51-page manual, with the applicable reference tables below. No dedicated model datasheet, dimensional drawing or certificate was attached to this product in the collected source set. Ask us for the approved configuration documents for your installation; the range endpoints are not a substitute for them.

Manual — Installation references — REV07

Use the selected motor’s outline, nameplate and complete instructions. General site, foundation, alignment and belt references do not authorise a particular belt load or replace a hazardous-area approval.

Usual site limits — PDF page 8

Source row Property Source condition
1 Ambient temperature −20 to +40°C
2 Relative humidity totally enclosed Below95%
3 Relative humidity semi-enclosed Below80%
4 Elevation Below1000m
5 Water-cooled motor or bearing cooling coil Ambient should not be below0°C to prevent frost damage

Horizontal four-bolt foundation reactions — PDF page 8

Source row Load case Reaction kg per bolt at centreline
1 Static weight Motor weight / bolt number
2 Rated torque Motor weight / bolt number ± TR/(2L)
3 Maximum torque Motor weight / bolt number ± Tmax/(2L)

Alignment tolerances — PDF page 13

Source row TIR Rotating speed Solid coupling (mm) Flexible coupling (mm)
1 C 2500rpm and above 0.03 0.03
2 C Below 2500rpm 0.04 0.05
3 A 2500rpm and above 0.03 0.03
4 A Below 2500rpm 0.03 0.04

Belt-sheave application for general electric motors — PDF page 16

Source row Output4P(kW) Output6P(kW) Output8P(kW) Conventional V-belt type Conventional belt count Conventional minimum PCD(mm) Conventional maximum width(mm) Narrow V-belt type Narrow belt count Narrow minimum PCD(mm) Narrow maximum width(mm)
1 11 -- -- B 4 160 82 3V 4 125 48
2 -- 11 -- B 5 170 101 3V 5 140 59
3 -- -- 11 B 5 190 101 3V 6 160 69
4 15 -- -- B 5 170 101 3V 6 125 69
5 -- 15 -- B 5 224 101 3V 6 160 69
6 -- -- 15 C 4 224 111 5V 3 180 60
7 18.5 -- -- B 5 200 101 3V 6 140 69
8 -- 18.5 -- C 4 224 111 5V 3 180 60
9 -- -- 18.5 C 5 224 136 5V 4 180 78
10 22 -- -- B 5 224 101 3V 6 160 69
11 -- 22 -- C 5 224 136 5V 4 180 78
12 -- -- 22 C 5 250 136 5V 4 200 78
13 30 -- -- C 5 224 136 5V 4 180 78
14 -- 30 -- C 5 265 136 5V 4 224 78
15 -- -- 30 C 6 265 162 5V 5 224 95
16 37 -- -- C 6 224 162 5V 4 200 78
17 -- 37 -- C 6 265 162 5V 4 224 78
18 -- -- 37 C 7 280 187 5V 5 250 95
19 45 -- -- C 6 265 162 5V 4 224 78
20 -- 45 -- C 7 280 187 5V 5 224 95
21 -- -- 45 C 7 315 187 5V 6 250 113
22 55 -- -- C 7 265 187 5V 5 224 95
23 -- 55 -- C 8 300 213 5V 6 250 113
24 -- -- 55 D 5 355 196 5V 6 280 113
25 75 -- -- C 8 315 213 5V 6 250 113
26 -- 75 -- D 6 355 233 5V 6 315 113
27 -- -- 75 D 6 400 233 5V 6 355 113
28 -- 90 -- D 6 400 233 5V 6 355 113
29 -- -- 90 D 6 425 233 8V 4 355 124
30 -- 110 -- D 7 400 270 8V 4 355 124
31 -- 132 110 D 7 450 270 8V 4 400 124
32 -- 160 132 D 9 450 344 8V 4 450 124

Manual — Starting and monitoring — REV07

Qualified personnel must isolate, test and discharge equipment using the complete procedure. Drying limits, oil/water systems and bearing/winding monitoring apply only to the stated construction. A general supply tolerance is not an extension of certified hazardous-area limits.

Megger source instruction — PDF page 19

Source row Rated-voltage wording DC megger voltage
1 Below1000V 500VDC
2 Above1000V 1000VDC

IEEE43-2000 minimum insulation resistance as quoted — PDF page 19

Source row Winding scope Minimum MΩ at40°C
1 Most windings made before1970,all field windings,and others not described below kV+1
2 Most DC armatures and AC windings built after about1970 with form-wound coils 100
3 Machines with random-wound stator coils and form-wound coils rated below1kV 5

Drying and electrical supply conditions — PDF page 20

Source row Property Source statement
1 Heating cycle 15–20hours
2 Insulation evaluation temperature Correct to40°C
3 Approximation for new winding above dew point Resistance approximately halves per10°C increase
4 Supply capacity Must be sufficient
5 Supply voltage and frequency Identical to nameplate ratings
6 Voltage variation Within±10%rated value and phase-to-phase voltages balanced

Flood lubrication oil inlet temperature — PDF page 21

Source row Condition Source temperature
1 Normal Below50°C (122°F)
2 Alarm 60°C (140°F)
3 Trip 65°C (149°F)

Cooling-water inlet temperature alarm/trip — PDF page 23

Source row Inlet water condition Temperature
1 Alarm 35℃ (95℉)
2 Trip 40℃ (104℉)

Bearing temperature recommendations — PDF page 25

Source row Bearing type Detector Alarm temperature Trip temperature
1 Sleeve Bearings. By permanently installed detector 90℃(194℉) 95℃(203℉)
2 Anti-Friction Bearings. By permanently installed detector 95℃(203℉) 100℃(212℉)

Winding operating temperature recommendations — PDF page 26

Source row Service factor Alarm Trip
1 Service Factor 1.0 130℃ (266℉) 150℃ (302℉)
2 Service Factor 1.15 (when specified) 155℃ (311℉) 165℃ (329℉)

Manual — Lubrication — REV07

The lubrication nameplate and actual bearing, speed and duty take priority. Do not interpolate the discrete speed columns. The source halves grease intervals for belt drive or adverse conditions; use the shorter applicable bearing interval. Grease quantities are maximums for one replenishment per bearing. Do not mix grease types. Vertical and horizontal oil references are separate.

Table1 — 62XX/63XX/72XX/73XX — PDF page 30

Source row Bearing row label 600 and720RPM / hours 750 and900RPM / hours 1000 and1200RPM / hours 1500 and1800RPM / hours 3000 and3600RPM / hours
1 6210 3000 3000 3000 3000 2000
2 12 3000 3000 3000 3000 2000
3 13 3000 3000 3000 3000 1000
4 14 3000 3000 3000 3000 1000
5 15 3000 3000 3000 2000 720
6 16 3000 3000 3000 2000 720
7 17 3000 3000 3000 2000 [outside chart boundary]
8 18 3000 3000 3000 2000 [outside chart boundary]
9 20 3000 3000 3000 2000 [outside chart boundary]
10 22 3000 3000 3000 1500 [outside chart boundary]
11 24 3000 3000 3000 1500 [outside chart boundary]
12 26 3000 3000 2000 1000 [outside chart boundary]
13 28 3000 3000 2000 1000 [outside chart boundary]
14 30 3000 3000 2000 500 [outside chart boundary]
15 32 3000 3000 1500 500 [outside chart boundary]
16 34 3000 3000 1500 [outside chart boundary] [outside chart boundary]
17 36 3000 2000 1000 [outside chart boundary] [outside chart boundary]
18 38 3000 2000 1000 [outside chart boundary] [outside chart boundary]

Table1 — NU2XX/NU3XX — PDF page 30

Source row Bearing row label 600 and720RPM / hours 750 and900RPM / hours 1000 and1200RPM / hours 1500 and1800RPM / hours
1 NU214 3000 3000 3000 2000
2 15 3000 3000 3000 2000
3 16 3000 3000 3000 2000
4 17 3000 3000 3000 1500
5 18 3000 3000 3000 1500
6 20 3000 3000 3000 1000
7 22 3000 3000 2000 1000
8 24 3000 3000 2000 1000
9 26 3000 3000 2000 500
10 28 3000 3000 2000 500
11 30 3000 2000 1000 500
12 32 3000 2000 1000 [outside chart boundary]
13 34 3000 2000 1000 [outside chart boundary]
14 36 2000 2000 1000 [outside chart boundary]
15 38 2000 1000 1000 [outside chart boundary]
16 40 2000 1000 [outside chart boundary] [outside chart boundary]
17 44 1000 1000 [outside chart boundary] [outside chart boundary]
18 48 1000 1000 [outside chart boundary] [outside chart boundary]

Table1 — 222XX/223XX — PDF page 30

Source row Bearing row label 600 and720RPM / hours 750 and900RPM / hours 1000 and1200RPM / hours 1500 and1800RPM / hours
1 22220 1000 1000 500 300
2 22 1000 1000 500 [outside chart boundary]
3 24 1000 1000 500 [outside chart boundary]
4 26 1000 1000 500 [outside chart boundary]
5 28 1000 500 300 [outside chart boundary]
6 30 1000 500 300 [outside chart boundary]
7 32 1000 500 300 [outside chart boundary]
8 34 500 500 [outside chart boundary] [outside chart boundary]
9 36 500 500 [outside chart boundary] [outside chart boundary]
10 38 500 300 [outside chart boundary] [outside chart boundary]
11 40 500 300 [outside chart boundary] [outside chart boundary]
12 44 300 [outside chart boundary] [outside chart boundary] [outside chart boundary]
13 48 300 [outside chart boundary] [outside chart boundary] [outside chart boundary]

Table2 — 62XX/72XX/NU2XX/222XX — PDF page 31

Source row Printed bearing number Maximum replenishment g
1 6210 30
2 6212 40
3 6213 50
4 6214 50
5 6215 60
6 6216 60
7 6217 80
8 6218 80
9 6220 100
10 6222 120
11 6224 120
12 6226 140
13 6228 160
14 6230 180
15 6232 200
16 6234 250
17 6236 300
18 6238 350
19 6240 400
20 6244 450
21 6248 500

Table2 — 63XX/73XX/NU3XX/223XX — PDF page 31

Source row Printed bearing number Maximum replenishment g
1 6310 40
2 6312 60
3 6313 80
4 6314 80
5 6315 100
6 6316 100
7 6317 120
8 6318 120
9 6320 160
10 6322 220
11 6324 270
12 6326 300
13 6328 400
14 6330 450
15 6332 500
16 6334 600
17 6336 700
18 6338 800
19 6340 900
20 6344 900
21 6348 900

Table3 — vertical motor oil viscosity — PDF page 33

Source row Bearing type Oil viscosity Pole scope
1 Angular contact ball72XX,73XX ISO VG32 (150SSU/100°F) 2pole
2 Angular contact ball72XX,73XX ISO VG68 (300SSU/100°F) 4pole andabove
3 Spherical roller293XX,294XX ISO VG68 (300SSU/100°F) 4pole
4 Spherical roller293XX,294XX ISO VG150 (700SSU/100°F) 6pole andabove
5 RENK Vertical Bearing Inserts TypeEV orKingsbury Type ISO VG68 (300SSU/100°F) 4pole andabove

Table4 — horizontal motor oil viscosity — PDF page 33

Source row Bearing type Oil viscosity Pole scope
1 Sleeve bearing ISO VG32 (150SSU/100°F) 2pole
2 Sleeve bearing ISO VG46 (200SSU/100°F) 4pole
3 Sleeve bearing ISO VG68 (300SSU/100°F) 6pole andabove

Source oil equivalent names — PDF page 35

Source row ISO ESSO equivalent MOBIL equivalent cSt at40°C SUS/100°F
1 VG32 ESSO TERESSO32 MOBIL DTE OIL LIGHT 32 150
2 VG46 ESSO TERESSO46 MOBIL DTE OIL MEDIUM 46 200
3 VG68 ESSO TERESSO68 MOBIL OIL HEAVY MEDIUM 68 300
4 VG150 ESSO NUTO150 MOBIL DTE OIL EXTRA HEAVY 150 700

Manual — Optional ratchet, troubleshooting and materials — REV07

The non-reverse ratchet applies only to an equipped vertical high-thrust motor. Troubleshooting is for qualified diagnosis with the full safety procedure; material percentages are source averages, not a selected motor’s bill of materials.

Non-reverse ratchet component labels — PDF page 40

Source row Item Name
1 104 RATCHET
2 214 BEARING SEAT
3 402 EXTERNAL FAN
4 704 RATCHET PIN CARRIER
5 816 RATCHET PIN

Fault finding and recognition — PDF page 42

Source row Kinds of breakdown Symptoms Possible causes Remedies
1 Fail to start without load Motionless and soundless Power-off Consult power company
2 Fail to start without load Motionless and soundless Switch-off Switch-on
3 Fail to start without load Motionless and soundless No fuse Install fuse
4 Fail to start without load Motionless and soundless Broken wiring Check wiring and repair
5 Fail to start without load Motionless and soundless Broken lead Check wiring and repair
6 Fail to start without load Motionless and soundless Broken windings Check windings and repair
7 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Short circuit of circuit switches Check circuit switches and replace
8 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Incorrect wiring Check wiring according to nameplate
9 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Poor contact at terminals Lock tightly
10 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Windings grounded Factory repair
11 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Broken windings Factory repair
12 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Poor contact of circuit switches Check and repair
13 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Broken wiring Check and repair
14 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Poor contact of starting switches Check and repair
15 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Short circuit of starting switches Check and repair
16 Fail to start without load Fuse blowing. (Automatic switch trips off, slow start with electromagnetic noise) Incorrect connections of starting switches Connect according to nameplate
17 Loading after start Fuse blowing. Fail to restart due to trip-off of automatic switch Insufficient capacity of fuse Replace fuse if wiring permits
18 Loading after start Fuse blowing. Fail to restart due to trip-off of automatic switch Overload Lighten load
19 Loading after start Fuse blowing. Fail to restart due to trip-off of automatic switch High load at low voltage Check circuit capacity and reduce load
20 Loading after start Overheating motor Overload or intermittent overload Lighten load
21 Loading after start Overheating motor Under-voltage Check circuit capacity and power source
22 Loading after start Overheating motor Over-voltage Check power source
23 Loading after start Overheating motor Ventilation duct clogged Remove the foreign matter in the duct
24 Loading after start Overheating motor Ambient temperature exceeds 40°C Correct insulation class to B or F, or lower ambient temperature.
25 Loading after start Overheating motor Friction between rotor and stator Factory repair
26 Loading after start Overheating motor Fuse blown (Single-phase rotating) Install the specified fuse
27 Loading after start Overheating motor Poor contact of circuit switches Check and repair
28 Loading after start Overheating motor Poor contact of circuit starting switches Check and repair
29 Loading after start Overheating motor Unbalanced three-phase voltage Check circuit or consult power company

Fault finding and recognition — PDF page 43

Source row Kinds of breakdown Symptoms Possible causes Remedies
1 Loading after start Speed falls sharply Voltage drop Check circuit and power source
2 Loading after start Speed falls sharply Sudden overload Check machine
3 Loading after start Speed falls sharply Single-phase rotating Check circuit and repair
4 Loading after start Switch overheat Insufficient capacity of switch Replace switch
5 Loading after start Switch overheat High load Lighten load
6 Loading after start Bearing overheating High belt tension Adjust belt tension
7 Loading after start Bearing overheating Slack belt tension Adjust belt tension
8 Loading after start Bearing overheating Misalignment between motor and machine shafts Re-align
9 Loading after start Bearing overheating Over speed of bearing outer-ring Adjust bracket
10 Loading after start Bearing overheating High bearing noise Replace the damaged bearing
11 Noise Electromagnetic noise induced by electricity Occurrence from its first operation May be normal
12 Noise Electromagnetic noise induced by electricity Sudden sharp noise and smoking Short circuit of windings Should be repaired at factory
13 Noise Bearing noise Noise of low shishi or Thru-Thru May be normal
14 Noise Bearing noise Kala-Kala as result of poor lubrication Grease
15 Noise Bearing noise Kulo-Kulo as a result of deteriorated grease Clean bearing and grease
16 Noise Bearing noise Sa-Sa or larger noise Replace the damaged bearing
17 Noise Mechanical noise caused by machinery Loose belt sheave Adjust key and lock the screw
18 Noise Mechanical noise caused by machinery Loose coupling or skip Adjust the position of couplings, lock key and screw
19 Noise Mechanical noise caused by machinery Loose screw on fan cover Lock fan cover screw tightly
20 Noise Mechanical noise caused by machinery Fan rubbing Adjust fan position
21 Noise Mechanical noise caused by machinery Rubbing as a result of ingression of foreign matters Clean motor interior and ventilation ducts
22 Noise Mechanical noise caused by machinery Wind noise Noise induced by air flowing through ventilation ducts
23 Noise Mechanical noise caused by machinery Induced by conveyance machine Repair machine
24 Vibration Electromagnetic vibration Short circuit of windings Factory repair
25 Vibration Electromagnetic vibration Open circuit of rotor Factory repair
26 Vibration Mechanical vibration Unbalanced rotor Factory repair
27 Vibration Mechanical vibration Unbalanced fan Factory repair
28 Vibration Mechanical vibration Broken fan blade Replace fan
29 Vibration Mechanical vibration Unsymmetrical centers between belt sheaves Align central points
30 Vibration Mechanical vibration Central points of couplings do not lie on the same level Adjust the central points of couplings to the same level
31 Vibration Mechanical vibration Improper mounting installation Lock the mounting screws
32 Vibration Mechanical vibration Motor mounting bed is not strong enough Reinforce mounting bed
33 Vibration Mechanical vibration Mounting bed vibration caused by near machines Eliminate the vibration source near motor

Average material content — PDF page 44

Source row Material Die-casting frame induction machinery Steel plate frame induction machinery
1 Steel 45 – 56 % 79 - 83 %
2 Copper 8 – 10 % 12 – 14 %
3 Cast iron 32 – 43 % 1 – 3 %
4 Aluminum 0 – 5 % 0 - 1 %
5 Insulation materials 1 - 2 % 2 – 4 %
6 Stainless steel Below 1 % Below 1 %
7 Other Below 1 % Below 1 %

Selection checks and source differences

The range page supplies no model-level hazardous-area certificate. Protection type names and brochure application examples must not be treated as blanket approval for a location or serial-numbered motor.

Brochure portfolio limits, cast-iron family descriptions, wound-rotor features and MV510 drive claims remain separate from this product’s published range.

REV07 has an unspecified exactly-1,000 V test boundary, ambiguous cooling-water solids wording, and grease maximum/overflow wording requiring the complete construction-specific procedure. These source ambiguities are preserved rather than resolved by calculation.

Product documents

Our company certificates and conditions of sale remain separate from the selected product’s ratings and approvals.

Talk to our team about your application, supply, motor rating and configuration.